845 resultados para Interval Variable
Resumo:
This experiment was developed in order to evaluation the efficiency of pheromone to control the pink bollworm and the total time of its release in cotton field. The experiment was installed in field conditions, in Chapadao do Sul/SP/Brazil, from January to April, 1998. The treatments consisted of 2 areas, being one of 30ha, where it was applied the pheromone and another of 10ha that was chosen as control area and did not receive pheromone. In the treated area, the laboratory synthesized sex pheromone (PB-Rope) was used thought of dispensers that allowed the slow and gradual release of the active substance. A total of 250 dispenser per hectare were evenly hand distributed in the area. The dispensers were wrapped around the plants. Both areas (treated area and untreated area) were monitored by delta trap. For evaluation of the boll damage, the treatment area was divided into 4 sub-areas. Twenty five green bolls were collected at random from each sub-area at 48 and 65 days after pheromone treatment. Bolls were cracked open by hand, and number of the bolls with symptoms of pink bollworm attacks was recorded. For evaluation of the productivity four areas were demarcated in each treatment, where all fibers and seeds harvested were weighted. Release rate of pheromone from dispenser was evaluated through of the weigh of the dispensers. Were marked and weighed in analytic scale, 20 dispensers contend the pheromone, being placed 10 dispensers under the cotton plants in treated area and other 10 dispensers in an open area. To every 15 days the dispensers were retired and weighed in analytic scale and soon after put back in the field in the same places. The results showed that only one application of mating disrupt pheromone, used in a dosage of 250 dispenser/ha, reached 80% of control for pink bollworm. the release period of pheromone from dispenser, after the application, was 120 days.
Resumo:
This paper deals with the joint economic design of x̄ and R charts when the occurrence times of assignable causes follow Weibull distributions with increasing failure rates. The variable quality characteristic is assumed to be normally distributed and the process is subject to two independent assignable causes (such as tool wear-out, overheating, or vibration). One cause changes the process mean and the other changes the process variance. However, the occurrence of one kind of assignable cause does not preclude the occurrence of the other. A cost model is developed and a non-uniform sampling interval scheme is adopted. A two-step search procedure is employed to determine the optimum design parameters. Finally, a sensitivity analysis of the model is conducted, and the cost savings associated with the use of non-uniform sampling intervals instead of constant sampling intervals are evaluated.
Resumo:
In this study, we compared the levels of neutralizing antibodies induced by inactivated rabies vaccine in cattle by using three alternative immunization procedures. Forty-five bovines (breed nelore) were then organized in three groups (A, B and C, with 15 animals/group). Group A received only one vaccine dose at day zero and Group B received the first dose at day zero and then another dose at day 30 (early booster). Group C was also immunized with two doses; however, the booster was postponed until day 180 after the first dose (delayed booster). Blood samples were withdrawn at days zero (before the first dose) and 30, 210, 390, and 540 after the beginning of immunization and the antibody titers were evaluated by mouse neutralization test. The protocol used to immunize Group C (booster at day 180) was clearly more efficient. In this group, antibody levels were higher and also remained higher for longer periods in comparison with the other two groups. These results show that booster timing significantly affected antibody levels. Therefore, programs addressed to control this disease in cattle should consider not only the use of a booster but also its administration time.
Resumo:
This paper presents necessary and sufficient conditions for the following problem: given a linear time invariant plant G(s) = N(s)D(s)-1 = C(sI - A]-1B, with m inputs, p outputs, p > m, rank(C) = p, rank(B) = rank(CB) = m, £nd a tandem dynamic controller Gc(s) = D c(s)-1Nc(s) = Cc(sI - A c)-1Bc + Dc, with p inputs and m outputs and a constant output feedback matrix Ko ε ℝm×p such that the feedback system is Strictly Positive Real (SPR). It is shown that this problem has solution if and only if all transmission zeros of the plant have negative real parts. When there exists solution, the proposed method firstly obtains Gc(s) in order to all transmission zeros of Gc(s)G(s) present negative real parts and then Ko is found as the solution of some Linear Matrix Inequalities (LMIs). Then, taking into account this result, a new LMI based design for output Variable Structure Control (VSC) of uncertain dynamic plants is presented. The method can consider the following design specifications: matched disturbances or nonlinearities of the plant, output constraints, decay rate and matched and nonmatched plant uncertainties. © 2006 IEEE.
Resumo:
This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.
Resumo:
This paper presents two Variable Structure Controllers (VSC) for continuous-time switched plants. It is assumed that the state vector is available for feedback. The proposed control system provides a switching rule and also the variable structure control input. The design is based on Lyapunov-Metzler (LM) inequalities and also on Strictly Positive Real (SPR) systems stability results. The definition of Lyapunov-Metzler-SPR (LMS) systems and its direct application in the design of VSC for switched systems are introduced in this paper. Two examples illustrate the design of the proposed VSC, considering a plant given by a switched system with a switched-state control law and two linear time-invariant systems, that are not controllable and also can not be stabilized with state feedback. ©2008 IEEE.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In the present study, data of 1,578 first lactation females, calving from 1985 to 2006 were analysed with the purpose of estimating genetic parameters for milk yield (MY), age at first calving (AFC) and interval between first and second calving (IBFSC) in dairy buffaloes of the Murrah breed in Brazil, Heritability estimates for MY, AFC and IBFSC traits were 0.20, 0.07 and 0.14, respectively. Genetic correlations between MY and AFC and IBFSC were -0.12 and 0.07, respectively, while the corresponding phenotypic correlations were -0.15 and 0.30, respectively. Genetic and phenotypic correlations between AFC and IBFSC were 0.35 and 0.37, respectively. Genetic correlation between MY and AFC showed desirable negative association, suggesting that daughters of the bulls with high breeding values for MY could reach physiological mature at a precocious age. Genetic correlation between MY and IBFSC, showed that the selection for milk production could result in the increase of calving intervals.
Resumo:
We consider an infinite horizon optimal impulsive control problems for which a given cost function is minimized by choosing control strategies driving the state to a point in a given closed set C ∞. We present necessary conditions of optimality in the form of a maximum principle for which the boundary condition of the adjoint variable is such that non-degeneracy due to the fact that the time horizon is infinite is ensured. These conditions are given for conventional systems in a first instance and then for impulsive control problems. They are proved by considering a family of approximating auxiliary interval conventional (without impulses) optimal control problems defined on an increasing sequence of finite time intervals. As far as we know, results of this kind have not been derived previously. © 2010 IFAC.
Resumo:
This paper presents a control method for a class of continuous-time switched systems, using state feedback variable structure controllers. The method is applied to the control of a two-cell dc-dc buck converter and a control circuit design using the software PSpice is proposed. The design is based on Lyapunov-Metzler-SPR systems and the performance of the resulting control system is superior to that afforded by a recently-proposed alternative sliding-mode control technique. The dc-dc power converters are very used in industrial applications, for instance, in power systems of hybrid electric vehicles and aircrafts. Good results were obtained and the proposed design is also inexpensive because it uses electric components that can be easily found for the hardware implementation. Future researches on the subject include the hardware validation of the dc-dc converter controller and the robust control design of switched systems, with structural failures. © 2011 IEEE.
Resumo:
Plasma processing of the surfaces of biomaterials is interesting because it enables modification of the characteristics of a surface without affecting bulk properties. In addition, the results are strongly influenced by the conditions of the treatment. Therefore, by adjusting the plasma parameters it is possible to tailor the surface properties to best fulfill the requirements of a given application. In this work, polyurethane substrates have been subjected to sulfur hexafluoride glow discharge plasmas. The influences of different SF 6 plasma exposure times and pressures on the adhesion of Staphylococcus aureus and Pseudomonas aeruginosa to the polymer have been investigated. The wettability and surface free energy have been evaluated via contact angle measurements. At low pressure (6.7 Pa) the contact angle decreases with increasing exposure time in the 180 s to 540 s interval, but at higher pressure (13.3 Pa) it increases as a function of the same variable. Bacterial adhesion has been quantified from in vitro experiments by determining the growth of colonies on Petri dishes treated with agar nutrient. It has been observed that the surface properties play an important role in microbe adhesion. For instance, the density of adhered P. aeruginosa decreased as the surface contact angle increased. S. aureus preferred to adhere to hydrophobic surfaces. © 2011 by Begell House, Inc.
Resumo:
This paper presents a control method for a class of continuous-time switched systems, using state feedback variable structure controllers. The method is applied to the control of a non-trivial dc-dc power converter and a simple and inexpensive control circuit design, that was simulated using the software PSpice, is proposed. The design is based on Lyapunov-Metzler-SPR systems and the performance of the resulting control system is superior to that afforded by a recently proposed alternative sliding-mode control technique. © 2011 IFAC.
Resumo:
This paper proposes a bridgeless boost interleaved PFC (power factor correction) converter with variable duty cycle control. The application of bridgeless technique causes reduction of conduction losses, while the interleaving technique of converters cells allows division of efforts in semiconductor devices and reduction of weight and volume of the input EMI filter. The use of variable duty cycle control has the functions of regulating the output voltage and eliminating the low order harmonic components that appears in the input current of the common interleaved power factor converters working in Discontinuous Conduction Mode (DCM). The simulation results of the proposed converter presented high power factor and a good transient response in relation to the output voltage regulation in presence of high load variations and supply voltage variations. © 2011 IEEE.
Resumo:
Documento disponible en inglés (565.03)
Resumo:
Incluye Bibliografía