996 resultados para Interstitial carbon


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluctuation of field emission in carbon nanotubes (CNTs) is riot desirable in many applications and the design of biomedical x-ray devices is one of them. In these applications, it is of great importance to have precise control of electron beams over multiple spatio-temporal scales. In this paper, a new design is proposed in order to optimize the field emission performance of CNT arrays. A diode configuration is used for analysis, where arrays of CNTs act as cathode. The results indicate that the linear height distribution of CNTs, as proposed in this study, shows more stable performance than the conventionally used unifrom distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The polymer-amorphous carbon composites show a negative magnetoconductance which varies as B-2 at low fields which changes to B-1/2 at sufficiently high fields. The magnetoconductance gives the evidence of electron-electron interaction in composites whose conductivity follows thermal fluctuation induced tunneling and falls in the critical regime. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanoconfined synthesized crystalline fullerene mesoporous carbon (C60-FMC) with bimodal pore architectures of 4.95 nm and 10-15 nm pore sizes characterized by XRD, TEM, nitrogen adsorption/ desorption isotherm and solid-state NMR, and the material was used for protein immobilization. The solid-state 13C NMR spectrum of C60-FMC along with XRD, BET and TEM confirms the formation of fullerene mesoporous carbon structure C60-FMC. The immobilization of albumin (from bovine serum, BSA) protein biomolecule in a buffer solution at pH 4.7 was used to determine the adsorption properties of the C60-FMC material and its structural changes investigated by FT-IR. We demonstrated that the C60-FMC with high surface area and pore volumes have excellent adsorption capacity towards BSA protein molecule. Protein adsorption experiments clearly showed that the C60-FMC with bimodal pore architectures (4.95 nm and 10-15 nm) are suitable material to be used for protein adsorption

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Highly ordered mesoporous carbon (MC) has been synthesized from sucrose, a non-toxic and costeffective source of carbon. X-ray diffraction, N2 adsorption–desorption isotherm and transmission electron micrograph (TEM) were used to characterize the MC. The XRD patterns show the formation of highly ordered mesoporous structures of SBA15 and mesoporous carbon. The N2 adsorptiondesorption isotherms suggest that the MC exhibits a narrow pore-size distribution with high surface area of 1559 m2/g. The potential application of MC as a novel electrode material was investigated using cyclic voltammetry for riboflavin (vitamin B2) and dopamine. MC-modified glassy carbon electrode (MC/GC) shows increase in peak current compared to GC electrode in potassium ferricyanide which clearly suggest that MC/GC possesses larger electrode area (1.8 fold) compared with bare GC electrode. The electrocatalytic behavior of MC/GC was investigated towards the oxidation of riboflavin (vitamin B2) and dopamine using cyclic voltammetry which show larger oxidation current compared to unmodified electrode and thus MC/GC may have the potential to be used as a chemically modified electrode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon nanotubes (CNTs) have emerged as promising candidates for biomedical x-ray devices and other applications of field emission. CNTs grown/deposited in a thin film are used as cathodes for field emission. In spite of the good performance of such cathodes, the procedure to estimate the device current is not straightforward and the required insight towards design optimization is not well developed. In this paper, we report an analysis aided by a computational model and experiments by which the process of evolution and self-assembly (reorientation) of CNTs is characterized and the device current is estimated. The modeling approach involves two steps: (i) a phenomenological description of the degradation and fragmentation of CNTs and (ii) a mechanics based modeling of electromechanical interaction among CNTs during field emission. A computational scheme is developed by which the states of CNTs are updated in a time incremental manner. Finally, the device current is obtained by using the Fowler–Nordheim equation for field emission and by integrating the current density over computational cells. A detailed analysis of the results reveals the deflected shapes of the CNTs in an ensemble and the extent to which the initial state of geometry and orientation angles affect the device current. Experimental results confirm these effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Painful bladder syndrome/interstitial cystitis (PBS/IC) is a chronic urinary bladder disorder of unknown etiology characterized by symptoms of bladder pain and urinary frequency. PBS/IC is a chronic disease in which drug therapy has not led to significant success over the course of time. If the symptoms of PBS/IC are refractory to standard treatments, a possible cure might demand surgical intervention involving cystectomy. The eventual autoimmune etiology in mind, immunosuppressive drug therapy with cyclosporine A (CyA) was started to patients with refractory PBS/IC. CyA is a potent anti-inflammatory drug, a calcineurin inhibitor which inhibits T lymphocyte IL-2 produc-tion. T cells are present in abundance in inflammation of the bladder in PBS/IC. On the basis of a pilot, short-term study with CyA on PBS/IC, use of CyA was continued empirically over the long term. We conducted a prospective, randomized, six-month study in 64 patients comparing the effect of CyA with the FDA approved treatment, pentosan polysulfate sodium (PPS). We measured the drug effect on patient s symptoms, the potassium sensitivity test, and on urinary biomarkers. We further tested the impact of CyA, PPS, DMSO and BCG therapy on a health-related quality of life questionnaire and evaluated the response rate to treatment with these therapies. Long-term use of CyA was safe and effective in PBS/IC patients. The good clinical effect matured individually during the years in which CyA was continued. Cessation of medication led to the reappearance of symptoms, and restarting CyA to renewed alleviation, so that CyA was administered as continuous medication. The response rate to CyA increased during the study period, comprising 75% of CyA patients at six months. 19% of patients responded to PPS therapy. Adverse effects were more common in the CyA group, underlining the importance of monitoring the drug safety and appropriate titration of the dose. The potassium sensitivity test is positive in the majority of PBS/IC patients. Successful therapy of PBS/IC can alter nerve sensitivity to external potassium. This effect was seen more often after CyA therapy. Successful treatment of PBS/IC with CyA resulted to decreasing urinary levels of EGF. IL-6 levels in urine were higher among older patient with a longer history of PBS/IC. In these patients, reduced levels of urinary IL-6 were measured after CyA therapy. Patients who experience the best treatment response have improved quality of life according to the post-treatment health-related quality of life (HRQOL) questionnaire. CyA had more impact on the ma-jority of the aspects of QoL than PPS. Despite DMSO therapy being more successful than BCG in the count of responders, DMSO and BCG had equal effects on the HRQOL questionnaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grewia tiliaefolia is widely used in traditional Indian medicines to cure jaundice, biliousness, dysentery and the diseases of blood. Bioassay-guided fractionation of methanolic extract of the G. tiliaefolia bark has resulted in the isolation of D-erythro-2-hexenoic acid gamma-lactone (EHGL) and gulonic acid gamma-lactone (GAGL). Hepatoprotective activity of the methanolic extract and the isolated constituents were evaluated against CCl4-induced hepatotoxicity in rats. The treatment with methanolic extract, EHGL and GAGL at oral doses of 100, 150 and 60 mg/kg respectively with concomitant CCl4 intraperitoneal injection (I ml/kg) significantly reduced the elevated plasma levels of aminotransferases, alkaline phosphatase and the incidence of liver necrosis compared with the CCl4-injected group without affecting the concentrations of serum bilirubin and hepatic markers. EHGL and GAGL significantly inhibited the elevated levels of thiobarbituric acid reactive substances and glutathione in liver homogenates. Histology of the liver tissues of the extract and isolated constituents treated groups showed the presence of normal hepatic cords, absence of necrosis and fatty infiltration as similar to the normal control. The results revealed that the hepatoprotective activity of EHGL is significant as similar to the standard drug silymarin. To clarify the influence of the extract and isolated constituents on the protection of oxidative-hepatic damage, we examined in vitro antioxidant properties of the test compounds. The extract and the constituents showed significant free radical scavenging activity. These results suggest that the extract as well as the constituents could protect the hepatocytes from CCl4-induced liver damage perhaps, by their anti-oxidative effect on hepatocytes, hence eliminating the deleterious effects of toxic metabolites from CCl4, (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this experimental study, the dry sliding wear and two-body abrasive wear behaviour of graphite filled carbon fabric reinforced epoxy composites were investigated. Carbon fabric reinforced epoxy composite was used as a reference material. Sliding wear experiments were conducted using a pin-on-disc wear tester under dry contact condition. Mass loss was determined as a function of sliding velocity for loads of 25, 50, 75, and 100 N at a constant sliding distance of 6000 m. Two-body abrasive wear experiments were performed under multi-pass condition using silicon carbide (SiC) of 150 and 320 grit abrasive papers. The effects of abrading distance and different loads have been studied. Abrasive wear volume and specific wear rate as a function of applied normal load and abrading distance were also determined. The results show that in dry sliding wear situations, for increased load and sliding velocity, higher wear loss was recorded. The excellent wear characteristics were obtained with carbon-epoxy containing graphite as filler. Especially, 10 wt.% of graphite in carbon-epoxy gave a low wear rate. A graphite surface film formed on the counterface was confirmed to be effective in improving the wear characteristics of graphite filled carbon-epoxy composites. In case of two-body abrasive wear, the wear volume increases with increasing load/abrading distance. Experimental results showed the type of counterface (hardened steel disc and SiC paper) material greatly influences the wear behaviour of the composites. Wear mechanisms of the composites were investigated using scanning electron microscopy. Wear of carbon-epoxy composite was found to be mainly due to a microcracking and fiber fracture mechanisms. It was found that the microcracking mechanism had been caused by progressive surface damage. Further, it was also noticed that carbon-epoxy composite wear is reduced to a greater extent by addition of the graphite filler, in which wear was dominated by microplowing/microcutting mechanisms instead of microcracking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiwall carbon nanotubes (MWNTs) filled with Fe nanoparticles (NPs) have been synthesized by thermal chemical vapor deposition of ferrocene alone as the precursor. The MWNTs were grown at different temperatures: 980 and 800 degrees C. Characterization of as-prepared MWNTs was done by scanning and transmission electron microscopy, and X-ray diffraction. The transmission electron microscopy study revealed that Fe NPs encapsulated in MWNTs grown at 980 and 800 degrees C are spherical and rod shaped, respectively. Room-temperature vibrating sample magnetometer studies were done on the two samples up to a field of 1T. The magnetization versus magnetic field loop reveals that the saturation magnetization for the two samples varies considerably, almost by a factor of 4.6. This indicates that Fe is present in different amounts in the MWNTs grown at the two different temperatures. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solubility of a drug, n-(4-ethoxyphenyl)ethanamide (phenacetin), in supercritical carbon dioxide was determined by a Saturation method at (308, 318, and 328) K from (9 to 19) MPa. The Solubilities in mole fraction of n-(4-ethoxyphenyl)ethanamide in supercritical carbon dioxide were in the range of 1.29.10(-5) to 2.88.10(-5), 1.13.10(-5) to 3.65.10(-5), and 0.91.10(-5) to 4.28.10(-5) at (308, 3 18, and 328) K, respectively. The solubility data were correlated with the Peng-Robinson equation of state models and the Mendez-Santiago and Teja model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the photoemission from quantum wells (QWs) in ultrathin films (UFs) and quantum well wires (QWWs) of non-linear optical materials on the basis of a newly formulated electron dispersion law considering the anisotropies of the effective electron masses, the spin-orbit splitting constants and the presence of the crystal field splitting within the framework of k.p formalism. The results of quantum confined Ill-V compounds form the special cases of our generalized analysis. The photoemission has also been studied for quantum confined II-VI, n-GaP, n-Ge, PtSb2, stressed materials and Bismuth on the basis of respective dispersion relations. It has been found taking quantum confined CdGeAS(2), InAs, InSb, CdS, GaP, Ge, PtSb2, stressed n-InSb and B1 that the photoemission exhibits quantized variations with the incident photon energy, changing electron concentration and film thickness, respectively, for all types of quantum confinement. The photoemission from CNs exhibits oscillatory dependence with increasing normalized electron degeneracy and the signature of the entirely different types of quantum systems are evident from the plots. Besides, under certain special conditions, all the results for all the materials gets simplified to the well-known expression of photoemission from non-degenerate semiconductors and parabolic energy bands, leading to the compatibility test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the R-T measurement of carbon nanotube bundles from room temperature down to 1 K. The resistance at a particular temperature depends on the diameter of the bundle. The larger the bundle diameter is, the lower the value of the resistance. The resistance increases with the decrease in temperature as in the case of carbon, carbon glass resistance thermometer, and carbon nanotubes reported in the literature. The rate of the variation of resistance depends on the resistance of the bundle at room temperature which can be explored for the low temperature thermometry. Overall, the resistance and the sensitivity of the bundle depend on the bundle diameter which can be monitored easily.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon nanofibers of 50–500 nm diameter and several micrometer length were synthesized by high-temperature pyrolysis of dihydro-2,5-furandione (C4H4O3) in the temperature range of 600–980 °C. The formation of both graphitic and non-graphitic structured carbon fibers was observed in high-resolution transmission electron microscope. The Raman spectra of the samples showed the presence of both the D and G bands of varying intensity and sharpness. The low-temperature electrical transport studies on the samples have shown interesting metal–insulator transitions. The films showed variable range hopping conduction in the insulating regime and power law behavior in the critical regime at low temperatures.