967 resultados para Interfaces classiques-quantiques
Resumo:
Background: It remains unclear as to whether or not dental bleaching affects the bond strength of dentin/resin restoration. Purpose: To evaluated the bond strength of adhesive systems to dentin submitted to bleaching with 38% hydrogen peroxide (HP) activated by LED-laser and to assess the adhesive/dentin interfaces by means of SEM. Study design: Sixty fragments of dentin (25 mm(2)) were included and divided into two groups: bleached and unbleached. HP was applied for 20 s and photoactivated for 45 s. Groups were subdivided according to the adhesive systems (n = 10): (1) two-steps conventional system (Adper Single Bond), (2) two-steps self-etching system (Clearfil standard error (SE) Bond), and (3) one-step self-etching system (Prompt L-Pop). The specimens received the Z250 resin and, after 24 h, were submitted to the bond strength test. Additional 30 dentin fragments (n = 5) received the same surface treatments and were prepared for SEM. Data were analyzed by ANOVA and Tukey`s test (alpha = 0.05). Results: There was significant strength reduction in bleached group when compared to unbleached group (P < 0.05). Higher bond strength was observed for Prompt. Single Bond and Clearfil presented the smallest values when used in bleached dentin. SEM analysis of the unbleached specimens revealed long tags and uniform hybrid layer for all adhesives. In bleached dentin, Single Bond provided open tubules and with few tags, Clearfil determined the absence of tags and hybrid layer, and Prompt promoted a regular hybrid layer with some tags. Conclusions: Prompt promoted higher shear bond strength, regardless of the bleaching treatment and allowed the formation of a regular and fine hybrid layer with less deep tags, when compared to Single Bond and Clearfil. Microsc. Res. Tech. 74:244-250, 2011. (C) 2010 Wiley-Liss, Inc.
Resumo:
Bond failures at the acrylic teeth and denture base resin interface are still a common clinical problem in prosthodontics. The effect of methyl methacrylate (MMA) monomer on the bond strength of three types of denture base resins (Acron MC, Lucitone 550 and QC-20) to two types of acrylic teeth (Biotone and Trilux) was evaluated. Twenty specimens were produced for each denture base resin/acrylic tooth combination and were randomly divided into control (acrylic teeth received no surface treatment) and experimental groups (MMA was applied to the surface of the acrylic teeth for 180 s) and were submitted to shear tests (1 mm/mm). Data (MPa) were analyzed using three-way ANOVA/Student`s test (alpha = 0.05). MMA increased the bond strength of Lucitone denture base resins and decreased the bond strength of QC-20. No difference was detected for the bond strength of Acron MC base resin after treatment with MMA. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Concerns have been raised about the reproducibility of brachial artery reactivity (BAR), because subjective decisions regarding the location of interfaces may influence the measurement of very small changes in lumen diameter. We studied 120 consecutive patients with BAR to address if an automated technique could be applied, and if experience influenced reproducibility between two observers, one experienced and one inexperienced. Digital cineloops were measured automatically, using software that measures the leading edge of the endothelium and tracks this in sequential frames and also manually, where a set of three point-to-point measurements were averaged. There was a high correlation between automated and manual techniques for both observers, although less variability was present with expert readers. The limits of agreement overall for interobserver concordance were 0.13 +/-0.65 mm for the manual and 0.03 +/-0.74 mm for the automated measurement. For intraobserver concordance, the limits of agreement were -0.07 +/-0.38 mm for observer 1 and -0.16 +/-0.55 mm for observer 2. We concluded that BAR measurements were highly concordant between observers, although more concordant using the automated method, and that experience does affect concordance. Care must be taken to ensure that the same segments are measured between observers and serially.
Resumo:
As the use of technological devices in everyday environments becomes more prevalent, it is clear that access to these devices has become an important aspect of occupational performance. Children are increasingly required to competently manipulate technology such as the computer to fulfil occupational roles of student and player. Occupational therapists are in a position to facilitate the successful interface between children and standard computer technologies. The literature has supported the use of direct manipulation interfaces in computing that requires mastery of devices such as the mouse. Identification of children likely to experience difficulties with mouse use will inform the development of appropriate methods of intervention promoting mouse skill and further enhance participation in occupational tasks. The aim of this paper is to discuss the development of an assessment of mouse proficiency for children. It describes the construction of the assessment, the content of the test, and its content validity.
Resumo:
In this paper we establish a foundation for understanding the instrumentation needs of complex dynamic systems if ecological interface design (EID)-based interfaces are to be robust in the face of instrumentation failures. EID-based interfaces often include configural displays which reveal the higher-order properties of complex systems. However, concerns have been expressed that such displays might be misleading when instrumentation is unreliable or unavailable. Rasmussen's abstraction hierarchy (AH) formalism can be extended to include representations of sensors near the functions or properties about which they provide information, resulting in what we call a sensor-annotated abstraction hierarchy. Sensor-annotated AHs help the analyst determine the impact of different instrumentation engineering policies on higher-order system information by showing how the data provided from individual sensors propagates within and across levels of abstraction in the AH. The use of sensor-annotated AHs with a configural display is illustrated with a simple water reservoir example. We argue that if EID is to be effectively employed in the design of interfaces for complex systems, then the information needs of the human operator need to be considered at the earliest stages of system development while instrumentation requirements are being formulated. In this way, Rasmussen's AH promotes a formative approach to instrumentation engineering. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Distance learners are self-directed learners traditionally taught via study books, collections of readings, and exercises to test understanding of learning packages. Despite advances in e-Learning environments and computer-based teaching interfaces, distance learners still lack opportunities to participate in exercises and debates available to classroom learners, particularly through non-text based learning techniques. Effective distance teaching requires flexible learning opportunities. Using arguments developed in interpretation literature, we argue that effective distance learning must also be Entertaining, Relevant, Organised, Thematic, Involving and Creative—E.R.O.T.I.C. (after Ham, 1992). We discuss an experiment undertaken with distance learners at The University of Queensland Gatton Campus, where we initiated an E.R.O.T.I.C. external teaching package aimed at engaging distance learners but using multimedia, including but not limited to text-based learning tools. Student responses to non-text media were positive.
Resumo:
This paper delineates the development of a prototype hybrid knowledge-based system for the optimum design of liquid retaining structures by coupling the blackboard architecture, an expert system shell VISUAL RULE STUDIO and genetic algorithm (GA). Through custom-built interactive graphical user interfaces under a user-friendly environment, the user is directed throughout the design process, which includes preliminary design, load specification, model generation, finite element analysis, code compliance checking, and member sizing optimization. For structural optimization, GA is applied to the minimum cost design of structural systems with discrete reinforced concrete sections. The design of a typical example of the liquid retaining structure is illustrated. The results demonstrate extraordinarily converging speed as near-optimal solutions are acquired after merely exploration of a small portion of the search space. This system can act as a consultant to assist novice designers in the design of liquid retaining structures.
Resumo:
This paper describes a coupled knowledge-based system (KBS) for the design of liquid-retaining structures, which can handle both the symbolic knowledge processing based on engineering heuristics in the preliminary synthesis stage and the extensive numerical crunching involved in the detailed analysis stage. The prototype system is developed by employing blackboard architecture and a commercial shell VISUAL RULE STUDIO. Its present scope covers design of three types of liquid-retaining structures, namely, a rectangular shape with one compartment, a rectangular shape with two compartments and a circular shape. Through custom-built interactive graphical user interfaces, the user is directed throughout the design process, which includes preliminary design, load specification, model generation, finite element analysis, code compliance checking and member sizing optimization. It is also integrated with various relational databases that provide the system with sectional properties, moment and shear coefficients and final member details. This system can act as a consultant to assist novice designers in the design of liquid-retaining structures with increase in efficiency and optimization of design output and automated record keeping. The design of a typical example of the liquid-retaining structure is also illustrated. (C) 2003 Elsevier B.V All rights reserved.
Resumo:
Histidines 107 and 109 in the glycine receptor ( GlyR) alpha(1) subunit have previously been identified as determinants of the inhibitory zinc-binding site. Based on modeling of the GlyR alpha(1) subunit extracellular domain by homology to the acetylcholine-binding protein crystal structure, we hypothesized that inhibitory zinc is bound within the vestibule lumen at subunit interfaces, where it is ligated by His(107) from one subunit and His(109) from an adjacent subunit. This was tested by co-expressing alpha(1) subunits containing the H107A mutation with alpha(1) subunits containing the H109A mutation. Although sensitivity to zinc inhibition is markedly reduced when either mutation is individually incorporated into all five subunits, the GlyRs formed by the co-expression of H107A mutant subunits with H109A mutant subunits exhibited an inhibitory zinc sensitivity similar to that of the wild type alpha(1) homomeric GlyR. This constitutes strong evidence that inhibitory zinc is coordinated at the interface between adjacent alpha(1) subunits. No evidence was found for beta subunit involvement in the coordination of inhibitory zinc, indicating that a maximum of two zinc-binding sites per alpha(1)beta receptor is sufficient for maximal zinc inhibition. Our data also show that two zinc-binding sites are sufficient for significant inhibition of alpha(1) homomers. The binding of zinc at the interface between adjacent alpha(1) subunits could restrict intersubunit movements, providing a feasible mechanism for the inhibition of channel activation by zinc.
Resumo:
The potential applications of macrocycles in chemistry and at its interfaces with biology and physics continue to emerge, one of which is as receptors for small molecules and ions. This review illustrates these applications with examples from the last ten years employing complexation as the binding mechanism; some of the systems presented have already found real-world sensor applications. In any case, the challenges remain to design more selective and sensitive receptors for guests.
Resumo:
O artigo analisa, de forma introdut??ria, as mudan??as na pol??tica na ??rea de sa??de no Brasil. A partir de uma breve retomada de alguns estudos que discutem o papel do Estado na provis??o, financiamento e regula????o do setor sa??de, a autora procura estabelecer pontes ou interfaces entre estes modelos te??ricos e o processo hist??rico mais recente, que deu origem ao Sistema ??nico de Sa??de ??? SUS. Finalmente, a autora discute o que mudou e o que ainda permanece, e se mant??m como tra??o caracter??stico do sistema de sa??de brasileiro.
Resumo:
Esta dissertação apresenta o desenvolvimento de uma plataforma multimodal de aquisição e processamento de sinais. O projeto proposto insere-se no contexto do desenvolvimento de interfaces multimodais para aplicação em dispositivos robóticos cujo propósito é a reabilitação motora adaptando o controle destes dispositivos de acordo com a intenção do usuário. A interface desenvolvida adquire, sincroniza e processa sinais eletroencefalográficos (EEG), eletromiográficos (EMG) e sinais provenientes de sensores inerciais (IMUs). A aquisição dos dados é feita em experimentos realizados com sujeitos saudáveis que executam tarefas motoras de membros inferiores. O objetivo é analisar a intenção de movimento, a ativação muscular e o início efetivo dos movimentos realizados, respectivamente, através dos sinais de EEG, EMG e IMUs. Para este fim, uma análise offline foi realizada. Nessa análise, são utilizadas técnicas de processamento dos sinais biológicos e técnicas para processar sinais provenientes de sensores inerciais. A partir destes, os ângulos da articulação do joelho também são aferidos ao longo dos movimentos. Um protocolo experimental de testes foi proposto para as tarefas realizadas. Os resultados demonstraram que o sistema proposto foi capaz de adquirir, sincronizar, processar e classificar os sinais combinadamente. Análises acerca da acurácia dos classificadores utilizados mostraram que a interface foi capaz de identificar intenção de movimento em 76, 0 ± 18, 2% dos movimentos. A maior média de tempo de antecipação ao movimento foi obtida através da análise do sinal de EEG e foi de 716, 0±546, 1 milisegundos. A partir da análise apenas do sinal de EMG, este valor foi de 88, 34 ± 67, 28 milisegundos. Os resultados das etapas de processamento dos sinais biológicos, a medição dos ângulos da articulação, bem como os valores de acurácia e tempo de antecipação ao movimento se mostraram em conformidade com a literatura atual relacionada.
Resumo:
Novas ferramentas de Tecnologias Assistivas (TAs) têm aparecido ultimamente. Um exemplo são os Ambientes Virtuais (AVs), os quais são importantes para o desenvolvimento de novas TAs, que podem ser direcionadas para promoverem uma melhor qualidade de vida de pessoas com mobilidade reduzida permanente ou promover a reabilitação de pessoas com deficiência motora temporária. Outras ferramentas, que surgiram há algumas décadas com o desenvolvimento dos computadores, também ajudam no tratamento de pessoas com deficiência motora, que são as Interfaces Humano-Máquina (IHM). Utilizando em conjunto com equipamentos que capturam sinais biológicos, como equipamentos de Eletromiografia (EMG) e Eletroencefalografia (EEG), essas ferramentas se configuram como canais de comunicações entre o ser humano e os computadores, diferentemente das comumente utilizadas. Isso abre uma gama de possibilidades para sua utilização no tratamento e na assistência de pessoas com deficiência motora, onde sinais EMG podem ser utilizados para controlar próteses robóticas; e sinais EEG, quando capturados da região do córtex motor, podem ser utilizados em neuroreabilitação. Por outro lado, quando capturados na região occipital, os sinais de EEG podem ser utilizados para gerar comandos e outras finalidades. Este trabalho apresenta o desenvolvimento de novas ferramentas para auxiliar em pesquisas de TAs envolvendo sinais biológicos. Três diferentes AVs foram desenvolvidos para auxiliar nesse tipo de pesquisa. Além deles, um equipamento EEG comercial foi adaptado para ser utilizado com uma IHM, o qual utiliza dois desses três AVs desenvolvidos. Como resultados, temos a utilização bem sucedida do equipamento EEG obtido com sua utilização com SSVEP e Imaginação motora, além da implementação com sucesso dos três AVs desenvolvidos, que estão disponíveis para download gratuito, e que podem ser utilizados em demais pesquisas envolvendo TAs.
Resumo:
A proteção ambiental está conectada à proteção do ser humano, o que implica na busca de interfaces entre os dois regimes, sendo esse o objetivo do presente artigo. A convergência entre meio ambiente e direitos humanos será esboçada a partir das origens do direito internacional ambiental, prosseguindo pela análise dos instrumentos internacionais, tentando-se evidenciar que ambos os sistemas representam um interesse comum da humanidade.
Resumo:
Recent progresses in the software development world has assisted a change in hardware from heavy mainframes and desktop machines to unimaginable small devices leading to the prophetic "third computing paradigm", Ubiquitous Computing. Still, this novel unnoticeable devices lack in various capabilities, like computing power, storage capacity and human interface. Connectivity associated to this devices is also considered an handicap which comes generally associated expensive and limited protocols like GSM and UMTS. Considering this scenario as background, this paper presents a minimal communication protocol introducing better interfaces for limited devices. Special attention has been paid to the limitations of connectivity, storage capacity and scalability of the developed software applications. Illustrating this new protocol, a case-study is presented addressing car sensors communicating with a central