973 resultados para Implantable Infusion pumps
Resumo:
Tese de Doutoramento (Programa Doutoral em Engenharia de Materiais)
Resumo:
OBJECTIVE: To assess the hemodynamic and vasodilating effects of milrinone lactate (ML) in patients with dilated cardiomyopathy (DCM) and New York Heart Association (NYHA) class III and IV heart failure. METHODS: Twenty patients with DCM and NYHA class III and IV heart failure were studied. The hemodynamic and vasodilating effects of ML, administered intravenously, were evaluated. The following variables were compared before and during drug infusion: cardiac output (CO) and cardiac index (CI); pulmonary capillary wedge pressure (PCWP); mean aortic pressure (MAP); mean pulmonary artery pressure (MPAP); mean right atrial pressure (MRAP); left ventricular systolic and end-diastolic pressures (LVSP and LVEDP, respectively); peak rate of left ventricular pressure rise (dP/dt); systemic vascular resistance (SVR); pulmonary vascular resistance (PVR); and heart rate (HR). RESULTS: All patients showed a significant improvement of the analysed parameters of cardiac performance with an increase of CO and CI; a significant improvement in myocardial contractility (dP/dt) and reduction of the LVEDP; PCWP; PAP; MAP; MRAP; SVR; PVR. Were observed no significant increase in HR occurred. CONCLUSION: Milrinone lactate is an inotropic dilating drug that, when administered intravenously, has beneficial effects on cardiac performance and myocardial contractility. It also promotes reduction of SVR and PVR in patients with DCM and NYHA class III and IV of heart failure.
Resumo:
Cardiopulmonary arrest is a medical emergency in which the lapse of time between event onset and the initiation of measures of basic and advanced support, as well as the correct care based on specific protocols for each clinical situation, constitute decisive factors for a successful therapy. Cardiopulmonary arrest care cannot be restricted to the hospital setting because of its fulminant nature. This necessitates the creation of new concepts, strategies and structures, such as the concept of life chain, cardio-pulmonary resuscitation courses for professionals who work in emergency medical services, the automated external defibrillator, the implantable cardioverter-defibrillator, and mobile intensive care units, among others. New concepts, strategies and structures motivated by new advances have also modified the treatment and improved the results of cardiopulmonary resuscitation in the hospital setting. Among them, we can cite the concept of cerebral resuscitation, the application of the life chain, the creation of the universal life support algorithm, the adjustment of drug doses, new techniques - measure of the end-tidal carbon dioxide levels and of the coronary perfusion pressure - and new drugs under research.
Resumo:
It has been reported that growth hormone may benefit selected patients with congestive heart failure. A 63-year-old man with refractory congestive heart failure waiting for heart transplantation, depending on intravenous drugs (dobutamine) and presenting with progressive worsening of the clinical status and cachexia, despite standard treatment, received growth hormone replacement (8 units per day) for optimization of congestive heart failure management. Increase in both serum growth hormone levels (from 0.3 to 0.8 mg/l) and serum IGF-1 levels (from 130 to 300ng/ml) was noted, in association with clinical status improvement, better optimization of heart failure treatment and discontinuation of dobutamine infusion. Left ventricular ejection fraction (by MUGA) increased from 13 % to 18 % and to 28 % later, in association with reduction of pulmonary pressures and increase in exercise capacity (rise in peak VO2 to 13.4 and to 16.2ml/kg/min later). The patient was "de-listed" for heart transplantation. Growth hormone may benefit selected patients with refractory heart failure.
Resumo:
OBJECTIVE: To evaluate the sphygmomanometers calibration accuracy and the physical conditions of the cuff-bladder, bulb, pump, and valve. METHODS: Sixty hundred and forty five aneroid sphygmomanometers were evaluated, 521 used in private practice and 124 used in hospitals. Aneroid manometers were tested against a properly calibrated mercury manometer and were considered calibrated when the error was <=3mm Hg. The physical conditions of the cuffs-bladder, bulb, pump, and valve were also evaluated. RESULTS: Of the aneroid sphygmomanometers tested, 51% of those used in private practice and 56% of those used in hospitals were found to be not accurately calibrated. Of these, the magnitude of inaccuracy ranged from 4 to 8mm Hg in 70% and 51% of the devices, respectively. The problems found in the cuffs - bladders, bulbs, pumps, and valves of the private practice and hospital devices were bladder damage (34% vs. 21%, respectively), holes/leaks in the bulbs (22% vs. 4%, respectively), and rubber aging (15% vs. 12%, respectively). Of the devices tested, 72% revealed at least one problem interfering with blood pressure measurement accuracy. CONCLUSION: Most of the manometers evaluated, whether used in private practice or in hospitals, were found to be inaccurate and unreliable, and their use may jeopardize the diagnosis and treatment of arterial hypertension.
Resumo:
OBJECTIVE - To evaluate the Coronary Flow Reserve in the Coronary Sinus through transesophageal Doppler echocardiography in normal subjects. METHODS - We obtained technically adequate flow samples for analysis in 10 healthy volunteers (37±8 years, 5 men) with no history of heart or systemic disease and with mean left ventricular mass index by transthoracic echocardiography of 87±18 g/m². Coronary sinus flow velocity was recorded within the coronary sinus with the patient in a resting condition and during intravenous adenosine infusion at a dose of 140 µg/kg/min for 4 minutes. Recording of coronary sinus blood flow was possible in all cases with measurement of peak systolic, diastolic, and retrograde velocities (PSV, PDV, and PRV, cm/sec), mean systolic and diastolic velocities (MSV and MDV, cm/sec), and systolic and diastolic velocity time integral (VTI S and VTI D, cm/sec). RESULTS - The coronary flow reserve was calculated as the ratio between the blood flow in the basal state and the maximum measured hyperemic blood flow with adenosine infusion. Results are shown as mean and standard deviations. (CFR = PSV + PDV -- PRV/basal PSV): 1st min = 2.2±0.21; 2nd min = 3±0.3; 3rd min = 3.4±0.37; 4th min = 3.6 ± 0.33. CONCLUSION - Although coronary sinus flow had significantly increased in the first minute, higher velocities were seen at third and fourth minutes, indicating that these should be the best times to study coronary sinus flow with intravenous adenosine in continuous infusion.
Resumo:
OBJECTIVE: To characterize the cardiac electrophysiologic effects of cocaine. METHODS: In 8 dogs (9-13 kg), electrophysiologic parameters and programmed stimulation were undertaken using transvenous catheters at baseline, and after cocaine intravenous infusion (12 mg/kg bolus followed by 0.22 mg/kg/min for 25 minutes). RESULTS: Cocaine plasma levels (n=5) rose to 6.73± 0.56 mg/mL. Cocaine did not affect sinus cycle length and arterial pressure. Cocaine prolonged P wave duration (54±6 vs 73±4 ms, P<0.001), PR interval (115±17 vs 164±15 ms, P<0.001), QRS duration (62±10 vs 88±14 ms, P<0.001), and QTc interval (344±28 vs 403±62 ms, P=0.03) but not JT interval (193±35 vs 226±53 ms, NS). Cocaine prolonged PA (9±6 vs 23±8 ms, P<0.001), AH (73±16 vs 92±15 ms; P=0.03), and HV (35±5 vs 45±3ms; P<0.001) intervals and Wenckebach point (247±26 vs 280±28 ms, P=0.04). An increase occurred in atrial (138±8 vs 184± 20 ms; P<0.001) and ventricular (160±15 vs 187±25 ms; P=0.03) refractoriness at a cycle length of 300 ms. Atrial arrhythmias were not induced in any dog. Ventricular fibrillation (VF) was induced in 2/8 dogs at baseline and 4/8 dogs after cocaine. CONCLUSION: High doses of cocaine exert significant class I effects and seem to enhance inducibility of VF but not of atrial arrhythmias.
Resumo:
OBJECTIVE: To assess the acute effects of high glucose concentrations on vascular reactivity in the isolated non diabetic rabbit kidney. METHODS: Rabbits were anaesthetized for isolation of the kidneys. Renal arteries and veins were cannulated for perfusion with Krebs-Henselleit solution and measurement of perfusion pressure. After 3 hours of perfusion with glucose 5,5 mM (control ) and 15 mM, the circulation was submitted to sub maximal precontraction (80% of maximal response) trough continuous infusion of noradrenaline 10 mM. Vascular reactivity was then assessed trough dose-responses curves with endothelium-dependent (acetylcholine) and independent (sodium nitroprusside) vasodilators. The influence of hyperosmolarity was analyzed with perfusion with mannitol 15mM. RESULTS: A significant reduction in the endothelium-dependent vasodilation in glucose 15mM group was observed compared to that in control, but there was no difference in endothelium-independent vasodilation. After perfusion with mannitol 15 mM, a less expressive reduction in endothelium-dependent vasodilation was observed, only reaching significance in regard to the greatest dose of acetylcholine. CONCLUSION: High levels of glucose similar to those found in diabetic patients in the postprandial period can cause significant acute changes in renal vascular reactivity rabbits. In diabetic patients these effects may also occur and contribute to diabetes vascular disease.
Resumo:
OBJECTIVE: To assess the short- and long-term results of the use of streptokinase (SK) for the treatment of thromboses in cardiac valvular prostheses. METHODS: Seventeen patients with cardiac prosthetic thrombosis diagnosed by clinical, echocardiographic, and radioscopic findings underwent fibrinolytic treatment with a streptokinase bolus of 250,000 U followed by 100.000 U/hour. Short- and long-term results were assessed by radioscopy and echocardiography. RESULTS: Of the 17 patients, 12 had mechanical double-disk prostheses (4 aortic, 6 mitral, 2 tricuspid), 4 had single-disk prostheses (2 aortic, 1 mitral, and 1 tricuspid), and 1 had a tricuspid bioprosthesis. The success rate was 64.8%, the partial success rate was 17.6%, and the nonsuccess rate was 17.6%. All patients with a double-disk prosthesis responded, completely or partially, to the treatment. None of the patients with a single-disk prosthesis had complete resolution of the thrombosis. The time of streptokinase infusion ranged from 6 to 80 hours (mean of 56 h). The mortality rate due to the use of streptokinase was 5.8% and was secondary to cerebral bleeding. During streptokinase infusion, 3 (17.6%) embolic episodes occurred as follows: 1 cerebral, 1 peripheral, and 1 coronary. The rethrombosis index was 33% in a mean follow-up of 42 months. CONCLUSION: The use of fibrinolytic agents was effective and relatively safe in patients with primary thrombosis of a double-disk prosthesis. A fatal hemorrhagic complication occurred in 1 (5.8%) patient, and embolic complications occurred in 3 (17.6%) patients. In a mean 42-month follow-up, 67% of the patients were free from rethrombosis.
Resumo:
FUNDAMENTO: A levosimendana é um novo agente inodilatador que aumenta a contratilidade cardíaca pela sensibilização ao Ca(2+) e induz vasodilatação por meio da ativação dos canais KATP/BKCa. OBJETIVO: Estudar a eficácia e segurança da levosimendana em uma coorte brasileira portadora de insuficiência cardíaca descompensada e em pacientes resistentes a agonistas b-adrenérgicos. MÉTODOS: O BELIEF (Brazilian Evaluation of Levosimendan Infusion Efficacy) foi um estudo aberto, prospectivo, multicêntrico e observacional realizado com 182 portadores de ICD de alto risco, todos tratados com levosimendana. O desfecho primário do estudo era alta hospitalar sem terapia inotrópica adicional (pacientes que responderam ao tratamento). Os desfechos secundários eram alterações nos parâmetros clínicos e hemodinâmicos e nos níveis de peptídeo natriurético cerebral (BNP). RESULTADOS: A taxa de mortalidade foi de 14,8%, e 139 dos 182 pacientes responderam ao tratamento. Entre os que não responderam, a taxa de mortalidade foi de 62,8%. A pressão arterial sistólica foi um preditor de resposta ao tratamento. No grupo resistente aos agonistas b-adrenérgicos, 55,8% responderam ao tratamento. Ao todo, 54 pacientes tiveram pelo menos um evento adverso, a maioria dos quais desapareceu espontaneamente ou após redução da dose da levosimendana. Houve uma melhora significativa na qualidade de vida entre 2 e 6 meses do acompanhamento (p < 0,0001). CONCLUSÃO: Nossos resultados indicam que a infusão de levosimendana é uma terapia alternativa de curto prazo para tratamento de pacientes com ICD. A gravidade da insuficiência cardíaca pode influenciar a resposta ao tratamento com levosimendana. São necessários estudos prospectivos com uma coorte brasileira que inclua também pacientes com doença de Chagas.
Resumo:
Driven by concerns about rising energy costs, security of supply and climate change a new wave of Sustainable Energy Technologies (SET’s) have been embraced by the Irish consumer. Such systems as solar collectors, heat pumps and biomass boilers have become common due to government backed financial incentives and revisions of the building regulations. However, there is a deficit of knowledge and understanding of how these technologies operate and perform under Ireland’s maritime climate. This AQ-WBL project was designed to address both these needs by developing a Data Acquisition (DAQ) system to monitor the performance of such technologies and a web-based learning environment to disseminate performance characteristics and supplementary information about these systems. A DAQ system consisting of 108 sensors was developed as part of Galway-Mayo Institute of Technology’s (GMIT’s) Centre for the Integration of Sustainable EnergyTechnologies (CiSET) in an effort to benchmark the performance of solar thermal collectors and Ground Source Heat Pumps (GSHP’s) under Irish maritime climate, research new methods of integrating these systems within the built environment and raise awareness of SET’s. It has operated reliably for over 2 years and has acquired over 25 million data points. Raising awareness of these SET’s is carried out through the dissemination of the performance data through an online learning environment. A learning environment was created to provide different user groups with a basic understanding of a SET’s with the support of performance data, through a novel 5 step learning process and two examples were developed for the solar thermal collectors and the weather station which can be viewed at http://www.kdp 1 .aquaculture.ie/index.aspx. This online learning environment has been demonstrated to and well received by different groups of GMIT’s undergraduate students and plans have been made to develop it further to support education, awareness, research and regional development.
Resumo:
Despite significant therapeutic advancements, heart failure remains a highly prevalent clinical condition associated with significant morbidity and mortality. In 30%-40% patients, the etiology of heart failure is nonischemic. The implantable cardioverter-defibrillator (ICD) is capable of preventing sudden death and decreasing total mortality in patients with nonischemic heart failure. However, a significant number of patients receiving ICD do not receive any kind of therapy during follow-up. Moreover, considering the situation in Brazil and several other countries, ICD cannot be implanted in all patients with nonischemic heart failure. Therefore, there is an urgent need to identify patients at an increased risk of sudden death because these would benefit more than patients at a lower risk, despite the presence of heart failure in both risk groups. In this study, the authors review the primary available methods for the stratification of the risk of sudden death in patients with nonischemic heart failure.
Resumo:
Ziel der vorliegenden Arbeit ist die Optimierung vorhandener Datensatzstrukturen und der damit korrelierenden Konzeptentwicklung eines charakteristischen Referenzdatensatzes pro Baureihe hinsichtlich der 4.Generation der Pumpenauslegungssoftware „Spaix 4 Pumps“. Die spezielle Anwendungssoftware zur Analyse und Bearbeitung KSB spezifischer Datensätze wird durch die Firma VSX - Vogel Software GmbH - bereitgestellt. Grundlegende Eigenschaften dieser Anwendungssoftware werden detailliert beschrieben. Insbesondere zwei wesentliche Spaix-Applikationen stehen für die Datensatzoptimierung zur Verfügung:Das System „Spaix 4 Pumps“ beinhaltet sowohl die Datenerfassung- und pflege als auch die anwenderseitige Auslegung in zwei voneinander unabhängigen Programmen. Es wird geprüft, ob die vorangestellte Datenmigration KSB spezifischer Datensätze unter Nutzung aller Funktionalitäten des o. g. Softwarekonzeptes die programmtechnische Basis für die Erstellung eines Soll-Datensatzes bilden. Kernthema der Arbeit ist nach der Erfassung und Analyse der Ist-Struktur eine Optimierung des vorliegenden Datenbestandes hinsichtlich notwendiger Strukturen für die Verwendung in „Spaix 4 Pumps“. Das von KSB vorgegebene Ziel ist die Reorganisation bzw. Umstellung des gesamten Datenbestandes mithilfe eines dafür entwickelten VBA Makro. Die Umsetzung erfolgt auf Grundlage des zu entwickelnden Referenzdatensatzes. Im Ergebnis der Arbeit wird festgestellt, dass das neue Softwareprodukt weitaus komplexer ist als die Vorläuferversion „Spaix® Classic V2“. Deshalb ist die Erstellung eines spezifischen Soll-Datensatzes gegenwärtig nicht abgeschlossen. Ursachen hierfür liegen in der begrenzten Verfügbarkeit systemrelevanter KSB spezifischer, aber auch VSX spezifischer Datensätze und der eingeschränkten Programmfunktionalitaet.
Resumo:
The infusion used as a beverage and known as tea of Paraguay or male (Ilex paraguarensis, St. Hil.) contains vitamin B (aneurin). 2) Aneurin determinations were made on the infusion commonly used (water extract) and on the complete water and alcohol extracts. The presence of aneurin was detected in both extracts. For quantitative study aneurin was adsorbed from the extracts (pH 3.8-4.0) by means of fuller's earth and kaolin. 3) Animal tests with pigeons and mice (curative, preventive and maintenance of body weight) give positive but inconstant results. No exact quantitative values could be obtained with the animal test. 4) Schopfer-Jung test based on the development of the mould « Phycomyces blakesleeanus, Bgf » showed constant results. Regular growth curves were obtained with the adsorbate of kaolin and fuller's earth. 5) The thiochrome fluorescence test introduced by Jansen was applied to the detection of aneurin in the adsorbate and good results were found which check closely with those encountered by the Schopfer-Jung test. 6) The determinations of aneurin by means of the Phycomyces and thiochrome tests gave values varying from 60 to 280 y per 100 gr. 7) Green leaves are more rich in aneurin than dry ones.
Resumo:
BACKGROUND: Up to 60% of syncopal episodes remain unexplained. We report the results of a standardized, stepwise evaluation of patients referred to an ambulatory clinic for unexplained syncope. METHODS AND RESULTS: We studied 939 consecutive patients referred for unexplained syncope, who underwent a standardized evaluation, including history, physical examination, electrocardiogram, head-up tilt testing (HUTT), carotid sinus massage (CSM) and hyperventilation testing (HYV). Echocardiogram and stress test were performed when underlying heart disease was initially suspected. Electrophysiological study (EPS) and implantable loop recorder (ILR) were used only in patients with underlying structural heart disease or major unexplained syncope. We identified a cause of syncope in 66% of patients, including 27% vasovagal, 14% psychogenic, 6% arrhythmias, and 6% hypotension. Noninvasive testing identified 92% and invasive testing an additional 8% of the causes. HUTT yielded 38%, CSM 28%, HYV 49%, EPS 22%, and ILR 56% of diagnoses. On average, patients with arrhythmic causes were older, had a lower functional capacity, longer P-wave duration, and presented with fewer prodromes than patients with vasovagal or psychogenic syncope. CONCLUSIONS: A standardized stepwise evaluation emphasizing noninvasive tests yielded 2/3 of causes in patients referred to an ambulatory clinic for unexplained syncope. Neurally mediated and psychogenic mechanisms were behind >50% of episodes, while cardiac arrhythmias were uncommon. Sudden syncope, particularly in older patients with functional limitations or a prolonged P-wave, suggests an arrhythmic cause.