817 resultados para High intensity


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The high-intensity interval exercise has been described as an option for increasing physical activity and its use also being suggested in the therapeutic management of many conditions such as diabetes mellitus and heart failure. However, the knowledge of its physiological effects and parameters that can assure greater safety for interval exercise prescription; especially its effect on short- and medium-term (24 hours after exercise) exercise recovery, need to be clarified. This study objective was to evaluate the effect of continuous and interval aerobic exercise on the cardiac autonomic control immediate and medium term (24 hours), by assessing heart rate variability (HRV). The present study is a randomized crossover clinical trial in which healthy young individuals with low level of physical activity had the VFC 24 hours measured by a heart rate sensor and portable accelerometer (3D eMotion HRV, Kuopio, Finland) before and after continuous aerobic exercise (60-70% HR max, 21 min.) and interval exercise (cycle 1 min. 80-90% HR max, 2 min. at 50-60% HR max, duration 21 min.). HRV was measured in the time and frequency domain and the sympathovagal balance determined by the ratio LF / HF. Nonlinear evaluation was calculated by Shannon entropy. The data demonstrated delayed heart rate recovery immediate after exercise and lower HR after 24 hours compared to pre intervention values, especially in the interval exercise group. There was a tendency to higher predominance and representatives index values of sympathetic stimulation during the day in interval exercise group; however, without statistical significance. The study results help to clarify the effects of interval exercise on the 24 hours following interval exercise, setting parameters for prescription and for further evaluation of groups with metabolic and cardiovascular diseases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent studies have shown the importance of the beat-by-beat changes in heart rate influenced by the autonomic nervous system (ANS), or heart rate variability (HRV). The purpose of this study was to examine the lasting effects of hypoxic exercise on HRV, and its influences on substrate usage. Results from this study could lead an increased understanding on this topic. Eight active healthy males (age: 31±11 years; height: 180±7 cm; weight: 83±8 kg; VO₂max (maximal oxygen consumption): 4.4±0.6 L•min⁻¹) underwent normoxic and hypoxic (FᵢO₂= 0.15) conditions during high-intensity interval (HIIT) cycling (70%-high interval, 35%-rest interval). Cycling intensity was determined by a peak power output cycling test. Each experimental session consisted of a basal metabolic rate determination, up to 45-minutes of HIIT cycling, and three 30-minute post-exercise metabolic rate measurements (spanning 3 hours and 15 minutes after exercise). During exercise, RPE was higher (p<0.01) and LAC (lactate) increased (p=0.001) at each point of time in hypoxia, with no change in normoxia. After hypoxic exercise, the SNS/PNS ratio (overall ANS activity) was significantly higher (p<0.01) and significantly decreased through time in both conditions (p<0.01). In addition, a significant interaction between time and conditions (p<0.02) showed a decrease in LAC concentration through time post-hypoxic exercise. The findings showed that a single bout of hypoxic exercise alters ANS activity post-exercise along with shifting substrate partitioning from glycolytic to lipolytic energy production. The significant decrease in LAC concentration post-hypoxic exercise supports the notion that hypoxic HIIT induces a greater muscle glycogen depletion leading to increased fat oxidation to sustain glycogenesis and gluconeogenesis to maintain blood glucose level during recovery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CHAPTER II - This study evaluated the effects of two different types of acute aerobic exercise on the osmotic stability of human erythrocyte membrane and on different hematological and biochemical variables that are associated with this membrane property. The study population consisted of 20 healthy and active men. Participants performed single sessions of two types of exercise. The first session consisted of 60 min of moderate-intensity continuous exercise (MICE). The second session, executed a week later, consisted of high-intensity interval exercise (HIIE) until exhaustion. The osmotic stability of the erythrocyte membrane was represented by the inverse of the salt concentration (1/H50) at the midpoint of the sigmoidal curve of dependence between the absorbance of hemoglobin and the NaCl concentration. The values of 1/H50 changed from 2.29 ± 0.1 to 2.33 ± 0.09 after MICE and from 2.30 ± 0.08 to 2.23 ± 0.12 after HIIE. In MICE has occurred an increase in the mean corpuscular volume, probably due to in vivo lysis of older erythrocytes, with preservation of cells that were larger and more resistant to in vitro lysis. The study showed that a single bout of acute exercise affected the erythrocyte osmotic stability, which increased after MICE and decreased after HIIE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work is an investigation into collimator designs for a deuterium-deuterium (DD) neutron generator for an inexpensive and compact neutron imaging system that can be implemented in a hospital. The envisioned application is for a spectroscopic imaging technique called neutron stimulated emission computed tomography (NSECT).

Previous NSECT studies have been performed using a Van-de-Graaff accelerator at the Triangle Universities Nuclear Laboratory (TUNL) in Duke University. This facility has provided invaluable research into the development of NSECT. To transition the current imaging method into a clinically feasible system, there is a need for a high-intensity fast neutron source that can produce collimated beams. The DD neutron generator from Adelphi Technologies Inc. is being explored as a possible candidate to provide the uncollimated neutrons. This DD generator is a compact source that produces 2.5 MeV fast neutrons with intensities of 1012 n/s (4π). The neutron energy is sufficient to excite most isotopes of interest in the body with the exception of carbon and oxygen. However, a special collimator is needed to collimate the 4π neutron emission into a narrow beam. This work describes the development and evaluation of a series of collimator designs to collimate the DD generator for narrow beams suitable for NSECT imaging.

A neutron collimator made of high-density polyethylene (HDPE) and lead was modeled and simulated using the GEANT4 toolkit. The collimator was designed as a 52 x 52 x 52 cm3 HDPE block coupled with 1 cm lead shielding. Non-tapering (cylindrical) and tapering (conical) opening designs were modeled into the collimator to permit passage of neutrons. The shape, size, and geometry of the aperture were varied to assess the effects on the collimated neutron beam. Parameters varied were: inlet diameter (1-5 cm), outlet diameter (1-5 cm), aperture diameter (0.5-1.5 cm), and aperture placement (13-39 cm). For each combination of collimator parameters, the spatial and energy distributions of neutrons and gammas were tracked and analyzed to determine three performance parameters: neutron beam-width, primary neutron flux, and the output quality. To evaluate these parameters, the simulated neutron beams are then regenerated for a NSECT breast scan. Scan involved a realistic breast lesion implanted into an anthropomorphic female phantom.

This work indicates potential for collimating and shielding a DD neutron generator for use in a clinical NSECT system. The proposed collimator designs produced a well-collimated neutron beam that can be used for NSECT breast imaging. The aperture diameter showed a strong correlation to the beam-width, where the collimated neutron beam-width was about 10% larger than the physical aperture diameter. In addition, a collimator opening consisting of a tapering inlet and cylindrical outlet allowed greater neutron throughput when compared to a simple cylindrical opening. The tapering inlet design can allow additional neutron throughput when the neck is placed farther from the source. On the other hand, the tapering designs also decrease output quality (i.e. increase in stray neutrons outside the primary collimated beam). All collimators are cataloged in measures of beam-width, neutron flux, and output quality. For a particular NSECT application, an optimal choice should be based on the collimator specifications listed in this work.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Duke Free-electron laser (FEL) system, driven by the Duke electron storage ring, has been at the forefront of developing new light source capabilities over the past two decades. In 1999, the Duke FEL demonstrated the first lasing of a storage ring FEL in the vacuum ultraviolet (VUV) region at $194$ nm using two planar OK-4 undulators. With two helical undulators added to the outboard sides of the planar undulators, in 2005 the highest FEL gain ($47.8\%$) of a storage ring FEL was achieved using the Duke FEL system with a four-undulator configuration. In addition, the Duke FEL has been used as the photon source to drive the High Intensity $\gamma$-ray Source (HIGS) via Compton scattering of the FEL beam and electron beam inside the FEL cavity. Taking advantage of FEL's wavelength tunability as well as the adjustability of the energy of the electron beam in the storage ring, the nearly monochromatic $\gamma$-ray beam has been produced in a wide energy range from $1$ to $100$ MeV at the HIGS. To further push the FEL short wavelength limit and enhance the FEL gain in the VUV regime for high energy $\gamma$-ray production, two additional helical undulators were installed in 2012 using an undulator switchyard system to allow switching between the two planar and two helical undulators in the middle section of the FEL system. Using different undulator configurations made possible by the switchyard, a number of novel capabilities of the storage ring FEL have been developed and exploited for a wide FEL wavelength range from infrared (IR) to VUV. These new capabilities will eventually be made available to the $\gamma$-ray operation, which will greatly enhance the $\gamma$-ray user research program, creating new opportunities for certain types of nuclear physics research.

With the wide wavelength tuning range, the FEL is an intrinsically well-suited device to produce lasing with multiple colors. Taking advantage of the availability of an undulator system with multiple undulators, we have demonstrated the first two-color lasing of a storage ring FEL. Using either a three- or four-undulator configuration with a pair of dual-band high reflectivity mirrors, we have achieved simultaneous lasing in the IR and UV spectral regions. With the low-gain feature of the storage ring FEL, the power generated at the two wavelengths can be equally built up and precisely balanced to reach FEL saturation. A systematic experimental program to characterize this two-color FEL has been carried out, including precise power control, a study of the power stability of two-color lasing, wavelength tuning, and the impact of the FEL mirror degradation. Using this two-color laser, we have started to develop a new two-color $\gamma$-ray beam for scientific research at the HIGS.

Using the undulator switchyard, four helical undulators installed in the beamline can be configured to not only enhance the FEL gain in the VUV regime, but also allow for the full polarization control of the FEL beams. For the accelerator operation, the use of helical undulators is essential to extend the FEL mirror lifetime by reducing radiation damage from harmonic undulator radiation. Using a pair of helical undulators with opposite helicities, we have realized (1) fast helicity switching between left- and right-circular polarizations, and (2) the generation of fully controllable linear polarization. In order to extend these new capabilities of polarization control to the $\gamma$-ray operation in a wide energy range at the HIGS, a set of FEL polarization diagnostic systems need to be developed to cover the entire FEL wavelength range. The preliminary development of the polarization diagnostics for the wavelength range from IR to UV has been carried out.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En plus de contribuer à améliorer la santé de façon générale, l’activité physique chronique pourrait modérer le déclin cognitif associé au vieillissement normal et pathologique (Colcombe et Kramer, 2003; Heyn et al., 2004). Plus précisément, la pratique à long terme d’activités cardiovasculaires aurait des effets positifs sur la cognition des ainés et plus particulièrement sur le contrôle attentionnel, un aspect précocement touché au cours du vieillissement (Raz, 2000; Bherer et al., 2008). Toutefois, les mécanismes par lesquels l’exercice physique aigu améliore la cognition demeurent limités. Malgré ses nombreuses implications théoriques et pratiques, la réponse aiguë de l’oxygénation cérébrale à l’exercice physique et sa relation avec la cognition sont trop peu étudiées. Cette thèse se consacre à cette question. Des études récentes en neuro-imagerie chez les jeunes adultes démontrent que la relation entre l’oxygénation cérébrale et l’intensité de l’exercice suit la forme d’un U inversé. Il existe un seuil au-delà duquel l’oxygénation cérébrale diminue avec l’augmentation de l’intensité de l’exercice. Supposant que les performances cognitives dépendent de la disponibilité de l’oxygène cérébral, cette relation en U inversé devrait affecter les performances cognitives. Avant de préciser le rôle exact de l’oxygénation cérébrale sur les fonctions cognitives, nous avons d’abord examiné le temps nécessaire pour que l’oxygénation cérébrale atteigne un état stable et la durée pendant laquelle cette période stable peut être maintenue lors de paliers de sept minutes à une puissance sous-maximale (40%, 60% et 85% de la puissance aérobie maximale). Nos résultats soulignent l’existence d’une relation inverse entre la durée de l’état stable et l’intensité de l’exercice. Suite à cette vérification méthodologique, la prochaine étape a été de tester la possible relation entre l’oxygénation cérébrale, l’intensité de l’exercice et les performances cognitives, au cours du processus de vieillissement. Les résultats de ces études démontrent que la chute de l’oxygénation cérébrale observée lors des exercices de haute intensité est associée avec une diminution des performances cognitives. Les résultats de cette thèse corrigent l’écart existant dans la documentation entre l’exercice, les fonctions cognitives et les mécanismes neurophysiologiques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Indian monsoon system, as recorded by ocean-floor biota (benthic foraminifera) at Ocean Drilling Program Site 758 in the eastern equatorial Indian Ocean, has varied dramatically over the past 5.5 m.y., long after the onset of the monsoons at 10-8 Ma. Benthic foraminifera that thrive with high productivity year-round were common before the formation of Northern Hemisphere continental ice sheets ca. 3.1-2.5 Ma, indicating that the summer (southwest) monsoon had high intensity and long seasonal duration. Ca. 2.8 Ma benthic faunas became dominated by taxa that flourish with a seasonally strongly fluctuating food supply, indicating that the northeast (winter) monsoon, during which primary productivity is relatively low, increased in duration and strength to form a system similar to that of today. The change occurred coeval with the initiation of the Northern Hemisphere glaciation, documenting a close link between the development of the Indian monsoon and Northern Hemisphere glaciation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sprint interval training (SIT) can elicit improvements in aerobic and anaerobic capacity. While variations in SIT protocols have been investigated, the influence of social processes cannot be overlooked. As research supports the use of groups to influence individual cognitions and behaviours, the current project assessed the effectiveness of a group-based intervention with participants conducting SIT. Specifically, 53 amateur athletes (age, 21.9 ± 2.9 years; 53% females) took part in a 4-week training program (3 sessions per week, 30-s “all-out” efforts with 4 min active recovery, repeated 4–6 times per session), and were assigned to “true group”, aggregate, or individual conditions. Results indicated no significant differences between groups for the physiological measures. With regards to training improvements from baseline for all participants— regardless of condition — significant main effects for time were identified for maximal oxygen uptake (2.5–2.8 mL·kg−1·min−1, p < 0.001, η2 = 0.03), time-trial performance (14–32 s, p < 0.001, η2 = 0.37), and anaerobic power (1.1–1.7 k·h−1, p < 0.001, η2 = 0.66). With regards to the psychological measures, significant main effects between groups were found for motivation (p = 0.033, η2 = 0.13), task self-efficacy (p = 0.018, η2 = 0.15), and scheduling self-efficacy (p = 0.003, η2 = 0.22). The true group experienced greater improvements in motivation than the individual condition, but the aggregate and individual conditions demonstrated greater increases in task and scheduling self-efficacy. Though the SIT paradigm employed induced training improvements similar to previous work, the group intervention was not able to further these improvements

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As part of the ultrafast charge dynamics initiated by high intensity laser irradiations of solid targets,high amplitude EM pulses propagate away from the interaction point and are transported along anystalks and wires attached to the target. The propagation of these high amplitude pulses along a thinwire connected to a laser irradiated target was diagnosed via the proton radiography technique,measuring a pulse duration of 20 ps and a pulse velocity close to the speed of light. The strongelectric field associated with the EM pulse can be exploited for controlling dynamically the protonbeams produced from a laser-driven source. Chromatic divergence control of broadband laser drivenprotons (upto 75% reduction in divergence of >5 MeV protons) was obtained by winding the supportingwire around the proton beam axis to create a helical coil structure. In addition to providingfocussing and energy selection, the technique has the potential to post-accelerate the transiting protonsby the longitudinal component of the curved electric field lines produced by the helical coil lens.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Les sources laser à large bande possédant les caractéristiques requises pour émettre sur la plage spectrale correspondant à la seconde fenêtre de transmission atmosphérique (3 à 5 μm) exercent un attrait considérable pour divers domaines tels que la télédétection de polluants atmosphériques et les contremesures infrarouges. Les supercontinua générés à l’intérieur de fibres optiques représentent une option intéressante pour réaliser ce type de sources laser. En effet, ils possèdent une intensité élevée, un large contenu spectral, une excellente directionnalité de faisceau, ainsi qu’un bon potentiel pour constituer des sources lumineuses compactes et robustes. Toutefois, la génération d’un tel supercontinuum implique certains défis à relever sur le plan de la conception des fibres optiques employées. En fait, ces fibres optiques doivent présenter de faibles pertes de propagation sur la plage spectrale de 3 à 5 μm, posséder un paramètre de non-linéarité élevé et permettre le pompage en régime anomal de dispersion à des longueurs d’onde pour lesquelles des sources laser compactes sont offertes commercialement. En matière de robustesse, ces fibres doivent également démontrer de bonnes propriétés mécaniques ainsi qu’une stabilité chimique appropriée vis-à-vis de la corrosion causée par l’humidité. Dans le cadre de cette thèse, un nouveau type de fibres composites à saut d’indice fortement contrasté a été développé pour atteindre ces objectifs de génération de supercontinuum. Ce type de fibres combine respectivement un verre de tellurite et un verre de germanate pour son coeur et sa gaine permettant ainsi d’atteindre une différence d’indice de réfraction d’environ 0.3 entre ces deux dernières structures. Grâce à cet important saut d’indice, ces fibres peuvent fortement confiner les modes optiques à l’intérieur de leur coeur, ce qui leur donne la possibilité d’atteindre un niveau élevé de non-linéarité et d’optimiser leurs caractéristiques de dispersion chromatique pour la génération du supercontinuum. D’autre part, leur section transversale toute solide leur confère aussi une meilleure stabilité environnementale comparativement à celle démontrée par les fibres optiques microstructurées à base de verres d’oxydes de métaux lourds, de verres de chalcogénure et de verres fluorés. Toutefois, leur fabrication nécessite l’appariement de verres dont les propriétés thermomécaniques concordent suffisamment ensemble pour permettre leur fibrage. Les travaux effectués ici démontrent la production de fibres optiques composites et leur potentiel pour la génération du supercontinuum dans l’infrarouge moyen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to identify hypertension (HT) in karate competitors (KCs) in high intensity exercise. Values were compared with an exercise control group (EC). The 84 subjects were randomly divided into two groups: KC and EC. Resting blood pressure (BP) was measured the day before and immediately precompetition. A further three measurements were taken postexercise for all subjects at 1-, 2-, and 8- minute intervals. At rest, day one, mean BP of KC was 134/84 ± 3/2 mmHg vs. EC, 124/72 ± 1/2 mmHg and on day 2, was 141/79 ± 3/2 mmHg vs. EC, 125/72 ± 1/2 mmHg, respectively. Eight minutes postcompetition, BP of KCs was 140/77 ± 2/1 mmHg vs. EC 135/75 ± 2/1 mmHg. High blood pressure (HBP) was recorded in 60.5% of KCs on day 2, and essential HT that required medical therapy was subsequently diagnosed in 5% of KCs. Five percent of EC also had HBP, but subsequent medical examination reported normal values.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente relatório resulta de um estágio realizado no âmbito da eficiência energética assente no programa Galp 20-20-20 que tem por génese uma parceria entre a Universidade de Aveiro e a empresa de coberturas cerâmicas, CS – Coelho da Silva S.A. A Fábrica alvo de estudo é uma consumidora intensiva de energia, despendeu no ano de 2013 cerca de 3.768 tep. Devido aos seus processos de cozedura e secagem, apresenta uma elevada dependência de Gás Natural, representando pouco mais de 78% do consumo global da fábrica. Deste consumo de energia térmica, 83% respeita ao forno e os restantes 17% encontram-se alocados ao secador, pelo que as medidas de eficiência energética presentes neste relatório centram-se da redução deste vetor energético. São então propostas três medidas para a redução da dependência deste vetor. A primeira, incide na recuperação de calor residual presente nos gases de exaustão através da instalação de um permutador de calor. Esta medida permite uma redução do consumo na ordem dos 10% e conta com um payback de 2,3 anos resultante de uma economia anual de 150.000 €. Para este estudo foi desenvolvido um modelo dinâmico em excel que permite a simulação de diversos cenários. São também propostas mais duas intervenções que incidem na alteração do circuito térmico. Estas medidas têm um impacte mais reduzido no que respeita ao percentual de redução energético, ambas com menos de 1% de redução do consumo global da fábrica. Contudo são medidas bastante interessantes dada a sua simplicidade e contam com poupanças anuais na ordem dos 6.000 € que resultam num payback inferior a 2 meses. Paralelamente executaram-se dois estudos para a iluminação, o primeiro sugere a instalação de um modelador de tensão que reduz a potência de iluminação em 36%, implicando uma redução da iluminância de cerca de 5%. A redução da potência resulta numa economia energética na ordem dos 0,4% da energia global da instalação. Este equipamento poderá ser adquirido por completo ou em renting. Ao optar pela compra integral, o investimento será apenas ressarcido em 2,8 anos resultante de uma poupança anula de perto de 6.500 €. Caso seja por renting este não tem qualquer custo adicional e as economias monetárias são partilhadas entre a empresa que fornece o equipamento e a CS-Coelho da Silva, S.A. Por fim é sugerida a substituição de parte da iluminação atual da fábrica por tecnologia LED, com esta medida reduz-se o consumo global em 0,76%. Esta medida gera uma economia monetária na ordem dos 11.500 € sendo ressarcida em 2,1 anos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O crescimento e o desenvolvimento crâniofaciais, apesar de estarem condicionados por fatores genéticos, são fortemente influenciados pelo padrão funcional da musculatura oro-facial. Cada indivíduo apresenta o seu próprio padrão de crescimento que sofre ação de fatores ambientais que em alguns casos podem alterá-lo. A maxila tem o seu crescimento para trás e para cima proporcionando um deslocamento desta para a frente e para baixo. Enquanto que, o crescimento do processo condilar contribui para o crescimento do ramo mandibular para trás e para cima, determinando o seu deslocamento para a frente e para baixo Os problemas de oclusão dentária consistem em anomalias do crescimento e desenvolvimento, afetando principalmente, os dentes, músculos e os ossos maxilares no período da infância e da adolescência, os quais podem produzir alterações tanto do ponto de vista estético como funcional. A amamentação é um fator que tem vindo cada vez mais a ser relacionado com o desenvolvimento crâniofacial, especialmente o crescimento mandibular, pois o mecanismo da amamentação tem sido considerado uma mais-valia na correção do retrognatismo mandibular presente no bebé. O tempo de amamentação é uma condicionante muito importante, visto que, o menor tempo de amamentação leva ao uso precoce do biberão. Este tipo de aleitamento pode não satisfazer o bebé por completo, pois o mecanismo de aleitamento é diferente do de amamentação, e pode potenciar o desenvolvimento de hábitos de sucção não nutritivos, como o uso da chupeta ou sucção digital, que vai prejudicar o desenvolvimento estomatognático, dando origem a más oclusões. Os hábitos de sucção não nutritiva quando instalados e com uma frequência, duração e intensidade elevada podem levar a problemas oclusais que só serão corrigidos ortodonticamente.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose The aim of this study was to test the effects of sprint interval training (SIT) on cardiorespiratory fitness and aerobic performance measures in young females. Methods Eight healthy, untrained females (age 21 ± 1 years; height 165 ± 5 cm; body mass 63 ± 6 kg) completed cycling peak oxygen uptake ( V˙O2V˙O2 peak), 10-km cycling time trial (TT) and critical power (CP) tests pre- and post-SIT. SIT protocol included 4 × 30-s “all-out” cycling efforts against 7 % body mass interspersed with 4 min of active recovery performed twice per week for 4 weeks (eight sessions in total). Results There was no significant difference in V˙O2V˙O2 peak following SIT compared to the control period (control period: 31.7 ± 3.0 ml kg−1 min−1; post-SIT: 30.9 ± 4.5 ml kg−1 min−1; p > 0.05), but SIT significantly improved time to exhaustion (TTE) (control period: 710 ± 101 s; post-SIT: 798 ± 127 s; p = 0.00), 10-km cycling TT (control period: 1055 ± 129 s; post-SIT: 997 ± 110 s; p = 0.004) and CP (control period: 1.8 ± 0.3 W kg−1; post-SIT: 2.3 ± 0.6 W kg−1; p = 0.01). Conclusions These results demonstrate that young untrained females are responsive to SIT as measured by TTE, 10-km cycling TT and CP tests. However, eight sessions of SIT over 4 weeks are not enough to provide sufficient training stimulus to increase V˙O2V˙O2 peak.