950 resultados para Heat storage rate
Resumo:
High removal rate (up to 16.6 mm(3)/s per mm) grinding of alumina and alumina-titania was investigated with respect to material removal and basic grinding parameters using a resin-bond 160 mu m grit diamond wheel at the speeds of 40 and 160 m/s, respectively. The results show that the material removal for the single-phase polycrystalline alumina and the two-phase alumina-titania composite revealed identical mechanisms of microfracture and grain dislodgement under the grinding conditioned selected. There were no distinct differences in surface roughness and morphology for both materials ground at either conventional or high speed. An increase in material removal rate did not necessarily worsen the surface toughness for the two materials at both speeds. Also the grinding forces for the two ceramics demonstrated similar characteristics at any grinding speeds and specific removal rates. Both normal and tangential grinding forces and their force ratios at the high speed were lower than those at the conventional speed, regardless of removal rates. An increase in specific removal rate caused more rapid increases in normal and tangential forces obtained at the conventional grinding speed than those at the high speed. Furthermore, it is found that the high speed grinding at all the removal rates exerted a great amount of coolant-induced normal forces in grinding zone, which were 4-6 times higher than the pure normal grinding forces. (c) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Self-assembled materials consisting of V(2)O(5), polyallylamine (PAR) and silver nanoparticles (AgNPs) were obtained by the layer-by-layer (LbL) method, aiming at their application as electrodes for lithium-ion batteries and electrochromic devices. The method employed herein allowed for linear growth of visually homogeneous films composed of V(2)O(5), V(2)O(5)/PAH, and V(2)O(5)/PAH/AgNP with 15 bilayers. According to the Fourier transform infrared spectra, interaction between the oxygen atom of the vanadyl group and the amino group should be responsible for the growth of these films. This interaction also enabled establishment of an electrostatic shield between the lithium ions and the sites with higher negative charge, thereby raising the ionic mobility and consequently increasing the energy storage capacity and reducing the response time. According to the site-saturation model and the electrochemical and spectroelectrochemical results, the presence of PAH in the self-assembled host matrix decreased the number of V(2)O(5) electroactive sites. Thus, AgNPs were stabilized in PAR and inserted into the nanoarchitecture, so as to enhance the specific capacity. This should provide new conducting pathways and connect isolated V(2)O(5) particles in the host matrix. Therefore, new nanoarchitectures for specific interactions were formed spontaneously and chosen as examples in this work, aiming to demonstrate the potentiality of the adopted self-assembled method for enhancing the charge transport rate into the host matrices. The obtained materials displayed suitable properties for use as electrodes in lithium batteries and electrochromic devices.
Resumo:
This paper reports for the first time superior electric double layer capacitive properties of ordered mesoporous carbon (OMCs) with varying ordered pore symmetries and mesopore structure. Compared to commercially used activated carbon electrode, Maxsorb, these OMC carbons have superior capacitive behavior, power output and high-frequency performance in EDLCs due to the unique structure of their mesopore network, which is more favorable for fast ionic transport than the pore networks in disordered microporous carbons. As evidenced by N-2 sorption, cyclic voltammetry and frequency response measurements, OMC carbons with large mesopores, and especially with 2-D pore symmetry, show superior capacitive behaviors (exhibiting a high capacitance of over 180 F/g even at very high sweep rate of 50 mV/s, as compared to much reduced capacitance of 73 F/g for Maxsorb at the same sweep rate). OMC carbons can provide much higher power density while still maintaining good energy density. OMC carbons demonstrate excellent high-frequency performances due to its higher surface area in pores larger than 3 nm. Such ordered mesoporous carbons (OMCs) offer a great potential in EDLC capacitors, particularly for applications where high power output and good high-frequency capacitive performances are required. (C) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Vascular calcification is a strong prognostic marker of mortality in hemodialysis patients and has been associated with bone metabolism disorders in this population. In earlier stages of chronic kidney disease (CKD), vascular calcification also has been documented. This study evaluated the association between coronary artery calcification (CAC) and bone histomorphometric parameters in CKD predialysis patients assessed by multislice coronary tomography and by undecalcified bone biopsy. CAC was detected in 33 (66%) patients, and their median calcium score was 89.7 (0.4-2299.3 AU). The most frequent bone histologic alterations observed included low trabecular bone volume, increased eroded and osteoclast surfaces, and low bone-formation rate (BFR/BS). Multiple logistic regression analysis, adjusted for age, sex, and diabetes, showed that BFR/BS was independently associated with the presence of coronary calcification [p=.009; odd ratio (OR) = 0.15; 95% confidence interval (Cl) 0.036-0.619] This study showed a high prevalence of CAC in asymptomatic predialysis CKD patients. Also, there was an independent association of low bone formation and CAC in this population. In conclusion, our results provide evidence that low bone-formation rate constitutes another nontraditional risk factor for cardiovascular disease in CKD patients. 2010 American Society for Bone and Mineral Research.
Resumo:
Objective: To investigate the influence of maternal glycemia on fetal heart rate (FHR) parameters analyzed by computerized cardiotocography in fetuses of diabetic mothers in the third trimester. Study design: Thirty-nine pregnant women with pregestational diabetes mellitus were studied prospectively. The inclusion criteria were a diagnosis of pregestational diabetes, singleton pregnancy between 36 and 40 weeks, and absence of fetal abnormalities. Computerized cardiotocography (System 8002) was performed over a period of 60 min and capillary glycemia was measured immediately before and 30 and 60 min after the beginning of the exam. The evaluations were done 2 h after lunch. Results: Nineteen patients (48.7%) presented mean glycemia >= 120 mg/dL The mean basal FHR was 136.7 +/- 10.0 bpm in the group with glycemia <120 mg/dL and 144.8 +/- 9.4 bpm in the group with glycemia >= 120 mg/dL (p = 0.013, Student`s t test). There was a significant positive correlation (Pearson`s test, p = 0.0001, r = 0.57) between basal FHR and mean glycemia. A significant negative correlation was observed between short-term variation and mean glycemia (Pearson`s test, p = 0.003, r = -0.47). No significant differences were observed between the other indices evaluated by computerized cardiotocography and glycemia. Conclusions: Maternal hyperglycemia at the time of cardiotocography is associated with elevated FHR. It seems to be important to understand how FHR parameters are influenced by maternal glycemic status at the time of fetal assessment in pregnancies complicated by diabetes. (C) 2009 Published by Elsevier Ireland Ltd.
Resumo:
Problem We evaluated associations between a length polymorphism in intron 2 of the gene coding for IL-1ra (gene symbol IL1RN) and pregnancy outcome in a population with a high rate of preterm birth. Method of study Subjects were pregnant women in Maceio, Brazil and their newborns. DNA was tested for IL1RN genotypes and alleles by gene amplification using primer pairs that spanned the polymorphic region. Every subject completed a detailed questionnaire. Results The frequency of allele 2 (IL1RN*2) carriage was elevated in mothers with a spontaneous preterm birth (SPTB) in the current pregnancy (P = 0.02) and also with a prior preterm delivery (P = .01). Both SPTB with intact membranes (P = 0.01) and SPTB preceded by pre-term pre-mature rupture of membranes (P = .03) were associated with IL1RN*2 carriage. A previous fetal demise was more than twice as prevalent in mothers positive for two copies of IL1RN*2. Conclusion Maternal carriage of IL1RN*2 increases susceptibility to inflammation-triggered spontaneous pre-term birth.
Resumo:
Background and purpose: To evaluate biochemical control and treatment related toxicity of patients with localized adenocarcinoma of the prostate treated with high dose-rate brachytherapy (HDRB) combined with conventional 2D or 3D-conformal external beam irradiation (EBI). Material and methods: Four-hundred and three patients treated between December 2000 and March 2004. HDRB was delivered with three fractions of 5.5-7 Gy with a single implant, followed by 45 Gy delivered with 2D or 3D conformal EBI. Results: The median follow-up was 48.4 months. Biochemical failure (BF) occurred in 9.6% according to both ASTRO and Phoenix consensus criteria. Mean time to relapse was 13 and 26 months, respectively. The 5-year BF free survival using the ASTRO criteria was 94.3%, 86.9% and 86.6% for the low, intermediate and high risk groups, respectively; using Phoenix criteria, 92.4%, 88.0% and 85.3%, respectively. The only predictive factor of BF in the multivariate analysis by both ASTRO and Phoenix criteria was the presence of prostate nodules detected by digital palpation, and patients younger than 60 years presented a higher chance of failure using Phoenix criteria only. Conclusions: Treatment scheme is feasible and safe with good efficacy. (C) 2011 Elsevier Ireland Ltd All rights reserved. Radiotherapy and Oncology 98 (2011) 169-174
Resumo:
To describe incidence rates and risk factors associated with external ventricular drain (EVD)-related infections at a tertiary Brazilian teaching hospital. The patient cohort consisted of all patients at a major teaching hospital in Brazil with an EVD during the period 1 April 2007 to 30 June 2008 (15 months). Patients were followed up for 30 days after catheter removal. According to the Center for Diseases Control and Prevention criteria for meningitis/ventriculitis, all of the central nervous system (CNS) infections that occurred during this period could be considered to be meningitis or ventriculitis related to EVD placement. Infection rates were calculated using different denominators, such as (1) per patient (incidence), (2) per procedure, and (3) per 1,000 catheter-days (drain-associated infection rate). Patient demographic data, medical history of underlying diseases, antibiotic prophylaxis usage, American Society of Anesthesiologists Score classification, duration of surgery and hospitalization, length of time the EVD was in place, and overall mortality were evaluated during the study period. A logistic regression model was developed to identify factors associated with infection. A total of 119 patients, 130 EVD procedures, and 839 catheter-days were evaluated. The incidence of infection was 18.3%, the infection rate was 16.9% per procedure, and the drain-associated infection rate was 22.4 per 1,000 catheter-days; 77% of the infections were caused by Gram-negative micro-organisms. Only 75% of patients received antibiotic prophylaxis. The infection rate increased with length of the hospital stay. The length of time the catheter was in place was the only independent risk factor associated with infection (p = 0.0369). The incidence of EVD-related infections is high in our hospital, Gram-negative micro-organisms were the most frequent causal agents identified and length of time that the catheter was in place contributed to the infection rate.
Resumo:
Background/Purpose: Central venous catheterization is among the most common procedures performed by pediatric surgeons. Significant morbidity and even mortality can ensue from the widespread approach to the deep veins of the neck and femoral region. The external jugular vein (EJV) is a low-morbidity alternative for percutaneous catheterization in children, but it has yielded a low success rate in previous reports The authors show an improved success rate with this option. Methods: We performed an analysis of 33 patients` charts in which central venous catheterization using Seldinger technique through the EJV was attempted in 2005. Age, diagnosis, maneuvers used for success, fluoroscopy usefulness, and types of inserted catheters were evaluated. Results: The procedure was successful in 26 (78.8%) patients without complications. Diagnosis was neoplasia in almost half of the patients (42%). In half of the successful cases, body maneuvers were used, namely, twisting the head of the patient to the side of the vein and stretching the ipsilateral arm and shoulder. All but one procedure were completed under fluoroscopic guidance. In 6 (23%) patients, a long-term catheter was inserted. Conclusions: The EJV is an excellent option for central venous catheterization in children. The execution of simple maneuvers along with fluoroscopic assistance might allow for an improved success rate not only for short-term but also for long-term catheter insertion. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
In this paper, experiments to detect turbulent spots in the transitional boundary layers, formed on a flat plate in a free-piston shock tunnel how, are reported. Experiments indicate that thin-film heat-transfer gauges are suitable for identifying turbulent-spot activity and can be used to identify parameters such as the convection rate of spots and the intermittency of turbulence.
Resumo:
Purpose: Most groups have reported disappointing results with autoaugmentation or detrusor myectomy for low capacity/compliance neuropathic bladders. Failure may be due to an ischemic diverticulum or mucosal shrinkage. We investigated whether a Silimed (R) silicone balloon placed in the bladder after autoaugmentation could prevent these problems, improving surgical results. Materials and Methods: We compared the results of standard bladder autoaugmentation in 12 children (group 1) with those in 10 (group 2) who underwent the same surgery using a bladder conformer. The conformer was a silicone balloon filled with saline that remained in the bladder for 2 weeks. All patients had a neuropathic bladder with poor capacity and compliance, resulting in urinary leakage between catheterizations. Preoperative and postoperative evaluation included a voiding diary, ultrasound, voiding cystourethrogram and urodynamics. Results: In group 1 only 1 patient became dry, 4 had little improvement in continence, 4 remained unchanged and 3 became worse. In group 2, 6 patients (60%) become continent without medication, 2 (20%) become continent with oxybutynin and 2 remained unchanged. Bladder capacity and compliance did not change significantly in group 1. However, in group 2 capacity changed from a mean of 140 to 240 ml and mean +/- SD compliance increased from 15.6 +/- 16.8 to 34.3 +/- 22.8 ml/cm H(2)O (p = 0.02). Conclusions: The inflatable balloon improved our long-term results of bladder auto-augmentation. A larger series may be necessary to confirm procedure efficacy and safety.
Resumo:
Objectives: Acute pancreatitis (AP) protease release induces lung parenchymal destruction via matrix metalloproteinases (MMPs), a neutrophil (polymorphonuclear leukocyte)-dependent process. Recent studies in hemorrhagic shock revealed that hypertonic saline (HTS) has an anti-inflammatory effect and can inhibit a variety of neutrophil functions. The aim of this study was to determine whether HTS and its actions in the pathway of neutrophil migration, MMPs, and heat shock proteins (HSPs) are effective in protecting the lung from injury associated with AP. Methods: We determined neutrophil infiltration and expressions of MMPs and HSPs in the lung tissue after AP induced by retrograde infusion of 2.5% of sodium taurocholate. Results: Animals submitted to AP that received HTS compared with those who received normal saline presented with increased HSP70 and HSP90 expressions and reduced myeloperoxidase levels and MMP-9 expression and activity. Conclusions: Our data raised the hypothesis that a sequence of HTS lung protection events increases HSP70 and HSP90, inhibiting infiltration of neutrophils and their protease actions in the lung.
Resumo:
An experimental study of the effect of fuel stagnation temperature on mixing in a supersonic hydrogen-air flame is described, The combustor consisted of a constant-area rectangular duct with a centrally located fuel-injection strut that spanned the width. A high-enthalpy stream of air was supplied by a free-piston shock tunnel, and heated hydrogen fuel, supplied by a gun-tunnel, was injected into the freestream as a coflowing planar jet. The freestream total enthalpies were 5.6, 6.5, and 9 MJ/kg, and fuel stagnation temperatures were 300, 450, and 700 K, Raising the fuel stagnation temperature increased the fuel velocity to be near that of the airstream and resulted in a decrease in the mixing rate, Even as the fuel and air velocities became equal, significant mixing still occurred because of a large difference in density, Increasing the freestream enthalpy reduced the difference between the initial air temperature and the adiabatic flame temperature, which in turn reduced the heat addition, and subsequently, the amount of pressure rise in the duct.