948 resultados para Frequency Modulated Signals, Parameter Estimation, Signal-to-Noise-Ratio, Simulations
Resumo:
For wireless power transfer (WPT) systems, communication between the primary side and the pickup side is a challenge because of the large air gap and magnetic interferences. A novel method, which integrates bidirectional data communication into a high-power WPT system, is proposed in this paper. The power and data transfer share the same inductive link between coreless coils. Power/data frequency division multiplexing technique is applied, and the power and data are transmitted by employing different frequency carriers and controlled independently. The circuit model of the multiband system is provided to analyze the transmission gain of the communication channel, as well as the power delivery performance. The crosstalk interference between two carriers is discussed. In addition, the signal-to-noise ratios of the channels are also estimated, which gives a guideline for the design of mod/demod circuits. Finally, a 500-W WPT prototype has been built to demonstrate the effectiveness of the proposed WPT system.
Resumo:
Considering the so-called "multinomial discrete choice" model the focus of this paper is on the estimation problem of the parameters. Especially, the basic question arises how to carry out the point and interval estimation of the parameters when the model is mixed i.e. includes both individual and choice-specific explanatory variables while a standard MDC computer program is not available for use. The basic idea behind the solution is the use of the Cox-proportional hazards method of survival analysis which is available in any standard statistical package and provided a data structure satisfying certain special requirements it yields the MDC solutions desired. The paper describes the features of the data set to be analysed.
Resumo:
Limited literature regarding parameter estimation of dynamic systems has been identified as the central-most reason for not having parametric bounds in chaotic time series. However, literature suggests that a chaotic system displays a sensitive dependence on initial conditions, and our study reveals that the behavior of chaotic system: is also sensitive to changes in parameter values. Therefore, parameter estimation technique could make it possible to establish parametric bounds on a nonlinear dynamic system underlying a given time series, which in turn can improve predictability. By extracting the relationship between parametric bounds and predictability, we implemented chaos-based models for improving prediction in time series. ^ This study describes work done to establish bounds on a set of unknown parameters. Our research results reveal that by establishing parametric bounds, it is possible to improve the predictability of any time series, although the dynamics or the mathematical model of that series is not known apriori. In our attempt to improve the predictability of various time series, we have established the bounds for a set of unknown parameters. These are: (i) the embedding dimension to unfold a set of observation in the phase space, (ii) the time delay to use for a series, (iii) the number of neighborhood points to use for avoiding detection of false neighborhood and, (iv) the local polynomial to build numerical interpolation functions from one region to another. Using these bounds, we are able to get better predictability in chaotic time series than previously reported. In addition, the developments of this dissertation can establish a theoretical framework to investigate predictability in time series from the system-dynamics point of view. ^ In closing, our procedure significantly reduces the computer resource usage, as the search method is refined and efficient. Finally, the uniqueness of our method lies in its ability to extract chaotic dynamics inherent in non-linear time series by observing its values. ^
Resumo:
In this thesis, novel analog-to-digital and digital-to-analog generalized time-interleaved variable bandpass sigma-delta modulators are designed, analysed, evaluated and implemented that are suitable for high performance data conversion for a broad-spectrum of applications. These generalized time-interleaved variable bandpass sigma-delta modulators can perform noise-shaping for any centre frequency from DC to Nyquist. The proposed topologies are well-suited for Butterworth, Chebyshev, inverse-Chebyshev and elliptical filters, where designers have the flexibility of specifying the centre frequency, bandwidth as well as the passband and stopband attenuation parameters. The application of the time-interleaving approach, in combination with these bandpass loop-filters, not only overcomes the limitations that are associated with conventional and mid-band resonator-based bandpass sigma-delta modulators, but also offers an elegant means to increase the conversion bandwidth, thereby relaxing the need to use faster or higher-order sigma-delta modulators. A step-by-step design technique has been developed for the design of time-interleaved variable bandpass sigma-delta modulators. Using this technique, an assortment of lower- and higher-order single- and multi-path generalized A/D variable bandpass sigma-delta modulators were designed, evaluated and compared in terms of their signal-to-noise ratios, hardware complexity, stability, tonality and sensitivity for ideal and non-ideal topologies. Extensive behavioural-level simulations verified that one of the proposed topologies not only used fewer coefficients but also exhibited greater robustness to non-idealties. Furthermore, second-, fourth- and sixth-order single- and multi-path digital variable bandpass digital sigma-delta modulators are designed using this technique. The mathematical modelling and evaluation of tones caused by the finite wordlengths of these digital multi-path sigmadelta modulators, when excited by sinusoidal input signals, are also derived from first principles and verified using simulation and experimental results. The fourth-order digital variable-band sigma-delta modulator topologies are implemented in VHDL and synthesized on Xilinx® SpartanTM-3 Development Kit using fixed-point arithmetic. Circuit outputs were taken via RS232 connection provided on the FPGA board and evaluated using MATLAB routines developed by the author. These routines included the decimation process as well. The experiments undertaken by the author further validated the design methodology presented in the work. In addition, a novel tunable and reconfigurable second-order variable bandpass sigma-delta modulator has been designed and evaluated at the behavioural-level. This topology offers a flexible set of choices for designers and can operate either in single- or dual-mode enabling multi-band implementations on a single digital variable bandpass sigma-delta modulator. This work is also supported by a novel user-friendly design and evaluation tool that has been developed in MATLAB/Simulink that can speed-up the design, evaluation and comparison of analog and digital single-stage and time-interleaved variable bandpass sigma-delta modulators. This tool enables the user to specify the conversion type, topology, loop-filter type, path number and oversampling ratio.
Resumo:
This thesis details the design and applications of a terahertz (THz) frequency comb spectrometer. The spectrometer employs two offset locked Ti:Sapphire femtosecond oscillators with repetition rates of approximately 80 MHz, offset locked at 100 Hz to continuously sample a time delay of 12.5 ns at a maximum time delay resolution of 15.6 fs. These oscillators emit continuous pulse trains, allowing the generation of a THz pulse train by the master, or pump, oscillator and the sampling of this THz pulse train by the slave, or probe, oscillator via the electro-optic effect. Collecting a train of 16 consecutive THz pulses and taking the Fourier transform of this pulse train produces a decade-spanning frequency comb, from 0.25 to 2.5 THz, with a comb tooth width of 5 MHz and a comb tooth spacing of ~80 MHz. This frequency comb is suitable for Doppler-limited rotational spectroscopy of small molecules. Here, the data from 68 individual scans at slightly different pump oscillator repetition rates were combined, producing an interleaved THz frequency comb spectrum, with a maximum interval between comb teeth of 1.4 MHz, enabling THz frequency comb spectroscopy.
The accuracy of the THz frequency comb spectrometer was tested, achieving a root mean square error of 92 kHz measuring selected absorption center frequencies of water vapor at 10 mTorr, and a root mean square error of 150 kHz in measurements of a K-stack of acetonitrile. This accuracy is sufficient for fitting of measured transitions to a model Hamiltonian to generate a predicted spectrum for molecules of interest in the fields of astronomy and physical chemistry. As such, the rotational spectra of methanol and methanol-OD were acquired by the spectrometer. Absorptions from 1.3 THz to 2.0 THz were compared to JPL catalog data for methanol and the spectrometer achieved an RMS error of 402 kHz, improving to 303 kHz when excluding low signal-to-noise absorptions. This level of accuracy compares favorably with the ~100 kHz accuracy achieved by JPL frequency multiplier submillimeter spectrometers. Additionally, the relative intensity performance of the THz frequency comb spectrometer is linear across the entire decade-spanning bandwidth, making it the preferred instrument for recovering lineshapes and taking absolute intensity measurements in the THz region. The data acquired by the Terahertz Frequency Comb Spectrometer for methanol-OD is of comparable accuracy to the methanol data and may be used to refine the fit parameters for the predicted spectrum of methanol-OD.
Resumo:
This paper proposes an algorithm to estimate two parameter values vs, transcription of frq gene, and vd, maximum rate of FRQ protein degradation for an existing 3rd order Neurospora model in literature. Details of the algorithm with simulation results are shown in this paper.
Sensitivity to noise and ergodicity of an assembly line of cellular automata that classifies density
Resumo:
We investigate the sensitivity of the composite cellular automaton of H. Fuks [Phys. Rev. E 55, R2081 (1997)] to noise and assess the density classification performance of the resulting probabilistic cellular automaton (PCA) numerically. We conclude that the composite PCA performs the density classification task reliably only up to very small levels of noise. In particular, it cannot outperform the noisy Gacs-Kurdyumov-Levin automaton, an imperfect classifier, for any level of noise. While the original composite CA is nonergodic, analyses of relaxation times indicate that its noisy version is an ergodic automaton, with the relaxation times decaying algebraically over an extended range of parameters with an exponent very close (possibly equal) to the mean-field value.
Resumo:
Imaging Spectroscopy (IS) is a promising tool for studying soil properties in large spatial domains. Going from point to image spectrometry is not only a journey from micro to macro scales, but also a long stage where problems such as dealing with data having a low signal-to-noise level, contamination of the atmosphere, large data sets, the BRDF effect and more are often encountered. In this paper we provide an up-to-date overview of some of the case studies that have used IS technology for soil science applications. Besides a brief discussion on the advantages and disadvantages of IS for studying soils, the following cases are comprehensively discussed: soil degradation (salinity, erosion, and deposition), soil mapping and classification, soil genesis and formation, soil contamination, soil water content, and soil swelling. We review these case studies and suggest that the 15 data be provided to the end-users as real reflectance and not as raw data and with better signal-to-noise ratios than presently exist. This is because converting the raw data into reflectance is a complicated stage that requires experience, knowledge, and specific infrastructures not available to many users, whereas quantitative spectral models require good quality data. These limitations serve as a barrier that impedes potential end-users, inhibiting researchers from trying this technique for their needs. The paper ends with a general call to the soil science audience to extend the utilization of the IS technique, and it provides some ideas on how to propel this technology forward to enable its widespread adoption in order to achieve a breakthrough in the field of soil science and remote sensing. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
General measures of reaction to noise, which assess the respondent's perceived affectedness or dissatisfaction, appear to be more valid and internally consistent than more narrow measures, such as specific assessment of noise annoyance. However, the test-retest reliability of general and specific measures has yet to be compared. As a part of the large-scale Sydney Airport Health Study, 97 respondents participated in the same interview twice, several weeks apart. Test-retest reliabilities were found to be significant (p
Resumo:
Parenteral anticoagulation is a cornerstone in the management of venous and arterial thrombosis. Unfractionated heparin has a wide dose/response relationship, requiring frequent and troublesome laboratorial follow-up. Because of all these factors, low-molecular-weight heparin use has been increasing. Inadequate dosage has been pointed out as a potential problem because the use of subjectively estimated weight instead of real measured weight is common practice in the emergency department (ED). To evaluate the impact of inadequate weight estimation on enoxaparin dosage, we investigated the adequacy of anticoagulation of patients in a tertiary ED where subjective weight estimation is common practice. We obtained the estimated, informed, and measured weight of 28 patients in need of parenteral anticoagulation. Basal and steady-state (after the second subcutaneous shot of enoxaparin) anti-Xa activity was obtained as a measure of adequate anticoagulation. The patients were divided into 2 groups according the anticoagulation adequacy. From the 28 patients enrolled, 75% (group 1, n = 21) received at least 0.9 mg/kg per dose BID and 25% (group 2, n = 7) received less than 0.9 mg/kg per dose BID of enoxaparin. Only 4 (14.3%) of all patients had anti-Xa activity less than the inferior limit of the therapeutic range (<0.5 UI/mL), all of them from group 2. In conclusion, when weight estimation was used to determine the enoxaparin dosage, 25% of the patients were inadequately anticoagulated (anti-Xa activity <0.5 UI/mL) during the initial crucial phase of treatment. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Background The aim of this study was to validate a biomagnetic method (alternate current biosusceptometry, ACB) for monitoring gastric wall contractions in rats. Methods In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed in pentobarbital-anesthetized rats with SG and magnetic markers previously implanted under the gastric serosa or after ingestion of magnetic material. Gastric motility was quantified from the tracing amplitudes and frequency profiles obtained by Fast Fourier Transform. Key Results The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation coefficient between the ACB and SG signal amplitude was higher (P < 0.0001) in the postprandial (88.3 +/- 9.1 V) than in the fasting state (31.0 +/- 16.9 V). Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation between techniques for fasting-state recordings. When a magnetic material was ingested, there was also strong correlation in the frequency and signal amplitude and a small phase-difference between the techniques. The contraction frequencies using ACB were 0.068 +/- 0.007 Hz (postprandial) and 0.058 +/- 0.007 Hz (fasting) (P < 0.002) and those using SG were 0.066 +/- 0.006 Hz (postprandial) and 0.059 +/- 0.008 Hz (fasting) (P < 0.005). Conclusions & Inferences In summary, ACB is reliable for monitoring gastric wall contractions using both implanted and ingested magnetic materials, and may serve as an accurate and sensitive technique for gastrointestinal motility studies.
Resumo:
Abstract: Ototoxic substances have been associated to damage of the auditory system, and its effects are potentiated by noise exposure. The present study aims at analyzing auditory changes from combined exposure to noise and organic solvents, through a pilot study in the furniture industry sector. Audiological tests were performed on 44 workers, their levels of exposure to toluene, xylene and ethylbenzene were determined and the levels of noise exposure were evaluated. The results showed that workers are generally exposed to high noise levels and cabin priming filler and varnish sector workers have high levels of exposure to toluene. However, no hearing loss was registered among the workers. Workers exposed simultaneously to noise and ototoxic substances do not have a higher degree of hearing loss than those workers exposed only to noise. Thus, the results of this study did not show that the combined exposure to noise and the organic solvent is associated with hearing disorders.
Resumo:
OBJECTIVE To evaluate the audiometric profile of civilian pilots according to the noise exposure level. METHODS This observational cross-sectional study evaluated 3,130 male civilian pilots aged between 17 and 59 years. These pilots were subjected to audiometric examinations for obtaining or revalidating the functional capacity certificate in 2011. The degree of hearing loss was classified as normal, suspected noise-induced hearing loss, and no suspected hearing loss with other associated complications. Pure-tone air-conduction audiometry was performed using supra-aural headphones and acoustic stimulus of the pure-tone type, containing tone thresholds of frequencies between 250 Hz and 6,000 Hz. The independent variables were professional categories, length of service, hours of flight, and right or left ear. The dependent variable was pilots with suspected noise-induced hearing loss. The noise exposure level was considered low/medium or high, and the latter involved periods > 5,000 flight hours and > 10 years of flight service. RESULTS A total of 29.3% pilots had suspected noise-induced hearing loss, which was bilateral in 12.8% and predominant in the left ear (23.7%). The number of pilots with suspected hearing loss increased as the noise exposure level increased. CONCLUSIONS Hearing loss in civilian pilots may be associated with noise exposure during the period of service and hours of flight.
Resumo:
Breast cancer is the most common type of cancer among women all over the world. An important issue that is not commonly addressed in breast cancer imaging literature is the importance of imaging the underarm region—where up to 80% of breast cancer cells can metastasise to. The first axillary lymph nodes to receive drainage from the primary tumour in the breast are called Sentinel Node. If cancer cells are found in the Sentinel Node, there is an increased risk of metastatic breast cancer which makes this evaluation crucial to decide what follow-up exams and therapy to follow. However, non-invasive detection of cancer cells in the lymph nodes is often inconclusive, leading to the surgical removal of too many nodes which causes adverse side-effects for patients. Microwave Imaging is one of the most promising non-invasive imaging modalities for breast cancer early screening and monitoring. This novel study tests the feasibility of imaging the axilla region by means of the simulation of an Ultra-Wideband Microwave Imaging system. Simulations of such system are completed in several 2D underarm models that mimic the axilla. Initial imaging results are obtained by means of processing the simulated backscattered signals by eliminating artefacts caused by the skin and beamforming the processed signals in order to time-align all the signals recorded at each antenna. In this dissertation several image formation algorithms are implemented and compared by visual inspection of the resulting images and through a range of performance metrics, such as Signal-to-Clutter Ratio and FullWidth Half Maximum calculations. The results in this study showed that Microwave Imaging is a promising technique that might allow to identify the presence and location of metastasised cancer cells in axillary lymph nodes, enabling the non-invasive evaluation of breast cancer staging.