999 resultados para Free-vibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Industry and large Agencies needs ¿agile¿ programming resources, to reinforce their own development staff and take advantage of innovative approaches produced by ¿fresh minds¿ all over the world. At the same time they may be reluctant to engage in classical software development call for tenders and contracts. Such contracts are often ¿trusted¿ by large ICT firms, which will deliver according to their own rigid frameworks (often based on alliances with proprietary software vendors), may propose comfortable quality assurances, but will cover their (real) risks and liability with high contingency costs and will charge for any change request in case the original specifications have not fixed all possible issues. Introducing FLOSS in business implies a new contracting philosophy, based on incentives rather than penalties and liability. Based on 2011 experience with a large Space Agency, Patrice-Emmanuel Schmitz pictures the needed legal instruments for a novel approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Free Open Source Software (FOSS) seem far from the military field but in some cases, some technologies normally used for civilian purposes may have military applications. These products and technologies are called dual-use. Can we manage to combine FOSS and dual-use products? On one hand, we have to admit that this kind of association exists - dual-use software can be FOSS and many examples demonstrate this duality - but on the other hand, dual-use software available under free licenses lead us to ask many questions. For example, the dual-use export control laws aimed at stemming the proliferation of weapons of mass destruction. Dual-use export in United States (ITAR) and Europe (regulation 428/2009) implies as a consequence the prohibition or regulation of software exportation, involving the closing of source code. Therefore, the issues of exported softwares released under free licenses arises. If software are dual-use goods and serve for military purposes, they may represent a danger. By the rights granted to licenses to run, study, redistribute and distribute modified versions of the software, anyone can access the free dual-use software. So, the licenses themselves are not at the origin of the risk, it is actually linked to the facilitated access to source codes. Seen from this point of view, it goes against the dual-use regulation which allows states to control these technologies exportation. For this analysis, we will discuss about various legal questions and draft answers from either licenses or public policies in this respect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Softcatalà is a non-profit associationcreated more than 10 years ago to fightthe marginalisation of the Catalan languagein information and communicationtechnologies. It has led the localisationof many applications and thecreation of a website which allows itsusers to translate texts between Spanishand Catalan using an external closed-sourcetranslation engine. Recently,the closed-source translation back-endhas been replaced by a free/open-sourcesolution completely managed by Softcatalà: the Apertium machine translationplatform and the ScaleMT web serviceframework. Thanks to the opennessof the new solution, it is possibleto take advantage of the huge amount ofusers of the Softcatalà translation serviceto improve it, using a series ofmethods presented in this paper. In addition,a study of the translations requestedby the users has been carriedout, and it shows that the translationback-end change has not affected theusage patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

rejection can lead to loss of function. Histological reading of endomyocardial biopsy remains the "gold standard" for guiding immunosuppression, despite its methodological limitations (sampling error and interobserver variability). The measurement of the T2 relaxation time has been suggested for detection of allograft rejection, on the pathophysiological basis that the T2 relaxation time prolongs with local edema resulting from acute allograft rejection. Using breath-held cardiac magnetic resonance T2 mapping at 1.5 T, Usman et al. (CircCardiovascImaging2012) detected moderate allograft rejection (grade 2R, ISHLT 2004). With modern immunosuppression grade 2R rejection has become a rare event, but the need remains for a technique that permits the discrimination of absent (grade 0R) and mild rejection (grade 1R). We therefore investigated whether an increase of magnetic field strength to 3T and the use of real-time navigator-gated respiration compensation allow for an increase in the sensitivity of T2 relaxation time detection that is necessary to achieve this discrimination. Methods: Eighteen patients received EMB (Tan et al., ArchPatholLabMed2007) and cardiac T2 mapping on the same day. Reading of T2 maps was blinded to the histological results. For final analysis, 3 cases with known 2R rejection at the time of T2 mapping were added, yielding 21 T2 mapping sessions. A respiration-navigator-gated radial gradient-recalled-echo pulse sequence (resolution 1.17 mm2, matrix 2562, trigger time 3 heartbeats, T2 preparation duration TET2 Prep = 60/30/0 ms) was applied to obtain 3 short-axis T2 maps (van Heeswijk et al., JACCCardiovascImaging2012), which were segmented according to AHA guidelines (Cerqueira et al, Circulation2001). The highest segmental T2 values were grouped according to histological rejection grade and differences were analyzed by Student's t-test, except for the non-blinded cases with 2R rejection. The degree of discrimination was determined using the Spearman's ranked correlation test. Results: The high-quality T2 maps allowed for visual differentiation of the rejection degrees (Figure 1), and the correlation of T2 mapping with the histological grade of acute cellular rejection was significant (Spearman's r = 0.56, p = 0.007). The 0R (n = 15) and 1R (n = 3) degrees demonstrated significantly different T2 values (46.9 ± 5.0 and 54.3 ± 3.0 ms, p = 0.02, Figure 2). Cases with 2R rejection showed clear T2 elevation (T2 = 60.3 ± 16.2 ms). Conclusions: This pilot study demonstrates that non-invasive free-breathing cardiac T2 mapping at 3T discriminates between no and mild cardiac allograft rejection. Confirmation of these encouraging results in a larger cohort should consider a study able to show equivalency or superiority of T2 mapping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tavoitteena oli selvittää tilannetta Euroopan automaattiteräsmarkkinoilla ja sen perusteella arvioida Imatra Steelin mahdollisuuksia kilpailla kyseessä olevilla markkinoilla. Tärkein tavoite oli kokonaismarkkinapotentiaalin arvioiminen Saksan, Ruotsin, Englannin ja Suomen markkinoilla. Lisäksi selvitettiin käytetyt automaattiteräslajit ja mitta-alue, hintataso sekä koneistukseenliittyviä teknisiä yksityiskohtia.Tavoitteena oli myös kartoittaa asenteita ja mielipiteitä mahdollisesta lyijyn käytön kieltämisestä teräksen seosaineena tulevaisuudessa. Paremman kokonaiskuvan saamiseksi analysoitiin myös kilpailutilannetta Euroopassa. Työn teoriakehyksessä tutkittiin teollisuustuotteiden markkinatutkimuksen suorittamisen erityispiirteitä, markkinapotentiaalin määrittämiseen liittyviä käsitteitä ja kilpailija-analyysin suorittamista. Empiirinen tutkimus suoritettiin pääasiassa asiantuntijoiden haastattelujen ja kyselyjen avulla. Haastateltavina oli tukkureita ja loppukäyttäjiä. Kilpailutilanteen kartoittaminen perustuu lähinnä sekundääriseen tietoon, Internet-sivuihin ja myyntikonttoreiden aikaisemmin keräämään tietoon.Automaattiterästen kokonaispotentiaaliksi Euroopassa arvioitiin miljoona tonnia ja suurin osa kaupasta käydään tutkituilla markkina-alueilla. Suurimmat volyymit sijoittuvat pienemmille mitta-alueille, Æ 12 - 50 mm. Markkinoita hallitsee muutama suuri teräksen valmistaja. Imatra Steel kohtuullisen pienenä toimittajana ei pysty kilpailemaan volyymilla ja tuotevalikoimallaan suurten teräsjättien kanssa. Imatra Steelin mahdollinen strategiavaihtoehto olisi yrittää löytää ne kapeat segmentit ja markkinaraot, joilla sen tuotteet jatietotaito tuovat asiakkaalle suurimman mahdollisen hyödyn verrattuna kilpailijoihin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study all the symmetries of the free Schr odinger equation in the non-commu- tative plane. These symmetry transformations form an infinite-dimensional Weyl algebra that appears naturally from a two-dimensional Heisenberg algebra generated by Galilean boosts and momenta. These infinite high symmetries could be useful for constructing non-relativistic interacting higher spin theories. A finite-dimensional subalgebra is given by the Schröodinger algebra which, besides the Galilei generators, contains also the dilatation and the expansion. We consider the quantization of the symmetry generators in both the reduced and extended phase spaces, and discuss the relation between both approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study all the symmetries of the free Schrödinger equation in the non-commu- tative plane. These symmetry transformations form an infinite-dimensional Weyl algebra that appears naturally from a two-dimensional Heisenberg algebra generated by Galilean boosts and momenta. These infinite high symmetries could be useful for constructing non-relativistic interacting higher spin theories. A finite-dimensional subalgebra is given by the Schröodinger algebra which, besides the Galilei generators, contains also the dilatation and the expansion. We consider the quantization of the symmetry generators in both the reduced and extended phase spaces, and discuss the relation between both approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this master's thesis a mechanical model that is driven with variable speed synchronous machine was developed. The developed mechanical model simulates the mechanics of power transmission and its torsional vibrations. The mechanical model was developed for the need of the branched mechanics of a rolling mill and the propulsion system of a tanker. First, the scope of the thesis was to clarify the concepts connected to the mechanical model. The clarified concepts are the variable speed drive, the mechanics of power transmission and the vibrationsin the power transmission. Next, the mechanical model with straight shaft line and twelve moments of inertia that existed in the beginning was developed to be branched considering the case of parallel machines and the case of parallel rolls. Additionally, the model was expanded for the need of moreaccurate simulation to up to thirty moments of inertia. The model was also enhanced to enable three phase short circuit situation of the simulated machine. After that the mechanical model was validated by comparing the results of the developed simulation tool to results of other simulation tools. The compared results are the natural frequencies and mode shapes of torsional vibration, the response of the load torque step and the stress in the mechanical system occurred by the permutation of the magnetic field that is arisen from the three phase short circuit situation. The comparisons were accomplished well and the mechanical model was validated for the compared cases. Further development to be made is to develop the load torque to be time-dependent and to install two frequency converters and two FEM modeled machines to be simulated parallel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ratio of resting metabolic rate (RMR) to fat-free mass (FFM) is often used to compare individuals of different body sizes. Because RMR has not been well described over the full range of FFM, a literature review was conducted among groups with a wide range of FFM. It included 31 data sets comprising a total of 1111 subjects: 118 infants and preschoolers, 323 adolescents, and 670 adults; FFM ranged from 2.8 to 106 kg. The relationship of RMR to FFM was found to be nonlinear and average slopes of the regression equations of the three groups differed significantly (P less than 0.0001). For only the youngest group did the intercept approach zero. The lower slopes of RMR on FFM, at higher measures of FFM, corresponded to relatively greater proportions of less metabolically active muscle mass and to lesser proportions of more metabolically active nonmuscle organ mass. Because the contribution of FFM to RMR is not constant, an arithmetic error is introduced when the ratio of RMR to FFM is used. Hence, alternative methods should be used to compare individuals with markedly different FFM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order that the radius and thus ununiform structure of the teeth and otherelectrical and magnetic parts of the machine may be taken into consideration the calculation of an axial flux permanent magnet machine is, conventionally, doneby means of 3D FEM-methods. This calculation procedure, however, requires a lotof time and computer recourses. This study proves that also analytical methods can be applied to perform the calculation successfully. The procedure of the analytical calculation can be summarized into following steps: first the magnet is divided into slices, which makes the calculation for each section individually, and then the parts are submitted to calculation of the final results. It is obvious that using this method can save a lot of designing and calculating time. Thecalculation program is designed to model the magnetic and electrical circuits of surface mounted axial flux permanent magnet synchronous machines in such a way, that it takes into account possible magnetic saturation of the iron parts. Theresult of the calculation is the torque of the motor including the vibrations. The motor geometry and the materials and either the torque or pole angle are defined and the motor can be fed with an arbitrary shape and amplitude of three-phase currents. There are no limits for the size and number of the pole pairs nor for many other factors. The calculation steps and the number of different sections of the magnet are selectable, but the calculation time is strongly depending on this. The results are compared to the measurements of real prototypes. The permanent magnet creates part of the flux in the magnetic circuit. The form and amplitude of the flux density in the air-gap depends on the geometry and material of the magnetic circuit, on the length of the air-gap and remanence flux density of the magnet. Slotting is taken into account by using the Carter factor in the slot opening area. The calculation is simple and fast if the shape of the magnetis a square and has no skew in relation to the stator slots. With a more complicated magnet shape the calculation has to be done in several sections. It is clear that according to the increasing number of sections also the result will become more accurate. In a radial flux motor all sections of the magnets create force with a same radius. In the case of an axial flux motor, each radial section creates force with a different radius and the torque is the sum of these. The magnetic circuit of the motor, consisting of the stator iron, rotor iron, air-gap, magnet and the slot, is modelled with a reluctance net, which considers the saturation of the iron. This means, that several iterations, in which the permeability is updated, has to be done in order to get final results. The motor torque is calculated using the instantaneous linkage flux and stator currents. Flux linkage is called the part of the flux that is created by the permanent magnets and the stator currents passing through the coils in stator teeth. The angle between this flux and the phase currents define the torque created by the magnetic circuit. Due to the winding structure of the stator and in order to limit the leakage flux the slot openings of the stator are normally not made of ferromagnetic material even though, in some cases, semimagnetic slot wedges are used. In the slot opening faces the flux enters the iron almost normally (tangentially with respect to the rotor flux) creating tangential forces in the rotor. This phenomenon iscalled cogging. The flux in the slot opening area on the different sides of theopening and in the different slot openings is not equal and so these forces do not compensate each other. In the calculation it is assumed that the flux entering the left side of the opening is the component left from the geometrical centre of the slot. This torque component together with the torque component calculated using the Lorenz force make the total torque of the motor. It is easy to assume that when all the magnet edges, where the derivative component of the magnet flux density is at its highest, enter the slot openings at the same time, this will have as a result a considerable cogging torque. To reduce the cogging torquethe magnet edges can be shaped so that they are not parallel to the stator slots, which is the common way to solve the problem. In doing so, the edge may be spread along the whole slot pitch and thus also the high derivative component willbe spread to occur equally along the rotation. Besides forming the magnets theymay also be placed somewhat asymmetric on the rotor surface. The asymmetric distribution can be made in many different ways. All the magnets may have a different deflection of the symmetrical centre point or they can be for example shiftedin pairs. There are some factors that limit the deflection. The first is that the magnets cannot overlap. The magnet shape and the relative width compared to the pole define the deflection in this case. The other factor is that a shifting of the poles limits the maximum torque of the motor. If the edges of adjacent magnets are very close to each other the leakage flux from one pole to the other increases reducing thus the air-gap magnetization. The asymmetric model needs some assumptions and simplifications in order to limit the size of the model and calculation time. The reluctance net is made for symmetric distribution. If the magnets are distributed asymmetrically the flux in the different pole pairs will not be exactly the same. Therefore, the assumption that the flux flows from the edges of the model to the next pole pairs, in the calculation model from one edgeto the other, is not correct. If it were wished for that this fact should be considered in multi-pole pair machines, this would mean that all the poles, in other words the whole machine, should be modelled in reluctance net. The error resulting from this wrong assumption is, nevertheless, irrelevant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To combine weighted iterative reconstruction with self-navigated free-breathing coronary magnetic resonance angiography for retrospective reduction of respiratory motion artifacts. METHODS: One-dimensional self-navigation was improved for robust respiratory motion detection and the consistency of the acquired data was estimated on the detected motion. Based on the data consistency, the data fidelity term of iterative reconstruction was weighted to reduce the effects of respiratory motion. In vivo experiments were performed in 14 healthy volunteers and the resulting image quality of the proposed method was compared to a navigator-gated reference in terms of acquisition time, vessel length, and sharpness. RESULT: Although the sampling pattern of the proposed method contained 60% more samples with respect to the reference, the scan efficiency was improved from 39.5 ± 10.1% to 55.1 ± 9.1%. The improved self-navigation showed a high correlation to the standard navigator signal and the described weighting efficiently reduced respiratory motion artifacts. Overall, the average image quality of the proposed method was comparable to the navigator-gated reference. CONCLUSION: Self-navigated coronary magnetic resonance angiography was successfully combined with weighted iterative reconstruction to reduce the total acquisition time and efficiently suppress respiratory motion artifacts. The simplicity of the experimental setup and the promising image quality are encouraging toward future clinical evaluation. Magn Reson Med 73:1885-1895, 2015. © 2014 Wiley Periodicals, Inc.