866 resultados para Dose Adjustment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to report the sensitization of the TL peak appearing at 270 degrees C in the glow curve of natural quartz by using the combined effect of heat-treatments and irradiation with high gamma doses. For this, thirty discs with 6 x 1 mm(2) were prepared from plates parallell to a rhombolledral crystal face. The specimens were separated into four lots according to its TL read out between 160 and 320 degrees C. One lot was submitted to gamma doses of Co-60 radiation starting at 2 kGy and going up until a cumulative dose of 25 kGy. The other three lots were initially heal-treated at 500, 800 and 1000 degrees C and then irradiated with a single dose of 25kGy. The TL response of each lot was determined as a function of test-doses ranging from 0.1 to 30 mGy. As a result, it was observed that heat-treatments themselves did not produce the strong peak at 270 degrees C that was observed after the administration of high gamma doses. This peak is associated with the optical absorption band appearing at 470 rim which is due to the formation of [AlO4]degrees acting as electron-hole recombination centers. The formation of the 270 degrees C peak was preliminary analyzed in relation to aluminum- and oxygen-vacancy-related centers found in crystalline quartz. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo. in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0,068 mGy (5-9 years old)-. 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20mGy, respectively) are above the European reference levels (1.5mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a preliminary survey of doses in pediatric radiological examinations and they show that it is necessary to investigate the technical parameters to perform the radiographs. to introduce practices to control pediatric patient`s doses and to improve the personnel training to perform a pediatric examination. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to validate the Geant4 toolkit for dosimetry applications, simulations were performed to calculate conversion coefficients h(10, alpha) from air kerma free-in-air to personal dose equivalent Hp(10, a). The simulations consisted of two parts: the production of X-rays with radiation qualities of narrow and wide spectra, and the interaction of radiation with ICRU tissue-equivalent and ISO water slab phantoms. The half-value layers of the X-ray spectra obtained by simulation were compared with experimental results. Mean energy, spectral resolution, half-value layers and conversion coefficients were compared with ISO reference values. The good agreement between results from simulation and reference data shows that the Geant4 is suitable for dosimetry applications which involve photons with energies in the range of ten to a few hundreds of keV. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effects of low-dose therapeutic ionizing radiation on different aesthetic dental materials. Forty five specimens (n = 45) of three different aesthetic restorative materials were prepared and randomly divided into five groups: G1 (control group); G2, G3, G4, G5 experimental groups irradiated respectively with 0.25, 0.50, 0.75, and 1.00 Gy of gamma radiation by the (60)Co teletherapy machine. Chemical analyses were performed using a FT-IR Nicolet 520 spectrophotometer with reflectance diffuse technique. Even a minimal exposition at ionizing radiation in therapeutic doses can provide chemical changes on light-cured composite resins. The three studied restorative materials showed changes after exposure at gamma radiation, however the increase of the radiation dose did not contribute to an increase in this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider consider the problem of dichotomizing a continuous covariate when performing a regression analysis based on a generalized estimation approach. The problem involves estimation of the cutpoint for the covariate and testing the hypothesis that the binary covariate constructed from the continuous covariate has a significant impact on the outcome. Due to the multiple testing used to find the optimal cutpoint, we need to make an adjustment to the usual significance test to preserve the type-I error rates. We illustrate the techniques on one data set of patients given unrelated hematopoietic stem cell transplantation. Here the question is whether the CD34 cell dose given to patient affects the outcome of the transplant and what is the smallest cell dose which is needed for good outcomes. (C) 2010 Elsevier BM. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Likelihood ratio tests can be substantially size distorted in small- and moderate-sized samples. In this paper, we apply Skovgaard`s [Skovgaard, I.M., 2001. Likelihood asymptotics. Scandinavian journal of Statistics 28, 3-321] adjusted likelihood ratio statistic to exponential family nonlinear models. We show that the adjustment term has a simple compact form that can be easily implemented from standard statistical software. The adjusted statistic is approximately distributed as X(2) with high degree of accuracy. It is applicable in wide generality since it allows both the parameter of interest and the nuisance parameter to be vector-valued. Unlike the modified profile likelihood ratio statistic obtained from Cox and Reid [Cox, D.R., Reid, N., 1987. Parameter orthogonality and approximate conditional inference. journal of the Royal Statistical Society B49, 1-39], the adjusted statistic proposed here does not require an orthogonal parameterization. Numerical comparison of likelihood-based tests of varying dispersion favors the test we propose and a Bartlett-corrected version of the modified profile likelihood ratio test recently obtained by Cysneiros and Ferrari [Cysneiros, A.H.M.A., Ferrari, S.L.P., 2006. An improved likelihood ratio test for varying dispersion in exponential family nonlinear models. Statistics and Probability Letters 76 (3), 255-265]. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In Sweden, midwives play prominent supportive role in antenatal care by counselling and promoting healthy lifestyles. This study aimed to explore how Swedish midwives experience the counselling of pregnant women on physical activity, specifically focusing on facilitators and barriers during pregnancy. Also, addressing whether the midwives perceive that their own lifestyle and body shape may influence the content of the counselling they provide. Methods: Eight focus group discussions (FGD) were conducted with 41 midwives working in antenatal care clinics in different parts of Sweden between September 2013 and January 2014. Purposive sampling was applied to ensure a variation in age, work experience, and geographical location. The FGD were digitally recorded, transcribed verbatim, and analyzed using manifest and latent content analysis. Results: The main theme- "An on-going individual adjustment" was built on three categories: "Counselling as a challenge"; "Counselling as walking the thin ice" and "Counselling as an opportunity" reflecting the midwives on-going need to adjust their counselling depending on each woman's specific situation. Furthermore, counselling pregnant women on physical activity was experienced as complex and ambiguous, presenting challenges as well as opportunities. When midwives challenged barriers to physical activity, they risked being rejected by the pregnant women. Despite risking rejection, the midwives tried to promote increased physical activity based on their assessment of individual needs of the pregnant woman. Some participants felt that their own lifestyle and body shape might negatively influence the counselling; however, the majority of participants did not agree with this perspective. Conclusions: Counselling on physical activity during pregnancy may be a challenging task for midwives, characterized by on-going adjustments based on a pregnant woman's individual needs. Midwives strive to find individual solutions to encourage physical activity. However, to improve their counselling, midwives may benefit from further training, also organizational and financial barriers need to be addressed. Such efforts might result in improved opportunities to further support pregnant women's motivation for performance of physical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cintilografia com radioisótopos em repouso tem despertado muito interesse nos últimos anos para pesquisa da viabilidade miocárdica na disfunção isquêmica avançada do VE, porque esta pode ser reversível e porque há melhora prognóstica neste contexto. O objetivo desse trabalho é buscar identificar a acurácia da cintilografia tomográfica Tc-99m-Sestamibi, sob a infusão de dobutamina em baixa dose. Foram protocolados trinta pacientes que sofreram um infarto do miocárdio com padrão “Q”, com dissinergia ao ecocardiograma, e submetidos a estudos perfusionais em dias diferentes, com Tc-99m-Sestamibi − dobutamina e Tl-201 em repouso-redistribuição 4 horas, usado como padrão ouro. Não ocorreram complicações com nenhum paciente submetido ao protocolo do estudo. Os resultados revelaram: sensibilidade = 85%, especificidade = 87%, valor preditivo positivo = 96%, valor preditivo negativo = 65 % e acurácia de = 85,2%. A razão de probabilidade positiva foi de 6,68 e a razão de probabilidade negativa de 0,17. Confrontando-se nossos dados com uma metanálise de resultados para o Tc-99m-Sestamibi em repouso, a sensibilidade no presente estudo foi 85% vs. 81% e a especificidade de 87% vs. 60%. Em relação aos dados da literatura para Tl-201: 85% vs. 90% e 87% vs. 54%, sensibilidade e especificidade, respectivamente. Em conclusão, o Tc-99m-Sestamibi sob a infusão de dobutamina parece ser um método promissor para detectar viabilidade superior a esta modalidade de cintilografia em repouso, com valores preditivos comparáveis à literatura disponível para esse mesmo método: 85,2% vs. 87%, 96% vs. 90% e 65% vs. 83%, para acurácia, valor preditivo positivo e valor preditivo negativo, respectivamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os aminoglicosídeos permanecem sendo um dos principais antibióticos no tratamento de infecções causadas por bactérias gram-negativas, apesar do surgimento de novos antibióticos. Na Unidade de Endoscopia Digestiva do Hospital de Clínicas de Porto Alegre os aminoglicosídeos, combinados com antibióticos ß-lactâmicos, têm sido utilizados no tratamento de infecções das vias biliares e como antibiótico profilático em procedimento como a colangiopancreatografia endoscópica retrógrada. O objetivo do presente estudo foi comparar a eficácia terapêutica da dose única total diária com dose fracionada diária de gentamicina no tratamento da infecção das vias biliares, baseando-se na concentração biliar de gentamicina obtida nesses dois regimes terapêuticos e sua relação com a concentração inibitória mínima das principais bactérias isoladas na bile de pacientes com infecção do trato biliar. Os pacientes selecionados foram randomizados para tratamento com gentamicina na dose de 4mg/kg de peso por meio intravenoso sendo divididos em 2 grupos: grupo 1 recebeu dose única diária dividida em 3 horários (8 / 8 horas) e o grupo 2 recebeu o fármaco como dose única total diária. Os resultados do estudo evidenciaram que os níveis biliares de gentamicina nos pacientes tratados com dose única diária de gentamicina (grupo 2) ultrapassaram de 3 a 6 vezes as concentrações inibitórias mínimas das bactérias gram-negativas isoladas, enquanto que os níveis de gentamicina à nível biliar nos pacientes tratados com dose fracionada de gentamicina (grupo 1) conseguiram igualar ou ultrapassar no máximo e 3 vezes, dependendo da bactéria gram-negativa testada, as concentrações inibitórias. Além disto, os níveis biliares de gentamicina dos pacientes tratados com dose única diária permaneceram por intervalo superior a 14 horas acima das concentrações inibitórias mínimas destas bactérias, reforçando ainda mais o efeito pós-antibiótico obtido no intervalo de tempo onde não são detectados mais níveis de gentamicina na bile. Baseado nos efeitos bactericida dependente da concentração e efeito pós-antibiótico dos aminoglicosídeos,os resultados deste estudo sugerem que a dosagem única diária de gentamicina apresenta maior eficácia terapêutica que a dosagem fracionada diária no tratamento da infecção das vias biliares.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos: Determinar a dose eritematosa mínima (DEM) medida por exposição controlada à radiação ultravioleta-B (RUV-B), como limiar para dano solar agudo nos diversos fototipos, e medir a cor da pele constitucional pelo sistema colorimétrico CIELAB. Pacientes e Métodos: Um total de 194 voluntários, sadios, com idades acima de 18 anos, distribuídos em um mínimo de 30 participantes por fototipo. Todos foram classificados por fototipos segundo os critérios de Fitzpatrick. As regiões infra-axilar torácica e nádega foram irradiadas em 4 áreas de 1 cm2, assim como foi registrada a cor da pele desses locais pelo sistema CIELAB. Delineamento: Estudo transversal. Resultados: A média de idade dos participantes foi de 38 anos, sendo 68% do sexo feminino. A avaliação da associação entre as medidas das DEMs e dos valores colorimétricos da coordenada L*, mostrou uma correlação de Pearson negativa com r = -0,91 para um valor p<0,05. Para os valores das DEMs e os escores da classificação dos voluntários por fototipos, obteve-se correlação de Spearman (rs) de +0,95 para p<0,05 e, correlacionando os valores colorimétricos com os escores dos fototipos, encontrou-se em tórax um rs de -0,93 e em nádega -0,92 para um p < 0,05. Conclusões – Concluiu-se que: 1)- a mensuração dos valores colorimétricos da coordenada L* nas regiões infra-axilar torácica e nádega mostraram uma forte correlação com os valores das DEMs, sendo de menor poder invasivo e de maior praticidade para mensuração de sensibilidade à radiação ultravioleta; 2)- apesar de os escores de Fitzpatrick terem alta correlação com os valores das DEMs, mostraram superposição de valores nos fototipos adjacentes; 3)- o grau de associação das classes dos fototipos com a cor da pele permite dizer que a categoria numérica do fototipo aumenta à medida que a pele fica mais escura.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho objetivou avaliar o efeito do número de espermatozóides na dose inseminante sobre a taxa de prenhez (TPr) e no número de embriões de fêmeas suínas inseminadas pela técnica intra-uterina (IAU), em uma única inseminação (IA), efetuada no intervalo de até 24 horas antes da ovulação, considerando o refluxo de sêmen pós-inseminação. Foram utilizadas 211 fêmeas pluríparas híbridas (Landrace x Large White), com ordem de parto variando de dois a nove e intervalo desmame-estro de dois a seis dias. O diagnóstico de estro foi realizado duas vezes ao dia. Foram utilizadas doses com volume total de 20 ml contendo 0,25 x 109 (tratamento 1), 0,5 x 109 (tratamento 2) ou 1,0 x 109 (tratamento 3) espermatozóides diluídos em Beltsville Thawing Solution (BTS) produzidas em “split sample”. Quatro machos híbridos (Landrace x Large White x Pietrain) foram utilizados como doadores de sêmen. Foi acompanhada a motilidade (MOT) de uma dose de 100 ml contendo 2,5 x 109 espermatozóides proveniente de cada coleta de sêmen com a finalidade de avaliar a viabilidade espermática durante as 240 horas de armazenamento a 17°C. A coleta do refluxo vulvar, até 60 minutos após a IAU foi realizada com bolsas de colostomia descartáveis fixadas na região peri-vulvar. A determinação do número de espermatozóides contidos no refluxo foi realizada em câmara hemocitométrica. O diagnóstico de gestação foi realizado aos 20-23 dias com auxílio da ultra-sonografia transcutânea em tempo real. As fêmeas prenhes foram abatidas 34-41 dias após a IAU, onde foram coletados o útero e os ovários para contagem dos corpos lúteos e embriões. A passagem do cateter foi possível em todas as fêmeas. Não houve refluxo no momento da realização da IAU. Não houve diferença (P>0,05) no percentual de volume (pvol) e de espermatozóides (psptz) refluídos até 60 minutos após a IAU entre os três tratamentos. O baixo (inferior a 15%) ou alto (superior a 15%) psptz refluídos não influenciou a TPr, mas houve correlação negativa (P=0,0003; R=-0,34) do psptz refluídos com o número de embriões totais (NET). Não houve refluxo em apenas oito fêmeas e a amplitude do pvol variou de 0-136%. No presente trabalho, a MOT das doses inseminantes foi semelhante entre os quatro machos (P>0,05). A TPr não diferiu entre os tratamentos (P=0,36) porém foram verificadas diferenças (P<0,05) entre os machos dentro de cada tratamento. A redução na taxa de prenhez foi mais acentuada para o macho D, quando foram utilizadas doses com menor número de espermatozóides. Não houve efeito do macho ou da interação macho com tratamento sobre o número de embriões (P>0,05). O NET e viáveis diferiu entre o T1 e T2 (P<0,05). Utilizando-se apenas uma única inseminação intra-uterina no intervalo de até 24 horas antes da ovulação com 0,5 x 109 espermatozóides, é possível alcançar índices superiores a 85% de prenhez e 14 embriões, aos 34-41 dias de gestação.