992 resultados para Distributed Dislocation Dipole Technique
Resumo:
Selostus: Mahdollisuus lyhytaikaisen virtsankeruun käyttöön lypsylehmien virtsan pseudouridiinin erityksen määrittämisessä
Resumo:
We examined sequence variation in the mitochondrial cytochrome b gene (1140 bp, n = 73) and control region (842-851 bp, n = 74) in the Eurasian harvest mouse (Micromys minutus (Pallas, 1771)), with samples drawn from across its range, from Western Europe to Japan. Phylogeographic analyses revealed region-specific haplotype groupings combined with overall low levels of inter-regional genetic divergence. Despite the enormous intervening distance, European and East Asian samples showed a net nucleotide divergence of only 0.36%. Based on an evolutionary rate for the cytochrome b gene of 2.4%(.)(site(.)lineage(.)million years)(-1), the initial divergence time of these populations is estimated at around 80 000 years before present. Our findings are consistent with available fossil evidence that has recorded repeated cycles of extinction and recolonization of Europe by M. minutus through the Quaternary. The molecular data further suggest that recolonization occurred from refugia in the Central to East Asian region. Japanese haplotypes of M. minutus, with the exception of those from Tsushima Is., show limited nucleotide diversity (0.15%) compared with those found on the adjacent Korean Peninsula. This finding suggests recent colonization of the Japanese Archipelago, probably around the last glacial period, followed by rapid population growth.
Resumo:
Nonlocal approximations for the electronic exchange and correlation effects are used to compute, within density-functional theory, the polarizability and surface-plasma frequencies of small jelliumlike alkali-metal clusters. The results are compared with those obtained using the local-density approximation and with available experimental data, showing the relevance of these effects in obtaining an accurate description of the surface response of metallic clusters.
Resumo:
We have carried out a systematic analysis of the transverse dipole spin response of a large-size quantum dot within time-dependent current density functional theory. Results for magnetic fields corresponding to integer filling factors are reported, as well as a comparison with the longitudinal dipole spin response. As in the two-dimensional electron gas, the spin response at high-spin magnetization is dominated by a low-energy transverse mode.
Resumo:
Background: Arthrodesis of the knee by intramedullary fixation hasbeen reported to have a higher rate of success than external fixationor compression plating. Antegrade nailing however can lead to complicationsdue to the different diameters of the medullary canals, fracturesduring insertion, poor rotational stability, breakage of the IM-nailand insufficient compression at the fusion site.Method: This retrospective study reports all knee fusions performedby the same orthopaedic surgeon with the Wichita (Stryker) fusion nail(WFN) from 2004 to 2010. The Wichita nail is a short nail with a deviceat the knee which allows for coupling of differently sized and interlockedfemoral and tibial components and at the same time for compression.Results: We report of 18 patients with a mean follow up of 28 months(range 3-71 months). Infected TKA was the most common indicationfor arthrodesis in 9 cases. The remaining reasons included asepticfailed TKA in 3 cases, 2 patients after fracture, 1 patient with neurologicalinstability after knee dislocation, 1 patient after tumoral resectionand 1 non union after failed arthrodesis with long antegrade nail.Finally 1 patient with bilateral congenital knee dislocation operated onboth sides. As expected, patients receiving the WFN had undergonea large number of previous knee surgeries with a mean of 3.8 (range0-8) procedures per patient. The complication rate was 27% (5 of 18).Two patients had persistent pain requiring revision surgery to increasestability with plating. One case of periprosthetic fracture needed openreduction and internal fixation. 2 patients with superficial hematomawere treated one with open drainage and the other with physiotherapy.Infection was erradicated in all septic cases, we found no new infectionand the fusion rate was 100%.Conclusion: The results in these often difficult cases are satisfyingand we think that this technique is a valid alternative to the otherknown techniques of knee fusion in patients with a poor bone stockand fragile soft tissues.
Resumo:
INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.
Resumo:
Between January 1996 and July 2003, 93 consecutive patients operated on with a diagnosis of olecranon fractures were identified from our trauma unit files. Fourteen transolecranon fracture-dislocations were found after a retrospective X-radiographic evaluation. Eight patients were women and six were men, with a mean age of 54 years. There were 4 noncomminuted olecranon fractures, treated with K-wires and single tension-band wiring. The remaining 10 fractures were complex fractures, treated in 3 cases with multiple K-wires and single tension-band wiring, in 2 by use of one-third tubular plates, in 1 with a 3.5-mm dynamic compression plate, and in the remaining 4 with 3.5-mm reconstruction plates. Ligament repair was not performed in any case. Three patients needed reoperation because of early failure of primary fixation. Patients were reviewed at a mean follow-up of 3.6 years. Two reported difficulties in daily activities, none with any symptoms of elbow instability. According to the Broberg and Morrey score, 4 patients had excellent results, 6 had good results, 2 had fair results, and 2 had poor results. Four patients showed signs of degenerative arthritis on the radiographs obtained at follow-up. We conclude that transolecranon fracture-dislocation is an underreported and misdiagnosed injury. Various fixation techniques can restore the anatomic relationships and contour of the trochlear notch; the imperative goal is to obtain a good stable primary fixation and allow early active mobilization.
Resumo:
Objectifs: Evaluer la faisabilité, les résultats préliminaires à court et long terme du vissage percutané de vissage trans -isthmique sous anesthésie locale et contrôle scannerdes lyses isthmiques de bas grades.Matériels et méthodes: Etude prospective monocentrique réalisée sur 10 patients ayant une lyse isthmique grade 1 et 2 résistant au traitement médical conventionnel. Une évaluationclinique était réalisée à un mois, 3 mois, 6 mois et un an post-opératoire par un évaluateur indépendant. L'indication est posée en concertation avec le service dechirurgie orthopédique.Résultats: Les lyses isthmiques étaient situées en L5-S1 avec 6 grades 1 et 4 grades 2. L'échelle analogique de la douleur (VAS) variait de 6 a 9 avec une moyenne de 7,8.L'indication opératoire chirurgicale était posée pour tous les patients par arthrodèse postérieure lombo -sacree. Pour chaque patient 2 vis étaient positionnées soitun total de 20 vis. Un suivi clinique était réalisé de 28 a 36 mois. L'EVA et ODI diminuaient de 7,8 +/- 1,7 à 1,9 +/- 1,2 et de 62,3 +/- 17,2 à 15,1 +/- 6,0respectivement. L'ensemble des résultats était stable dans le temps en particulier à long terme.Conclusion: La fixation précise de la lyse isthmique améliore la symptomatologie et probablement évite un glissement vertébral plus important , un suivi à plus long terme surune serie de patients plus importante devrait confirmer cette hypothèse.
Resumo:
The scaling up of the Hot Wire Chemical Vapor Deposition (HW-CVD) technique to large deposition area can be done using a catalytic net of equal spaced parallel filaments. The large area deposition limit is defined as the limit whenever a further increment of the catalytic net area does not affect the properties of the deposited film. This is the case when a dense catalytic net is spread on a surface considerably larger than that of the film substrate. To study this limit, a system able to hold a net of twelve wires covering a surface of about 20 cm x 20 cm was used to deposit amorphous (a-Si:H) and microcrystalline (μc-Si:H) silicon over a substrate of 10 cm x 10 cm placed at a filament-substrate distance ranging from 1 to 2 cm. The uniformity of the film thickness d and optical constants, n(x, λ) and α(x,¯hω), was studied via transmission measurements. The thin film uniformity as a function of the filament-substrate distance was studied. The experimental thickness profile was compared with the theoretical result obtained solving the diffusion equations. The optimization of the filament-substrate distance allowed obtaining films with inhomogeneities lower than ±2.5% and deposition rates higher than 1 nm/s and 4.5 nm/s for (μc-Si:H) and (a-Si:H), respectively.
Resumo:
Two-sided flux decoration experiments indicate that threading dislocation lines (TDLs), which cross the entire film, are sometimes trapped in metastable states. We calculate the elastic energy associated with the meanderings of a TDL. The TDL behaves as an anisotropic and dispersive string with thermal fluctuations largely along its Burgers vector. These fluctuations also modify the structure factor of the vortex solid. Both effects can, in principle, be used to estimate the elastic moduli of the material.