987 resultados para Diagnostic Process
Resumo:
This is the report of a case of fetal tachyarrhythmia with 1:1 atrioventricular conduction detected by pre-natal echocardiography in a fetus at 25-weeks gestation. Adenosine infusion via cordocentesis was performed as a diagnostic test to differentiate between atrioventricular nodal reentrant supraventricular tachyarrhythmia and atrial flutter. After infusion, transient 2:1 atrioventricular dissociation was obtained and the diagnosis of atrial flutter was made. Transplacental therapy with digoxin and amiodarone was then successfully used.
Resumo:
This work focused on how different types of oil phase, MCT (medium chain triglycerides) and LCT (long chain triglycerides), exert influence on the gelation process of beeswax and thus properties of the organogel produced thereof. Organogels were produced at different temperatures and qualitative phase diagrams were constructed to identify and classify the type of structure formed at various compositions. The microstructure of gelator crystals was studied by polarized light microscopy. Melting and crystallization were characterized by differential scanning calorimetry and rheology (flow and small amplitude oscillatory measurements) to understand organogels' behaviour under different mechanical and thermal conditions. FTIR analysis was employed for a further understanding of oil-gelator chemical interactions. Results showed that the increase of beeswax concentration led to higher values of storage and loss moduli (G, G) and complex modulus (G*) of organogels, which is associated to the strong network formed between the crystalline gelator structure and the oil phase. Crystallization occurred in two steps (well evidenced for higher concentrations of gelator) during temperature decreasing. Thermal analysis showed the occurrence of hysteresis between melting and crystallization. Small angle X-ray scattering (SAXS) analysis allowed a better understanding in terms of how crystal conformations were disposed for each type of organogel. The structuring process supported by medium or long-chain triglycerides oils was an important exploit to apprehend the impact of different carbon chain-size on the gelation process and on gels' properties.
Resumo:
OBJECTIVE: To assess, in a prospective way, the experience with video-assisted pericardioscopy obtained in patients with pericardial effusion of unclear etiology in the preoperative period. METHODS: From January 1998 to June 2000, 20 patients were operated upon with the aid of video-assisted pericardioscopy. On echocardiography, 17 of these patients had significant pericardial effusion, and 3 had moderate pericardial effusion. Video-assisted pericardioscopy was performed through a small incision of the Marfan type. RESULTS: The diagnosis of pericardial effusion was established as follows: idiopathic in 9 (45%) patients, neoplastic in 4 (20%), resulting from hypothyroidism in 3 (15%), tuberculous in 2 (10%), due to cholesterol in 1 (5%), and chylopericardial in 1 (5%). The biopsy was positive in 30% of the patients, and the etiology could not be defined in 45% of the patients. CONCLUSION: Video-assisted pericardioscopy proved to be a method with low morbidity and a high index of diagnostic positivity. A high percentage of pericardial effusions are caused by viral infections, which are not diagnosed through current methods, being, therefore, classified as idiopathic.
Resumo:
OBJECTIVE - To assess the diagnostic value, the characteristics, and feasibility of tilt-table testing in children and adolescents. METHODS - From August 1991 to June 1997, we retrospectively assessed 94 patients under the age of 18 years who had a history of recurring syncope and presyncope of unknown origin and who were referred for tilt-table testing. These patients were divided into 2 groups: group I (children) - 36 patients with ages ranging from 3 to 12 (mean of 9.19±2.31) years; group II (adolescents) - 58 patients with ages ranging from 13 to 18 (mean of 16.05±1.40) years. We compared the positivity rate, the type of hemodynamic response, and the time period required for the test to become positive in the 2 groups. RESULTS - The positivity rates were 41.6 % and 50% for groups I and II, respectively. The pattern of positive hemodynamic response that predominated in both groups was the mixed response. The mean time period required for the test to become positive was shorter in group I (11.0±7.23 min) than in group II (18.44±7.83 min). No patient experienced technical difficulty or complications. CONCLUSION - No difference was observed in regard to feasibility, positivity rate, and pattern of positive response for the tilt-table test in children and adolescents. Pediatric patients had earlier positive responses.
Resumo:
OBJECTIVE: The initial site of myocardial infarction (MI) may influence the prevalence of ventricular late potentials (VLP), high-frequency signals, due to the time course of ventricular activation. The prevalence of VLP in a period of more than 2 years after acute MI was assessed focusing on the initially injured wall . METHODS: The prevalence of VLP in a late phase after MI (median of 924 days) in anterior/antero-septal and inferior/infero-dorsal wall lesion was analyzed using signal-averaged electrocardiogram in time domain. The diagnostic performance of the filters employed for analysis on was tested at high-pass cut-off frequencies of 25 Hz, 40 Hz and 80 Hz. RESULTS: The duration of the ventricular activation and its terminal portion were larger in inferior than anterior infarction, at high-pass cut-off frequencies of 40 Hz and 80 Hz. In patients with ventricular tachycardia, these differences were more remarked. The prevalence of ventricular late potentials was three times greater in inferior than anterior infarction. CONCLUSION: Late after myocardial infarction, the prevalence and the duration of ventricular late potentials are greater in lesions of inferior/infero-dorsal than anterior/antero-septal wall confirming their temporal process, reflecting their high-frequency content.
Resumo:
OBJECTIVE: To access the incidence of diagnostic errors in the initial evaluation of children with cardiac murmurs. METHODS: We evaluated our 7-years of experience in a public pediatric cardiology outpatient clinic. Of 3692 patients who were sent to the hospital, 2603 presented with a heart murmur and were investigated. Patients for whom a disagreement existed between the initial and final diagnoses were divided into the following 2 groups: G1 (n=17) with an initial diagnosis of an innocent murmur and a final diagnosis of cardiopathy, and G2 (n=161) with an initial diagnosis of cardiopathy and a final diagnosis of a normal heart. RESULTS: In G1, the great majority of patients had cardiac defects with mild hemodynamic repercussions, such as small ventricular septal defect and mild pulmonary stenosis. In G2, the great majority of structural defects were interventricular communication, atrial septal defect and pulmonary valve stenosis. CONCLUSION: A global analysis demonstrated that diagnostic error in the initial evaluation of children with cardiac murmurs is real, reaching approximately 6% of cases. The majority of these misdiagnoses were in patients with an initial diagnosis of cardiopathy, which was not confirmed through later complementary examinations. Clinical cardiovascular examination is an excellent resource in the evaluation of children suspected of having cardiopathy. Immediate outpatient discharge of children with an initial diagnosis of an innocent heart murmur seems to be a suitable approach.
Resumo:
As digital imaging processing techniques become increasingly used in a broad range of consumer applications, the critical need to evaluate algorithm performance has become recognised by developers as an area of vital importance. With digital image processing algorithms now playing a greater role in security and protection applications, it is of crucial importance that we are able to empirically study their performance. Apart from the field of biometrics little emphasis has been put on algorithm performance evaluation until now and where evaluation has taken place, it has been carried out in a somewhat cumbersome and unsystematic fashion, without any standardised approach. This paper presents a comprehensive testing methodology and framework aimed towards automating the evaluation of image processing algorithms. Ultimately, the test framework aims to shorten the algorithm development life cycle by helping to identify algorithm performance problems quickly and more efficiently.
Resumo:
Surgeons may use a number of cutting instruments such as osteotomes and chisels to cut bone during an operative procedure. The initial loading of cortical bone during the cutting process results in the formation of microcracks in the vicinity of the cutting zone with main crack propagation to failure occuring with continued loading. When a material cracks, energy is emitted in the form of Acoustic Emission (AE) signals that spread in all directions, therefore, AE transducers can be used to monitor the occurrence and development of microcracking and crack propagation in cortical bone. In this research, number of AE signals (hits) and related parameters including amplitude, duration and absolute energy (abs-energy) were recorded during the indentation cutting process by a wedge blade on cortical bone specimens. The cutting force was also measured to correlate between load-displacement curves and the output from the AE sensor. The results from experiments show AE signals increase substantially during the loading just prior to fracture between 90% and 100% of maximum fracture load. Furthermore, an amplitude threshold value of 64dB (with approximate abs-energy of 1500 aJ) was established to saparate AE signals associated with microcracking (41 – 64dB) from fracture related signals (65 – 98dB). The results also demonstrated that the complete fracture event which had the highest duration value can be distinguished from other growing macrocracks which did not lead to catastrophic fracture. It was observed that the main crack initiation may be detected by capturing a high amplitude signal at a mean load value of 87% of maximum load and unsteady crack propagation may occur just prior to final fracture event at a mean load value of 96% of maximum load. The author concludes that the AE method is useful in understanding the crack initiation and fracture during the indentation cutting process.
Resumo:
The impending introduction of lead-free solder in the manufacture of electrical and electronic products has presented the electronics industry with many challenges. European manufacturers must transfer from a tin-lead process to a lead-free process by July 2006 as a result of the publication of two directives from the European Parliament. Tin-lead solders have been used for mechanical and electrical connections on printed circuit boards for over fifty years and considerable process knowledge has been accumulated. Extensive literature reviews were conducted on the topic and as a result it was found there are many implications to be considered with the introduction of lead-free solder. One particular question that requires answering is; can lead-free solder be used in existing manufacturing processes? The purpose of this research is to conduct a comparative study of a tin-lead solder and a lead-free solder in two key surface mount technology (SMT) processes. The two SMT processes in question were the stencil printing process and the reflow soldering process. Unreplicated fractional factorial experimental designs were used to carry out the studies. The quality of paste deposition in terms of height and volume were the characteristics of interest in the stencil printing process. The quality of solder joints produced in the reflow soldering experiment was assessed using x-ray and cross sectional analysis. This provided qualitative data that was then uniquely scored and weighted using a method developed during the research. Nested experimental design techniques were then used to analyse the resulting quantitative data. Predictive models were developed that allowed for the optimisation of both processes. Results from both experiments show that solder joints of comparable quality to those produced using tin-lead solder can be produced using lead-free solder in current SMT processes.
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012
Resumo:
Limestone, calcination, normal shaft kiln, process simulation, temperature profiles