925 resultados para Compressor valve
Resumo:
Recent studies on small-scale power generation with the organic Rankine cycle suggest superior performance of positive displacement type of expanders compared to turbines. Scroll expanders in particular achieve high isentropic efficiencies due to lower leakage and frictional losses. Performance of scroll machines may be enhanced by the use of non-circular involute curves in place of the circular involutes resulting non-uniform wall thickness. In this paper, a detailed moment analysis is performed for such an expander having volumetric expansion ratio of 5 using thermodynamic models proposed earlier by one of the present authors. The working fluid considered in the power cycle is R-245fa with scroll inlet temperature of 125 degrees C for a gross power output of similar to 3.5 kW. The model developed in this paper is verified with an air scroll compressor available in the literature and then applied to an expander Prediction of small variation of moment with scroll motion recommends use of scroll expander without a flywheel over other positive displacement type of expanders, e.g. reciprocating, where a flywheel is an essential component.
Resumo:
A previously developed Stochastic Reactor Model (SRM) is used to simulate combustion in a four cylinder in-line four-stroke naturally aspirated direct injection Spark Ignition (SI) engine modified to run in Homogeneous Charge Compression Ignition (HCCI) mode with a Negative Valve Overlap (NVO). A portion of the fuel is injected during NVO to increase the cylinder temperature and enable HCCI combustion at a compression ratio of 12:1. The model is coupled with GT-Power, a one-dimensional engine simulation tool used for the open valve portion of the engine cycle. The SRM is used to model in-cylinder mixing, heat transfer and chemistry during the NVO and main combustion. Direct injection is simulated during NVO in order to predict heat release and internal Exhaust Gas Recycle (EGR) composition and mass. The NOx emissions and simulated pressure profiles match experimental data well, including the cyclic fluctuations. The model predicts combustion characteristics at different fuel split ratios and injection timings. The effect of fuel reforming on ignition timing is investigated along with the causes of cycle to cycle variations and unstable operation. A detailed flux analysis during NVO unearths interesting results regarding the effect of NOx on ignition timing compared with its effect during the main combustion. © 2009 SAE International.
Resumo:
In HCCI engines, the Air/Fuel Ratio (AFR) and Residual Gas Fraction (RGF) are difficult to control during the SI-HCCI-SI transition, and this may result in incomplete combustion and/or high pressure raise rates. As a result, there may be undesirably high engine load fluctuations. The objectives of this work are to further understand this process and develop control methods to minimize these load fluctuations. This paper presents data on instantaneous AFR and RGF measurements, both taken by novel experimental techniques. The data provides an insight into the cyclic AFR and RGF fluctuations during the switch. These results suggest that the relatively slow change in the intake Manifold Air Pressure (MAP) and actuation time of the Variable Valve Timing (VVT) are the main causes of undesired AFR and RGF fluctuations, and hence an unacceptable Net IMEP (NIMEP) fluctuation. We also found large cylinder-to-cylinder AFR variations during the transition. Therefore, besides throttle opening control and VVT shifting, cyclic and individual cylinder fuel injection control is necessary to achieve a smooth transition. The control method was developed and implemented in a test engine, and the result was a considerably reduced NIMEP fluctuation during the mode switch. The instantaneous AFR and RGF measurements could furthermore be adopted to develop more sophisticated control methods for SI-HCCI-SI transitions. © 2010 SAE International.
Resumo:
In this work, the formation of soot in a Direct Injection Spark Ignition (DISI) engine is simulated using the Stochastic Reactor Model (SRM) engine code. Volume change, convective heat transfer, turbulent mixing, direct injection and flame propagation are accounted for. In order to simulate flame propagation, the cylinder is divided into an unburned, entrained and burned zone, with the rate of entrainment being governed by empirical equations but combustion modelled with chemical kinetics. The model contains a detailed chemical mechanism as well as a highly detailed soot formation model, however computation times are relatively short. The soot model provides information on the morphology and chemical composition of soot aggregates along with bulk quantities, including soot mass, number density, volume fraction and surface area. The model is first calibrated by simulating experimental data from a Gasoline Direct Injection (GDI) Spark Ignition (SI) engine. The model is then used to simulate experimental data from the literature, where the numbers, sizes and derived mass particulate emissions from a 1.83 L, 4-cylinder, 4 valve production DISI engine were examined. Experimental results from different injection and spark timings are compared with the model and the qualitative trends in aggregate size distribution and emissions match the exhaust gas measurements well. © 2010 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
Resumo:
Techniques are described for preparing acetate peels of sectioned valves of ocean quahogs, Arctica islandica, for age determinations. The respective sequence of preparation begins by sectioning left valves oriented to include a single hinge tooth, bleaching to remove the heavy periostracum, embedding the valves in an epoxy resin, grinding and polishing the embedments to a high luster, etching the exposed cut valve surfaces, and applying sheet acetate with acetone. Annuli are clearly defined relative to growth increments in the peel preparations for all sizes and ages of ocean quahogs. (PDF file contains12 pages.)
Resumo:
The fabrication and operational techniques of Malian and Ndurutu traps mostly used by the fishermen in River Rima in north western Nigeria were evaluated through structured questionnaire and measurement of samples of the Data collected were analyzed using descriptive statistics. There was no standard in the dimensions of either of the traps. The traps were made of locally sourced materials, except the synthetic net of the Malian trap. About 81 and 80% of the respondents fabricated their Malian and Ndurutu traps, respectively. The major problems encountered in the structure and operation of the Malian trap included projection above water, stealing of catches and trap, and trapping of small sized fishes as indicated by 61.9, 47.6 and 28.6% of the respondents, respectively. In the case of the Ndurutu trap, 72.0, 48.0, 12.0 and 8.0% of the respondents respectively indicated poor durability, single entrance valve, destruction by cattle and instability in water, as the major problems encountered. As improvement measures for the Malian trap, the respondents suggested increase in number and size of valve (81.0%), horizontal positioning (57.1%) and square shape (47.6%) while 52.0% each suggested increase in number of entrance valve and netting of Ndurutu trap. The fishermen demonstrated ingenuity in the fabrication and operation of the traps, but they failed to initiate the required improvement. It is important to critically examine the designs, materials, costs and limitations of the traps and the suggestions of the fishermen, as basis for improvement on the technology of the traps
Resumo:
Based on the findings and diagnostic survey, a new fishing trap, christened Lege trap was designed and fabricated, and the performance evaluated. The 8-valve Lege trap was assessed concurrently with Malian and Ndurutu traps by the fishermen in the study area. The experiment was conducted in a randomized complete block design with one factor each replicated three times. Data collected on fish diversity number, biomass and size were subjected to descriptive statistics and analysis of variance. The results showed that 22 fish species belonging to thirteen families were caught. The prototype (Lege) trap recorded higher species diversity index (0.90) than the Malian (0.50) and Ndurutu (0.50) traps. The Lege trap also accounted for the largest number (55%) and biomass (63%) of fish caught which was significantly (P<0.05) higher than those of the Malian and Nduutu traps were. The mean length (15.03~c5.70cm), weight (60.43~c48.61g) and girth (4.77~c1.65cm) of fishes caught in the Lege trap were also significantly (P0.05) higher than those caught in the other two traps. These results demonstrated better performance of the new trap than the two conventional traps, even though the sizes of some of the fish species caught in all the traps were below those allowed by the Sokoto State Fisheries Edict where the study was conducted. Therefore, since it is desirable to develop conservation-oriented trap at a least cost, it is necessary to research further on the number of valves and mesh size of the new trap
Resumo:
介绍了一种高重复频率掺钛蓝宝石飞秒激光多通高效率放大系统.在抽运功率为23W,入射功率为660mW时,获得7.2W的放大输出,放大效率达30%.经压缩器压缩后,获得单脉冲能量4.5mJ,脉冲宽度为38fs,重复频率为1kHz,峰值功率大于0.1TW的超短超强激光脉冲.
Resumo:
Anticoagulantes orais são amplamente indicados para prevenção de eventos tromboembólicos. No entanto, nem sempre os pacientes atingem a faixa terapêutica recomendada. Os objetivos desse estudo foram avaliar a associação entre periodontite e níveis de anticoagulação (fase 1) e o efeito do tratamento periodontal nos níveis de anticoagulação (fase 2) em pacientes que faziam uso do anticoagulante oral varfarina. O exame clínico incluiu índice CPO-D, índice de placa, sangramento à sondagem, profundidade de bolsa e nível de inserção clínica. Coeficiente normalizado internacional (INR), níveis de albumina, proteína C-reativa (PCR) e fibrinogênio foram avaliados no dia zero e até 180 dias após tratamento periodontal. Na fase 1 do estudo foram examinados 62 pacientes (42 mulheres e 20 homens, com idade média de 50,8 9,2 anos). Observamos uma correlação negativa entre extensão e severidade da doença periodontal e índice de placa com valores de INR. Não houve associação entre diagnóstico periodontal e níveis de anticoagulação. Dentre os pacientes fora do alvo terapêutico, 87% apresentavam diagnóstico de periodontite, enquanto no grupo na faixa terapêutica apenas 56%. Participaram da fase 2 do estudo 26 pacientes com periodontite severa (15 mulheres e 11 homens, com idade média de 51,3 9,2 anos). O tratamento periodontal resultou em melhora significativa de todos os parâmetros periodontais e dos níveis de anticoagulação 30, 60 90 e 180 dias após conclusão da terapia periodontal. Não houve alteração significativa na dose semanal da varfarina. Foi observada redução significativa entre níveis séricos de albumina dos dia 90 e 180 após a terapia periodontal, quando comparado aos valores do dia 0 (p < 0,05). De acordo com o alvo terapêutico estabelecido, observamos que no dia 0 doze pacientes (46,15%) estavam fora dessa faixa. Esse percentual foi reduzido significativamente após tratamento periodontal, sendo 26,1% e 29,2% nos dias 60 e 90, respectivamente. Embora tenha ocorrido melhora nos níveis de anticoagulação, não houve alteração significativa nos níveis de PCR e fibrinogênio. Sendo assim, pacientes com periodontite severa podem apresentar dificuldade para atingir a faixa terapêutica e o tratamento periodontal pode resultar em benefícios na busca da anticoagulação plena. Novos estudos são necessários para avaliar se formas menos severas de doença periodontal também podem interferir com a varfarina.
Resumo:
反射式光栅对是一种具有负色散性质的器件,可用于飞秒激光脉冲的压缩和展宽,具有无材料色散的优点。给出了一种基于多台阶反射光栅的脉冲压缩装置。该装置为倍密度光栅结构,由两个周期分别为40μm和20μm的四台阶反射式光栅组成。实验得到的衍射效率可以达到70%以上,输入脉冲经过两个光栅的衍射后会按原路返回,从而达到色散补偿的效果。利用此压缩装置,脉冲宽度为66.8 fs的输入脉冲压缩至接近傅里叶变换极限脉冲,即46.6 fs,由此证明只要多台阶光栅效率足够高,此装置就有可能成为不同于棱镜对进行飞秒脉冲腔内和腔外压缩的另一种途径。
Resumo:
O presente estudo teve como objetivo quantificar as emissões de Compostos Orgânicos Voláteis do Aterro Controlado Morro do Céu localizado na cidade de Niterói, Rio de Janeiro, Brasil. Para tanto, vinte amostras foram coletadas, usando uma bomba de ar operada a bateria durante dois dias de dezembro de 2009. Uma câmara de fluxo cilíndrica de PVC de 30L foi inserida 5 cm no solo do aterro, e as amostras foram coletadas através de uma válvula na parte superior da câmera. Os resultados indicaram um valor de 1.980 Kg Km-2 h-1. O modelo Gaussiano de dispersão atmosférica ISCST3 foi utilizado para calcular a difusão e transporte dos poluentes a fim de estimar as concentrações de COV no bairro, usando dados topográficos, meteorológicos e de emissões. Valores de 525 μg m-3 de COV foram encontrados a 500 metros do aterro. As emissões do aterro foram usadas em conjunto com dados meteorológicos, utilizando o modelo de trajetória OZIPR e o mecanismo químico SAPRC para demonstrar o impacto na formação do ozônio troposférico na região. É conhecido que o ozônio é formado pela reação entre COV, NOx e luz solar. A contribuição de valores elevados de COV provenientes das emissões do aterro conduzirá a uma nova situação com valores mais elevados de ozônio na região. Os resultados da modelagem indicaram um aumento maior que 1000% nos níveis de ozônio na região do aterro, se comparado com a modelagem do ozônio para a região metropolitana do Rio de Janeiro. Os resultados mostram ser necessário que maior atenção seja dada à política de gerenciamento de RSU no Brasil, incluindo a escolha adequada para o local de instalação, o monitoramento da área durante e após o período de operação e técnicas mais adequadas de disposição dos resíduos sólidos urbanos
Resumo:
Adjustment of experimental channels to give any specified pattern of water depth or velocity is complex and tedious because it involves a number of variables. Since some variables are not controllable and variables may interact, valve settings of the Grassholme channels were initially determined on an ad hoc basis to suit individual experiments. This method was used during 1982 but additional observations were made in order to gain more detailed understanding of the channel system and, as far as possible, to develop a guide to future short-cuts in attaining suitable channel settings for any given purpose. This report describes calibration of the Grassholme channels (using water of the Grassholme Reservoir) for the biological experiments of spring - summer 1982. The main variables that are discussed are valve turns and discharge and velocity and depth. It also seeks to establish relationships which will be of value in future managment of the channels for experimental purposes.
Resumo:
The design of a two-stream wind tunnel was undertaken to allow the simulation and study of certain features of the flow field around the blades of high-speed axial-flow turbomachineries. The mixing of the two parallel streams with designed Mach numbers respectively equal to 1.4 and 0.7 will simulate the transonic Mach number distribution generally obtained along the tips of the first stage blades in large bypass-fan engines.
The GALCIT hypersonic compressor plant will be used as an air supply for the wind tunnel, and consequently the calculations contained in the first chapter are derived from the characteristics and the performance of this plant.
The transonic part of the nozzle is computed by using a method developed by K. O. Friedrichs. This method consists essentially of expanding the coordinates and the characteristics of the flow in power series. The development begins with prescribing, more or less arbitrarily, a Mach number distribution along the centerline of the nozzle. This method has been programmed for an IBM 360 computer to define the wall contour of the nozzle.
A further computation is carried out to correct the contour for boundary layer buildup. This boundary layer analysis included geometry, pressure gradient, and Mach number effects. The subsonic nozzle is calculated {including boundary layer buildup) by using the same computer programs. Finally, the mixing zone downstream of the splitter plate was investigated to prescribe the wall contour correction necessary to ensure a constant-pressure test section.
Resumo:
In petawatt laser system, the gratings used to compose pulse compressor are very large in size which can be only acquired currently by arraying small aperture gratings to form a large one instead, an approach referred to as grating tiling. Theory and experiments have demonstrated that the coherent addition of multiple small gratings to form a larger grating is viable, the key technology of which is to control the relative position and orientation of each grating with high precision. According to the main factors that affect the performance of the grating tiling, a 5-DOF ultraprecision stage is developed for the grating tiling experiment. The mechanism is formed by serial structures. The motion of the mechanism is guided by flexure hinges and driven by piezoelectric actuators and the movement resolution of which can achieve nanometer level. To keep the stability of the mechanism, capacitive position sensors with nanometer accuracy are fixed on it to provide feedback signals with which to realize closed-loop control, thus the positioning precision of the mechanism is within several nanometers range through voltage control and digital PID algorithm. Results of experiments indicate that the performance of the mechanism can meet the requirement of precision for grating tiling.}