973 resultados para Carbon loss
Resumo:
The Driver Behaviour Questionnaire (DBQ) continues to be the most widely utilised self-report scale globally to assess crash risk and aberrant driving behaviours among motorists. However, the scale also attracts criticism regarding its perceived limited ability to accurately identify those most at risk of crash involvement. This study reports on the utilisation of the DBQ to examine the self-reported driving behaviours (and crash outcomes) of drivers in three separate Australian fleet samples (N = 443, N = 3414, & N = 4792), and whether combining the samples increases the tool’s predictive ability. Either on-line or paper versions of the questionnaire were completed by fleet employees in three organisations. Factor analytic techniques identified either three or four factor solutions (in each of the separate studies) and the combined sample produced expected factors of: (a) errors, (b) highway-code violations and (c) aggressive driving violations. Highway code violations (and mean scores) were comparable across the studies. However, across the three samples, multivariate analyses revealed that exposure to the road was the best predictor of crash involvement at work, rather than DBQ constructs. Furthermore, combining the scores to produce a sample of 8649 drivers did not improve the predictive ability of the tool for identifying crashes (e.g., 0.4% correctly identified) or for demerit point loss (0.3%). The paper outlines the major findings of this comparative sample study in regards to utilising self-report measurement tools to identify “at risk” drivers as well as the application of such data to future research endeavours.
Resumo:
We reported the thermal conductivity of the two-dimensional carbon nanotube (CNT)-based architecture, which can be constructed through welding of single-wall CNTs by electron beam. Using large-scale nonequilibrium molecular dynamics simulations, the thermal conductivity is found to vary with different junction types due to their different phonon scatterings at the junction. The strong length and strain dependence of the thermal conductivity suggests an effective avenue to tune the thermal transport properties of the CNT-based architecture, benefiting the design of nanoscale thermal rectifiers or phonon engineering.
Resumo:
Flexible graphene-based thin film supercapacitors were made using carbon nanotube (CNT) films as current collectors and graphene films as electrodes. The graphene sheets were produced by simple electrochemical exfoliation, while the graphene films with controlled thickness were prepared by vacuum filtration. The solid-state supercapacitor was made by using two graphene/CNT films on plastic substrates to sandwich a thin layer of gelled electrolyte. We found that the thin graphene film with thickness <1 μm can greatly increase the capacitance. Using only CNT films as electrodes, the device exhibited a capacitance as low as ~0.4 mF cm−2, whereas by adding a 360 nm thick graphene film to the CNT electrodes led to a ~4.3 mF cm−2 capacitance. We experimentally demonstrated that the conductive CNT film is equivalent to gold as a current collector while it provides a stronger binding force to the graphene film. Combining the high capacitance of the thin graphene film and the high conductivity of the CNT film, our devices exhibited high energy density (8–14 Wh kg−1) and power density (250–450 kW kg−1).
Resumo:
The aims of the project were to scope and develop sustainable energy curriculum frameworks for Australian higher education Institutions that meet the needs of Australian and international student graduates and employers, both now and into the near future. The focus was on student centred learning and outcomes and to support graduates with the knowledge, skills and generic attributes required to work in the rapidly expanding sustainable energy industry in Australia and globally. The outputs of the project are designed to be relevant to specialist Sustainable Engineering and Energy Studies programs, as well as conventional engineering, science and humanities and social science programs that have a sustainable energy focus or major.
Resumo:
Glassy carbon (GC) electrode modified with a self-assembled monolayer (SAM) of 1,8,15,22-tetraaminophthalocyanatocobalt(II) (4α-CoIITAPc) was used for the selective and highly sensitive determination of nitric oxide (NO). The SAM of 4α-CoIITAPc was formed on GC electrode by spontaneous adsorption from DMF containing 1 mM 4α-CoIITAPc. The SAM showed two pairs of well-defined redox peaks corresponding to CoIII/CoII and CoIIIPc−1/CoIIIPc−2 in 0.2 M phosphate buffer (PB) solution (pH 2.5). The SAM modified electrode showed excellent electrocatalytic activity towards the oxidation of nitric oxide (NO) by enhancing its oxidation current with 310 mV less positive potential shift when compared to bare GC electrode. In amperometric measurements, the current response for NO oxidation was linearly increased in the concentration range of 3×10−9 to 30×10−9 M with a detection limit of 1.4×10−10 M (S/N=3). The proposed method showed a better recovery for NO in human blood serum samples.
Resumo:
Spontaneous adsorption of 1,8,15,22-tetraaminophthalocyanatocobalt(II) (4α-CoIITAPc) on glassy carbon (GC) electrode leads to the formation of a stable self-assembled monolayer (SAM). Since the SAM of 4α-CoIITAPc is redox active, its adsorption on GC electrode was followed by cyclic voltammetry. SAM of 4α-CoIITAPc on GC electrode shows two pairs of well-defined redox peaks corresponding to CoIII/CoII and CoIIIPc−1/CoIIIPc−2. The surface coverage (Γ) value, calculated by integrating the charge under CoII oxidation, was used to study the adsorption thermodynamics and kinetics of 4α-CoIITAPc on GC surface. Cyclic voltammetric studies show that the adsorption of 4α-CoIITAPc on GC electrode has reached the saturation coverage (Γs) within 3 h. The Γs value for the SAM of 4α-CoIITAPc on GC electrode was found to be 2.37 × 10−10 mol cm−2. Gibbs free energy (ΔGads) and adsorption rate constant (kad) for the adsorption of 4α-CoIITAPc on GC surface were found to be −16.76 kJ mol−1 and 7.1 M−1 s−1, respectively. The possible mechanism for the self-assembly of 4α-CoIITAPc on GC surface is through the addition of nucleophilic amines to the olefinic bond on the GC surface in addition to a meager contribution from π stacking. The contribution of π stacking was confirmed from the adsorption of unsubstituted phthalocyanatocobalt(II) (CoPc) on GC electrode. Raman spectra for the SAM of 4α-CoIITAPc on carbon surface shows strong stretching and breathing bands of Pc macrocycle, pyrrole ring and isoindole ring. Raman and CV studies suggest that 4α-CoIITAPc is adopting nearly a flat orientation or little bit tilted orientation.
Resumo:
Electropolymerized film of 3,3′,3″,3‴-tetraaminophthalocyanatonickel(II) (p-NiIITAPc) on glassy carbon (GC) electrode was used for the selective and stable determination of 3,4-dihydroxy-l-phenylalanine (l-dopa) in acetate buffer (pH 4.0) solution. Bare GC electrode fails to determine the concentration of l-dopa accurately in acetate buffer solution due to the cyclization reaction of dopaquinone to cyclodopa in solution. On the other hand, p-NiIITAPc electrode successfully determines the concentration of l-dopa accurately because the cyclization reaction was prevented at this electrode. It was found that the electrochemical reaction of l-dopa at the modified electrode is faster than that at the bare GC electrode. This was confirmed from the higher heterogeneous electron transfer rate constant (k0) of l-dopa at p-NiIITAPc electrode (3.35 × 10−2 cm s−1) when compared to that at the bare GC electrode (5.18 × 10−3 cm s−1). Further, it was found that p-NiIITAPc electrode separates the signals of ascorbic acid (AA) and l-dopa in a mixture with a peak separation of 220 mV. Lowest detection limit of 100 nM was achieved at the modified electrode using amperometric method. Common physiological interferents like uric acid, glucose and urea does not show any interference within the potential window of l-dopa oxidation. The present electrode system was also successfully applied to estimate the concentration of l-dopa in the commercially available tablets.
Resumo:
This study examines the role that the size of a victimised organisation and the size of the victim’s loss have on attitudes regarding the acceptance or unacceptance of 12 questionable consumer actions. A sample of 815 American adults rated each scenario on a scale anchored by very acceptable and very unacceptable. It was shown that the size of the victimised organisation tends to influence consumers’ opinions with more disdain directed towards consumers who take advantage of smaller businesses. Similarly, the respondents tended to be more critical of these actions when the loss incurred by the victimised organisation was large. A 2x2 matrix concurrently delineated the nature of the extent to which opinions regarding the 12 actions differed depending upon the mediating variable under scrutiny.
Resumo:
Most surgeons cement the tibial component in total knee replacement surgery. Mid-term registry data from a number of countries, including those from the United Kingdom and Australia, support the excellent survivorship of cemented tibial components. In spite of this success, results can always be improved, and cementing technique can play a role. Cementing technique on the tibia is not standardized, and surgeons still differ about the best ways to deliver cement into the cancellous bone of the upper tibia. Questions remain regarding whether to use a gun or a syringe to inject the cement into the cancellous bone of the tibial plateau . The ideal cement penetration into the tibial plateau is debated, though most reports suggest that 4 mm to 10 mm is ideal. Thicker mantles are thought to be dangerous due to the risk of bone necrosis, but there is little in the literature to support this contention...
Resumo:
Purpose Endometrial adenocarcinoma (EC) is the most common gynaecologic cancer. Up to 90% of EC patients are obese which poses a health threat to patients post-treatment. Standard treatment for EC includes hysterectomy, although this has significant side effects for obese women at high risk of surgical complications and for women of childbearing age. This trial investigates the effectiveness of non-surgical or conservative treatment options for obese women with early stage EC. The primary aim is to determine the efficacy of: levonorgestrel intrauterine device (LNG-IUD); with or without metformin (an antidiabetic drug); and with or without a weight loss intervention to achieve a pathological complete response (pCR) in EC at six months from study treatment initiation. The secondary aim is to enhance understanding of the molecular processes and to predict a treatment response by investigating EC biomarkers. Methods An open label, three-armed, randomised, phase-II, multi-centre trial of LNG-IUD ± metformin ± weight loss intervention. 165 participants from 28 centres are randomly assigned in a 3:3:5 ratio to the treatment arms. Clinical, quality of life and health behavioural data will be collected at baseline, six weeks, three and six months. EC biomarkers will be assessed at baseline, three and six months. Conclusions There is limited prospective evidence for conservative treatment for EC. Trial results could benefit patients and reduce health system costs through a reduction in hospitalisations and through lower incidence of adverse events currently observed with standard treatment.
Resumo:
We fabricated high performance supercapacitors by using all carbon electrodes, with volume energy in the order of 10−3 Whcm−3, comparable to Li-ion batteries, and power densities in the range of 10 Wcm−3, better than laser-scribed-graphene supercapacitors. All-carbon supercapacitor electrodes are made by solution processing and filtering electrochemically-exfoliated graphene sheets mixed with clusters of spontaneously entangled multiwall carbon nanotubes. We maximize the capacitance by using a 1:1 weight ratio of graphene to multi-wall carbon nanotubes and by controlling their packing in the electrode film so as to maximize accessible surface and further enhance the charge collection. This electrode is transferred onto a plastic-paper-supported double-wall carbon nanotube film used as current collector. These all-carbon thin films are combined with plastic paper and gelled electrolyte to produce solid-state bendable thin film supercapacitors. We assembled supercapacitor cells in series in a planar configuration to increase the operating voltage and find that the shape of our supercapacitor film strongly affects its capacitance. An in-line superposition of rectangular sheets is superior to a cross superposition in maintaining high capacitance when subject to fast charge/discharge cycles. The effect is explained by addressing the mechanism of ion diffusion into stacked graphene sheets.