968 resultados para CT scan
Resumo:
Multi-phase postmortem CT angiography (MPMCTA) is recognized as a valuable tool to explore the vascular system, with higher sensitivity than conventional autopsy. However, a limitation is the impossibility to diagnose pulmonary embolism (PE) due to post-mortem blood clots situated in pulmonary arteries. The purpose of this study was to explore an eventual possibility to distinguish between real PE and artefacts mimicking PE. Our study included 416 medico-legal cases. All of them underwent MPMCTA, conventional autopsy and histological examination. We selected cases presenting arterial luminal filling defects in the pulmonary arteries. Their radiological interpretation was confronted to the one of autopsy and histological examination. We also investigated an eventual correlation between artefacts in pulmonary arteries and those in other parts of the vascular system. In 123 cases, filling defects of pulmonary arteries were described during MPMCTA. In 57 cases, this was interpreted as artefact and in 4 cases as suspected PE. In 62 cases only a differential diagnosis was made. Autopsy and histology could clearly identify the artefacts as such. Only one case of real PE was radiologically misinterpreted as artefact. In 6 of the 62 cases with no interpretation a PE was diagnosed. In 3 out of 4 suspected cases, PE was confirmed. We found out that filling defects in pulmonary arteries are nearly always associated to other vascular artefacts. Therefore, we suggest following some rules for radiological interpretation in order to allow a reliable diagnosis of pulmonary embolism after MPMCTA.
Resumo:
BACKGROUND: The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO(TM) is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. OBJECTIVE: To evaluate the potential of VEO(TM) on diagnostic image quality and dose reduction in pediatric chest CT examinations. MATERIALS AND METHODS: Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDIvol 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. RESULTS: At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. CONCLUSIONS: At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection.
Resumo:
Purpose: To compare MDCT, MRI and 18F-FDG PET/CT for the detection of peritoneal carcinomatosis due to ovarian cancerMethods and Materials: Fifteen women (mean age 65±) with clinical suspicion of ovarian cancer and peritoneal carcinomatosis underwent MDCT, MRI and 18F-FDG PET/CT, simultaneously and shortly performed before surgery (delay 8.1± days). According to the peritoneal cancer index nine abdominopelvic regions were defined. We applied four scores of lesion size on MDCT and MR images, while the maximal standard uptake value (SUVmax) was measured on 18F-FDG PET/CT. Three sites of lymphadenopathy and posterobasal pleural carcinomatosis were also analyzed. First, one radiologist blindly and separately read MDCT and MR images, while one nuclear physician blindly read PET/CT images grading each lesion according to four diagnostic certitudes. Secondly, all the images were reviewed jointly and compared with histopathology. Receiver operating characteristics (ROC) analysis was performed.Results: Peritoneal implants were proven in ten women (75%). Altogether, 228 abdominopelvic sites were compared. Sensitivity and specificity for MDCT was 90.2% and 90.6%, for MRI 93.5% and 86.3%, and for 18F-FDG PET/CT 92.7% and 95.7%, respectively. ROC area under the curve were 0.93 for MDCT and MRI, and 0.96 for 18F-FDG PET/CT respectively. No significant differences (p=0.11) were found between the three modalities.Conclusion: Although MRI revealed to be the most sensitive and 18F-FDG PET/CT the most specific modality, no significant differences were shown between the three techniques.
Resumo:
A precise classification and an optimal understanding of tibial plateau fractures are the basis of a conservative treatment or adequate surgery. The aim of this prospective study is to determine the contribution of 3D CT to the classification of fractures (comparison with standard X-rays) and as an aid to the surgeon in preoperative planning and surgical reconstruction. Between November 1994 and July 1996, 20 patients presenting 22 tibial plateau fractures were considered in this study. They all underwent surgical treatment. The fractures were classified according to the Müller AO classification. They were all investigated by means of standard X-rays (AP, profile, oblique) and the 3D CT. Analysis of the results has shown the superiority of 3D CT in the planning (easier and more acute), in the classification (more precise), and in the exact assessment of the lesions (quantity of fragments); thereby proving to be of undeniable value of the surgeon.
Resumo:
We present a 53-year-old man with a vocal cord paralysis observed as a primary manifestation of lung carcinoma. Tc-99m MDP whole body bone scan were performed and resulted a normal scintiscan. The bone scan does not revealed suspicious foci of uptake. The possibility of bone metastasis was taken into consideration. A whole body F18-FDG-PET scan showed intense uptake in the left upper lung corresponding to the primary tumor. A bronchial biopsy confirmed infiltration by small cell lung carcinoma (SCLC). SCLC is composed of poorly differentiated, rapidly growing cells with disease usually occurring centrally rather than peripherally. It metastasizes early. The whole-body F18-FDG-PET scan clearly demonstrated a focus of increased uptake in the second lumbar vertebral body suspicious for osteolytic metastasis. A lytic bone metastasis was confirmed by MRI. The patient then received therapy and underwent follow up abdominal CT. The scan showed blastic changes in the L2 vertebra suggesting response to treatment.
Resumo:
BACKGROUND AND PURPOSE: Patients with symptoms of semicircular canal dehiscence often undergo both CT and MR imaging. We assessed whether FIESTA can replace temporal bone CT in evaluating patients for SC dehiscence. MATERIALS AND METHODS: We retrospectively reviewed 112 consecutive patients (224 ears) with vestibulocochlear symptoms who underwent concurrent MR imaging and CT of the temporal bones between 2007 and 2009. MR imaging protocol included a FIESTA sequence covering the temporal bone (axial 0.8-mm section thickness, 0.4-mm spacing, coronal/oblique reformations; 41 patients at 1.5T, 71 patients at 3T). CT was performed on a 64-row multidetector row scanner (0.625-mm axial acquisition, with coronal/oblique reformations). Both ears of each patient were evaluated for dehiscence of the superior and posterior semicircular canals in consensual fashion by 2 neuroradiologists. Analysis of the FIESTA sequence and reformations was performed first for the MR imaging evaluation. CT evaluation was performed at least 2 weeks after the MR imaging review, resulting in a blinded comparison of CT with MR imaging. CT was used as the reference standard to evaluate the MR imaging results. RESULTS: For SSC dehiscence, MR imaging sensitivity was 100%, specificity was 96.5%, positive predictive value was 61.1%, and negative predictive value was 100% in comparison with CT. For PSC dehiscence, MR imaging sensitivity was 100%, specificity was 99.1%, positive predictive value was 33.3%, and negative predictive value was 100% in comparison with CT. CONCLUSIONS: MR imaging, with a sensitivity and negative predictive value of 100%, conclusively excludes SSC or PSC dehiscence. Negative findings on MR imaging preclude the need for CT to detect SC dehiscence. Only patients with positive findings on MR imaging should undergo CT evaluation.
Resumo:
PURPOSE: To evaluate the technical quality and the diagnostic performance of a protocol with use of low volumes of contrast medium (25 mL) at 64-detector spiral computed tomography (CT) in the diagnosis and management of adult, nontraumatic subarachnoid hemorrhage (SAH). MATERIALS AND METHODS: This study was performed outside the United States and was approved by the institutional review board. Intracranial CT angiography was performed in 73 consecutive patients with nontraumatic SAH diagnosed at nonenhanced CT. Image quality was evaluated by two observers using two criteria: degree of arterial enhancement and venous contamination. The two independent readers evaluated diagnostic performance (lesion detection and correct therapeutic decision-making process) by using rotational angiographic findings as the standard of reference. Sensitivity, specificity, and positive and negative predictive values were calculated for patients who underwent CT angiography and three-dimensional rotational angiography. The intraclass correlation coefficient was calculated to assess interobserver concordance concerning aneurysm measurements and therapeutic management. RESULTS: All aneurysms were detected, either ruptured or unruptured. Arterial opacification was excellent in 62 cases (85%), and venous contamination was absent or minor in 61 cases (84%). In 95% of cases, CT angiographic findings allowed optimal therapeutic management. The intraclass correlation coefficient ranged between 0.93 and 0.95, indicating excellent interobserver agreement. CONCLUSION: With only 25 mL of iodinated contrast medium focused on the arterial phase, 64-detector CT angiography allowed satisfactory diagnostic and therapeutic management of nontraumatic SAH.
Resumo:
Objective. The goal of this study was to present the pathological and radiological patterns of "vulnerable" atherosclerotic plaques in cases of sudden cardiac death. Method. This retrospective study was performed on forensic cases for which the cause of death was attributed to coronary artery disease. A complete autopsy was performed in all cases, along with either post-mortem CT-angiography, toxicological analyses and/or biochemistry. Results. 89 cases were selected (mean age 55±11.6 years; 75 men and 14 women). In 96.6% of cases a CT-angiography was performed. Acute coronary lesions were found in 60 cases (mean age 53±11.1 years), which included plaque erosion in 26 cases (mean age 47±8.3 years) and ruptures or intraplaque hemorrhage in 33 cases (mean age 58±10.4 years). Erosions were most frequently found in the left ascending artery (61.5 %), while only 36% of ruptures were observed in this artery. Chronic coronary pathology was described in 30 cases (mean age 58±10.4 years). CT-angiographies performed prior to the autopsy enabled an initial evaluation of coronary artery perfusion. Conclusion. In the face of decreasing clinical autopsy rates, postmortem studies on forensic autopsies, including modern radiological examinations, allow for a more thorough understanding of the clinical picture of disease which can result in sudden cardiac death.
Resumo:
AIMS: This study was performed to compare the sensitivity of ultrasonography, computerized tomography during arterial portography, delayed computerized tomography, and magnetic resonance imaging to detect focal liver lesions. Forty three patients with primary or secondary malignant liver lesions were studied prior to surgical intervention. METHODS: The results of the imaging studies were compared with intraoperative examination of the liver, intraoperative ultrasonography and pathology results (29 patients). In the non-operated (14 patients) group, we compared the number of lesions detected by each technique. RESULTS: One hundred and forty six lesions were detected. There was 84% sensitivity with computerized tomography during arterial portography, 61.3% with delayed scan, 63.3% with magnetic resonance imaging and 51% with ultrasonography in operated patients. In patients who did not undergo surgery, magnetic resonance imaging was more sensitive in detecting lesions. CONCLUSIONS: In operated and non-operated patients series, CT during arterial portography had the highest sensitivity, but magnetic resonance imaging had the most consistent overall results.
Resumo:
Brain perfusion can be assessed by CT and MR. For CT, two major techniquesare used. First, Xenon CT is an equilibrium technique based on a freely diffusibletracer. First pass of iodinated contrast injected intravenously is a second method,more widely available. Both methods are proven to be robust and quantitative,thanks to the linear relationship between contrast concentration and x-ray attenuation.For the CT methods, concern regarding x-ray doses delivered to the patientsneed to be addressed. MR is also able to assess brain perfusion using the firstpass of gadolinium based contrast agent injected intravenously. This method hasto be considered as a semi-quantitative because of the non linear relationshipbetween contrast concentration and MR signal changes. Arterial spin labelingis another MR method assessing brain perfusion without injection of contrast. Insuch case, the blood flow in the carotids is magnetically labelled by an externalradiofrequency pulse and observed during its first pass through the brain. Eachof this various CT and MR techniques have advantages and limits that will be illustratedand summarised.Learning Objectives:1. To understand and compare the different techniques for brain perfusionimaging.2. To learn about the methods of acquisition and post-processing of brainperfusion by first pass of contrast agent for CT and MR.3. To learn about non contrast MR methods (arterial spin labelling).
Resumo:
BACKGROUND: To identify patients with spontaneous subarachnoid hemorrhage for whom CT angiography alone can exclude ruptured aneurysms. METHODS: An observational retrospective review was carried out of all consecutive patients with non-traumatic subarachnoid hemorrhage who underwent both CT angiography and catheter angiography to exclude an aneurysm. CT angiography negative cases (no aneurysm) were classified according to their CT hemorrhage pattern as "aneurismal", "perimesencephalic" or as "no-hemorrhage." RESULTS: Two hundred and forty-one patients were included. A CT angiography aneurysm detection sensitivity and specificity of 96.4% and 96.0% were observed. All 35 cases of perimesencephalic or no-hemorrhage out of 78 CT angiography negatives also had negative angiography findings. CONCLUSIONS: CT angiography is self-reliant to exclude ruptured aneurysms when either a perimesencephalic hemorrhage or no-hemorrhage pattern is identified on the CT within a week of symptom onset.
Resumo:
Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 912 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. PassingBablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis
Resumo:
This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDI(vol)) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDI(vol): 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.