965 resultados para Biomedical engineering|Nanoscience


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study has as general aim to propose a spatial map of doses as an auxiliary tool in assessing the need for optimization of the workplace in nuclear medicine services. As specific aims, we assessed the workers individual dosimetry; we analyzed the facilities of the nuclear medicine services; and we evaluated environment exposure rates. The research is characterized as a case study, with an exploratory and explanatory nature. It was conducted in three Nuclear Medicine Services, all established in the Northwest of the Paraná State. Results indicated that the evaluated dose rates and workers dosimetry, in all the dependencies of the surveyed services, are within the limits of annual doses. However some exceeded the limits recommended in the standard CNEN-NN 3:01 (2014). It was concluded that the spatial map dose is an important tool for nuclear medicine services because it facilitates the visualization of areas with highest concentration of radiation, and also helps in the constant review of these measures and resources, aiding in the identification of any failures and shortcomings, providing resources to correct any issues and prevent their repetition. The spatial map dose is also important for the regular inspection, evaluating if the radiation protection objectives are being met.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Among other causes the long-term result of hip prostheses in dogs is determined by aseptic loosening. A prevention of prosthesis complications can be achieved by an optimization of the tribological system which finally results in improved implant duration. In this context a computerized model for the calculation of hip joint loadings during different motions would be of benefit. In a first step in the development of such an inverse dynamic multi-body simulation (MBS-) model we here present the setup of a canine hind limb model applicable for the calculation of ground reaction forces. Methods: The anatomical geometries of the MBS-model have been established using computer tomography- (CT-) and magnetic resonance imaging- (MRI-) data. The CT-data were collected from the pelvis, femora, tibiae and pads of a mixed-breed adult dog. Geometric information about 22 muscles of the pelvic extremity of 4 mixed-breed adult dogs was determined using MRI. Kinematic and kinetic data obtained by motion analysis of a clinically healthy dog during a gait cycle (1 m/s) on an instrumented treadmill were used to drive the model in the multi-body simulation. Results and Discussion: As a result the vertical ground reaction forces (z-direction) calculated by the MBS-system show a maximum deviation of 1.75%BW for the left and 4.65%BW for the right hind limb from the treadmill measurements. The calculated peak ground reaction forces in z- and y-direction were found to be comparable to the treadmill measurements, whereas the curve characteristics of the forces in y-direction were not in complete alignment. Conclusion: In conclusion, it could be demonstrated that the developed MBS-model is suitable for simulating ground reaction forces of dogs during walking. In forthcoming investigations the model will be developed further for the calculation of forces and moments acting on the hip joint during different movements, which can be of help in context with the in silico development and testing of hip prostheses.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: There are several numerical investigations on bone remodelling after total hip arthroplasty (THA) on the basis of the finite element analysis (FEA). For such computations certain boundary conditions have to be defined. The authors chose a maximum of three static load situations, usually taken from the gait cycle because this is the most frequent dynamic activity of a patient after THA. Materials and methods: The numerical study presented here investigates whether it is useful to consider only one static load situation of the gait cycle in the FE calculation of the bone remodelling. For this purpose, 5 different loading cases were examined in order to determine their influence on the change in the physiological load distribution within the femur and on the resulting strain-adaptive bone remodelling. First, four different static loading cases at 25%, 45%, 65% and 85% of the gait cycle, respectively, and then the whole gait cycle in a loading regime were examined in order to regard all the different loadings of the cycle in the simulation. Results: The computed evolution of the apparent bone density (ABD) and the calculated mass losses in the periprosthetic femur show that the simulation results are highly dependent on the chosen boundary conditions. Conclusion: These numerical investigations prove that a static load situation is insufficient for representing the whole gait cycle. This causes severe deviations in the FE calculation of the bone remodelling. However, accompanying clinical examinations are necessary to calibrate the bone adaptation law and thus to validate the FE calculations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

One of the challenges to biomedical engineers proposed by researchers in neuroscience is brain machine interaction. The nervous system communicates by interpreting electrochemical signals, and implantable circuits make decisions in order to interact with the biological environment. It is well known that Parkinson’s disease is related to a deficit of dopamine (DA). Different methods has been employed to control dopamine concentration like magnetic or electrical stimulators or drugs. In this work was automatically controlled the neurotransmitter concentration since this is not currently employed. To do that, four systems were designed and developed: deep brain stimulation (DBS), transmagnetic stimulation (TMS), Infusion Pump Control (IPC) for drug delivery, and fast scan cyclic voltammetry (FSCV) (sensing circuits which detect varying concentrations of neurotransmitters like dopamine caused by these stimulations). Some softwares also were developed for data display and analysis in synchronously with current events in the experiments. This allowed the use of infusion pumps and their flexibility is such that DBS or TMS can be used in single mode and other stimulation techniques and combinations like lights, sounds, etc. The developed system allows to control automatically the concentration of DA. The resolution of the system is around 0.4 µmol/L with time correction of concentration adjustable between 1 and 90 seconds. The system allows controlling DA concentrations between 1 and 10 µmol/L, with an error about +/- 0.8 µmol/L. Although designed to control DA concentration, the system can be used to control, the concentration of other substances. It is proposed to continue the closed loop development with FSCV and DBS (or TMS, or infusion) using parkinsonian animals models.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, a platform to the conditioning, digitizing, visualization and recording of the EMG signals was developed. After the acquisition, the analysis can be done by signal processing techniques. The platform consists of two modules witch acquire electromyography (EMG) signals by surface electrodes, limit the interest frequency band, filter the power grid interference and digitalize the signals by the analogue-to- digital converter of the modules microcontroller. Thereby, the data are sent to the computer by the USB interface by the HID specification, displayed in real-time in graphical form and stored in files. As processing resources was implemented the operations of signal absolute value, the determination of effective value (RMS), Fourier analysis, digital filter (IIR) and the adaptive filter. Platform initial tests were performed with signal of lower and upper limbs with the aim to compare the EMG signal laterality. The open platform is intended to educational activities and academic research, allowing the addition of other processing methods that the researcher want to evaluate or other required analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Following a drop in estrogen in the period of menopause some women begin to lose bone mass more than 1% per year reaching the end of five years with loss greater than 25%. In this regard, factors such as older age, low calcium intake and premature menopause favor the onset of osteoporosis. Preventive methods such as nutritional counseling to a proper diet and the support of technology through applications that assess dietary intake are essential. Thus, this study aimed to develop an application for Android® platform focused on the evaluation of nutritional and organic conditions involved in bone health and risks for developing osteoporosis in postmenopausal women. To achieve this goal we proceeded to a study of 72 women aged 46-79 years, from the physical exercise for bone health of the Laboratory for Research in Biochemistry and Densitometry the Federal Technological University of Paraná program. Data were collected in the second half of 2014 through tests Bone Densitometry and Body Composition, Blood Tests, Anthropometric data and Nutrition Assessment. The study included women with a current diagnosis of osteopenia or osteoporosis primary, aged more than 45 years postmenopausal. For the assessment of bone mineral density and body composition used the device Absorptiometry Dual Energy X-ray (DXA) brand Hologic Discovery TM Model A. For anthropometric assessment was included to body mass, height, abdominal circumference, Waist circumference and hip circumference. The instrument for assessing food consumption was used Recall 24 hours a day (24HR). The estimated intake of energy and nutrients was carried from the tabulation of the food eaten in the Software Diet Pro 4®. In a sub sample of 30 women with osteopenia / osteoporosis serum calcium and alkaline phosphatase tests were performed. The results demonstrated a group of women (n = 30) average calcium intake of 570mg / day (± 340). The analysis showed a mean serum calcium within the normal range (10,20mg / dl ± 0.32) and average values and slightly increased alkaline phosphatase (105.40 U / L ± 23.70). Furthermore, there was a significant correlation between the consumption of protein and the optimal daily intake of calcium (0.375 p-value 0.05). Based on these findings, we developed an application early stage in Android® platform operating system Google®, being called OsteoNutri. We chose to use Java Eclipse® where it was executed Android® version of the project; choice of application icons and setting the visual editor for building the application layouts. The DroidDraw® was used for development of the three application GUIs. For practical tests we used a cell compatible with the version that was created (4.4 or higher). The prototype was developed in conjunction with the Group and Instrumentation Applications Development (GDAI) of the Federal Technological University of Paraná. So this application can be considered an important tool in dietary control, allowing closer control consumption of calcium and dietary proteins.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Forensic speaker comparison exams have complex characteristics, demanding a long time for manual analysis. A method for automatic recognition of vowels, providing feature extraction for acoustic analysis is proposed, aiming to contribute as a support tool in these exams. The proposal is based in formant measurements by LPC (Linear Predictive Coding), selectively by fundamental frequency detection, zero crossing rate, bandwidth and continuity, with the clustering being done by the k-means method. Experiments using samples from three different databases have shown promising results, in which the regions corresponding to five of the Brasilian Portuguese vowels were successfully located, providing visualization of a speaker’s vocal tract behavior, as well as the detection of segments corresponding to target vowels.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only.Methods: A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made.Results: The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures.Conclusions: The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. © 2010 Richter et al; licensee BioMed Central Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2015.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Despite significant progress in the field of tissue engineering within the last decade, a number of unsolved problems still remain. One of the most relevant issues is the lack of proper vascularization that limits the size of engineered tissues to smaller than clinically relevant dimensions. In particular, the growth of engineered tissue in vitro within bioreactors is plagued with this challenge. Specifically, the tubular perfusion system bioreactor has been used for large scale bone constructs; however these engineered constructs lack inherent vasculature and quickly develop a hypoxic core, where no nutrient exchange can occur, thus leading to cell death. Through the use of 3D printed vascular templates in conjunction with a tubular perfusion system bioreactor, we attempt to create an endothelial cell monolayer on 3D scaffolds that could potentially serve as the foundation of inherent vasculature within these engineered bone grafts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Uma das áreas de aplicação da optimização é a Engenharia Biomédica, pois a optimização intervém no estudo de próteses e implantes, na reconstrução tomográfica, na mecânica experimental, entre outras aplicações. Este projecto tem como principal objectivo a criação de um novo programa de marcação de exames médicos a fim de minimizar o tempo de espera na realização dos mesmos. É efectuada uma breve referência à teoria da optimização bem como à optimização linear e não-linear, aos algoritmos genéticos, que foram usados para a realização deste trabalho. É também apresentado um caso de estudo, formulado como um problema de optimização não linear com restrições. Com este estudo verificou-se que o escalonamento de exames médicos nunca poderá ser optimizado a 100por cento devido à quantidade de variáveis existentes, sendo que algumas delas não são passíveis de prever com antecedência.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rapid, sensitive and selective detection of chemical hazards and biological pathogens has shown growing importance in the fields of homeland security, public safety and personal health. In the past two decades, efforts have been focusing on performing point-of-care chemical and biological detections using miniaturized biosensors. These sensors convert target molecule binding events into measurable electrical signals for quantifying target molecule concentration. However, the low receptor density and the use of complex surface chemistry in receptors immobilization on transducers are common bottlenecks in the current biosensor development, adding to the cost, complexity and time. This dissertation presents the development of selective macromolecular Tobacco mosaic virus-like particle (TMV VLP) biosensing receptor, and the microsystem integration of VLPs in microfabricated electrochemical biosensors for rapid and performance-enhanced chemical and biological sensing. Two constructs of VLPs carrying different receptor peptides targeting at 2,4,6-trinitrotoluene (TNT) explosive or anti-FLAG antibody are successfully bioengineered. The VLP-based TNT electrochemical sensor utilizes unique diffusion modulation method enabled by biological binding between target TNT and receptor VLP. The method avoids the influence from any interfering species and environmental background signals, making it extremely suitable for directly quantifying the TNT level in a sample. It is also a rapid method that does not need any sensor surface functionalization process. For antibody sensing, the VLPs carrying both antibody binding peptides and cysteine residues are assembled onto the gold electrodes of an impedance microsensor. With two-phase immunoassays, the VLP-based impedance sensor is able to quantify antibody concentrations down to 9.1 ng/mL. A capillary microfluidics and impedance sensor integrated microsystem is developed to further accelerate the process of VLP assembly on sensors and improve the sensitivity. Open channel capillary micropumps and stop-valves facilitate localized and evaporation-assisted VLP assembly on sensor electrodes within 6 minutes. The VLP-functionalized impedance sensor is capable of label-free sensing of antibodies with the detection limit of 8.8 ng/mL within 5 minutes after sensor functionalization, demonstrating great potential of VLP-based sensors for rapid and on-demand chemical and biological sensing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Microfluidic technologies have great potential to help create automated, cost-effective, portable devices for rapid point of care (POC) diagnostics in diverse patient settings. Unfortunately commercialization is currently constrained by the materials, reagents, and instrumentation required and detection element performance. While most microfluidic studies utilize planar detection elements, this dissertation demonstrates the utility of porous volumetric detection elements to improve detection sensitivity and reduce assay times. Impedemetric immunoassays were performed utilizing silver enhanced gold nanoparticle immunoconjugates (AuIgGs) and porous polymer monolith or silica bead bed detection elements within a thermoplastic microchannel. For a direct assay with 10 µm spaced electrodes the detection limit was 0.13 fM AuIgG with a 3 log dynamic range. The same assay was performed with electrode spacing of 15, 40, and 100 µm with no significant difference between configurations. For a sandwich assay the detection limit was10 ng/mL with a 4 log dynamic range. While most impedemetric assays rely on expensive high resolution electrodes to enhance planar senor performance, this study demonstrates the employment of porous volumetric detection elements to achieve similar performance using lower resolution electrodes and shorter incubation times. Optical immunoassays were performed using porous volumetric capture elements perfused with refractive index matching solutions to limit light scattering and enhance signal. First, fluorescence signal enhancement was demonstrated with a porous polymer monolith within a silica capillary. Next, transmission enhancement of a direct assay was demonstrated by infusing aqueous sucrose solutions through silica bead beds with captured silver enhanced AuIgGs yielding a detection limit of 0.1 ng/mL and a 5 log dynamic range. Finally, ex situ functionalized porous silica monolith segments were integrated into thermoplastic channels for a reflectance based sandwich assay yielding a detection limit of 1 ng/mL and a 5 log dynamic range. The simple techniques for optical signal enhancement and ex situ element integration enable development of sensitive, multiplexed microfluidic sensors. Collectively the demonstrated experiments validate the use of porous volumetric detection elements to enhance impedemetric and optical microfluidic assays. The techniques rely on commercial reagents, materials compatible with manufacturing, and measurement instrumentation adaptable to POC diagnostics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Loading of spinal motion segment units alters biomechanical properties by modifying flexibility and range of motion. This study utilizes angular displacement due to an applied bending moment to assess biomechanical function during high-magnitude and prolonged compressive loading of ovine lumbar motion segments. High compressive loads, representative of physiological lifestyle and occupational behaviors, appear to limit fluid recovery of the intervertebral disc, thereby modifying spinal flexibility and increasing spinal instability. Intermittent extensions, or backwards bending movements, may provide a protective effect against the load-induced spinal instability. This study contributes a greater understanding of the effects of load history on the function and health of the lumbar spine. Findings may inform future efforts investigating adjustments in spinal posture to preserve or promote the recovery of lumbar spinal biomechanics.