964 resultados para Bath interferometer
Resumo:
We discuss the influence of the background thermal bath on the depolarization of electrons in high-energy storage rings, and on the photon emission associated with the spin flip. We focus, in particular, on electrons at CERN LEP. We show that in a certain interval of solid angles the photon emission is enhanced several orders of magnitude because of the presence of the thermal bath. Notwithstanding, the overall depolarization induced by the background thermal bath at LEP conditions is much smaller than the one induced by plain acceleration at zero temperature and can be neglected in practical situations. Eventually we discuss under what conditions the background thermal bath can enhance the overall depolarization by several orders of magnitude.
Resumo:
We investigate whether the equality found for the response of static scalar sources interacting (i) with Hawking radiation in Schwarzschild spacetime and (ii) with the Fulling-Davies-Unruh thermal bath in the Rindler wedge is maintained in the case of electric charges. We find a finite result in the Schwarzschild case, which is computed exactly, in contrast with the divergent result associated with the infrared catastrophe in the Rindler case, i.e., in the case of uniformly accelerated charges in Minkowski spacetime. Thus the equality found for scalar sources does not hold for electric charges.
Resumo:
We show that the response rate of (i) a static source interacting with Hawking radiation of a massless scalar field in Schwarzschild spacetime (with the Unruh vacuum) and that of (ii) a uniformly accelerated source with the same proper acceleration in Minkowski spacetime (with the Minkowski vacuum) are equal. We show that this equality will not hold if the Unruh vacuum is replaced by the Hartle-Hawking vacuum. It is verified that the source responds to the Hawking radiation near the horizon as if it were at rest in a thermal bath in Minkowski spacetime with the same temperature. It is also verified that the response rate in the Hartle-Hawking vacuum approaches that in Minkowski spacetime with the same temperature far away from the black hole. Finally, we compare our results with others in the literature.
Resumo:
The exact solution for the full electronic Hamiltonian for a two-level dimer is obtained. The parameter constellation (roughly 20) is reparametrized via orthogonal Gaussian atomic orbitals, yielding a five-parameter model. With the dimer embedded in a thermal bath, the specific heat and several temperature-dependent dynamical susceptibilities are computed. © 2001 Elsevier Science B.V. All rights reserved.
Resumo:
The present work evaluated the efficacy of mebendazole (MBZ) treatment against infections with the monogenean helminths Anacanthorus penilabiatus, gill parasites of young cultivated pacu, Piaractus mesopotamicus. A short-term bath treatment using 100, 200 and 500 mg MBZ/1 of water for 10 and 30 min and a long-term bath using 1, 10 and 100 mg MBZ/1 of water for 24 h were utilized. Seven days after, fish were sacrificed and parasites counted. Concentrations of 500 and 200 mg MBZ/1 for 10 and 30 min showed reduced efficacy (0.0 and 0.7%) and (14.2 and 11.0%), respectively. Nevertheless, 100 mg MBZ/1 (10 min) and 10 mg MBZ/1 (24 h) showed better efficacy (79.6 and 81.4%, respectively). Treatments for 24 h provoked increases in hematocrit, hemoglobin concentration and leukocyte number when compared to those untreated fish. Mebendazole treatments also provoked alterations in the defense blood cells especially in lymphocyte and thrombocyte numbers, when the fishes were submitted to 10 and 30 min baths.
Resumo:
The Cuphea mesostemon specie, known as sete-sangrias, is widely used as a diuretic substance in popular medicine. As the toad urinary bladder is an epithelium analogous to the distal nephron of mammals, it is used in order to study the transport water and electrolytes in many laboratories. This preparation permits excellent observation in water flow, from the urinary bladder lumen to the external side or the serosal one (water re-absorption), by means of gravimetrical measures. In the present work the hydrosmotic effect of aqueous extract (AE) of sete-sangrias leaf was studied. A 20% solution was added to the serosal side (S) of the bladder preparation, and the water flow was measured every 15 minutes after that. The results showed that 4mL of AE in the S side, increased the JH20 in a significant manner (p<0,05). This effect had a dose - response shape, with the volumes of 0,2mL, 0,4mL and 0,8mL of AE in the S bath. The hydro-osmotic effect of the anti-diuretic hormone (ADH) was studied as well and a significant stimulation (p<0,05) in the JH2O was observed with the magnitude of 150%. The AE effect was similar to the ADH one, and was not antagonized by this hormone. We concluded that Cuphea possesses an anti-diuretic activity similar to that presented by ADH, in toad urinary bladder, in vitro.
Resumo:
This study investigated the effect of different microwave curing cycles on the changes in occlusal vertical dimension of complete dentures. Four test groups with 12 maxillary dentures each were evaluated. Groups 1, 2 and 3 were polymerized with different cycles by microwave radiation and Group 4 was the control and cured by water bath. The average pin opening for all groups was less than 0.5 mm. There was no significant difference between the groups polymerized by the microwave method and the control group. However, analyses of the vertical dimension changes showed statistically significant differences between groups 2 (0.276 +/- 0.141 mm) and 3 (0.496 +/- 0.220 mm).
Resumo:
Statement of problem. Little data are available regarding the effect of heat-treatments on the dimensional stability of hard chairside reline resins. Purpose. The objective of this in vitro study was to evaluate whether a heat-treatment improves the dimensional stability of the reline resin Duraliner II and to compare the linear dimensional changes of this material with the heat-polymerized acrylic resin Lucitone 550. Material and methods. The materials were mixed according to the manufacturer's instructions and packed into a stainless steel split mold (50.0 mm diameter and 0.5 mm thickness) with reference points (A, B, C, and D). Duraliner II specimens were polymerized for 12 minutes in water at 37°C and bench cooled to room temperature before being removed from the mold. Twelve specimens were made and divided into 2 groups: group 1 specimens (n=6) were left untreated, and group 2 specimens (n=6) were submitted to a heat-treatment in a water bath at 55°C for 10 minutes and then bench cooled to room temperature. The 6 Lucitone specimens (control group) were polymerized in a water bath for 9 hours at 71°C. The specimens were removed after the mold reached the room temperature. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold (baseline readings) and on the specimens to the nearest 0.001 mm. Measurements were made after processing and after the specimens had been stored in distilled water at 37°C for 8 different periods of time. Data were subjected to analysis of variance with repeated measures, followed by Tukey's multiple comparison test (P<.05). Results. All specimens exhibited shrinkage after processing (control, -0.41%; group 1, -0.26%; and group 2, -0.51%). Group 1 specimens showed greater shrinkage (-1.23%) than the control (-0.23%) and group 2 (-0.81%) specimens after 60 days of storage in water (P<.05). Conclusion. Within the limitations of this study, a significant improvement of the long-term dimensional stability of the Duraliner II reline resin was observed when the specimens were heat-treated. However, the shrinkage remained considerably higher than the denture base resin Lucitone 550. Copyright © 2002 by The Editorial Council of The Journal of Prosthetic Dentistry.
Resumo:
The effect of bath composition and electroplating conditions on structure, morphology and composition of amorphous Fe-Cr-P-Ni-C deposits on Cu substrate was investigated. The deposition efficiency of Fe-Ni-P-C alloy increased significantly with the addition of formic acid, but decreased with the addition of Cr to the plating bath. The increase of charge density activates the inclusion of Cr in the deposit. However, above a specific value of charge density, which depends on deposition current density, the Cr content in the deposit decreases. SEM analysis showed that the increase of Ni, Cr or charge deposition promotes susceptibility to microcracking.
Resumo:
Fish blood erythrocytes are frequently used as sentinels in biomonitoring studies. Usually, fish blood is collected by painful cardiac or caudal vein punctures. Previous anesthesia could decrease animal suffering but it is not known at present whether anesthesia can cause confounding effects. Therefore, using the alkaline single cell gel (SCG)/comet assay with blood erythrocytes of the cichlid fish Nile tilapia, we tested for a possible modulation of induced DNA damage (methyl methanesulfonate; MMS) by the anesthetic benzocaine administered by bath exposure (80mg/l for ∼10min). Furthermore, benzocaine (80-600mg/l) was tested for its genotoxic potential on fish erythrocytes in vitro and for potential interactions with two known genotoxins (MMS and hydrogen peroxide). Our results did neither indicate a significant increase in the amount of DNA damage (even after a 48h follow-up), nor indicated interactions with MMS-induced DNA damage when fish were exposed to benzocaine in vivo. There was also no increase in DNA damage after in vitro exposure of fish erythrocytes to benzocaine. Clear concentration-related effects were observed for the two genotoxins in vitro, which were not significantly altered by the presence of benzocaine. These results suggest that anesthesia of fish does not confound comet assay results and the use of blood samples from anesthetized fish can be recommended with regard to animal welfare. © 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Studies were carried out to natural papain inhibitor from papaya latex. Fresh latex from green fruits of Carica papaya was collected and immediately transported in ice bath to the lab, from which three fractions with inhibitor effect of esterase papain activity were isolated by latex dialysis, Sephadex G-25 gel filtration and ionic exchange chromatography in SP-Sephadex C-25. The isolated fractions, identified as inhibitors I and II, showed a negative reaction with ninhydrin; however, the fraction identified as P-III showed positive reaction with ninhydrin. Kinetics data showed non-competitive inhibition (inhibitor I) and uncompetitive (inhibitors II and P -III).
Resumo:
This experiment was carried out to evaluate the effects of the stocking density on trairao larvae rearing. Seven days old larvae were submitted to four different stocking densities: 10, 30, 60 and 90 larvae/L. Sixteen vessels with 5 L each supplied with constant aeration were kept in a thermostatic bath. Each treatment had four replications. In order to keep the internal environment dark, all the experimental units were covered with a black plastic and it was uncovered only during the daily management. At the end of the experiment, after 15 days of feeding with Artemia nauplii, no significant differences were found (P>0.05) on growth among the evaluated densities. The same results were also registered for the survival, mortality and cannibalism rates. Higher stocking density resulted in higher production of trairao larvae rearing, allowing intensive rearing of this species in this phase.
Resumo:
Microwave energy has been used as an alternative method for disinfection and sterilization of dental prostheses. This study evaluated the influence of microwave treatment on dimensional accuracy along the posterior palatal border of maxillary acrylic resin denture bases processed by water-bath curing. Thirty maxillary acrylic bases (3-mm-thick) were made on cast models with Clássico acrylic resin using routine technique. After polymerization and cooling, the sets were deflasked and the bases were stored in water for 30 days. Thereafter, the specimens were assigned to 3 groups (n=10), as follows: group I (control) was not submitted to any disinfection cycle; group II was submitted to microwave disinfection for 3 min at 500 W; and in group III microwaving was done for 10 min at 604 W. The acrylic bases were fixed on their respective casts with instant adhesive (Super Bonder®) and the base/cast sets were sectioned transversally in the posterior palatal zone. The existence of gaps between the casts and acrylic bases was assessed using a profile projector at 5 points. No statistically significant differences were observed between the control group and group II. However, group III differed statistically from the others (p<0.05). Treatment in microwave oven at 604 W for 10 min produced the greatest discrepancies in the adaptation of maxillary acrylic resin denture bases to the stone casts.
Resumo:
Piezoelectric actuators are widely used in positioning systems which demand high resolution such as scanning microscopy, fast mirror scanners, vibration cancellation, cell manipulation, etc. In this work a piezoelectric flextensional actuator (PFA), designed with the topology optimization method, is experimentally characterized by the measurement of its nanometric displacements using a Michelson interferometer. Because this detection process is non-linear, adequate techniques must be applied to obtain a linear relationship between an output electrical signal and the induced optical phase shift. Ideally, the bias phase shift in the interferometer should remain constant, but in practice it suffers from fading. The J1-J4 spectral analysis method provides a linear and direct measurement of dynamic phase shift in a no-feedback and no-phase bias optical homodyne interferometer. PFA application such as micromanipulation in biotechnology demands fast and precise movements. So, in order to operate with arbitrary control signals the PFA must have frequency bandwidth of several kHz. However as the natural frequencies of the PFA are low, unwanted dynamics of the structure are often a problem, especially for scanning motion, but also if trajectories have to be followed with high velocities, because of the tracking error phenomenon. So the PFA must be designed in such a manner that the first mechanical resonance occurs far beyond this band. Thus it is important to know all the PFA resonance frequencies. In this work the linearity and frequency response of the PFA are evaluated up to 50 kHz using optical interferometry and the J1-J4 method.
Resumo:
Objective. - To assess the prevalence of stings by small spiny driftwood catfish (carataí) of the genus Centromochlus (Auchenipteridae) accidentally caught in buckets during bucket bathing by riverside people along the Brazilian Amazon and to determine the probability of catching specimens of these fish during random throws of a bucket into the river. Methods. - We interviewed 27 adult residents living at the confluence of the Negro and Solimões rivers in Brazil regarding whether or not they had ever been stung by driftwood catfish while bucket bathing. To assess the likelihood of catching catfish in bathing buckets, we randomly threw a typical plastic bucket used for bathing in 4 series of 10 throws into the river at dusk or night around a floating house. Results. - Seventeen of the 27 subjects (63%) reported being injured by driftwood catfish during bucket bathing. Three individuals (17.6%) had been injured 2 to 3 times, totaling 23 puncture accidents. All stings occurred at dusk or early night. In the 4 series of 10 bucket throws, we caught 3 driftwood catfish (in 1 series we did not catch any fish). Thus, the chance of catching a driftwood catfish in a single bucket throw at dusk was slightly less than 10%. Conclusions. - The prevalence of stings by driftwood catfish to people bucket bathing in this section of the Brazilian Amazon is high, partly because of the relatively high chances of catching these small catfish during random throws of a bathing bucket into the river.