776 resultados para Assessment tool
Resumo:
The use of low-level laser (LLL) may be an useful tool to promote reduction of muscular pain caused by TMD. Aim: This study evaluated the immediate efficacy of low-level laser therapy on women reporting pain and diagnosed with temporomandibular dysfunction (TMD). Methods: Diode laser (GaAlAs) at 790 nm wavelength (infrared spectrum) was applied as experimental treatment. Irradiations of 1.5 J/cm2 were made at 4 points of the temporomandibular joint (TMJ) and of 3 J/cm2 at 3 points in the temporal muscle. An electromyographic (EMG) evaluation of the masseter and anterior temporal was done at the following intervals: before, immediately after, 5 min and 20 min after laser application. Results: Comparison of the electrical activity at the times of measurement revealed a statistically significant difference in masseter muscles before (P=0.025) and immediately after (P=0.013) LLLT. Conclusions: Both masseter and temporal muscles showed a reduction in the measured EMG activities at all times after LLLT, and the temporal muscle showed higher EMG activity than the masseter muscle at all the evaluation times. LLLT caused significant immediate relaxation of the masseter muscles.
Resumo:
Includes bibliography
Specialist tool for monitoring the measurement degradation process of induction active energy meters
Resumo:
This paper presents a methodology and a specialist tool for failure probability analysis of induction type watt-hour meters, considering the main variables related to their measurement degradation processes. The database of the metering park of a distribution company, named Elektro Electricity and Services Co., was used for determining the most relevant variables and to feed the data in the software. The modeling developed to calculate the watt-hour meters probability of failure was implemented in a tool through a user friendly platform, written in Delphi language. Among the main features of this tool are: analysis of probability of failure by risk range; geographical localization of the meters in the metering park, and automatic sampling of induction type watt-hour meters, based on a risk classification expert system, in order to obtain information to aid the management of these meters. The main goals of the specialist tool are following and managing the measurement degradation, maintenance and replacement processes for induction watt-hour meters. © 2011 IEEE.
Resumo:
Background: Ultrasound Doppler is a new technology that has recently been used in large animal reproduction. As the conventional ultrasound (B-mode) it is a noninvasive technique, but with the advantage of allows the assessment of the hemodynamic of reproductive tract in real time. The observation of important features of the vascularization and changes that occur during physiological processes that were not previously seen on B-mode encourage a reassessment of the concepts already established on the events of the reproductive physiology of animals and their applications. Review: In attempt to re-understand the equine reproductive physiology and finding practical uses to this new technique, authors showed that, during the follicular deviation, features are observed by Doppler before being observed under B-mode ultrasound like changes in the speed of the blood flow two days before deviation of the follicle size and one day before the increase in blood flow area of the follicular wall. According to another study ovulation is characterized by a decreased blood flow of the follicular wall in the last four hours preceding it, as well as the serration of the granulosa layer and formation of a non vascularized apex, but in our ongoing study, the ability to decrease the vascularity was not found. Very vascularized follicles are associated with higher rates of oocyte maturation and pregnant that does less vascularized follicles in the preovulatory phase. Those follicles that have septated evacuation (or prolonged) showed more vascularization and serration of the granulosa one hour before ovulation than follicles that ovulate normally, and this vascularization includes the apex of the follicle, the follicular wall portion that is not vascularized in normal ovulation. Another study reported that hemorrhagic follicles have better vascularization of the follicular wall on the days preceding ovulation than follicles destined to ovulate. Some authors also showed that anovulatory follicles grow in size at the same rate as ovulatory follicles, but the percentage of vascularization of its wall is much smaller at 35 mm. Another study characterized that the vascular wall of the follicle that results in the first ovulation of the year is much smaller on the day before ovulation than the number of vessels present in a follicle that will ovulate in the middle of the breeding season. In these cases, the use of Doppler ultrasound can help to prevent economic losses as insemination of mares in cycles that are not able of resulting in pregnancy. This review aims to gather the information found in the literature about the characteristics of follicular hemodynamic of mares taking into account moments of deviation in follicle size, ovulation, ovulation failure and follicular viability. Conclusion: The Doppler technology has the potential to provide important information about the follicular environment and thus be used in practice in search of the perfect equine reproductive management, achieving better utilization of genetic material and increasing the financial return. The use of this new tool opens a large area for several interesting studies that will contribute to the knowledge of the physiological events of the mare for that this technique can soon be effectively applied.
Resumo:
Background: Early trauma care is dependent on subjective assessments and sporadic vital sign assessments. We hypothesized that near-infrared spectroscopy-measured cerebral oxygenation (regional oxygen saturation [rSO 2]) would provide a tool to detect cardiovascular compromise during active hemorrhage. We compared rSO 2 with invasively measured mixed venous oxygen saturation (SvO2), mean arterial pressure (MAP), cardiac output, heart rate, and calculated pulse pressure. Methods: Six propofol-anesthetized instrumented swine were subjected to a fixed-rate hemorrhage until cardiovascular collapse. rSO 2 was monitored with noninvasively measured cerebral oximetry; SvO2 was measured with a fiber optic pulmonary arterial catheter. As an assessment of the time responsiveness of each variable, we recorded minutes from start of the hemorrhage for each variable achieving a 5%, 10%, 15%, and 20% change compared with baseline. Results: Mean time to cardiovascular collapse was 35 minutes ± 11 minutes (54 ± 17% total blood volume). Cerebral rSO 2 began a steady decline at an average MAP of 78 mm Hg ± 17 mm Hg, well above the expected autoregulatory threshold of cerebral blood flow. The 5%, 10%, and 15% decreases in rSO 2 during hemorrhage occurred at a similar times to SvO2, but rSO 2 lagged 6 minutes behind the equivalent percentage decreases in MAP. There was a higher correlation between rSO 2 versus MAP (R =0.72) than SvO2 versus MAP (R =0.55). Conclusions: Near-infrared spectroscopy- measured rSO 2 provided reproducible decreases during hemorrhage that were similar in time course to invasively measured cardiac output and SvO2 but delayed 5 to 9 minutes compared with MAP and pulse pressure. rSO 2 may provide an earlier warning of worsening hemorrhagic shock for prompt interventions in patients with trauma when continuous arterial BP measurements are unavailable. © 2012 Lippincott Williams & Wilkins.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The Caribbean region remains highly vulnerable to the impacts of climate change. In order to assess the social and economic consequences of climate change for the region, the Economic Commission for Latin America and the Caribbean( ECLAC) has developed a model for this purpose. The model is referred to as the Climate Impact Assessment Model (ECLAC-CIAM) and is a tool that can simultaneously assess multiple sectoral climate impacts specific to the Caribbean as a whole and for individual countries. To achieve this goal, an Integrated Assessment Model (IAM) with a Computable General Equilibrium Core was developed comprising of three modules to be executed sequentially. The first of these modules defines the type and magnitude of economic shocks on the basis of a climate change scenario, the second module is a global Computable General Equilibrium model with a special regional and industrial classification and the third module processes the output of the CGE model to get more disaggregated results. The model has the potential to produce several economic estimates but the current default results include percentage change in real national income for individual Caribbean states which provides a simple measure of welfare impacts. With some modifications, the model can also be used to consider the effects of single sectoral shocks such as (Land, Labour, Capital and Tourism) on the percentage change in real national income. Ultimately, the model is envisioned as an evolving tool for assessing the impact of climate change in the Caribbean and as a guide to policy responses with respect to adaptation strategies.
Resumo:
Pós-graduação em Fonoaudiologia - FFC
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Developmental Coordination Disorder (DCD), a chronic and usually permanent condition found in children, is characterized by motor impairment that interferes with a child's activities of daily living and with academic achievement. One of the most popular tests for the quantitative diagnosis of DCD is the Movement Assessment Battery for Children (MABC). Based on the Battery's standardized scores, it is possible to identify children with typical development, children at risk of developing DCD, and children with DCD. This article describes a computational system we developed to assist with the analysis of results obtained in the MABC test. The tool was developed for the web environment and its database provides integration of MABC data. Thus, researchers around the world can share data and develop collaborative work in the DCD field. In order to help analysis processes, our system provides services for filtering data to show more specific sets of information and present the results in textual, table, and graphic formats, allowing easier and more comprehensive evaluation of the results.
Resumo:
Translation, cross-cultural adaptation and validation of the DYMUS questionnaire for the assessment of dysphagia in multiple sclerosis. The original English version of the DYMUS was translated using the forward-backward technique, cross-culturally adaptated, pilot-tested in 40 patients, and then applied to 100 multiple sclerosis patients to assess the reliability and construct validity. Construct validity was assessed by Mann–Whitney test and Spearman’s correlation coefficient (rs). The internal consistency of the questionnaire was evaluated using Cronbach’s alpha coefficient and inter-item correlation. DYMUS-BR internal consistency was high (Cronbach’s alpha= 0.72); Cronbach’s alpha was 0.65 for the ‘dysphagia for solids’ subscale and 0.67 for the ‘dysphagia for liquids’ subscale and positive inter-item correlations was found between all items, except for weight loss question. Significant association (p<0.001) and correlation (rs = 0,357; p = 0.01) was found between DYMUS-BR and dysphagia self-assessment. The DYMUS-BR questionnaire maintained the characteristics of that originally described, demonstrating to be a reliable, valid, easy and consistent tool to be used by health professionals for preliminary selection of Brazilian MS patients who need more specific instrumental analyses of swallowing.
Resumo:
The aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
High-frequency ultrasound is a non-invasive tool used in skin ageing research to assess dermis thickness and echogenicity. This study evaluated the reliability of a range of high-frequency ultrasound parameters and tested their correlation with age and a validated clinical scale for the assessment of forearm skin photoageing; the difference between two body sites according to environmental exposition patterns was also investigated. Twenty-three volunteers aged 28-82 years were divided into three groups according to forearm photoageing degree. A 20 MHz ultrasound unit was used to obtain cross-sectional images of the skin by two trained investigators on two different sites: the dorsal forearm (chronically photoexposed skin) and the proximal medial arm (non-photoexposed skin). Several echogenicity parameters were studied for each skin compartment: total dermis, upper dermis and lower dermis, and the ratio between upper and lower dermis. The intraclass correlation coefficient (for complete agreement) between investigators was higher for upper and total dermis echogenicity measures compared with the lower dermis. At the non-photoexposed site, the upper and lower dermis parameter ratio was better correlated with age. At the photoexposed area, total dermis parameters demonstrated higher correlations with clinical score. The authors discuss the choice of parameters for forearm photoageing assessment using high-frequency ultrasound.
Resumo:
This paper deals with transient stability analysis based on time domain simulation on vector processing. This approach requires the solution of a set of differential equations in conjunction of another set of algebraic equations. The solution of the algebraic equations has presented a scalar as sequential set of tasks, and the solution of these equations, on vector computers, has required much more investigations to speedup the simulations. Therefore, the main objective of this paper has been to present methods to solve the algebraic equations using vector processing. The results, using a GRAY computer, have shown that on-line transient stability assessment is feasible.