720 resultados para Aparelhos ortodônticos removíveis
Resumo:
Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ?3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.
Resumo:
Introduction: The aim of this prospective clinical study was to investigate the cephalometric changes produced by bonded spurs associated with high-pull chincup therapy in children with Angle Class I malocclusion and anterior open bite. Methods: Thirty patients with an initial mean age of 8.14 years and a mean anterior open bite of 3.93 mm were treated with bonded spurs associated with chincup therapy for 12 months. An untreated control group of 30 subjects with an initial mean age of 8.36 years and a mean anterior open bite of 3.93 mm and the same malocclusion was followed for 12 months for comparison. Student t tests were used for intergroup comparisons. Results: The treated group demonstrated a significantly greater decrease of the gonial angle, and increase in overbite, palatal tipping of the maxillary incisors, and vertical dentoalveolar development of the maxillary and mandibular incisors compared with the control group. Conclusions: The association of bonded spurs with high-pull chincup therapy was efficient for the correction of the open bite in 86.7% of the patients, with a 5.23-mm (SD, 61.69) overbite increase.
Resumo:
Bone remodeling is affected by mechanical loading and inflammatory mediators, including chemokines. The chemokine (C–C motif) ligand 3 (CCL3) is involved in bone remodeling by binding to C–C chemokine receptors 1 and 5 (CCR1 and CCR5) expressed on osteoclasts and osteoblasts. Our group has previously demonstrated that CCR5 down-regulates mechanical loading-induced bone resorption. Thus, the present study aimed to investigate the role of CCR1 and CCL3 in bone remodeling induced by mechanical loading during orthodontic tooth movement in mice. Our results showed that bone remodeling was significantly decreased in CCL3−/− and CCR1−/− mice and in animals treated with Met-RANTES (an antagonist of CCR5 and CCR1). mRNA levels of receptor activator of nuclear factor kappa-B (RANK), its ligand RANKL, tumor necrosis factor alpha (TNF-α) and RANKL/osteoprotegerin (OPG) ratio were diminished in the periodontium of CCL3−/− mice and in the group treated with Met-RANTES. Met-RANTES treatment also reduced the levels of cathepsin K and metalloproteinase 13 (MMP13). The expression of the osteoblast markers runt-related transcription factor 2 (RUNX2) and periostin was decreased, while osteocalcin (OCN) was augmented in CCL3−/− and Met-RANTES-treated mice. Altogether, these findings show that CCR1 is pivotal for bone remodeling induced by mechanical loading during orthodontic tooth movement and these actions depend, at least in part, on CCL3.
Resumo:
Este trabalho apresenta os resultados iniciais de uma pesquisa, descrevendo o comportamento de usuários de edifícios de escritórios em relação às temperaturas de acionamento de ventiladores e aparelhos condicionadores de ar. Medições foram realizadas em quatro salas administrativas do Instituto de Arquitetura e Urbanismo de São Carlos – IAU/USP, nas quais foram registradas as temperaturas internas do ar e o momento de acionamento dos referidos equipamentos. Os valores registrados foram comparados à temperatura externa e à faixa de temperaturas de conforto descrita pela norma ASHRAE 55/2004. As temperaturas registradas de acionamento dos aparelhos condicionadores de ar e ventiladores são similares e estão dentro da faixa considerada confortável pela referida norma.
Resumo:
Considerando a indisponibilidade de equipamentos avançados de aquisição de imagens nos centros cirúrgicos da maioria dos centros hospitalares e a importância fundamental que têm para o cirurgião uma visualização imediata do implante coclear logo após sua inserção, uma boa opção é a utilização da radiografia convencional. OBJETIVO: Descrever um método radiográfico rápido prático e de baixo custo, que permita avaliar não só a posição, mas também a integridade dos eletrodos, na instalação do implante coclear. MATERIAL E MÉTODO: Foram analisadas radiografias de 262 pacientes submetidos à cirurgia de implante coclear entre Março/2005 e Outubro/2008, com radiografia transoperatória, logo após a inserção dos eletrodos. As radiografias foram analisadas pelo cirurgião no transoperatório e, posteriormente, pelo médico radiologista. RESULTADOS: Foram analisadas 524 radiografias das quais, 95,61% apresentavam técnica adequada, com posicionamento do paciente dentro da técnica descrita neste estudo e boa visualização dos eletrodos, sendo consideradas satisfatórias e 4,39% apresentavam técnica inadequada e/ou visualização insatisfatória dos eletrodos, sendo consideradas insatisfatórias. CONCLUSÃO: Apesar dos aparelhos de Raios X portáteis possuírem limitações, utilizando técnicas e acessórios adequados, é possível conseguir radiografias com resultados satisfatórios para visualização dos implantes cocleares.
Resumo:
Devido aos avanços na tecnologia dos implantes cocleares e das estratégias de processamento, indivíduos com surdez grave a profunda puderam ouvir sons e reconhecer fala em diferentes graus. A variabilidade nos resultados audiológicos em portadores de surdez pós-lingual tem sido grande e a indicação para o implante coclear tem se estendido e inclui uma população cada vez maior. OBJETIVO: Avaliar em quais pacientes portadores de surdez pós-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. MATERIAIS E MÉTODOS: consulta a artigos científicos por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Foram selecionadas publicações com força de evidência A ou B até a data da investigação, que comparassem aparelhos de amplificação sonora e implante coclear na população com surdez pós-lingual. Desenho do Estudo: revisão sistemática. RESULTADOS: Entre os 2169 artigos consultados, 11 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Seis estudos são do tipo coorte prospectivo, quatro são estudos transversais e um ensaio clinico. CONCLUSÃO: A avaliação dos benefícios obtidos por portadores de surdez pós-lingual reabilitados com o uso de implante coclear mostra que este dispositivo é efetivo e apresenta melhores resultados quando comparado aos aparelhos de amplificação sonora individual.
Resumo:
INTRODUÇÃO: O governo brasileiro atualmente credencia cerca de 140 centros especializados para adaptações de aparelhos de amplificação sonora individual via SUS. Adaptações à distância através da internet podem permitir maior eficiência na prestação deste serviço e com maiores chances de aceitação por parte do paciente do SUS. OBJETIVOS: Descrever o caso de adaptação à distância realizado entre duas cidades, com revisão da literatura. MÉTODO: Equipamentos de informática e de tecnologia da informação, programador universal, aparelhos de amplificação sonora individual. ESTUDO DE CASO: Uma fonoaudióloga lotada num centro especializado introduziu a um centro remoto (distância de 200 km) um novo aparelho de amplificação sonora individual e seu programa de adaptação. O centro remoto assistiu a adaptação de dois pacientes em sua clínica, realizando voluntariamente a adaptação do terceiro paciente. Todo o procedimento foi realizado através da internet, contando com recursos de áudio e vídeo em todos os procedimentos. RESULTADOS: Três pacientes foram adaptados à distância. Três fonoaudiólogas receberam treinamento à distância de como adaptar aparelhos auditivos. CONCLUSÃO: Foi possível adaptar AASI à distância, além de prover treinamento e habilitar um centro remoto na adaptação de um novo aparelho de amplificação sonora individual e de seu programa de adaptação. Tal procedimento pode ser útil ao governo na condução de políticas públicas da saúde auditiva.
Resumo:
INTRODUÇÃO: A maioria dos pacientes com perda auditiva, incluindo casos de perdas severas, é beneficiada com o uso de aparelho de amplificação sonora individual. Acredita-se que o implante coclear estabeleça melhores resultados na reabilitação de uma criança com perda auditiva nos casos em que a gravidade da deficiência torna os aparelhos acústicos convencionais incapazes de fornecer informação sonora adequada, já que estes necessitam de reserva coclear suficiente para que ocorra detecção acústica. OBJETIVO: Avaliar se em pacientes portadores de surdez pré-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. SÍNTESE DOS DADOS: Revisão sistemática realizada a partir de consulta a artigos científicos selecionados por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Entre os 2169 artigos consultados, 12 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Entre os desenhos de estudos analisados na revisão, 7 são do tipo coorte prospectivo e 5 são estudos transversais. CONCLUSÃO: O implante coclear demonstrou, através de diversos estudos, ser atualmente, a melhor alternativa para os casos de perdas auditivas bilaterais severas ou profundas, atingindo resultados superiores em percepção e desenvolvimento de fala em crianças pré-linguais quando comparados aos aparelhos de amplificação sonora convencionais.
Resumo:
OBJECTIVE: This study aimed to evaluate the cephalometric effects promoted by the orthodontic treatment of Class II malocclusion patients with the use of the 10-Hour Force Theory, that consists in the use of fixed appliances with 8 hours a day using a cervical headgear appliance and 16 hours a day using Class II elastics, 8 hours on the first mandibular molar and 8 hours in the second mandibular molar. METHODS: Sample comprised 31 patients with mean initial age of 14.90 years, final mean age of 17.25 years and mean treatment time of 2.35 years. The lateral cephalograms in pre-treatment and post-treatment stages were evaluated. Evaluation of cephalometric changes between initial and final treatment phases was performed by paired t test. RESULTS: The cases treated with the 10-Hour Force Theory presented a slight restriction of anterior displacement of the maxilla, increase in the effective length of the mandible, significant improvement of the maxillomandibular relationship, significant increase in anterior lower face height, distal tipping of the maxillary premolar crowns, extrusion and distal tipping of the roots of maxillary molars, significant proclination and protrusion of mandibular incisors, significant extrusion and mesialization of mandibular molars, besides a significant correction of the molar relationship, overjet and overbite. CONCLUSION: The use of the 10-Hour Force Theory in treatment of Class II malocclusion provided satisfactory results.
Resumo:
Introdução: Trombose Venosa Profunda (TVP) é o resultado de inúmeros fatores, incluindo estase venosa, injuria endotelial e hipercoagulação do sangue. O embolismo pulmonar é a maior complicação da TVP e ocorre quando um trombo ou um coágulo sangüíneo desloca-se em direção aos pulmões. O tromboembolismo é um sério problema de saúde e é responsável por um considerável número de mortes súbitas e por significantes custos de hospitalizações em todo o mundo. Entre os métodos profiláticos usados na prevenção da TVP, há os classificados como mecânicos e os farmacológicos. Ambos são efetivos e podem ser usados sempre que necessário, tendo sido recomendados por consenso internacional. Objetivos: Avaliar a incidência da TVP em pacientes cirúrgicos através da Compressão pneumática Intermitente CPI (coxa/perna ou perna/pé) contra nenhuma forma de profilaxia ou contra fármacos. Métodos: Revisão sistemática de ensaios clínicos randomizados, utilizando a metodologia Cochrane, através de buscas eletrônica e manual. Foram incluídos pacientes cirúrgicos, de ambos os sexos, cuja intervenção foi o uso de aparelhos de compressão pneumática intermitente. Resultados: 4269 pacientes cirúrgicos investigados por 31 ensaios submetidos a um número de intervenções cirúrgicas, incluindo cirurgia ortopédica (joelho e quadris), geral, ginecológica, urológica e neurológica. Dados combinados demonstraram efeitos de tratamento virtualmente iguais entre CPI e abordagens farmacológicas [0.95 (95%CI 0.82, 1.10)], em relação à incidência de TVP. Entretanto, o risco de hemorragia foi maior e estatisticamente significante em pacientes tratados com intervenções farmacológicas [0.37(95%CI 0.20, 0.69)]. Conclusão: Comparações entre as estratégias farmacológicas e mecânicas indicam que ambas são similares na prevenção de trombose venosa profunda. Entretantio, a evidência atual suportaria a escolha das abordagens mecâncias, uma vez que o risco de eventos hemorrágicos favorece os métodos mecânicos.
Resumo:
A preocupação com o estudo das formas e dimensões das arcadas dentárias sempre esteve presente na ciência ortodôntica. Para a Ortodontia Lingual, que surgiu no final da década de 70, o primeiro artigo publicado foi o Fujita, onde relatou sobre a forma do arco a ser utilizado nesta técnica, a forma de cogumelo. Apesar de estar sendo divulgada de uma maneira mais intensa nestes últimos anos como uma solução estética definitiva e eficaz, o enfoque dos estudos sobre esta técnica tem sido a fabricação de novos materiais, técnicas de montagem do aparelho lingual e soluções clínicas, com poucas menções sobre a morfologia das arcadas dentárias. O presente trabalho tem a finalidade de estudar as formas e dimensões linguais das arcadas dentárias de indivíduos leucodermas com oclusão normal. Foram utilizados 47 pares de modelos de gesso de oclusão normal digitalizados pela face olcusal, previamente desgastadas até o terço médio da coroa para proporcionar melhor visualização. Por meio do programa CorelDraw 12 foram determinados pontos de referências e criados alguns pontos virtuais necessários para a realização das medidas. Os resultados determinaram três formas das arcadas dentárias linguais: cogumelo, árvore de Natal e mista. A maior prevalência foi a forma árvore de Natal, mas quando analisadas separadamente as arcadas dentárias linguais, encontrados no superior, maior prevalência da forma de cogumelo e no inferior da forma árvore de Natal. Conseqüentemente, esta foi a combinação mais prevalente entre as arcadas dentárias linguais superiores e inferiores. Propusemos diagramas para conformação de arcos ortodônticos linguais com base nos valores obtidos da amostra, determinando-se o quartil 1, mediana e quartil 3, como definidores dos tamanhos pequeno, médio e grande.
Resumo:
A preocupação com o estudo das formas e dimensões das arcadas dentárias sempre esteve presente na ciência ortodôntica. Para a Ortodontia Lingual, que surgiu no final da década de 70, o primeiro artigo publicado foi o Fujita, onde relatou sobre a forma do arco a ser utilizado nesta técnica, a forma de cogumelo. Apesar de estar sendo divulgada de uma maneira mais intensa nestes últimos anos como uma solução estética definitiva e eficaz, o enfoque dos estudos sobre esta técnica tem sido a fabricação de novos materiais, técnicas de montagem do aparelho lingual e soluções clínicas, com poucas menções sobre a morfologia das arcadas dentárias. O presente trabalho tem a finalidade de estudar as formas e dimensões linguais das arcadas dentárias de indivíduos leucodermas com oclusão normal. Foram utilizados 47 pares de modelos de gesso de oclusão normal digitalizados pela face olcusal, previamente desgastadas até o terço médio da coroa para proporcionar melhor visualização. Por meio do programa CorelDraw 12 foram determinados pontos de referências e criados alguns pontos virtuais necessários para a realização das medidas. Os resultados determinaram três formas das arcadas dentárias linguais: cogumelo, árvore de Natal e mista. A maior prevalência foi a forma árvore de Natal, mas quando analisadas separadamente as arcadas dentárias linguais, encontrados no superior, maior prevalência da forma de cogumelo e no inferior da forma árvore de Natal. Conseqüentemente, esta foi a combinação mais prevalente entre as arcadas dentárias linguais superiores e inferiores. Propusemos diagramas para conformação de arcos ortodônticos linguais com base nos valores obtidos da amostra, determinando-se o quartil 1, mediana e quartil 3, como definidores dos tamanhos pequeno, médio e grande.
Resumo:
O atrito existente entre bráquetes e os fios ortodônticos é um fator importante a ser considerado quanto à eficiência do tratamento ortodôntico nas mecânicas de deslize. Em função disto, sempre se procurou maneiras de se diminuir os níveis de atrito durante a aplicação deste tipo de mecânica. Com o surgimento dos bráquetes autoligados, observou-se que uma das características principais destes dispositivos seria uma redução dos níveis de atrito entre os bráquetes e fios, e com isso poderia se obter um movimento de deslizamento eficiente com a aplicação de forças menores, quando comparado com o uso de bráquetes que tenham sistemas de amarração convencionais. O propósito deste trabalho foi comparar, por meio de ensaios laboratoriais, os níveis de atrito estático de um bráquete autoligado estético, de um bráquete autoligado metálico e dois tipos de bráquetes convencionais metálicos, com a utilização de fios ortodônticos de diferentes ligas, secção e diâmetros, para determinar quais bráquetes apresentam os menores coeficientes de atrito, em situações sem angulação, em angulações de primeira ordem e angulações de segunda ordem entre os diferentes fios e bráquetes. Os resultados demonstraram que os bráquetes autoligados apresentaram um atrito estático significativamente mais baixo nas situações onde não existiu angulação entre o fio e o bráquete e quando se utilizou fios de calibres menores e com material mais flexível, quando comparados com os bráquetes convencionais. O bráquete autoligado metálico apresentou maior atrito, semelhante aos bráquetes convencionais, com o uso dos fios de maior calibre, nas situações sem angulação. O bráquete autoligado metálico apresentou maior atrito estático que os bráquetes convencionais, nas situações de angulação, com o uso dos fios de maior calibre
Resumo:
O atrito existente entre bráquetes e os fios ortodônticos é um fator importante a ser considerado quanto à eficiência do tratamento ortodôntico nas mecânicas de deslize. Em função disto, sempre se procurou maneiras de se diminuir os níveis de atrito durante a aplicação deste tipo de mecânica. Com o surgimento dos bráquetes autoligados, observou-se que uma das características principais destes dispositivos seria uma redução dos níveis de atrito entre os bráquetes e fios, e com isso poderia se obter um movimento de deslizamento eficiente com a aplicação de forças menores, quando comparado com o uso de bráquetes que tenham sistemas de amarração convencionais. O propósito deste trabalho foi comparar, por meio de ensaios laboratoriais, os níveis de atrito estático de um bráquete autoligado estético, de um bráquete autoligado metálico e dois tipos de bráquetes convencionais metálicos, com a utilização de fios ortodônticos de diferentes ligas, secção e diâmetros, para determinar quais bráquetes apresentam os menores coeficientes de atrito, em situações sem angulação, em angulações de primeira ordem e angulações de segunda ordem entre os diferentes fios e bráquetes. Os resultados demonstraram que os bráquetes autoligados apresentaram um atrito estático significativamente mais baixo nas situações onde não existiu angulação entre o fio e o bráquete e quando se utilizou fios de calibres menores e com material mais flexível, quando comparados com os bráquetes convencionais. O bráquete autoligado metálico apresentou maior atrito, semelhante aos bráquetes convencionais, com o uso dos fios de maior calibre, nas situações sem angulação. O bráquete autoligado metálico apresentou maior atrito estático que os bráquetes convencionais, nas situações de angulação, com o uso dos fios de maior calibre
Resumo:
O objetivo deste estudo foi comparar cefalometricamente os efeitos dentários promovidos pelo aparelho extrabucal e com a placa lábio-ativa, instalados para a contenção dos molares superiores distalizados previamente com a placa de Cetlin associada ao aparelho extrabucal. A amostra consistiu de 40 telerradiografias em norma lateral, obtidas de 20 pacientes, sendo 6 do sexo masculino e 14 do sexo feminino, com idade média de 11 anos e 7 meses, tratados por um período médio de 14 meses e 10 dias. Após a distalização, que foi feita com a placa de Cetlin associada ao aparelho extrabucal cérvico-occipital, estes pacientes foram divididos aleatoriamente em dois grupos, onde o grupo AEB utilizou o próprio aparelho extrabucal de uso noturno e o grupo PLA utilizou uma placa lábio-ativa superior em período integral, ambos os aparelhos para conter os primeiros molares superiores distalizados durante a fase de alinhamento e nivelamento dentários. Após a análise estatística, verificou-se que no grupo AEB os molares superiores apresentaram apenas uma inclinação para mesial em média de 8,220 . Já os incisivos superiores inclinaram para lingual, em média, 3,330. No grupo PLA, os molares apresentaram extrusão de, em média, 1,82 mm; mesialização de 3,14 mm; e inclinação para mesial de 8,320; já os incisivos inclinaram para lingual 5,780, em média. Ao comparar os resultados dos grupos entre si, verificou-se que não houve diferença estatisticamente significante entre os aparelhos utilizados. Portanto, tanto o aparelho extrabucal, como a placa lábio-ativa apresentaram-se eficazes para a contenção dos molares superiores distalizados durante as fases de alinhamento e nivelamento dentários.