960 resultados para Angular distortion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The following study aims to examine a controversial and relatively unexplored subject within our system: the legal framework on unfair business-to-consumer commercial practices. Given the fact that this subject is based on the Directive 2005/29/EC, we considered to be appropriate to explore, firstly, the background and origin of such normative instrument. Nevertheless, we have centered our analysis on the interpretation of the set rules established by the Portuguese legal system (Law nr 57/2008, March 26th). For this dissertation, we have proposed a model of tripartite approach. Chapter V seeks to shed light on the general clause by analyzing a set of open concepts such as professional diligence, honest market practice, good faith or material distortion of the consumer’s economic behavior. In chapter VI, we will focus on two common types of unfair commercial practices: misleading and aggressive practices. Finally, due to the fact that chapter VII deals with the black list, we have illustrated the listed practices by giving real life examples. Taking into account the indefinite concepts used in the general prohibition and in the misleading and aggressive clauses, it is particularly difficult to demonstrate the unfairness of the professional’s behavior. In the light of this information, we have concluded that the regime fails on achieving its main goal: it does not protect proper and effectively the consumer’s interests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When assessing investment options, investors focus on the graphs of annual reports, despite lack of auditing. If poorly constructed, graphs distort perceptions and lead to inaccurate decisions. This study examines graph usage in all the companies listed on Euronext Lisbon in 2013. The findings suggest that graphs are common in the annual reports of Portuguese companies and that, while there is no evidence of Selectivity Distortion, both Measurement and Orientation Distortions are pervasive. The study recommends the auditing of financial graphs, and urges preparers and users of annual reports to be wary of the possibility of graph distortion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to assess the flexor-extensor group of muscles of the knee in young athletes diagnosed with a total rupture of the anterior cruciate ligament (ACL). Eighteen knees of 18 athletes (14 men and 4 women) with an average age of 21.6 years (range 16-32 years) were assessed with a Cybex 6000 model isokinetic apparatus. The average interval between occurrence of the injury and assessment was 10.2 months (range 2 - 48 months). There was an associated meniscal injury in eight of the knees. Athletes with any other kind of associated injury, limitation, or blockage of the movement of the joint, significant pain during the exam, or interval between injury and exam of less than two months were excluded from the study. The parameters studied were the peak torque-velocity and flexor-extensor relationships at the constant angular velocities of 60°/sec and 240°/sec. Previous warming-up was done by means of an ergometric bicycle and adaptation with 3 submaximal repetitions. The contra-lateral side, which presented no injury, was used as control. Peak torque (PT) at the constant velocity of 60°/sec was greater than that at 240°/sec for knees with and without injuries. However, there was no significant difference between the injured and uninjured sides at 60°/sec or at 240°/sec. The average value for the flexor-extensor relationship at 60°/sec on the injured was 60% (( 6), compared to 57% (( 10) on the contra-lateral side. At 240°/sec, the average value was 75% ((10) on the injured side, and 65% ((12) on the contra-lateral side. In conclusion, despite the complete rupture of the ACL of one knee, the average values for the flexor-extensor relationship were similar on the injured and uninjured sides at the velocity of 60°/sec. As the velocity increased, an increase in the values for the flexor-extensor relationship of the knee also occurred, indicating a tendency of the performance of the flexor muscle group to approach that of the extensor muscle group, and this tendency was more pronounced on the side of the injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modern fully integrated transceivers architectures, require circuits with low area, low cost, low power, and high efficiency. A key block in modern transceivers is the power amplifier, which is deeply studied in this thesis. First, we study the implementation of a classical Class-A amplifier, describing the basic operation of an RF power amplifier, and analysing the influence of the real models of the reactive components in its operation. Secondly, the Class-E amplifier is deeply studied. The different types of implementations are reviewed and theoretical equations are derived and compared with simulations. There were selected four modes of operation for the Class-E amplifier, in order to perform the implementation of the output stage, and the subsequent comparison of results. This led to the selection of the mode with the best trade-off between efficiency and harmonics distortion, lower power consumption and higher output power. The optimal choice was a parallel circuit containing an inductor with a finite value. To complete the implementation of the PA in switching mode, a driver was implemented. The final block (output stage together with the driver) got 20 % total efficiency (PAE) transmitting 8 dBm output power to a 50 W load with a total harmonic distortion (THD) of 3 % and a total consumption of 28 mW. All implementations are designed using standard 130 nm CMOS technology. The operating frequency is 2.4 GHz and it was considered an 1.2 V DC power supply. The proposed circuit is intended to be used in a Bluetooth transmitter, however, it has a wider range of applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess knee flexor-extensor muscular strength in elderly women with no previous history of musculoskeletal disorders on the lower limbs using an isokinetic dynamometer, in order to obtain data that could be used as a comparative parameter in the evaluation of elderly women with knee disorders, thus facilitating a better rehabilitation of these patients. METHODS: Twenty-six volunteers aged 75 to 83 years were studied using a Cybex® 6000 isokinetic dynamometer. The chosen angular velocity was 60 º/s, and concentric exercise was used for either flexion or extension. The studied parameters were: peak torque, angle of peak torque, and flexor-extensor torque rate. RESULTS: There were no differences between dominant (D) and nondominant (ND) knee peak torque values. This was true for both flexor (D = 42.46 ± 9.09 Nm / ND = 40.65 ± 9.38 Nm) and extensor (D = 76.92 ± 13.97 Nm / ND = 77.65 ± 15.21 Nm) movements. The descriptive statistical analysis of the values obtained for the flexor-extensor peak torque rate and for the angle of occurrence of peak torque was the same for the dominant and nondominant sides. CONCLUSIONS: The values of peak torque for the contralateral side can be used as a reference during rehabilitation of elderly women with acute disease of the knee, and the angular velocity of 60 º/s is proper and safe for isokinetic assessment of elderly people.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A existência de um Efeito Electroreológico (ER) constata-se quando se verifica uma variação acentuada das propriedades reológicas induzidas pelas presença de um campo electrico numa amostra. Este fenómeno é tipico mas não exclusivamente observado em suspensões de particulas polarizáveis. Neste trabalho levou-se a cabo o estudo do efeito electroreológico de uma suspensão, em óleo de silicone, de nanofibras de polianilina (PANI) dopadas com ácido canforsulfónico (CSA). Foram preparadas soluções poliméricas com diferentes concentrações de nanofibras (1 e 2 % p/p) em dois óleos de silicone de diferentes viscosidades, 20 e 50 cSt. O estudo das propriedades electroreológicas foi efectuado tanto em regime estacionário, com a taxa de corte a variar entre 0.01 e 1000 s-1, como em regime oscilatório, com a frequência angular a variar entre 0.1 e 20 Hz, ambos na presença de campos eléctricos com intensidades até 2kV.mm-1 e à temperatura ambiente. As suspensões de nanofibras de polianilina dopadas com ácido canforsulfónico dispersas em óleo de silicone apresentam um efeito electroreológico intenso, visivel através de um aumento superior a 2 décadas no valor da viscosidade para baixas taxas de corte e valores elevados de campo eléctrico, demonstrando assim a sua potencialidade como material inteligente .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modern fully integrated receiver architectures, require inductorless circuits to achieve their potential low area, low cost, and low power. The low noise amplifier (LNA), which is a key block in such receivers, is investigated in this thesis. LNAs can be either narrowband or wideband. Narrowband LNAs use inductors and have very low noise figure, but they occupy a large area and require a technology with RF options to obtain inductors with high Q. Recently, wideband LNAs with noise and distortion cancelling, with passive loads have been proposed, which can have low NF, but have high power consumption. In this thesis the main goal is to obtain a very low area, low power, and low-cost wideband LNA. First, it is investigated a balun LNA with noise and distortion cancelling with active loads to boost the gain and reduce the noise figure (NF). The circuit is based on a conventional balun LNA with noise and distortion cancellation, using the combination of a common-gate (CG) stage and common-source (CS) stage. Simulation and measurements results, with a 130 nm CMOS technology, show that the gain is enhanced by about 3 dB and the NF is reduced by at least 0.5 dB, with a negligible impact on the circuit linearity (IIP3 is about 0 dBm). The total power dissipation is only 4.8 mW, and the active area is less than 50 x 50 m2 . It is also investigated a balun LNA in which the gain is boosted by using a double feedback structure.We propose to replace the load resistors by active loads, which can be used to implement local feedback loops (in the CG and CS stages). This will boost the gain and reduce the noise figure (NF). Simulation results, with the same 130 nm CMOS technology as above, show that the gain is 24 dB and NF is less than 2.7 dB. The total power dissipation is only 5.4 mW (since no extra blocks are required), leading to a figure-of-merit (FoM) of 3.8 mW

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the effects of 2 different doses of exogenous surfactant on pulmonary mechanics and on the regularity of pulmonary parenchyma inflation in newborn rabbits. METHOD: Newborn rabbits were submitted to tracheostomy and randomized into 4 study groups: the Control group did not receive any material inside the trachea; the MEC group was instilled with meconium, without surfactant treatment; the S100 and S200 groups were instilled with meconium and were treated with 100 and 200 mg/kg of exogenous surfactant (produced by Instituto Butantan) respectively. Animals from the 4 groups were mechanically ventilated during a 25-minute period. Dynamic compliance, ventilatory pressure, tidal volume, and maximum lung volume (P-V curve) were evaluated. Histological analysis was conducted using the mean linear intercept (Lm), and the lung tissue distortion index (SDI) was derived from the standard deviation of the means of the Lm. One-way analysis of variance was used with a = 0.05. RESULTS: After 25 minutes of ventilation, dynamic compliance (mL/cm H2O · kg) was 0.87 ± 0.07 (Control); 0.49 ± 0.04 (MEC*); 0.67 ± 0.06 (S100); and 0.67 ± 0.08 (S200), and ventilatory pressure (cm H2O) was 9.0 ± 0.9 (Control); 16.5 ± 1.7 (MEC*); 12.4 ± 1.1 (S100); and 12.1 ± 1.5 (S200). Both treated groups had lower Lm values and more homogeneity in the lung parenchyma compared to the MEC group: SDI = 7.5 ± 1.9 (Control); 11.3 ± 2.5 (MEC*), 5.8 ± 1.9 (S100); and 6.7 ± 1.7 (S200) (*P < 0.05 versus all the other groups). CONCLUSIONS: Animals treated with surfactant showed significant improvement in pulmonary mechanics and more regularity of the lung parenchyma in comparison to untreated animals. There was no difference in results after treatment with either of the doses used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The global and increasingly technological society requires the States to adopt security measures that can maintain the balance between the freedom, on the one hand, and the security and the respect for fundamental rights of a democratic state, on the other. A State can only achieve this aim if it has an effective judicial system and in particular a criminal procedure adequate to the new criminogenic realities. In this context, the national legislator has adopted, following other international legal systems, special means of obtaining proof more stringent of rights. Within those special means are included the covert actions, that, being a means to use sparingly, is a key element to fight against violent and highly organized crime. Therefore, the undercover agent, voluntary by nature, develops a set of activities that enables the investigation to use other means of taking evidence and/or probationary diligences itself, with the purpose of providing sufficient proof to the case file. In this milieu, given the high risks involved during the investigation, as well as after its completion, the undercover agent can act upon fictitious identity. This measure can be maintained during the evidentiary phase of the trial. Similarly, given the latent threat that the undercover agent suffers by its inclusion in criminal organizations, as well as the need for his inclusion in future covert actions it is crucial that his participation as a witness in the trial is properly shielded. Thus, when the undercover agent provides, exceptionally, statements in the trial, he shall do so always through videoconference with voice and image distortion. This measure can guarantee the anonymity of the undercover agent and concomitantly, that the adversarial principle and the right of the accused to a fair trial is not prejudiced since, in those circumstances, the diligence will be supervised in its entirety (in the audience and with the undercover agent) by a judge.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work is devoted to the broadband wireless transmission techniques, which are serious candidates to be implemented in future broadband wireless and cellular systems, aiming at providing high and reliable data transmission and concomitantly high mobility. In order to cope with doubly-selective channels, receiver structures based on OFDM and SC-FDE block transmission techniques, are proposed, which allow cost-effective implementations, using FFT-based signal processing. The first subject to be addressed is the impact of the number of multipath components, and the diversity order, on the asymptotic performance of OFDM and SC-FDE, in uncoded and for different channel coding schemes. The obtained results show that the number of relevant separable multipath components is a key element that influences the performance of OFDM and SC-FDE schemes. Then, the improved estimation and detection performance of OFDM-based broadcasting systems, is introduced employing SFN (Single Frequency Network) operation. An initial coarse channel is obtained with resort to low-power training sequences estimation, and an iterative receiver with joint detection and channel estimation is presented. The achieved results have shown very good performance, close to that with perfect channel estimation. The next topic is related to SFN systems, devoting special attention to time-distortion effects inherent to these networks. Typically, the SFN broadcast wireless systems employ OFDM schemes to cope with severely time-dispersive channels. However, frequency errors, due to CFO, compromises the orthogonality between subcarriers. As an alternative approach, the possibility of using SC-FDE schemes (characterized by reduced envelope fluctuations and higher robustness to carrier frequency errors) is evaluated, and a technique, employing joint CFO estimation and compensation over the severe time-distortion effects, is proposed. Finally, broadband mobile wireless systems, in which the relative motion between the transmitter and receiver induces Doppler shift which is different or each propagation path, is considered, depending on the angle of incidence of that path in relation to the direction of travel. This represents a severe impairment in wireless digital communications systems, since that multipath propagation combined with the Doppler effects, lead to drastic and unpredictable fluctuations of the envelope of the received signal, severely affecting the detection performance. The channel variations due this effect are very difficult to estimate and compensate. In this work we propose a set of SC-FDE iterative receivers implementing efficient estimation and tracking techniques. The performance results show that the proposed receivers have very good performance, even in the presence of significant Doppler spread between the different groups of multipath components.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As investors and other users of annual reports often focus their attention on graphs, it is important that they portray accurate and reliable information. However, previous studies show that graphs often distort information and mislead users. This study analyses graph usage in annual reports from the 52 most traded Norwegian companies. The findings suggest that Norwegian companies commonly use graphs, and that the graph distortions, presentational enhancement and measurement distortion, are present. No evidence of selectivity was found. This study recommends development of guidelines for graphical disclosure, and advises preparers and users of annual reports to be aware of misleading graphs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a comprehensive comparison of a current-source converter and a voltage-source converter for three-phase electric vehicle (EV) fast battery chargers. Taking into account that the current-source converter (CSC) is a natural buck-type converter, the output voltage can assume a wide range of values, which varies between zero and the maximum instantaneous value of the power grid phase-to-phase voltage. On the other hand, taking into account that the voltage-source converter (VSC) is a natural boost-type converter, the output voltage is always greater than the maximum instantaneous value of the power grid phase-to-phase voltage, and consequently, it is necessary to use a dc-dc buck-type converter for applications as EV fast battery chargers. Along the paper is described in detail the principle of operation of both the CSC and the VSC for EV fast chargers, as well as the main equations of the power theory and current control strategies. The comparison between both converters is mainly established in terms of the total harmonic distortion of the grid current and the estimated efficiency for a range of operation between 10 kW and 50 kW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado em Direito Tributário e Fiscal

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The MAP-i Doctoral Program of the Universities of Minho, Aveiro and Porto

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work the dielectric properties and ferromagnetic resonance of Polyvinylidene- uoride embedded with 10 wt. % of NiFe2O4 or Ni0.5Zn0.5Fe2O4 nanoparticles are presented. The mechanisms of the dielectric relaxation in these two composites do not differ from each other. For more precise characterization of the dielectric relaxation, a two dimensional distribution of relaxation times was calculated from the temperature dependencies of the complex dielectric permittivity. The results obtained from the 2D distribution and the mean relaxation time are found to be consistent. The dynamics of the dielectric permittivity is described by the Arrhenius law. The energy and attempt time of the dielectric relaxators lie in a narrow energy and time region thus proving that the single type chains of polymer are responsible for a dispersion. The magnetic properties of the composites were investigated using the fer- romagnetic resonance. A single resonance line was observed for both samples. From the temperature dependence (100 K - 310 K) of the resonance eld and linewidth, the origin of the observed line was attributed to the NiFe2O4 and Ni0.5Zn0.5Fe2O4 superparamagnetic nanoparticles. By measuring lms at dif- ferent orientations with respect to the external magnetic eld, the angular dependence of the resonance was observed, indicating the magnetic dipolar in-plane interactions.