1000 resultados para Analog impulse tool (D48)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Arrhythmia recurrence after cardiac radiofrequency ablation (RFA) for atrial fibrillation has been linked to conduction through discontinuous lesion lines. Intraprocedural visualization and corrective ablation of lesion line discontinuities could decrease postprocedure atrial fibrillation recurrence. Intracardiac acoustic radiation force impulse (ARFI) imaging is a new imaging technique that visualizes RFA lesions by mapping the relative elasticity contrast between compliant-unablated and stiff RFA-treated myocardium. OBJECTIVE: To determine whether intraprocedure ARFI images can identify RFA-treated myocardium in vivo. METHODS: In 8 canines, an electroanatomical mapping-guided intracardiac echo catheter was used to acquire 2-dimensional ARFI images along right atrial ablation lines before and after RFA. ARFI images were acquired during diastole with the myocardium positioned at the ARFI focus (1.5 cm) and parallel to the intracardiac echo transducer for maximal and uniform energy delivery to the tissue. Three reviewers categorized each ARFI image as depicting no lesion, noncontiguous lesion, or contiguous lesion. For comparison, 3 separate reviewers confirmed RFA lesion presence and contiguity on the basis of functional conduction block at the imaging plane location on electroanatomical activation maps. RESULTS: Ten percent of ARFI images were discarded because of motion artifacts. Reviewers of the ARFI images detected RFA-treated sites with high sensitivity (95.7%) and specificity (91.5%). Reviewer identification of contiguous lesions had 75.3% specificity and 47.1% sensitivity. CONCLUSIONS: Intracardiac ARFI imaging was successful in identifying endocardial RFA treatment when specific imaging conditions were maintained. Further advances in ARFI imaging technology would facilitate a wider range of imaging opportunities for clinical lesion evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four pigs, three with focal infarctions in the apical intraventricular septum (IVS) and/or left ventricular free wall (LVFW), were imaged with an intracardiac echocardiography (ICE) transducer. Custom beam sequences were used to excite the myocardium with focused acoustic radiation force (ARF) impulses and image the subsequent tissue response. Tissue displacement in response to the ARF excitation was calculated with a phase-based estimator, and transverse wave magnitude and velocity were each estimated at every depth. The excitation sequence was repeated rapidly, either in the same location to generate 40 Hz M-modes at a single steering angle, or with a modulated steering angle to synthesize 2-D displacement magnitude and shear wave velocity images at 17 points in the cardiac cycle. Both types of images were acquired from various views in the right and left ventricles, in and out of infarcted regions. In all animals, acoustic radiation force impulse (ARFI) and shear wave elasticity imaging (SWEI) estimates indicated diastolic relaxation and systolic contraction in noninfarcted tissues. The M-mode sequences showed high beat-to-beat spatio-temporal repeatability of the measurements for each imaging plane. In views of noninfarcted tissue in the diseased animals, no significant elastic remodeling was indicated when compared with the control. Where available, views of infarcted tissue were compared with similar views from the control animal. In views of the LVFW, the infarcted tissue presented as stiff and non-contractile compared with the control. In a view of the IVS, no significant difference was seen between infarcted and healthy tissue, whereas in another view, a heterogeneous infarction was seen to be presenting itself as non-contractile in systole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our long-term goal is the detection and characterization of vulnerable plaque in the coronary arteries of the heart using intravascular ultrasound (IVUS) catheters. Vulnerable plaque, characterized by a thin fibrous cap and a soft, lipid-rich necrotic core is a precursor to heart attack and stroke. Early detection of such plaques may potentially alter the course of treatment of the patient to prevent ischemic events. We have previously described the characterization of carotid plaques using external linear arrays operating at 9 MHz. In addition, we previously modified circular array IVUS catheters by short-circuiting several neighboring elements to produce fixed beamwidths for intravascular hyperthermia applications. In this paper, we modified Volcano Visions 8.2 French, 9 MHz catheters and Volcano Platinum 3.5 French, 20 MHz catheters by short-circuiting portions of the array for acoustic radiation force impulse imaging (ARFI) applications. The catheters had an effective transmit aperture size of 2 mm and 1.5 mm, respectively. The catheters were connected to a Verasonics scanner and driven with pushing pulses of 180 V p-p to acquire ARFI data from a soft gel phantom with a Young's modulus of 2.9 kPa. The dynamic response of the tissue-mimicking material demonstrates a typical ARFI motion of 1 to 2 microns as the gel phantom displaces away and recovers back to its normal position. The hardware modifications applied to our IVUS catheters mimic potential beamforming modifications that could be implemented on IVUS scanners. Our results demonstrate that the generation of radiation force from IVUS catheters and the development of intravascular ARFI may be feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have previously shown that intracardiac acoustic radiation force impulse (ARFI) imaging visualizes tissue stiffness changes caused by radiofrequency ablation (RFA). The objectives of this in vivo study were to (1) quantify measured ARFI-induced displacements in RFA lesion and unablated myocardium and (2) calculate the lesion contrast (C) and contrast-to-noise ratio (CNR) in two-dimensional ARFI and conventional intracardiac echo images. In eight canine subjects, an ARFI imaging-electroanatomical mapping system was used to map right atrial ablation lesion sites and guide the acquisition of ARFI images at these sites before and after ablation. Readers of the ARFI images identified lesion sites with high sensitivity (90.2%) and specificity (94.3%) and the average measured ARFI-induced displacements were higher at unablated sites (11.23 ± 1.71 µm) than at ablated sites (6.06 ± 0.94 µm). The average lesion C (0.29 ± 0.33) and CNR (1.83 ± 1.75) were significantly higher for ARFI images than for spatially registered conventional B-mode images (C = -0.03 ± 0.28, CNR = 0.74 ± 0.68).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Family dogs and dog owners offer a potentially powerful way to conduct citizen science to answer questions about animal behavior that are difficult to answer with more conventional approaches. Here we evaluate the quality of the first data on dog cognition collected by citizen scientists using the Dognition.com website. We conducted analyses to understand if data generated by over 500 citizen scientists replicates internally and in comparison to previously published findings. Half of participants participated for free while the other half paid for access. The website provided each participant a temperament questionnaire and instructions on how to conduct a series of ten cognitive tests. Participation required internet access, a dog and some common household items. Participants could record their responses on any PC, tablet or smartphone from anywhere in the world and data were retained on servers. Results from citizen scientists and their dogs replicated a number of previously described phenomena from conventional lab-based research. There was little evidence that citizen scientists manipulated their results. To illustrate the potential uses of relatively large samples of citizen science data, we then used factor analysis to examine individual differences across the cognitive tasks. The data were best explained by multiple factors in support of the hypothesis that nonhumans, including dogs, can evolve multiple cognitive domains that vary independently. This analysis suggests that in the future, citizen scientists will generate useful datasets that test hypotheses and answer questions as a complement to conventional laboratory techniques used to study dog psychology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Software-based control of life-critical embedded systems has become increasingly complex, and to a large extent has come to determine the safety of the human being. For example, implantable cardiac pacemakers have over 80,000 lines of code which are responsible for maintaining the heart within safe operating limits. As firmware-related recalls accounted for over 41% of the 600,000 devices recalled in the last decade, there is a need for rigorous model-driven design tools to generate verified code from verified software models. To this effect, we have developed the UPP2SF model-translation tool, which facilitates automatic conversion of verified models (in UPPAAL) to models that may be simulated and tested (in Simulink/Stateflow). We describe the translation rules that ensure correct model conversion, applicable to a large class of models. We demonstrate how UPP2SF is used in themodel-driven design of a pacemaker whosemodel is (a) designed and verified in UPPAAL (using timed automata), (b) automatically translated to Stateflow for simulation-based testing, and then (c) automatically generated into modular code for hardware-level integration testing of timing-related errors. In addition, we show how UPP2SF may be used for worst-case execution time estimation early in the design stage. Using UPP2SF, we demonstrate the value of integrated end-to-end modeling, verification, code-generation and testing process for complex software-controlled embedded systems. © 2014 ACM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The detection of latent tuberculosis infection (LTBI) is a major component of tuberculosis (TB) control strategies. In addition to the tuberculosis skin test (TST), novel blood tests, based on in vitro release of IFN-gamma in response to Mycobacterium tuberculosis-specific antigens ESAT-6 and CFP-10 (IGRAs), are used for TB diagnosis. However, neither IGRAs nor the TST can separate acute TB from LTBI, and there is concern that responses in IGRAs may decline with time after infection. We have therefore evaluated the potential of the novel antigen heparin-binding hemagglutinin (HBHA) for in vitro detection of LTBI. METHODOLOGY AND PRINCIPAL FINDINGS: HBHA was compared to purified protein derivative (PPD) and ESAT-6 in IGRAs on lymphocytes drawn from 205 individuals living in Belgium, a country with low TB prevalence, where BCG vaccination is not routinely used. Among these subjects, 89 had active TB, 65 had LTBI, based on well-standardized TST reactions and 51 were negative controls. HBHA was significantly more sensitive than ESAT-6 and more specific than PPD for the detection of LTBI. PPD-based tests yielded 90.00% sensitivity and 70.00% specificity for the detection of LTBI, whereas the sensitivity and specificity for the ESAT-6-based tests were 40.74% and 90.91%, and those for the HBHA-based tests were 92.06% and 93.88%, respectively. The QuantiFERON-TB Gold In-Tube (QFT-IT) test applied on 20 LTBI subjects yielded 50% sensitivity. The HBHA IGRA was not influenced by prior BCG vaccination, and, in contrast to the QFT-IT test, remote (>2 years) infections were detected as well as recent (<2 years) infections by the HBHA-specific test. CONCLUSIONS: The use of ESAT-6- and CFP-10-based IGRAs may underestimate the incidence of LTBI, whereas the use of HBHA may combine the operational advantages of IGRAs with high sensitivity and specificity for latent infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Patients with end-stage renal disease (ESRD) and latently infected with Mycobacterium tuberculosis (LTBI) are at higher risk to develop tuberculosis (TB) than healthy subjects. Interferon-gamma release assays (IGRAs) were reported to be more sensitive than tuberculin skin tests for the detection of infected individuals in dialysis patients.Methods:On 143 dialysis patients prospectively enrolled, we compared the results from the QuantiFERON®-TB Gold assay (QFT), to those of an IGRA in response to in vitro stimulation of circulating mononuclear cells with the mycobacterial latency antigen Heparin-Binding Haemagglutinin purified from Mycobacterium bovis BCG (native HBHA, nHBHA).Results:Seven patients had a past history of active TB and 1 had an undetermined result with both IGRAs. Among the other 135 patients, 94 had concordant results with the QFT and nHBHA-IGRA, 40.0% being negative and therefore not latently infected, and 29.6% being positive and thus LTBI. Discrepant results between these tests were found for 36 patients positive only with the nHBHA-IGRA and 5 only with the QFT.Conclusions:The nHBHA-IGRA is more sensitive than the QFT for the detection of LTBI dialysis patients, and follow-up of the patients will allow us to define the clinical significance of discrepant results between the nHBHA-IGRA and the QFT. © 2013 Dessein et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND. Laboratory data suggest that insulin-like growth factor-1 (IGE-1) may stimulate the growth of different human tumors. At least in acromegalic patients, somatostatin (SMS) analogs, such as lanreotide, suppress the serum levels of growth hormone (GH) and IGE-1. METHODS. To evaluate the tolerability and biologic activity of different doses of lanreotide in patients with advanced colorectal carcinoma, consecutive groups of 3 patients each were subcutaneous treated with lanreotide at doses of 1, 2, 3, 4, 5, or 6 mg three times a day for 2 months. In the event of Grade 3 side effects, 3 additional patients were treated with the same dose before the next dose escalation. Serum samples were obtained on Days 0, 15, 30, and 60 for serum GH, IGF-1, and lanreotide assessment. RESULTS. Twenty-four patients were enrolled and all were evaluable. Except for the 3 and 6 mg doses, for which the observation of a Grade 3 side effect required that an additional three patients be treated, it was sufficient to treat 3 patients at each dose. The overall incidence of side effects was as follows: changes in bowel habits, 83%; abdominal cramps, 79%; diarrhea, 17%; vomiting, 17%; nausea, 21%; steatorrhea, 78%; hyperglycemia, 35%; laboratory hypothyroidism, 39%; gallstones, 13%; and weight loss, 17%. No evidence of an increase in the incidence, intensity, or duration of side effects was observed with dose escalation. Serum IGF-1 levels were as follows: Day 13: 63%, 60%, and 67% of the baseline values for the low (12 mg), intermediate (3-4 mg), and high (5- 6 mg) dose groups, respectively; Day 30: 63%, 59%, and 51%, respectively; and Day 60: 73%, 69%, and 47%, respectively. Serum lanreotide levels declined during treatment in all of the dose groups (90 ng/mL on Day 15, and 35 ng/mL on Day 60 for the 5-6 mg group; 10 ng/mL on Day 15, and 1.5 ng/mL on Day 60 for the 1-2 mg group). No antitumor activity or tumor marker reduction was observed. CONCLUSIONS. No increase in toxicity was observed when subcutaneous lanreotide doses were escalated to 6 mg three times a day for 2 months. The highest doses seemed to maintain reduced serum IGF-1 levels; with the lowest doses, a 'rebound' in serum IGF-1 levels was observed during treatment. Nevertheless, intermittent subcutaneous injections do not ensure constant serum drug concentrations over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

p.103-111

Relevância:

20.00% 20.00%

Publicador:

Resumo:

p.103-111

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the exploitation of overlapping communication with calculation within parallel FORTRAN 77 codes for computational fluid dynamics (CFD) and computational structured dynamics (CSD). The obvious objective is to overlap interprocessor communication with calculation on each processor in a distributed memory parallel system and so improve the efficiency of the parallel implementation. A general strategy for converting synchronous to overlapped communication is presented together with tools to enable its automatic implementation in FORTRAN 77 codes. This strategy is then implemented within the parallelisation toolkit, CAPTools, to facilitate the automatic generation of parallel code with overlapped communications. The success of these tools are demonstrated on two codes from the NAS-PAR and PERFECT benchmark suites. In each case, the tools produce parallel code with overlapped communications which is as good as that which could be generated manually. The parallel performance of the codes also improve in line with expectation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We provide a select overview of tools supporting traditional Jewish learning. Then we go on to discuss our own HyperJoseph/HyperIsaac project in instructional hypermedia. Its application is to teaching, teacher training, and self-instruction in given Bible passages. The treatment of two narratives has been developed thus far. The tool enables an analysis of the text in several respects: linguistic, narratological, etc. Moreover, the Scriptures' focality throughout the cultural history makes this domain of application particularly challenging, in that there is a requirement for the tool to encompass the accretion of receptions in the cultural repertoire, i.e., several layers of textual traditions—either hermeneutic (i.e., interpretive), or appropriations—related to the given core passage, thus including "secondary" texts (i.e., such that are responding or derivative) from as disparate realms as Roman-age and later homiletics, Medieval and later commentaries or supercommentaries, literary appropriations, references to the arts and modern scholarship, etc. in particular, the Midrash (homiletic expansions) is adept at narrative gap filling, so the narratives mushroom at the interstices where the primary text is silent. The genealogy of the project is rooted in Weiss' index of novelist Agnon's writings, which was eventually upgraded into a hypertextual tool, including Agnon's full-text and ancillary materials. Those early tools being intended primarily for reference and research-support in literary studies, the Agnon hypertext system was initially emulated in the conception of HyperJoseph, which is applied to the Joseph story from Genesis. Then, the transition from a tool for reference to an instructional tool required a thorough reconception in an educational perspective, which led to HyperIsaac, on the sacrifice of Isaac, and to a redesign and upgrade of HyperJoseph as patterned after HyperIsaac.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Daedalus is a computer tool, developed by an Italian magistrate - Carmelo Asaro - and integrated in his own daily routine as an investigating magistrate conducting inquiries, then as a prosecutor if and when the case investigated goes to court. This tool has recently been adopted by magistrates in judiciary offices throughout Italy, spawning moreover other related projects. First, this paper describes a sample session with daedalus. Next, an overview of an array of judicial tools leads to positioning daedalus in the context of the spectrum.