705 resultados para Alloy e alloy analyzer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Archaeological excavations carried out in the archaeological site of São Pedro (Southern Portugal) revealed a Chalcolithic settlement occupied in different moments of the 3rd millennium BC. The material culture recovered includes different types of materials, such as ceramics, lithics and metals. The later comprises about 30 artefacts with different typologies such as tools (e.g. awls, chisels and a saw) and weapons (e.g. daggers and arrowheads) mostly belonging to the 2nd and 3rd quarter of the 3rd millennium BC. In the present work the collection of chalcolithic metallic artefacts recovered in São Pedro was characterized. Analytical studies involved micro energy dispersive X-ray fluorescence spectrometry (micro-EDXRF) to determine elemental composition, together with optical microscopy and Vickers microhardness testing for microstructural characterisation and hardness determination. Main results show copper with variable amounts of arsenic and very low content of other impurities, such as iron. Moreover, nearly half of the collection is composed by arsenical copper alloys (As > 2 wt.%) and an association was found between arsenic content and typology since the weapons group (mostly daggers) present higher values than tools (mostly awls). These results suggest some criteria in the selection of arsenic-rich copper ores or smelting products. Furthermore, after casting an artefact would have been hammered, annealed and sometimes, finished with a hammering operation. Additionally, microstructural variations in this collection reveal somewhat different operational conditions during casting, annealing and forging, as expected in such a primitive metallurgy. Moreover the operational sequence seems to be used to achieve the required shape to the object, rather than to intentionally make the alloy harder. Overall, this study suggests that Chalcolithic metallurgists might have a poor control of the addition of arsenic and/or were unable to use this element to increase the hardness of tools and weapons. Finally, the compositions, manufacturing processes and hardness were compared to those from neighbouring regions and different chronological periods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports the precipitation process of Al3Sc structures in an aluminum scandium alloy, which has been simulated with a synchronous parallel kinetic Monte Carlo (spkMC) algorithm. The spkMC implementation is based on the vacancy diffusion mechanism. To filter the raw data generated by the spkMC simulations, the density-based clustering with noise (DBSCAN) method has been employed. spkMC and DBSCAN algorithms were implemented in the C language and using MPI library. The simulations were conducted in the SeARCH cluster located at the University of Minho. The Al3Sc precipitation was successfully simulated at the atomistic scale with the spkMC. DBSCAN proved to be a valuable aid to identify the precipitates by performing a cluster analysis of the simulation results. The achieved simulations results are in good agreement with those reported in the literature under sequential kinetic Monte Carlo simulations (kMC). The parallel implementation of kMC has provided a 4x speedup over the sequential version.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An exterior body panel solution containing a polydicyclopentadiene skin attached to an interior metallic reinforcement through adhesive bonding is being studied to be applied in the MobiCar bonnet. With this solution is expected to achieve lightness, adequate structural integrity and cost-efficiency. However, there is uncertainty regarding to the bonnet adhesiveness since different metallic materials and adhesive types are being considered for its development. Thus, in this paper, several samples are tested through shear loading with the aim of understanding the loading magnitude expected by using polydicyclopentadiene, steel DC04+ZE and aluminum alloy AW5754-H111 as substrates adhesively bonded by an epoxy or a methacrylate. Methacrylate adhesive have shown greater shear strength in all types of adhesive joints. PDCPD joints presented the highest displacements. Surface degradation was considered adequate over abrading once none strength difference was seen between the different surface treatments. Steel treated by cataphoresis has shown the highest joint interface strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia de Materiais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia de Materiais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia de Materiais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia de Materiais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento (Programa Doutoral em Engenharia de Materiais)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Red blood cell (RBC) parameters such as morphology, volume, refractive index, and hemoglobin content are of great importance for diagnostic purposes. Existing approaches require complicated calibration procedures and robust cell perturbation. As a result, reference values for normal RBC differ depending on the method used. We present a way for measuring parameters of intact individual RBCs by using digital holographic microscopy (DHM), a new interferometric and label-free technique with nanometric axial sensitivity. The results are compared with values achieved by conventional techniques for RBC of the same donor and previously published figures. A DHM equipped with a laser diode (lambda = 663 nm) was used to record holograms in an off-axis geometry. Measurements of both RBC refractive indices and volumes were achieved via monitoring the quantitative phase map of RBC by means of a sequential perfusion of two isotonic solutions with different refractive indices obtained by the use of Nycodenz (decoupling procedure). Volume of RBCs labeled by membrane dye Dil was analyzed by confocal microscopy. The mean cell volume (MCV), red blood cell distribution width (RDW), and mean cell hemoglobin concentration (MCHC) were also measured with an impedance volume analyzer. DHM yielded RBC refractive index n = 1.418 +/- 0.012, volume 83 +/- 14 fl, MCH = 29.9 pg, and MCHC 362 +/- 40 g/l. Erythrocyte MCV, MCH, and MCHC achieved by an impedance volume analyzer were 82 fl, 28.6 pg, and 349 g/l, respectively. Confocal microscopy yielded 91 +/- 17 fl for RBC volume. In conclusion, DHM in combination with a decoupling procedure allows measuring noninvasively volume, refractive index, and hemoglobin content of single-living RBCs with a high accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MATE (Monitoring, Analysis and Tuning Environment) es un proyecto que surge en 2004 como tesis doctoral de Anna Sikora con el propósito de investigar la mejora de rendimiento de aplicaciones paralelas a través de la modificación dinámica. Nuestro proyecto supone un paso adelante en cuestiones de calidad de software y pretende dotar al proyecto MATE de una base de desarrollo sólida de cara a futuras lineas de trabajo. Para ello se hace frente a la problemática desde tres perspectivas: la creación de una metodología de desarrollo (y su aplicación sobre el proyecto existente), la implantación de un entorno de desarrollo de soporte y el desarrollo de nuevas características para favorecer la portabilidad y la usabilidad, entre otros aspectos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest document detalla la feina que s'ha dut a terme per desenvolupar el projecte Open Chess Game Analyzer. La finalitat del mateix és desenvolupar un aplicatiu lliure que sigui capaç d'analitzar partides d'escacs a partir d'un fitxer PGN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT Monoenergetic imaging with dual-energy CT has been proposed to reduce metallic artifacts in comparison with conventional polychromatic CT. The purpose of this study is to systematically evaluate and define the optimal dual-energy CT imaging parameters for specific cervical spinal implant alloy compositions. METHODS Spinal fixation rods of cobalt-chromium or titanium alloy inserted into the cervical spine section of an Alderson Rando anthropomorphic phantom were imaged ex vivo with fast-kilovoltage switching CT at 80 and 140 peak kV. The collimation width and field of view were varied between 20 and 40 mm and medium to large, respectively. Extrapolated monoenergetic images were generated at 70, 90, 110, and 130 kiloelectron volts (keV). The standard deviation of voxel intensities along a circular line profile around the spine was used as an index of the magnitude of metallic artifact. RESULTS The metallic artifact was more conspicuous around the fixation rods made of cobalt-chromium than those of titanium alloy. The magnitude of metallic artifact seen with titanium fixation rods was minimized at monoenergies of 90 keV and higher, using a collimation width of 20 mm and large field of view. The magnitude of metallic artifact with cobalt-chromium fixation rods was minimized at monoenergies of 110 keV and higher; collimation width or field of view had no effect. CONCLUSIONS Optimization of acquisition settings used with monoenergetic CT studies might yield reduced metallic artifacts.