986 resultados para Air Particulate Matter
Resumo:
Atmospheric aerosols of four aerodynamic size ranges were collected using high volume cascade impactors in an extremely busy roadway tunnel in Lisbon (Portugal). Dust deposited on the tunnel walls and guardrails was also collected. Average particle mass concentrations in the tunnel atmosphere were more than 30 times higher than in the outside urban background air, revealing its origins almost exclusively from fresh vehicle emissions. Most of the aerosol mass was concentrated in submicrometer fractions (65%), and polycyclic aromatic hydrocarbons (PAH) were even more concentrated in the finer particles with an average of 84% of total PAH present in sizes smaller than 0.49 mu m. The most abundant PAH were methylated phenanthrenes, fluoranthene and pyrene. About 46% of the total PAH mass was attributed to lower molecular weight compounds (two and three rings), suggesting a strong influence of diesel vehicle emissions on the production of local particulate PAH. The application of diagnostic ratios confirmed the relevance of this source of PAH in the tunnel ambient air. Deposited dust presented PAH profiles similar to the coarser aerosol size range, in agreement with the predominant origin of coarser aerosol particles from soil dust resuspension and vehicle wear products. (c) 201 1 Elsevier Ltd. All rights reserved.
Resumo:
The objectives of this study were to (1) conduct an elemental characterization of airborne particles sampled in Cape Verde and (2) assess the influence of Sahara desert on local suspended particles. Particulate matter (PM10) was collected in Praia city (14°94'N; 23°49'W) with a low-volume sampler in order to characterize its chemical composition by k0-INAA. The filter samples were first weighed and subsequently irradiated at the Portuguese Research Reactor. Results showed that PM10 concentrations in Cape Verde markedly exceeded the health-based air quality standards defined by the European Union (EU), World Health Organization (WHO), and U.S. Environmental Protection Agency (EPA), in part due to the influence of Sahara dust transport. The PM10 composition was characterized essentially by high concentrations of elements originating from the soil (K, Sm, Co, Fe, Sc, Rb, Cr, Ce, and Ba) and sea (Na), and low concentrations of anthropogenic elements (As, Zn, and Sb). In addition, the high concentrations of PM measured in Cape Verde suggest that health of the population may be less affected compared with other sites where PM10 concentrations are lower but more enriched with toxic elements.
Resumo:
Versão preprint.
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
Organic waste is a rich substrate for microbial growth, and because of that, workers from waste industry are at higher risk of exposure to bioaerosols. This study aimed to assess fungal contamination in two plants handling solid waste management. Air samples from the two plants were collected through an impaction method. Surface samples were also collected by swabbing surfaces of the same indoor sites. All collected samples were incubated at 27◦C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. Air samples were also subjected to molecular methods by real-time polymerase chain reaction (RT PCR) using an impinger method to measure DNA of Aspergillus flavus complex and Stachybotrys chartarum. Assessment of particulate matter (PM) was also conducted with portable direct-reading equipment. Particles concentration measurement was performed at five different sizes (PM0.5; PM1; PM2.5; PM5; PM10). With respect to the waste sorting plant, three species more frequently isolated in air and surfaces were A. niger (73.9%; 66.1%), A. fumigatus (16%; 13.8%), and A. flavus (8.7%; 14.2%). In the incineration plant, the most prevalent species detected in air samples were Penicillium sp. (62.9%), A. fumigatus (18%), and A. flavus (6%), while the most frequently isolated in surface samples were Penicillium sp. (57.5%), A. fumigatus (22.3%) and A. niger (12.8%). Stachybotrys chartarum and other toxinogenic strains from A. flavus complex were not detected. The most common PM sizes obtained were the PM10 and PM5 (inhalable fraction). Since waste is the main internal fungal source in the analyzed settings, preventive and protective measures need to be maintained to avoid worker exposure to fungi and their metabolites.
Resumo:
Traffic emissions and tobacco smoke are considered two main sources of polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air. In this study, the impact of these sources on the level of fine particulate matter (PM2.5) and on the distribution of 15 PAHs regarded as priority pollutants by the US-EPA on PM2.5 were evaluated and compared. Outdoor and indoor PM2.5 samples were collected during winter 2008 in Oporto city in Portugal, for sampling periods of 12 and 24 hours, respectively. The outdoor PM2.5 were sampled at one site directly influenced by traffic emissions and the indoor PM2.5 samples were collected at one home directly influenced by tobacco smoke and another one without smoke. A methodology based on microwave-assisted extraction and liquid chromatography with fluorescence detection was applied for the efficient PAHs determination in indoor and outdoor PM2.5. PAHs in indoor PM2.5 concentrations were significantly influenced by the presence of traffic and tobacco smoking emissions. The mean of ΣPAHs in the outdoor traffic PM2.5 was not significantly different from the value attained in the indoor without smoking site. The tobacco smoke increased significantly PAHs concentrations on average about 1000 times more, when compared with the outdoor profile samples suggesting that tobacco smoking may be the most important source of indoor PAHs pollution.
Resumo:
A methodology based on microwave-assisted extraction (MAE) and LC with fluorescence detection (FLD) was investigated for the efficient determination of 15 polycyclic aromatic hydrocarbons (PAHs) regarded as priority pollutants by the US Environmental Protection Agency and dibenzo(a,l)pyrene in atmospheric particulate samples. PAHs were successfully extracted from real outdoor particulate matter (PM) samples with recoveries ranging from 81.4±8.8 to 112.0±1.1%, for all the compounds except for naphthalene (62.3±18.0%) and anthracene (67.3±5.7%), under the optimum MAE conditions (30.0 mL of ACN for 20 min at 110ºC). No clean-up steps were necessary prior to LC analysis. LOQs ranging from 0.0054 ng/m3 for benzo( a)anthracene to 0.089 ng/m3 for naphthalene were reached. The validated MAE methodology was applied to the determination of PAHs from a set of real world PM samples collected in Oporto (north of Portugal). The sum of particulate-bound PAHs in outdoor PM ranged from 2.5 and 28 ng/m3.
Resumo:
Because polycyclic aromatic hydrocarbons (PAHs) have been proven to be toxic, mutagenic, and/or carcinogenic, there is widespread interest in analyzing and evaluating exposure to PAHs in atmospheric environments influenced by different emission sources. Because traffic emissions are one of the biggest sources of fine particles, more information on carcinogenic PAHs associated with fine particles needs to be provided. Aiming to further understand the impact of traffic particulate matter (PM) on human health, this study evaluated the influence of traffic on PM10 (PM with aerodynamic diameter <10 µm) and PM2.5 (PM with aerodynamic diameter <2.5 µm), considering their concentrations and compositions in carcinogenic PAHs. Samples were collected at one site influenced by traffic emissions and at one reference site using lowvolume samplers. Analysis of PAHs was performed by microwave-assisted extraction combined with liquid chromatography (MAE-LC); 17 PAHs, including 9 carcinogenic ones, were quantified. At the site influenced by traffic emissions, PM10 and PM2.5 concentrations were, respectively, 380 and 390% higher than at the background site. When influenced by traffic emissions, the total concentration of nine carcinogenic compounds (naphthalene, chrysene, benzo(a)anthracene, benzo(b) fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, and dibenzo(a,l)pyrene) was increased by 2400 and 3000% in PM10 and PM2.5, respectively; these nine carcinogenic compounds represented 68 and 74% of total PAHs (ƩPAHs) for PM10 and PM2.5, respectively. All PAHs, including the carcinogenic compounds, were mainly present in fine particles. Considering the strong influence of these fine particles on human health, these conclusions are relevant for the development of strategies to protect public health.
Resumo:
Every year European citizens become victims of devastating fires, which are especially disastrous for Southern European countries. Apart from the numerous health and economic consequences, fires generate hazardous pollutants that are introduced into the environment, thus representing serious risks for public health. In that regard, particulate matter (PM) is of amajor concern. Thus, the objectives of thisworkwere to characterize the trend of forest fire occurrences and burnt area during the period of 2005 and 2010 and to study the influence of forest fires on levels of particulatematter PM10 and PM2.5. In 2010, 22,026 forest fires occurred in Portugal. The northern region was the most affected by forest fires, with 27% of occurrences in Oporto district. The annual means of PM10 and PM2.5 concentrations at two urban background sites were 25±14 μg m−3 and 8.2±4.9 μg m−3, and 17±13 μg m−3 and 7.3±5.9 μg m−3, respectively. At both sites the highest levels of PMfractionswere observed during July and August of 2010, corresponding to the periods when majority (66%) of forest fires occurred. Furthermore, PM10 daily limit at the two sites was exceeded during 20 and 5 days, respectively; 56%, and respectively 60% of those exceedances occurred during the forest fire season. Considering that the risks of forest fire ignition and severity are enhanced with elevated temperatures, the climate change might increase the environmental impacts of forest fires.
Resumo:
A Qualidade do Ar Interior (QAI) é um fator de grande preocupação. A importância de manter um ambiente salubre é mais acentuada em estabelecimentos escolares (EE), tendo em conta, que no interior destes permanecem crianças durante um elevado período de tempo. É fundamental garantir uma boa QAI nos edifícios escolares, de forma a salvaguardar a saúde, o bem-estar e o conforto dos ocupantes, bem como, não comprometer o seu desempenho escolar. Recentemente, foram construídos novos edifícios escolares e alguns dos existentes foram alvo de obras de remodelação. Contudo, a crescente tendência em construir edifícios cada vez mais herméticos, com vista à diminuição dos gastos de energia, origina problemas como a reduzida ventilação dos espaços. Vários estudos têm demonstrado a influência das atividades de limpeza na QAI. No entanto, verifica-se que na maioria das escolas não existem ainda procedimentos de limpeza padronizados. A falta de instruções de trabalho e a ausência de formação às assistentes operacionais pode comprometer a eficácia dos procedimentos de higienização, o que poderá ter influência na QAI dos espaços. Este estudo teve como principal objetivo avaliar a QAI em escolas básicas de 1.º ciclo. Foram contemplados no estudo fatores como a tipologia do edifício, a ocupação das salas e as atividades de limpeza. Procedeu-se à caracterização dos EE e à monitorização de parâmetros ambientais, como a temperatura do ar, a humidade relativa, a velocidade do ar, o dióxido de carbono, o monóxido de carbono, as partículas, os microrganismos mesófilos totais e os fungos. Estes parâmetros foram avaliados nas salas com ocupação, sem ocupação e durante a implementação de um plano de higienização. A ventilação inadequada parece ser o fator que mais condiciona a QAI das salas de aula avaliadas. Registaram-se elevadas concentrações de dióxido de carbono e de microrganismos mesófilos totais, que parecem estar relacionados com a permanência dos ocupantes nos locais e com a falta de ventilação adequada dos espaços. A concentração de dióxido de carbono foi mais elevada em edifícios recentes. Os picos elevados na concentração de partículas parecem estar associados com as atividades dos ocupantes. Obtiveram-se concentrações menores de fungos e de microrganismos mesófilos totais ao longo da implementação do plano de higienização, o que poderá significar que os procedimentos de limpeza contribuem para reduzir os níveis de contaminação dos espaços interiores. No entanto, tendo em conta, que a concentração de microrganismos mesófilos totais permaneceu elevada, as operações de limpeza parecem não ser suficientes para garantir uma boa QAI. O aumento da ventilação dos espaços poderia contribuir significativamente para a melhoria da QAI dos espaços avaliados.
Resumo:
The physiological responses of the clam R. decussatus from the Ria Formosa, southern Portugal, were examined in relation to normoxia, hypoxia (11, 6, 3 and 1.2 kPa) and anoxia; acute elevation of temperature (at 20, 27 and 32 °C), and its effect on the resistance to air exposure (at 20, 28 and 35 °C); current velocity (0.6, 3, 8 17, 24 and 36 cm. s-1) and turbidity (10, 100 and 300 mg. l-1 dry weight of particulate matter), and the efficiency of this species in retaining particles of different size (at 10 and 100 mg. l-1); and to copper contamination considering both short-term acute exposure to high levels (0.1-10 mg Cu. l-1) and chronic environmental levels (0.01 mg Cu. l-1). Clearance rates, respiration rates, absorption efficiency and excretion rates were assessed through the physiological energetics in terms of the energy budget and scope for growth (SFG). Stress independent respiration rates (R) and clearance rates (CR) were observed in relation to hypoxia down to 12 kPa and 6 kPa, respectively. Anoxic rates were 3.6 % of normoxic rates. Scope for growth was greatly reduced under extreme hypoxia (14 % of SFG in normoxia). Respiration rate was temperature independent in the range 20-32 °C but the decline in clearance rate resulted in negative SFG at 32 °C. Gaping during air exposure and the maintenance of faster aerobic metabolism led to 100 % mortality in 20 hours at 35 °C, 4 days at 28 °C and 5 days at 20 °C. Low current velocities (≤ 8 cm. s-1) supported high clearance rates. Shear stresses ≥ 0.9 Pa induced sediment movement and disturbed the feeding processes resulting in decreased clearance rates (at 36 cm. s-1, is 10 % of maximum CR). The observed ability of jetting out depleted water at a different level than the one of the inhalant current results is an important adaptation of clams to the slow currents of sheltered environments. Ingestion at high seston concentrations (> 100 mg. l-1) is controled by reducing the amount filtered, lowering CR (to 30 % of CR at low seston loads) and producing pseudofeces. Observed efficient retention of particles (70-100 %) in the range 3 to 8 μm is beneficial when algal cells are diluted by fine silt particles as it is likely to occur in the clams natural environment. R. decussatus in the short term escaped the exposure to copper by valve closure and therefore acute tests are not applicable to adult clams of this species. At environmental levels chronic exposure to copper did not induce lethal effects during the exposure period (20 days), but scope for growth was reduced to c. 30 %, indicating sustained impairment of physiological functions. The sensitivity of the physiological energetics and the integrated scope for growth measurement in assessing stress effects caused by natural environmental factors was highlighted.
Resumo:
OBJECTIVE To analyze the effect of air pollution and temperature on mortality due to cardiovascular and respiratory diseases. METHODS We evaluated the isolated and synergistic effects of temperature and particulate matter with aerodynamic diameter < 10 µm (PM10) on the mortality of individuals > 40 years old due to cardiovascular disease and that of individuals > 60 years old due to respiratory diseases in Sao Paulo, SP, Southeastern Brazil, between 1998 and 2008. Three methodologies were used to evaluate the isolated association: time-series analysis using Poisson regression model, bidirectional case-crossover analysis matched by period, and case-crossover analysis matched by the confounding factor, i.e., average temperature or pollutant concentration. The graphical representation of the response surface, generated by the interaction term between these factors added to the Poisson regression model, was interpreted to evaluate the synergistic effect of the risk factors. RESULTS No differences were observed between the results of the case-crossover and time-series analyses. The percentage change in the relative risk of cardiovascular and respiratory mortality was 0.85% (0.45;1.25) and 1.60% (0.74;2.46), respectively, due to an increase of 10 μg/m3 in the PM10 concentration. The pattern of correlation of the temperature with cardiovascular mortality was U-shaped and that with respiratory mortality was J-shaped, indicating an increased relative risk at high temperatures. The values for the interaction term indicated a higher relative risk for cardiovascular and respiratory mortalities at low temperatures and high temperatures, respectively, when the pollution levels reached approximately 60 μg/m3. CONCLUSIONS The positive association standardized in the Poisson regression model for pollutant concentration is not confounded by temperature, and the effect of temperature is not confounded by the pollutant levels in the time-series analysis. The simultaneous exposure to different levels of environmental factors can create synergistic effects that are as disturbing as those caused by extreme concentrations.
Resumo:
Mestrado em Segurança e Higiene no Trabalho
Resumo:
According to numerous studies, airborne nanoparticles have a potential to produce serious adverse human health effects when deposited into the respiratory tract. The most important parts of the lung are the alveolar regions with their enormous surface areas and potential to transfer nanoparticles into the blood stream. These effects may be potentiated in case of the elderly, since this population is more susceptible to air pollutants in general and more to nanoparticles than larger particles. The main goal of this investigation was to determine the exposure of institutionalized elders to nanoparticles using Nanoparticle Surface Area Monitor (NSAM) equipment to calculate the deposited surface area (DSA) of nanoparticles into elderly lungs. In total, 193 institutionalized individuals over 65 yr of age were examined in four elderly care centers (ECC). The occupancy daily pattern was achieved by applying a questionnaire, and it was concluded that these subjects spent most of their time indoors, including the bedroom and living room, the indoor microenvironments with higher prevalence of elderly occupancy. The deposited surface area ranged from 10 to 46 mu m(2)/cm(3). The living rooms presented significantly higher levels compared with bedrooms. Comparing PM10 concentrations with nanoparticles deposited surface area in elderly lungs, it is conceivable that living rooms presented the highest concentration of PM10 and were similar to the highest average DSA. The temporal distribution of DSA was also assessed. While data showed a quantitative fluctuation in values in bedrooms, high peaks were detected in living rooms.
Resumo:
The objective of this study was to investigate an association between pre-harvest sugarcane burning and respiratory diseases in children under five years of age. The following data were collected in five schools in the city of Araraquara, SP, Southeastern Brazil, between March and June 2009: daily records of absences and the reasons stated for these absences, total concentration of suspended particulate matter (µg/m3), and air humidity. The relationship between the percentage of school absences due to respiratory problems and the concentration of particulate matter in March and from April to June presented a distinct behavior: absences increased alongside the increase in particulate matter concentration. The use of school absences as indicators of this relationship is an innovative approach.