974 resultados para Abdominal Aortic Aneurism


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Guidelines proposed bioprosthesis implantation for aortic valve disease if the patients were at least 65 years old at the time of surgery, with a trend towards even younger patients in recent years. Considering the adverse effects of lifetime anticoagulation, new biological valves (less prone to degeneration) and new technologies may lead patients and surgeons to different choices. Therefore, it is interesting to analyse the results of aortic bioprosthetic valve replacement in patients aged <65 years at the time of surgery. METHODS From January 2000 to December 2010, 84 patients aged <65 years at the time of surgery had undergone an aortic bio-prosthetic valve replacement. A mid-term follow-up [(FU) mean FU time: 54.4 ± 39.2 months] was done in August 2011 in all patients (FU completeness: 100%). Results were compared with patients who had a mechanical prosthetic aortic valve replacement during the same period. RESULTS The reoperation rate for structural valve degeneration (SVD) of bioprostheses was 6% and occurred exclusively among patients <56 years. Contraindications for anticoagulation determined the choice of a bioprosthesis among 83% of these patients. The personal preference to avoid anticoagulation was the leading cause in 68% of the older patients (56-65 years). Neurological complications occurred more frequently in the mechanical control group. CONCLUSIONS Reoperations for SVD after bioprosthesis implantation occurred exclusively among younger patients (<56 years), not suitable for systemic anticoagulation. Previous studies, together with our experience, are in favour of an age limit between 56 and 60 years, taking into consideration alternative transcatheter approaches to SVD treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New approaches to the clinical treatment of traumatic nerve injuries may one day utilize stem cells to enhance nerve regeneration. Adipose-derived stem cells (ASC) are found in abundant quantities and can be harvested by minimally invasive procedures that should facilitate their use in such regenerative applications. We have analyzed the properties of human ASC isolated from the deep and superficial layers of abdominal fat tissue obtained during abdominoplasty procedures. Cells from the superficial layer proliferate significantly faster than those from the deep layer. In both the deep and superficial layers, ASC express the pluripotent stem cell markers oct4 and nanog and also the stro-1 cell surface antigen. Superficial layer ASC induce the significantly enhanced outgrowth of neurite-like processes from neuronal cell lines when compared with that of deep layer cells. However, analysis by reverse transcription with the polymerase chain reaction and by enzyme-linked immunosorbent assay has revealed that ASC isolated from both layers express similar levels of the following neurotrophic factors: nerve growth factor, brain-derived neurotrophic factor and glial-derived neurotrophic factor. Thus, human ASC show promising potential for the treatment of traumatic nerve injuries. In particular, superficial layer ASC warrant further analysis of their neurotrophic molecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular complications of cocaine abuse include myocardial ischemia and infarction, dysrhythmias, cardiomyopathies and aortic dissection. The case in point pertains to a 26-year-old, Caucasian male, substance abuser who suffered a thoracic aortic dissection following the use of crack cocaine. The autopsy and histological findings showed a connective tissue abnormality including a focal microcystic medial necrosis and a fragmentation of the elastic fibers in the arterial walls. Blood concentrations of cocaine and benzoylecgonine, taken individually, were considered to be within a potentially toxic range. Blood concentrations of methadone also indicated use of this drug at the same time. The small amounts of morphine found in the blood and urine were compatible with heroine or morphine use more than 24 h before death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Visceral obesity (VO) increases technical difficulty in laparoscopic surgery. The body mass index (BMI) does not always correlate to intra-abdominal fat distribution. Our hypothesis was that simple anthropometric measures that reflect VO, could predict technical difficulty in laparoscopic colorectal surgery, as reflected by the operative time, more accurately than the BMI. METHODS: Charts of all consecutive patients who underwent laparoscopic left colon resection in our institution between 2007 and 2010 were reviewed retrospectively. On a preoperative CT scan, anthropometric measures were taken on an axial plane at the L4-L5 level. Demographic, operative and anthropometric CT measures were correlated with the operative time. Logistic regression analysis was performed to assess the value of anthropometric CT measures or BMI to predict the duration of the colectomy. RESULTS: 121 patients with elective left colon resection for benign (56%) or malignant disease (44%) were included. There were 74 sigmoid resections (61%), 21 left hemicolectomies (17%) and 26 low anterior resections (22%). A longer sagittal abdominal diameter (≥24.8 cm) was significantly associated with longer corrected operative time (248 vs. 228 min, p = 0.043). In multivariate analysis, greater sagittal abdominal diameter, sagittal internal diameter and abdominal perimeter were significantly associated with longer operative time. No significant association was found for the BMI neither in univariate nor in multivariate analysis. CONCLUSIONS: This study suggests that simple linear measures taken on a CT scan, such as sagittal abdominal diameter, sagittal internal diameter and abdominal perimeter, may predict longer operative time in laparoscopic left colonic resections more accurately than BMI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aims of the study were to evaluate the prevalence of acute coronary syndrome (ACS) among patients presenting with atypical chest pain who are evaluated for acute aortic syndrome (AAS) or pulmonary embolism (PE) with computed tomoangiography (CTA) and discuss the rationale for the use of triple rule-out (TRO) protocol for triaging these patients. METHODS: This study is a retrospective analysis of patients presenting with atypical chest pain and evaluated with thoracic (CTA), for suspicion of AAS/PE. Two physicians reviewed patient files for demographic characteristics, initial CT and final clinical diagnosis. Patients were classified according to CTA finding into AAS, PE and other diagnoses and according to final clinical diagnosis into AAS, PE, ACS and other diagnoses. RESULTS: Four hundred and sixty-seven patients were evaluated: 396 (84.8%) patients for clinical suspicion of PE and 71 (15.2%) patients for suspicion of AAS. The prevalence of ACS and AAS was low among the PE patients: 5.5% and 0.5% respectively (P = 0.0001), while the prevalence of ACS and PE was 18.3% and 5.6% among AAS patients (P = 0.14 and P = 0.34 respectively). CONCLUSION: The prevalence of ACS and AAS among patients suspected clinically of having PE is limited while the prevalence of ACS and PE among patients suspected clinically of having AAS is significant. Accordingly patients suspected for PE could be evaluated with dedicated PE CTA while those suspected for AAS should still be triaged using TRO protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os autores relatam um caso de tumor de pequenas células redondas desmoplásico intra-abdominal acometendo paciente do sexo masculino, de 21 anos de idade, atendido com quadro de dor abdominal, trombose do membro inferior direito e perda da função renal, de causa obstrutiva. A investigação demonstrou volumosa lesão abdominopélvica, sólida, bocelada, com áreas císticas internas, situada posteriormente à bexiga, causando obstrução ureteral, compressão da veia ilíaca direita e oclusão parcial do reto, além de acometimento de linfonodos intra e retroperitoneais. São descritos os achados cirúrgicos, de ultra-sonografia, tomografia computadorizada e ressonância magnética, bem como aqueles do estudo macroscópico, microscopia e imuno-histoquímica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Management of degenerated aortic valve bioprosthesis classically requires redo surgery, but transcatheter aortic valve-in-valve implantation is becoming a valid alternative in selected cases. In the case of a degenerated Mitroflow bioprosthesis, TAVR is associated with an additional challenge due to a specific risk of coronary occlusion. We aimed to assess the safety and feasibility of transfemoral valve-in-valve implantation of the new Edwards Sapien 3 (Edwards Lifesciences) in a degenerated Mitroflow bioprosthesis (Sorin Group, Inc). METHODS: We report here the safety and feasibility of transfemoral valve-in-valve implantation of a 23 mm Edwards Sapien 3 in a degenerated 25 mm Mitroflow valve and describe the specific assessment of the risk of coronary obstruction using a multi-imaging modality. RESULTS: The final result showed an absence of aortic regurgitation and a mean transvalvular gradient of 14 mm Hg. The patient had no major adverse cardiovascular events at 30-day follow-up. CONCLUSION: Transcatheter valve-in-valve implantation of an Edwards Sapien 3 in a degenerated Mitroflow is feasible and safe, considering a careful assessment of the risk of coronary obstruction with Mitroflow bioprosthesis due to leaflets mounted externally to the stent.