995 resultados para 158-957E
Resumo:
A self-consistent theory of plasma response to a single laser beam is proposed. The driving pump is not viewed as invariant during its interaction with the plasmas. Its modulation by the plasmas has an obvious influence on the strength of the wakefield behind the pulse. This suggests that the compression of the low-intensity pulse by the plasmas might be a possible way to excite largae-amplitude wakefield. (C) 2003 American Institute of Physics.
Resumo:
In order to carry out the Multi-annual Guidance Programmes (MGP) the national fishing fleets of the EU were divided into mostly homogenous fleet segments. The current paper describes the single segments of thc German fishing fleet and summarizes their characteristics such as vessel capacity (tonnage in GRT), machine performance (power in kW) and vessel size (total length in m). Another table lists the averaged landings separated per stock and segment for the period from 1990 to 1994.
Resumo:
[ES] La presión que la sociedad ejerce sobre sus miembros hace que , exista un tendencia generalizada a la excesiva preocupación por el peso y la apariencia física. Se estudiaron las actitudes frente al peso de 526 estudiantes, 158 hombres y 368 mujeres. Muestran un deseo de ser más delgados de lo que son aunque consideran su peso menor al saludable.
Resumo:
This account concentrates on the six species of crayfish found in Austria, and the current state of knowledge on their distribution and laws affecting conservation. In general the occurrence and distribution of crayfish in Austria is poorly known, although information obtained by researchers and the general public, after careful checking, is increasing. Three native crayfish species occur in Austria: Austropotamobius torrentium which is relatively widespread, A. pallipes with a restricted distribution, and Astacus astacus which is widespread. Three species of non-native (alien) crayfish have been recorded from a total of 158 localities in Austria. They are Astacus leptodactylus from eastern Europe, and two Nearctic species: Pacifastacus leniusculus and Orconectes limosus. The introduction of alien species causes considerable problems as they act as vectors of crayfish plague and are able to outcompete native species by higher reproductive capacities.
Resumo:
O objetivo do presente estudo clínico é verificar a reprodutibilidade intra e interexaminadores de um critério de diagnóstico de cárie dentária (Nyvad et al. 1999) aplicado na dentição decídua, e avaliar o tempo médio necessário para a realização do exame clínico utilizando o referido critério. O mesmo é baseado na combinação de métodos visuais e táteis e propõe a diferenciação entre lesões ativas e inativas, tanto para lesões cavitadas quanto para não cavitadas. A amostra total consistiu de 80 crianças de três a sete anos de idade, de ambos os sexos, estudantes do Centro Educacional Terra Santa (Petrópolis/ RJ). Os responsáveis assinaram um termo de consentimento livre e esclarecido e o trabalho foi aprovado pelo Comitê de Ética em Pesquisa do HUPE-UERJ. Os exames foram realizados após escovação supervisionada, em consultório odontológico sob iluminação artificial, após 3-5s de secagem com ar comprimido, por dois examinadores treinados pelas autoras do índice e calibrados. As concordâncias intra e interexaminadores foram avaliadas pelo percentual de concordância (%) e pelo teste kappa (k), considerando a superfície dentária como unidade de análise e os seguintes pontos de corte: 1) hígida versus cariada; 2) ativa versus inativa; 3) descontinuidade versus hígida; e 4) cavitada versus hígida. O % e o valor de k para confiabilidade interexaminadores para cada ponto de corte foram: 1) % = 0,97 e k = 0,82 (IC: 0,80 - 0,85); 2) % = 0,98 e k = 0,80 (IC: 0,76 - 0,83); 3) % = 0,99 e k = 0,90 (IC: 0,88 - 0,93); 4) % = 99,0 e k = 0,95 (IC: 0,92 - 0,97). O % e o valor de k para confiabilidade intraexaminador para cada ponto de corte foram: 1) % = 0,98 e k = 0,86 (IC: 0,84 - 0,86); 2) % = 0,99 e k = 0,86 (IC: 0,83 - 0,89); 3) % = 0,99 e k = 0,94 (IC: 0,92 - 0,96); 4) % = 0,99 e k = 0,98 (IC: 0,96 - 0,99). O maior % de discordância (65,3% - 158/242) concentrou-se na diferenciação entre supefícies hígidas e lesões não cavitadas: 33,5% (81/242) entre superfície hígida e lesão não cavitada inativa; 26,0% (63/242), entre superfície hígida e lesão não cavitada ativa; e 5,8% (14/242), entre lesão não cavitada ativa e lesão não cavitada inativa. O tempo necessário para realização do exame clínico foi em média 226,5s (128,53). Conclui-se que o índice apresentou reprodutibilidade variando de substancial à quase perfeita e um tempo de exame viável, mostrando-se consistente e reproduzível para a realização de estudos clínicos de cárie dentária na dentição decídua.
Resumo:
This partial translation of a bigger publication provides an identification key to the aquatic plant Hydrillae (Hydrocharitaceae) in Europe. Illustrations are included.
Resumo:
[ES]Mediante este proyecto, se trata de buscar diferentes alternativas de valorización energética de residuos forestales, analizar su proceso y los equipos involucrados, y al final elegir la más adecuada en base a ciertos criterios.
Resumo:
Este estudo teve como objetivo avaliar, in vitro, a citotoxicidade dos cimentos endodônticos Densell Endo, Pulp-Fill, Endofill, Sealer 26, Pulp Canal Sealer e GuttaFlow após 12, 24 e 72 horas de tempo de contato, utilizando-se uma linhagem de células endoteliais ECV-304. Para a avaliação da viabilidade celular, utilizou-se o teste de citotoxicidade MTT. Para cada cimento foram preparados 12 corpos de prova que foram distribuídos em seis grupos experimentais de acordo com as marcas comerciais, sendo quatro para cada tempo. Foi criado um grupo controle que não foi submetido à ação de cimento. Para avaliação do efeito dos cimentos sobre as células endoteliais, os corpos de prova foram inseridos nos poços da placa cultura, incubados a 37C em presença de 5% de CO2 e 100% de umidade. Os testes MTT foram realizados, em quadruplicata, após 12, 24 e 72 horas de contato das amostras com o tapete celular. Foi utilizada a prova Two-Way Anova com o teste Post Hoc de Bonferroni com nível de significância de 5%. Na análise de 12 horas, foi possível observar que o cimento GuttaFlow apresentou média de absorbância de 0,055, seguido do Sealer 26 (média = 0,038). Os cimentos Pulp Canal Sealer e Densell Endo apresentaram a mesma média de absorbância (0,031). O Pulp Fill e o Endofill foram os cimentos que apresentaram maior citotoxicidade (média de absorbância = 0,024 e 0,021, respectivamente). O grupo controle apresentou média de absorbância de 0,158. Em 24 horas observou-se que os cimentos GuttaFlow e Sealer 26 apresentaram as maiores médias de absorbância (0,041 e 0,037, respectivamente), seguidos pelo cimento Pulp Canal Sealer que apresentou média de absorbância de 0,035. Já os cimentos Densell Endo e Pulp Fill apresentaram médias de absorbância de 0,033 e 0,032, respectivamente. O cimento Endofill apresentou uma média de 0,026 e o grupo controle de 0,086. Quando analisados em 72 horas, o cimento Pulp Canal Sealer obteve média de absorbância de 0,049, seguido dos cimentos GuttaFlow e Pulp Fill, ambos com 0,048. Os cimentos Densell Endo, Sealer 26 e Endofill apresentaram respectivamente, médias de 0,044, 0,040 e 0,036. O grupo controle diferenciou-se significativamente de todos os grupos em todos os tempos. Quando analisadas as médias gerais de absorbância dos grupos analisados observou-se que o cimento GuttaFlow se apresentou como o cimento com menor índice de citotoxicidade, apresentando média de absorbência de 0,048. Logo após, apresentando médias de absorbância iguais (0,038) encontraram-se os cimentos Pulp Canal Sealer e Sealer 26; seguidos do Densell Endo e do Pulp Fill, com 0,036 e 0,035, respectivamente. O grupo controle apresentou média de absorbância de 0,098. Portanto, tendo como base os resultados obtidos, pôde-se concluir que o cimento Endofill foi o que apresentou maior citotoxicidade e o cimento GuttaFlow, o menos citotóxico.
Resumo:
Tesis con Mención de Doctor Internacional
Resumo:
Isotope shifts of Kα1 x-ray transitions were measured for the Neodymium isotopes Nd 142, 143, 144, 145, 146, 148 and 150, the Samarium isotopes Sm 147, 148, 149, 150, 152 and 154, the Gadolinium isotopes Gd 154, 155, 156, 157, 158 and 160, the Dysprosium isotopes Dy 162 and 164, the Erbium isotopes Er 166, 168 and 170, the Hafnium isotopes Hf 178 and 180 and the Lead isotopes Pb 204, 206, 207 and 208. A curved crystal Cauchois spectrometer was used. The analysis of the measurement furnished the variation of the mean square charge radius of the nucleus, δ˂r2˃, for 23 isotope pairs. The experimental results were compared with theoretical values from nuclear models. Combining the x-ray shifts and the optical shifts in Nd and Sm yielded the optical mass shifts. An anomaly was observed in the odd-even shifts when the optical and the x-ray shifts were plotted against each other.