972 resultados para vein insufficiency, saphenous vein surgery, duplex study, varicose ulcer.


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The planning of refractive surgical interventions is a challenging task. Numerical modeling has been proposed as a solution to support surgical intervention and predict the visual acuity, but validation on patient specific intervention is missing. The purpose of this study was to validate the numerical predictions of the post-operative corneal topography induced by the incisions required for cataract surgery. The corneal topography of 13 patients was assessed preoperatively and postoperatively (1-day and 30-day follow-up) with a Pentacam tomography device. The preoperatively acquired geometric corneal topography – anterior, posterior and pachymetry data – was used to build patient-specific finite element models. For each patient, the effects of the cataract incisions were simulated numerically and the resulting corneal surfaces were compared to the clinical postoperative measurements at one day and at 30-days follow up. Results showed that the model was able to reproduce experimental measurements with an error on the surgically induced sphere of 0.38D one day postoperatively and 0.19D 30 days postoperatively. The standard deviation of the surgically induced cylinder was 0.54D at the first postoperative day and 0.38D 30 days postoperatively. The prediction errors in surface elevation and curvature were below the topography measurement device accuracy of ±5μm and ±0.25D after the 30-day follow-up. The results showed that finite element simulations of corneal biomechanics are able to predict post cataract surgery within topography measurement device accuracy. We can conclude that the numerical simulation can become a valuable tool to plan corneal incisions in cataract surgery and other ophthalmosurgical procedures in order to optimize patients' refractive outcome and visual function.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

What's known on the subject? and What does the study add? The EndoSew® prototype was first tested in a porcine model several years ago. The investigators found it both simple to master and reliable, its greatest advantage being a 2.4-fold time saving compared with straight laparoscopic suturing. In addition to that publication, there is a single case report describing the performance of an open EndoSew® suture to close parts (16 cm) of an ileal neobladder. The time for suturing the 16 cm ileum was 25 min, which is in line with our experience. The knowledge on this subject is limited to these two publications. We report on the first consecutive series of ileal conduits performed in humans using the novel prototype sewing device EndoSew®. The study shows that the beginning and the end of the suture process represent the critical procedural steps. It also shows that, overall, the prototype sewing machine has the potential to facilitate the intracorporeal suturing required in reconstructive urology for construction of urinary diversions. Objective To evaluate the feasibility and safety of the novel prototype sewing device EndoSew® in placing an extracorporeal resorbable running suture for ileal conduits. Patients and Methods We conducted a prospective single-centre pilot study of 10 consecutive patients undergoing ileal conduit, in whom the proximal end of the ileal conduit was closed extracorporeally using an EndoSew® running suture. The primary endpoint was the safety of the device and the feasibility of the sewing procedure which was defined as a complete watertight running suture line accomplished by EndoSew® only. Watertightness was assessed using methylene blue intraoperatively and by loopography on postoperative days 7 and 14. Secondary endpoints were the time requirements and complications ≤30 days after surgery. Results A complete EndoSew® running suture was feasible in nine patients; the suture had to be abandoned in one patient because of mechanical failure. In three patients, two additional single freehand stitches were needed to anchor the thread and to seal tiny leaks. Consequently, all suture lines in 6/10 patients were watertight with EndoSew® suturing alone and in 10/10 patients after additional freehand stitches. The median (range) sewing time was 5.5 (3–10) min and the median (range) suture length was 4.5 (2–5.5) cm. There were no suture-related complications. Conclusions The EndoSew® procedure is both feasible and safe. After additional freehand stitches in four patients all sutures were watertight. With further technical refinements, EndoSew® has the potential to facilitate the intracorporeal construction of urinary diversions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Today’s medical devices are powered by batteries with a limited energy storage capacity. Depleted batteries have to be replaced, exposing the patients to the risk of adverse events. Thus, a method for harvesting energy inside the body is desirable since it would allow building devices without batteries. Methods: A miniaturized intravascular Tesla turbine was implanted as an arteriovenous shunt between the common carotid artery and external jugular vein of a pig. The harvested energy was used to power a custom-built temporary cardiac pacemaker. Results: At a flow rate of ~150 ml/min, an output power of 0.4 mW was measured. Successful ventricular pacing was performed. Conclusion: Harvesting energy from the circulation using an intravascular turbine is technically feasible and provides enough energy to power a cardiac pacemaker.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Omentin is a visceral fat-derived adipokine associated with endothelium-dependent vasodilation. Impaired endothelial function is a major cause of portal hypertension in liver cirrhosis. The aim was to assess associations of omentin with systemic markers of endothelial function, namely arginine and asymmetric dimethylarginine (ADMA) and complications of portal hypertension in liver cirrhosis. MATERIALS AND METHODS: Systemic omentin was measured by ELISA in portal venous serum (PVS), systemic venous serum (SVS) and hepatic venous serum (HVS) of 40 patients with liver cirrhosis and 10 liver-healthy controls. ADMA and arginine were determined in SVS of the patients by ELISA. RESULTS: Omentin is elevated in PVS and tends to be increased in SVS and HVS of patients with liver cirrhosis compared with controls. Omentin is principally expressed in visceral fat, and PVS omentin tends to be higher than SVS levels. Lower HVS than PVS omentin suggests that omentin may be partly removed from the circulation by the liver. Omentin in serum is not associated with stages of liver cirrhosis defined by CHILD-POUGH or MELD score and is not affected in patients with ascites. HVS omentin tends to be reduced in patients with large varices compared with patients without/with small varices. Arginine/ADMA ratio is reduced in patients with massive ascites but is not associated with variceal size. Further, Arginine/ADMA ratio does not correlate with omentin. CONCLUSION: Current data show that PVS omentin is increased in liver cirrhosis but is not associated with complications of portal hypertension

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE The aim of the study was to describe the (a) symptom experience of women with vulvar intraepithelial neoplasia and vulvar cancer (vulvar neoplasia) during the first week after hospital discharge, and (b) associations between age, type of disease, stage of disease, the extent of surgical treatment and symptom experience. METHODS This cross-sectional study was conducted in eight hospitals in Germany and Switzerland (Clinical Trial ID: NCT01300663). Symptom experience after surgical treatment in women with vulvar neoplasia was measured with our newly developed WOMAN-PRO instrument. Outpatients (n=65) rated 31 items. We used descriptive statistics and regression analysis. RESULTS The average number of symptoms reported per patient was 20.2 (SD 5.77) with a range of 5 to 31 symptoms. The three most prevalent wound-related symptoms were 'swelling' (n=56), 'drainage' (n=54) and 'pain' (n=52). The three most prevalent difficulties in daily life were 'sitting' (n=63), 'wearing clothes' (n=56) and 'carrying out my daily activities' (n=51). 'Tiredness' (n=62), 'insecurity' (n=54) and 'feeling that my body has changed' (n=50) were the three most prevalent psychosocial symptoms/issues. The most distressing symptoms were 'sitting' (Mean 2.03, SD 0.88), 'open spot (e.g. opening of skin or suture)' (Mean 1.91, SD 0.93), and 'carrying out my daily activities' (Mean 1.86, SD 0.87), which were on average reported as 'quite a bit' distressing. Negative associations were found between psychosocial symptom experience and age. CONCLUSIONS WOMAN-PRO data showed a high symptom prevalence and distress, call for a comprehensive symptom assessment, and may allow identification of relevant areas in symptom management.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Single procedure success rates of pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF) are still unsatisfactory. In patients with persistent atrial fibrillation (AF), ablation of complex fractionated atrial electrograms (CFAEs) after PVI results in improved outcomes. Objective We aimed to investigate if PAF-patients with intraprocedurally sustained AF after PVI might benefit from additional CFAE ablation. Methods A total of 1134 consecutive patients underwent a first catheter ablation procedure of PAF between June 2008 and December 2012. In most patients, AF was either not inducible or terminated during PVI. In 68 patients (6%), AF sustained after successful PVI. These patients were randomized to either cardioversion (PVI-alone group; n = 33) or additional CFAE ablation (PVI+CFAE group; n = 35) and followed up every 1–3 months and serial Holter recordings were also obtained. The primary end point was the recurrence of AF/atrial tachycardia (AT) after a blanking period of 3 months. Results Procedure duration (127 ± 6 minutes vs 174 ± 10 minutes), radiofrequency application time (44 ± 3 minutes vs 74 ± 5 minutes), and fluoroscopy time (26 ± 2 minutes vs 41 ± 3 minutes) were longer in the PVI+CFAE group (all P < .001). In 30 of 35 patients (86%) in the PVI+CFAE group, ablation terminated AF. There was no significant group difference with respect to freedom from AF/AT (22 of 33 [67%] vs 22 of 35 [63%]; P = .66). Subsequently, 10 of 11 patients in the PVI-alone group (91%) and 11 of 13 patients in PVI+CFAE group (85%) underwent repeat ablation (P = 1.00). Overall, 29 of 33 [88%] vs 30 of 35 [86%] patients (P = 1.00) were free from AF/AT after 1.4 ± 0.1 vs 1.4 ± 0.2 (P = .87) procedures. Conclusion Patients with sustained AF after PVI in a PAF cohort are rare. Regarding AF/AT recurrence, these patients did not benefit from further CFAE ablation compared to PVI alone, but are exposed to longer procedure duration, fluoroscopy time, and radiofrequency application time.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE The purpose of this study was to evaluate the prevalence of mesenteric venous thrombosis (MVT) in the Swiss Inflammatory Bowel Disease Cohort Study and to correlate MVT with clinical outcome. MATERIALS AND METHODS Abdominal portal phase CT was used to examine patients with inflammatory bowel disease (IBD). Two experienced abdominal radiologists retrospectively analyzed the images, focusing on the superior and inferior mesenteric vein branches and looking for signs of acute or chronic thrombosis. The location of abnormalities was registered. The presence of MVT was correlated with IBD-related radiologic signs and complications. RESULTS The cases of 160 patients with IBD (89 women, 71 men; Crohn disease [CD], 121 patients; ulcerative colitis [UC], 39 patients; median age at diagnosis, 27 years for patients with CD, 32 years for patients with UC) were analyzed. MVT was detected in 43 patients with IBD (26.8%). One of these patients had acute MVT; 38, chronic MVT; and four, both. The prevalence of MVT did not differ between CD (35/121 [28.9%]) and UC (8/39 [20.5%]) (p = 0.303). The location of thrombosis was different between CD and UC (CD, jejunal or ileal veins only [p = 0.005]; UC, rectocolic veins only [p = 0.001]). Almost all (41/43) cases of thrombosis were peripheral. MVT in CD patients was more frequently associated with bowel wall thickening (p = 0.013), mesenteric fat hypertrophy (p = 0.005), ascites (p = 0.002), and mesenteric lymph node enlargement (p = 0.036) and was associated with higher rate of bowel stenosis (p < 0.001) and more intestinal IBD-related surgery (p = 0.016) in the outcome. Statistical analyses for patients with UC were not relevant because of the limited population (n = 8). CONCLUSION MVT is frequently found in patients with IBD. Among patients with CD, MVT is associated with bowel stenosis and CD-related intestinal surgery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND For patients with acute iliofemoral deep vein thrombosis, it remains unclear whether the addition of intravascular high-frequency, low-power ultrasound energy facilitates the resolution of thrombosis during catheter-directed thrombolysis. METHODS AND RESULTS In a controlled clinical trial, 48 patients (mean age 50±21 years, 52% women) with acute iliofemoral deep vein thrombosis were randomized to receive ultrasound-assisted catheter-directed thrombolysis (N=24) or conventional catheter-directed thrombolysis (N=24). Thrombolysis regimen (20 mg r-tPA over 15 hours) was identical in all patients. The primary efficacy end point was the percentage of thrombus load reduction from baseline to 15 hours according to the length-adjusted thrombus score, obtained from standardized venograms and evaluated by a core laboratory blinded to group assignment. The percentage of thrombus load reduction was 55%±27% in the ultrasound-assisted catheter-directed thrombolysis group and 54%±27% in the conventional catheter-directed thrombolysis group (P=0.91). Adjunctive angioplasty and stenting was performed in 19 (80%) patients and in 20 (83%) patients, respectively (P>0.99). Treatment-related complications occurred in 3 (12%) and 2 (8%) patients, respectively (P>0.99). At 3-month follow-up, primary venous patency was 100% in the ultrasound-assisted catheter-directed thrombolysis group and 96% in the conventional catheter-directed thrombolysis group (P=0.33), and there was no difference in the severity of the post-thrombotic syndrome (mean Villalta score: 3.0±3.9 [range 0-15] versus 1.9±1.9 [range 0-7]; P=0.21), respectively. CONCLUSIONS In this randomized controlled clinical trial of patients with acute iliofemoral deep vein thrombosis treated with a fixed-dose catheter thrombolysis regimen, the addition of intravascular ultrasound did not facilitate thrombus resolution. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01482273.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Antifibrinolytics have been used for 2 decades to reduce bleeding in cardiac surgery. MDCO-2010 is a novel, synthetic, serine protease inhibitor. We describe the first experience with this drug in patients. METHODS In this phase II, double-blind, placebo-controlled study, 32 patients undergoing isolated primary coronary artery bypass grafting with cardiopulmonary bypass were randomly assigned to 1 of 5 increasing dosage groups of MDCO-2010. The primary aim was to evaluate pharmacokinetics (PK) with assessment of plasmatic concentrations of the drug, short-term safety, and tolerance of MDCO-2010. Secondary end points were influence on coagulation, chest tube drainage, and transfusion requirements. RESULTS PK analysis showed linear dosage-proportional correlation between MDCO-2010 infusion rate and PK parameters. Blood loss was significantly reduced in the 3 highest dosage groups compared with control (P = 0.002, 0.004 and 0.011, respectively). The incidence of allogeneic blood product transfusions was lower with MDCO-2010 4/24 (17%) vs 4/8 (50%) in the control group. MDCO-2010 exhibited dosage-dependent antifibrinolytic effects through suppression of D-dimer generation and inhibition of tissue plasminogen activator-induced lysis in ROTEM analysis as well as anticoagulant effects demonstrated by prolongation of activated clotting time and activated partial thromboplastin time. No systematic differences in markers of end organ function were observed among treatment groups. Three patients in the MDCO-2010 groups experienced serious adverse events. One patient experienced intraoperative thrombosis of venous grafts considered possibly related to the study drug. No reexploration for mediastinal bleeding was required, and there were no deaths. CONCLUSIONS This first-in-patient study demonstrated dosage-proportional PK for MDCO-2010 and reduction of chest tube drainage and transfusions in patients undergoing primary coronary artery bypass grafting. Antifibrinolytic and anticoagulant effects were demonstrated using various markers of coagulation. MDCO-2010 was well tolerated and showed an acceptable initial safety profile. Larger multi-institutional studies are warranted to further investigate the safety and efficacy of this compound.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the prevalence of discontinuation and nonpublication of surgical versus medical randomized controlled trials (RCTs) and to explore risk factors for discontinuation and nonpublication of surgical RCTs. BACKGROUND: Trial discontinuation has significant scientific, ethical, and economic implications. To date, the prevalence of discontinuation of surgical RCTs is unknown. METHODS: All RCT protocols approved between 2000 and 2003 by 6 ethics committees in Canada, Germany, and Switzerland were screened. Baseline characteristics were collected and, if published, full reports retrieved. Risk factors for early discontinuation for slow recruitment and nonpublication were explored using multivariable logistic regression analyses. RESULTS: In total, 863 RCT protocols involving adult patients were identified, 127 in surgery (15%) and 736 in medicine (85%). Surgical trials were discontinued for any reason more often than medical trials [43% vs 27%, risk difference 16% (95% confidence interval [CI]: 5%-26%); P = 0.001] and more often discontinued for slow recruitment [18% vs 11%, risk difference 8% (95% CI: 0.1%-16%); P = 0.020]. The percentage of trials not published as full journal article was similar in surgical and medical trials (44% vs 40%, risk difference 4% (95% CI: -5% to 14%); P = 0.373). Discontinuation of surgical trials was a strong risk factor for nonpublication (odds ratio = 4.18, 95% CI: 1.45-12.06; P = 0.008). CONCLUSIONS: Discontinuation and nonpublication rates were substantial in surgical RCTs and trial discontinuation was strongly associated with nonpublication. These findings need to be taken into account when interpreting surgical literature. Surgical trialists should consider feasibility studies before embarking on full-scale trials.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND During 2007 and 2008 it is likely that millions of patients in the US received heparin contaminated (CH) with oversulfated chondroitin sulfate, which was associated with anaphylactoid reactions. We tested the hypothesis that CH was associated with serious morbidity, mortality, intensive care unit (ICU) stay and heparin-induced thrombocytopenia following adult cardiac surgery. METHODS AND FINDINGS We conducted a single center, retrospective, propensity-matched cohort study during the period of CH and the equivalent time frame in the three preceding or the two following years. Perioperative data were obtained from the institutional record of the Society of Thoracic Surgeons National Database, for which the data collection is prospective, standardized and performed by independent investigators. After matching, logistic regression was performed to evaluate the independent effect of CH on the composite adverse outcome (myocardial infarction, stroke, pneumonia, dialysis, cardiac arrest) and on mortality. Cox regression was used to determine the association between CH and ICU length of stay. The 1∶5 matched groups included 220 patients potentially exposed to CH and 918 controls. There were more adverse outcomes in the exposed cohort (20.9% versus 12.0%; difference  =  8.9%; 95% CI 3.6% to 15.1%, P < 0.001) with an odds ratio for CH of 2.0 (95% CI, 1.4 to 3.0, P < 0.001). In the exposed group there was a non-significant increase in mortality (5.9% versus 3.5%, difference = 2.4%; 95% CI, -0.4 to 3.5%, P  =  0.1), the median ICU stay was longer by 14.1 hours (interquartile range -26.6 to 79.8, S = 3299, P = 0.0004) with an estimated hazard ratio for CH of 1.2 (95% CI, 1.0 to 1.4, P = 0.04). There was no difference in nadir platelet counts between cohorts. CONCLUSIONS The results from this single center study suggest the possibility that contaminated heparin might have contributed to serious morbidity following cardiac surgery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE Assessment of the cerebral blood flow (CBF) is crucial in the evaluation of patients with steno-occlusive diseases of the arteries supplying the brain for prediction of stroke risk. Quantitative phase contrast magnetic resonance angiography (PC-MRA) can be utilised for noninvasive quantification of CBF. The aim of this study was to validate in-vivo PC-MRA data by comparing them with colour-coded duplex (CCD) sonography in patients with cerebrovascular disease. METHODS AND MATERIALS We examined 24 consecutive patients (mean age 63 years) with stenosis of arteries supplying the brain using PC-MRA and CCD. Velocities were measured in a total of 209 stenotic and healthy arterial segments (110 extra- and 99 intracranial). RESULTS Moderate to good correlation of velocity measurements between both techniques was observed in all six extracranial and five out of seven intracranial segments (p <0.05). Velocities measured with CCD sonography were generally higher than those obtained by PC-MRA. Reversal of flow direction was detected consistently with both methods. CONCLUSION PC-MRA represents a robust, standardised magnetic resonance imaging technique for blood flow measurements within a reasonable acquisition time, potentially evolving as valuable work-up tool for more precise patient stratification for revascularisation therapy. PC-MRA overcomes relevant weaknesses of CCD in being not operator-dependent and not relying on a bone window to assess the intracranial arteries.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Sutureless aortic valve replacement (SU-AVR) is an innovative approach which shortens cardiopulmonary bypass and cross-clamp durations and may facilitate minimally invasive approach. Evidence outlining its safety, efficacy, hemodynamic profile and potential complications is replete with small-volume observational studies and few comparative publications. METHODS Minimally invasive aortic valve surgery and high-volume SU-AVR replacement centers were contacted for recruitment into a global collaborative coalition dedicated to sutureless valve research. A Research Steering Committee was formulated to direct research and support the mission of providing registry evidence warranted for SU-AVR. RESULTS The International Valvular Surgery Study Group (IVSSG) was formed under the auspices of the Research Steering Committee, comprised of 36 expert valvular surgeons from 27 major centers across the globe. IVSSG Sutureless Projects currently proceeding include the Retrospective and Prospective Phases of the SU-AVR International Registry (SU-AVR-IR). CONCLUSIONS The global pooling of data by the IVSSG Sutureless Projects will provide required robust clinical evidence on the safety, efficacy and hemodynamic outcomes of SU-AVR.