994 resultados para user testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a result of the collapse of a 140 foot high-mast lighting tower in Sioux City, Iowa in November of 2003, a thorough investigation into the behavior and design of these tall, yet relatively flexible structures was undertaken. Extensive work regarding the root cause of this failure was carried out by Robert Dexter of The University of Minnesota. Furthermore, a statewide inspection of all the high-mast towers in Iowa revealed fatigue cracks and loose anchor bolts on other existing structures. The current study was proposed to examine the static and dynamic behavior of a variety of towers in the State of Iowa utilizing field testing, specifically long-term monitoring and load testing. This report presents the results and conclusions from this project. The field work for this project was divided into two phases. Phase 1 of the project was conducted in October 2004 and focused on the dynamic properties of ten different towers in Clear Lake, Ames, and Des Moines, Iowa. Of those ten, two were also instrumented to obtain stress distributions at various details and were included in a 12 month long-term monitoring study. Phase 2 of this investigation was conducted in May of 2005, in Sioux City, Iowa, and focused on determining the static and dynamic behavior of a tower similar to the one that collapsed in November 2003. Identical tests were performed on a similar tower which was retrofitted with a more substantial replacement bottom section in order to assess the effect of the retrofit. A third tower with different details was dynamically load tested to determine its dynamic characteristics, similar to the Phase 1 testing. Based on the dynamic load tests, the modal frequencies of the towers fall within the same range. Also, the damping ratios are significantly lower in the higher modes than the values suggested in the AASHTO and CAN/CSA specifications. The comparatively higher damping ratios in the first mode may be due to aerodynamic damping. These low damping ratios in combination with poor fatigue details contribute to the accumulation of a large number of damage-causing cycles. As predicted, the stresses in the original Sioux City tower are much greater than the stresses in the retrofitted towers at Sioux City. Additionally, it was found that poor installation practices which often lead to loose anchor bolts and out-of-level leveling nuts can cause high localized stresses in the towers, which can accelerate fatigue damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study was initiated to quantify the stresses induced in critical details on the reinforcing jacket and the tower itself through the use of field instrumentation, load testing, and long-term monitoring. Strain gages were installed on the both the tower and the reinforcing jacket. Additional strain gages were installed on two anchor rods. Tests were conducted with and without the reinforcing jacket installed. Data were collected from all strain gages during static load testing and were used to study the stress distribution of the tower caused by known loads, both with and without the reinforcing jacket. The tower was tested dynamically by first applying a static load, and then quickly releasing the load causing the tower to vibrate freely. Furthermore, the tower was monitored over a period of over 1 year to obtain stress range histograms at the critical details to be used for a fatigue evaluation. Also during the long-term monitoring, triggered time-history data were recorded to study the wind loading phenomena that excite the tower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In response to the mandate on Load and Resistance Factor Design (LRFD) implementations by the Federal Highway Administration (FHWA) on all new bridge projects initiated after October 1, 2007, the Iowa Highway Research Board (IHRB) sponsored these research projects to develop regional LRFD recommendations. The LRFD development was performed using the Iowa Department of Transportation (DOT) Pile Load Test database (PILOT). To increase the data points for LRFD development, develop LRFD recommendations for dynamic methods, and validate the results of LRFD calibration, 10 full-scale field tests on the most commonly used steel H-piles (e.g., HP 10 x 42) were conducted throughout Iowa. Detailed in situ soil investigations were carried out, push-in pressure cells were installed, and laboratory soil tests were performed. Pile responses during driving, at the end of driving (EOD), and at re-strikes were monitored using the Pile Driving Analyzer (PDA), following with the CAse Pile Wave Analysis Program (CAPWAP) analysis. The hammer blow counts were recorded for Wave Equation Analysis Program (WEAP) and dynamic formulas. Static load tests (SLTs) were performed and the pile capacities were determined based on the Davisson’s criteria. The extensive experimental research studies generated important data for analytical and computational investigations. The SLT measured load-displacements were compared with the simulated results obtained using a model of the TZPILE program and using the modified borehole shear test method. Two analytical pile setup quantification methods, in terms of soil properties, were developed and validated. A new calibration procedure was developed to incorporate pile setup into LRFD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two portable Radio Frequency IDentification (RFID) systems (made by Texas Instruments and HiTAG) were developed and tested for bridge scour monitoring by the Department of Civil and Environmental Engineering at the University of Iowa (UI). Both systems consist of three similar components: 1) a passive cylindrical transponder of 2.2 cm in length (derived from transmitter/responder); 2) a low frequency reader (~134.2 kHz frequency); and 3) an antenna (of rectangular or hexagonal loop). The Texas Instruments system can only read one smart particle per time, while the HiTAG system was successfully modified here at UI by adding the anti-collision feature. The HiTAG system was equipped with four antennas and could simultaneously detect 1,000s of smart particles located in a close proximity. A computer code was written in C++ at the UI for the HiTAG system to allow simultaneous, multiple readouts of smart particles under different flow conditions. The code is written for the Windows XP operational system which has a user-friendly windows interface that provides detailed information regarding the smart particle that includes: identification number, location (orientation in x,y,z), and the instance the particle was detected.. These systems were examined within the context of this innovative research in order to identify the best suited RFID system for performing autonomous bridge scour monitoring. A comprehensive laboratory study that included 142 experimental runs and limited field testing was performed to test the code and determine the performance of each system in terms of transponder orientation, transponder housing material, maximum antenna-transponder detection distance, minimum inter-particle distance and antenna sweep angle. The two RFID systems capabilities to predict scour depth were also examined using pier models. The findings can be summarized as follows: 1) The first system (Texas Instruments) read one smart particle per time, and its effective read range was about 3ft (~1m). The second system (HiTAG) had similar detection ranges but permitted the addition of an anti-collision system to facilitate the simultaneous identification of multiple smart particles (transponders placed into marbles). Therefore, it was sought that the HiTAG system, with the anti-collision feature (or a system with similar features), would be preferable when compared to a single-read-out system for bridge scour monitoring, as the former could provide repetitive readings at multiple locations, which could help in predicting the scour-hole bathymetry along with maximum scour depth. 2) The HiTAG system provided reliable measures of the scour depth (z-direction) and the locations of the smart particles on the x-y plane within a distance of about 3ft (~1m) from the 4 antennas. A Multiplexer HTM4-I allowed the simultaneous use of four antennas for the HiTAG system. The four Hexagonal Loop antennas permitted the complete identification of the smart particles in an x, y, z orthogonal system as function of time. The HiTAG system can be also used to measure the rate of sediment movement (in kg/s or tones/hr). 3) The maximum detection distance of the antenna did not change significantly for the buried particles compared to the particles tested in the air. Thus, the low frequency RFID systems (~134.2 kHz) are appropriate for monitoring bridge scour because their waves can penetrate water and sand bodies without significant loss of their signal strength. 4) The pier model experiments in a flume with first RFID system showed that the system was able to successfully predict the maximum scour depth when the system was used with a single particle in the vicinity of pier model where scour-hole was expected. The pier model experiments with the second RFID system, performed in a sandbox, showed that system was able to successfully predict the maximum scour depth when two scour balls were used in the vicinity of the pier model where scour-hole was developed. 5) The preliminary field experiments with the second RFID system, at the Raccoon River, IA near the Railroad Bridge (located upstream of 360th street Bridge, near Booneville), showed that the RFID technology is transferable to the field. A practical method would be developed for facilitating the placement of the smart particles within the river bed. This method needs to be straightforward for the Department of Transportation (DOT) and county road working crews so it can be easily implemented at different locations. 6) Since the inception of this project, further research showed that there is significant progress in RFID technology. This includes the availability of waterproof RFID systems with passive or active transponders of detection ranges up to 60 ft (~20 m) within the water–sediment column. These systems do have anti-collision and can facilitate up to 8 powerful antennas which can significantly increase the detection range. Such systems need to be further considered and modified for performing automatic bridge scour monitoring. The knowledge gained from the two systems, including the software, needs to be adapted to the new systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This manual describes how to use the Iowa Bridge Backwater software. It also documents the methods and equations used for the calculations. The main body describes how to use the software and the appendices cover technical aspects. The Bridge Backwater software performs 5 main tasks: Design Discharge Estimation; Stream Rating Curves; Floodway Encroachment; Bridge Backwater; and Bridge Scour. The intent of this program is to provide a simplified method for analysis of bridge backwater for rural structures located in areas with low flood damage potential. The software is written in Microsoft Visual Basic 6.0. It will run under Windows 95 or newer versions (i.e. Windows 98, NT, 2000, XP and later).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Iowa Pore Index (IPI) measures the pore system of carbonate (limestone and dolomite) rocks using pressurized water to infiltrate the pore system. This technique provides quantitative results for the primary and capillary (secondary) pores in carbonate rocks. These results are used in conjunction with chemical and mineralogical test results to calculate a quality number, which is used as a predictor of aggregate performance in Portland cement concrete (PCC) leading to the durability classification of the aggregate. This study had two main objectives: to determine the effect different aggregate size has on IPI test results and to establish the precision of IPI test and test apparatus. It was found that smaller aggregate size fractions could be correlated to the standard 1/2”-3/4” size sample. Generally, a particle size decrease was accompanied by a slight decrease in IPI values. The IPI testing also showed fairly good agreement of the secondary pore index number between the 1/2”-3/4”and the 3/8”-1/2” fraction. The #4-3/8” showed a greater difference of the secondary number from the 1/2”-3/4” fraction. The precision of the IPI test was established as a standard deviation (Sr) of 2.85 (Primary) and 0.87 (Secondary) with a repeatability limit (%r) of 8.5% and 14.9% for the primary and secondary values, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many patients with malignant gliomas do not respond to alkylating agent chemotherapy. Alkylator resistance of glioma cells is mainly mediated by the DNA repair enzyme O(6)-methylguanine-DNA methyltransferase (MGMT). Epigenetic silencing of the MGMT gene by promoter methylation in glioma cells compromises this DNA repair mechanism and increases chemosensitivity. MGMT promoter methylation is, therefore, a strong prognostic biomarker in paediatric and adult patients with glioblastoma treated with temozolomide. Notably, elderly patients (>65-70 years) with glioblastoma whose tumours lack MGMT promoter methylation derive minimal benefit from such chemotherapy. Thus, MGMT promoter methylation status has become a frequently requested laboratory test in neuro-oncology. This Review presents current data on the prognostic and predictive relevance of MGMT testing, discusses clinical trials that have used MGMT status to select participants, evaluates known issues concerning the molecular testing procedure, and addresses the necessity for molecular-context-dependent interpretation of MGMT test results. Whether MGMT promoter methylation testing should be offered to all individuals with glioblastoma, or only to elderly patients and those in clinical trials, is also discussed. Justifications for withholding alkylating agent chemotherapy in patients with MGMT-unmethylated glioblastomas outside clinical trials, and the potential role for MGMT testing in other gliomas, are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine 1) HIV testing practices in a 1400-bed university hospital where local HIV prevalence is 0.4% and 2) the effect on testing practices of national HIV testing guidelines, revised in March 2010, recommending Physician-Initiated Counselling and Testing (PICT). METHODS: Using 2 hospital databases, we determined the number of HIV tests performed by selected clinical services, and the number of patients tested as a percentage of the number seen per service ('testing rate'). To explore the effect of the revised national guidelines, we examined testing rates for two years pre- and two years post-PICT guideline publication. RESULTS: Combining the clinical services, 253,178 patients were seen and 9,183 tests were performed (of which 80 tested positive, 0.9%) in the four-year study period. The emergency department (ED) performed the second highest number of tests, but had the lowest testing rates (0.9-1.1%). Of inpatient services, neurology and psychiatry had higher testing rates than internal medicine (19.7% and 9.6% versus 8%, respectively). There was no significant increase in testing rates, either globally or in the majority of the clinical services examined, and no increase in new HIV diagnoses post-PICT recommendations. CONCLUSIONS: Using a simple two-database tool, we observe no global improvement in HIV testing rates in our hospital following new national guidelines but do identify services where testing practices merit improvement. This study may show the limit of PICT strategies based on physician risk assessment, compared to the opt-out approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Platelet P2YI2 receptor inhibition with clopidogrel, prasugrel or ticagrelor plays a key role to prevent recurrent ischaemic events after percutaneous coronary intervention in acute coronary syndromes or elective settings. The degree of platelet inhibition depends on the antiplatelet medication used and is influenced by clinical and genetic factors. A concept of therapeutic window exists. On one side, efficient anti-aggregation is required in order to reduce cardio-vascular events. On the other side, an excessive platelet inhibition represents a risk of bleeding complications. This article describes the current knowledge about some platelet function tests and genetic tests and summarises their role in the clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integral abutment bridges are constructed without an expansion joint in the superstructure of the bridge; therefore, the bridge girders, deck, abutment diaphragms, and abutments are monolithically constructed. The abutment piles in an integral abutment bridge are vertically orientated, and they are embedded into the pile cap. When this type of a bridge experiences thermal expansion or contraction, horizontal displacements are induced at the top of the abutment piles. The flexibility of the abutment piles eliminates the need to provide an expansion joint at the inside face to the abutments: Integral abutment bridge construction has been used in Iowa and other states for many years. This research is evaluating the performance of integral abutment bridges by investigating thermally induced displacements, strains, and temperatures in two Iowa bridges. Each bridge has a skewed alignment, contains five prestressed concrete girders that support a 30-ft wide roadway for three spans, and involves a water crossing. The bridges will be monitored for about two years. For each bridge, an instrumentation package includes measurement devices and hardware and software support systems. The measurement devices are displacement transducers, strain gages, and thermocouples. The hardware and software systems include a data-logger; multiplexers; directline telephone service and computer terminal modem; direct-line electrical power; lap-top computer; and an assortment of computer programs for monitoring, transmitting, and management of the data. Instrumentation has been installed on a bridge located in Guthrie County, and similar instrumentation is currently being installed on a bridge located in Story County. Preliminary test results for the bridge located in Guthrie County have revealed that temperature changes of the bridge deck and girders induce both longitudinal and transverse displacements of the abutments and significant flexural strains in the abutment piles. For an average temperature range of 73° F for the superstructure concrete in the bridge located in Guthrie County, the change in the bridge length was about 1 118 in. and the maximum, strong-axis, flexural-strain range for one of the abutment piles was about 400 micro-strains, which corresponds to a stress range of about 11,600 psi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Randomized, controlled trials have demonstrated efficacy for second-generation antipsychotics in the treatment of acute mania in bipolar disorder. Despite depression being considered the hallmark of bipolar disorder, there are no published systematic reviews or meta-analyses to evaluate the efficacy of modern atypical antipsychotics in bipolar depression. We systematically reviewed published or registered randomized, double-blind, placebo-controlled trials (RCTs) of modern antipsychotics in adult bipolar I and/or II depressive patients (DSM-IV criteria). Efficacy outcomes were assessed based on changes in the Montgomery-Asberg Depression Rating Scale (MADRS) during an 8-wk period. Data were combined through meta-analysis using risk ratio as an effect size with a 95% confidence interval (95% CI) and with a level of statistical significance of 5% (p<0.05). We identified five RCTs; four involved antipsychotic monotherapy and one addressed both monotherapy and combination with an antidepressant. The two quetiapine trials analysed the safety and efficacy of two doses: 300 and 600 mg/d. The only olanzapine trial assessed olanzapine monotherapy within a range of 5-20 mg/d and olanzapine-fluoxetine combination within a range of 5-20 mg/d and 6-12 mg/d, respectively. The two aripiprazole placebo-controlled trials assessed doses of 5-30 mg/d. Quetiapine and olanzapine trials (3/5, 60%) demonstrated superiority over placebo (p<0.001). Only 2/5 (40%) (both aripiprazole trials) failed in the primary efficacy measure after the first 6 wk. Some modern antipsychotics (quetiapine and olanzapine) have demonstrated efficacy in bipolar depressive patients from week 1 onwards. Rapid onset of action seems to be a common feature of atypical antipsychotics in bipolar depression. Comment in The following popper user interface control may not be accessible. Tab to the next button to revert the control to an accessible version.Destroy user interface controlEfficacy of modern antipsychotics in placebo-controlled trials in bipolar depression: a meta-analysis--results to be interpreted with caution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanotechnology has been heralded as a "revolution" in science, for two reasons: first, because of its revolutionary view of the way in which chemicals and elements, such as gold and silver, behave, compared to traditional scientific understanding of their properties. Second, the impact of these new discoveries, as applied to commerce, can transform the daily life of consumer products ranging from sun tan lotions and cosmetics, food packaging and paints and coatings for cars, housing and fabrics, medicine and thousands of industrial processes.9 Beneficial consumer use of nanotechnologies, already in the stream of commerce, improves coatings on inks and paints in everything from food packaging to cars. Additionally, "Nanomedicine" offers the promise of diagnosis and treatment at the molecular level in order to detect and treat presymptomatic disease,10 or to rebuild neurons in Alzheimer's and Parkinson's disease. There is a possibility that severe complications such as stroke or heart attack may be avoided by means of prophylactic treatment of people at risk, and bone regeneration may keep many people active who never expected rehabilitation. Miniaturisation of diagnostic equipment can also reduce the amount of sampling materials required for testing and medical surveillance. Miraculous developments, that sound like science fiction to those people who eagerly anticipate these medical products, combined with the emerging commercial impact of nanotechnology applications to consumer products will reshape civil society - permanently. Thus, everyone within the jurisdiction of the Council of Europe is an end-user of nanotechnology, even without realising that nanotechnology has touched daily life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine the power of different exact tests of differentiation for diploid populations. Since there is not necessarily random mating within populations, the appropriate hypothesis to construct exact tests is that of independent sampling of genotypes. There are two categories of tests, FST-estimator tests and goodness of fit tests. In this latter category, we distinguish "allelic statistics", which account for the nature of alleles within genotypes, from "genotypic statistics" that do not. We show that the power of FST-estimator tests and of allelic goodness of fit tests are similar when sampling is balanced, and higher than the power of genotypic goodness of fit tests. When sampling is unbalanced, the most powerful tests are shown to belong to the allelic goodness of fit group.