989 resultados para uncertainty estimation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past few decades, age estimation of living persons has represented a challenging task for many forensic services worldwide. In general, the process for age estimation includes the observation of the degree of maturity reached by some physical attributes, such as dentition or several ossification centers. The estimated chronological age or the probability that an individual belongs to a meaningful class of ages is then obtained from the observed degree of maturity by means of various statistical methods. Among these methods, those developed in a Bayesian framework offer to users the possibility of coherently dealing with the uncertainty associated with age estimation and of assessing in a transparent and logical way the probability that an examined individual is younger or older than a given age threshold. Recently, a Bayesian network for age estimation has been presented in scientific literature; this kind of probabilistic graphical tool may facilitate the use of the probabilistic approach. Probabilities of interest in the network are assigned by means of transition analysis, a statistical parametric model, which links the chronological age and the degree of maturity by means of specific regression models, such as logit or probit models. Since different regression models can be employed in transition analysis, the aim of this paper is to study the influence of the model in the classification of individuals. The analysis was performed using a dataset related to the ossifications status of the medial clavicular epiphysis and results support that the classification of individuals is not dependent on the choice of the regression model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most current methods for adult skeletal age-at-death estimation are based on American samples comprising individuals of European and African ancestry. Our limited understanding of population variability hampers our efforts to apply these techniques to various skeletal populations around the world, especially in global forensic contexts. Further, documented skeletal samples are rare, limiting our ability to test our techniques. The objective of this paper is to test three pelvic macroscopic methods (1-Suchey-Brooks; 2- Lovejoy; 3- Buckberry and Chamberlain) on a documented modern Spanish sample. These methods were selected because they are popular among Spanish anthropologists and because they never have been tested in a Spanish sample. The study sample consists of 80 individuals (55 ♂ and 25 ♀) of known sex and age from the Valladolid collection. Results indicate that in all three methods, levels of bias and inaccuracy increase with age. The Lovejoy method performs poorly (27%) compared with Suchey-Brooks (71%) and Buckberry and Chamberlain (86%). However, the levels of correlation between phases and chronological ages are low and comparable in the three methods (< 0.395). The apparent accuracy of the Suchey-Brooks and Buckberry and Chamberlain methods is largely based on the broad width of the methods" estimated intervals. This study suggests that before systematic application of these three methodologies in Spanish populations, further statistical modeling and research into the co-variance of chronological age with morphological change is necessary. Future methods should be developed specific to various world populations, and should allow for both precision and flexibility in age estimation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter presents possible uses and examples of Monte Carlo methods for the evaluation of uncertainties in the field of radionuclide metrology. The method is already well documented in GUM supplement 1, but here we present a more restrictive approach, where the quantities of interest calculated by the Monte Carlo method are estimators of the expectation and standard deviation of the measurand, and the Monte Carlo method is used to propagate the uncertainties of the input parameters through the measurement model. This approach is illustrated by an example of the activity calibration of a 103Pd source by liquid scintillation counting and the calculation of a linear regression on experimental data points. An electronic supplement presents some algorithms which may be used to generate random numbers with various statistical distributions, for the implementation of this Monte Carlo calculation method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses basic theoretical strategies used to deal with measurement uncertainties arising from different experimental situations. It attempts to indicate the most appropriate method of obtaining a reliable estimate of the quantity to be evaluated depending on the characteristics of the data available. The theoretical strategies discussed are supported by experimental detail, and the conditions and results have been taken from examples in the field of radionuclide metrology. Special care regarding the correct treatment of covariances is emphasized because of the unreliability of the results obtained if these are neglected

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to provide an effective and quick reference guide based on the most useful European formulae recently published for subadult age estimation. All of these formulae derive from studies on postnatal growth of the scapula, innominate, femur, and tibia, based on modern skeletal data (173 ♂, 173 ♀) from five documented collections from Spain, Portugal, and Britain. The formulae were calculated from Inverse Regression. For this reason, these formulae are especially useful for modern samples from Western Europe and in particular on 20th century human remains from the Iberian Peninsula. Eleven formulae were selected as the most useful because they can be applied to individuals from within a wide age range and in individuals of unknown sex. Due to their high reliability and because they derive from documented European skeletal samples, we recommend these formulae be used on individuals of Caucasoid ancestry from Western Europe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The -function and the -function are phenomenological models that are widely used in the context of timing interceptive actions and collision avoidance, respectively. Both models were previously considered to be unrelated to each other: is a decreasing function that provides an estimation of time-to-contact (ttc) in the early phase of an object approach; in contrast, has a maximum before ttc. Furthermore, it is not clear how both functions could be implemented at the neuronal level in a biophysically plausible fashion. Here we propose a new framework- the corrected modified Tau function- capable of predicting both -type ("") and -type ("") responses. The outstanding property of our new framework is its resilience to noise. We show that can be derived from a firing rate equation, and, as , serves to describe the response curves of collision sensitive neurons. Furthermore, we show that predicts the psychophysical performance of subjects determining ttc. Our new framework is thus validated successfully against published and novel experimental data. Within the framework, links between -type and -type neurons are established. Therefore, it could possibly serve as a model for explaining the co-occurrence of such neurons in the brain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pressurized re-entrant (or 4 pi) ionization chambers (ICs) connected to current-measuring electronics are used for activity measurements of photon emitting radionuclides and some beta emitters in the fields of metrology and nuclear medicine. As a secondary method, these instruments need to be calibrated with appropriate activity standards from primary or direct standardization. The use of these instruments over 50 years has been well described in numerous publications, such as the Monographie BIPM-4 and the special issue of Metrologia on radionuclide metrology (Ratel 2007 Metrologia 44 S7-16, Schrader1997 Activity Measurements With Ionization Chambers (Monographie BIPM-4) Schrader 2007 Metrologia 44 S53-66, Cox et al 2007 Measurement Modelling of the International Reference System (SIR) for Gamma-Emitting Radionuclides (Monographie BIPM-7)). The present work describes the principles of activity measurements, calibrations, and impurity corrections using pressurized ionization chambers in the first part and the uncertainty analysis illustrated with example uncertainty budgets from routine source-calibration as well as from an international reference system (SIR) measurement in the second part.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The degree of fusion at the anterior aspect of the sacral vertebrae has been scored in 242 male and female skeletons from the Lisbon documented collection, ranging in age from 16 to 59 years old. Statistical tests indicate a sex difference towards earlier fusion in young females compared with young males, as well as a clear association between degree of fusion and age. Similar results have been found in documented skeletal samples from Coimbra and Sassari, and the recommendations stated by these authors regarding age estimation have been positively tested in the Lisbon collection. Although more research from geographically diverse samples is required, a general picture of the pattern of sacral fusion and its associations with age and sex is emerging. We also provide a practical example of the usefulness of the sacrum in age estimation in a forensic setting, a mass grave from the Spanish Civil War. It is concluded that the scoring of the degree of fusion of the sacral vertebrae, specially of S1-2, can be a simple tool for assigning skeletons to broad age groups, and it should be implemented as another resource for age estimation in the study of human skeletal remains.