895 resultados para tourist destination image


Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 20 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 20 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 22 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 20 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 14 x 19 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 10 x 20 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 12 x 20 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ResumoOBJETIVOValidar o instrumento Body Image Relationship Scale (BIRS) em mulheres brasileiras acometidas pelo câncer de mamaMÉTODOSO instrumento foi aplicado por entrevistadoras treinadas em 139 usuárias do Sistema Único de Saúde que foram submetidas aos tratamentos do câncer entre 2006 e 2010. O instrumento foi aferido considerando-se a consistência interna e a confiabilidade. Para efeito de comparação as técnicas de análise fatorial utilizadas no artigo original foram aplicadasRESULTADOSO valor de correlação Spearman-Brown foi 0,8, o que indica alto nível de confiabilidade, e o alfa de Cronbach encontrado foi 0,9, indicando alto nível de consistência interna. A análise fatorial mostrou que quatro questões não tinham poder discriminatório e carga fatorial baixa e outras cinco foram realocadas em outros domínios. Dessa forma, foi aplicada e mostrou variabilidade semelhante ao instrumento originalCONCLUSÃOA versão brasileira do BIRS, renomeada como Escala de Relacionamento e Imagem Corporal (ERIC), apresentou evidências de adequada confiabilidade e consistência interna, o que torna esse instrumento recomendável para aplicação em mulheres brasileiras com câncer de mama, apesar de alguns poucos limites

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Particle Image Velocimetry, PIV, is an optical measuring technique to obtain velocity information of a flow in interest. With PIV it is possible to achieve two or three dimensional velocity vector fields from a measurement area instead of a single point in a flow. Measured flow can be either in liquid or in gas form. PIV is nowadays widely applied to flow field studies. The need for PIV is to obtain validation data for Computational Fluid Dynamics calculation programs that has been used to model blow down experiments in PPOOLEX test facility in the Lappeenranta University of Technology. In this thesis PIV and its theoretical background are presented. All the subsystems that can be considered to be part of a PIV system are presented as well with detail. Emphasis is also put to the mathematics behind the image evaluation. The work also included selection and successful testing of a PIV system, as well as the planning of the installation to the PPOOLEX facility. Already in the preliminary testing PIV was found to be good addition to the measuring equipment for Nuclear Safety Research Unit of LUT. The installation to PPOOLEX facility was successful even though there were many restrictions considering it. All parts of the PIV system worked and they were found out to be appropriate for the planned use. Results and observations presented in this thesis are a good background to further PIV use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fifty Bursa of Fabricius (BF) were examined by conventional optical microscopy and digital images were acquired and processed using Matlab® 6.5 software. The Artificial Neuronal Network (ANN) was generated using Neuroshell® Classifier software and the optical and digital data were compared. The ANN was able to make a comparable classification of digital and optical scores. The use of ANN was able to classify correctly the majority of the follicles, reaching sensibility and specificity of 89% and 96%, respectively. When the follicles were scored and grouped in a binary fashion the sensibility increased to 90% and obtained the maximum value for the specificity of 92%. These results demonstrate that the use of digital image analysis and ANN is a useful tool for the pathological classification of the BF lymphoid depletion. In addition it provides objective results that allow measuring the dimension of the error in the diagnosis and classification therefore making comparison between databases feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trough computed tomography (CT), it is possible to evaluate lymph nodes in detail and to detect changes in these structures earlier than with radiographs and ultrasound. Lack of information in the veterinary literature directed the focus of this report to normal aspects of the axillary and mediastinal lymph nodes of adult dogs on CT imaging. A CT scan of 15 normal adult male and female Rottweilers was done. To define them as clinically sound, anamnesis, physical examination, complete blood count, renal and hepatic biochemistry, ECG, and thoracic radiographs were performed. After the intravenous injection of hydrosoluble ionic iodine contrast medium contiguous 10mm in thickness thoracic transverse images were obtained with an axial scanner. In the obtained images mediastinal and axillary lymph nodes were sought and when found measured in their smallest diameter and their attenuation was compared to musculature. Mean and standard deviation of: age, weight, body length and the smallest diameter of the axillary and mediastinal lymph nodes were determined. Mean and standard deviation of parameters: age 3.87±2.03 years, weight 41.13±5.12, and body length 89.61±2.63cm. Axillary lymph nodes were seen in 60% of the animals, mean of the smallest diameter was 3.58mm with a standard deviation of 2.02 and a minimum value of 1mm and a maximum value of 7mm. From 13 observed lymph nodes 61.53% were hypopodense when compared with musculature, and 30.77% were isodense. Mediastinal lymph nodes were identified in 73.33% of the dogs; mean measure of the smallest diameter was 4.71mm with a standard deviation of 2.61mm and a minimum value of 1mm, and a maximum value of 8mm. From 14 observed lymph nodes 85.71% were isodense when compared with musculature and 14.28% were hypodense. The results show that it is possible to visualize axillary and mediastinal lymph nodes in adult clinically sound Rottweilers with CT using a slice thickness and interval of 10mm. The smallest diameter of the axillary and mediastinal lymph nodes not surpassed 7mm and 8mm respectively. Their attenuations were equal or smaller than that of musculature in the post contrast scan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Shadow Moiré fringe patterns are level lines of equal depth generated by interference between a master grid and its shadow projected on the surface. In simplistic approach, the minimum error is about the order of the master grid pitch, that is, always larger than 0,1 mm, resulting in an experimental technique of low precision. The use of a phase shift increases the accuracy of the Shadow Moiré technique. The current work uses the phase shifting method to determine the surfaces three-dimensional shape using isothamic fringe patterns and digital image processing. The current study presents the method and applies it to images obtained by simulation for error evaluation, as well as to a buckled plate, obtaining excellent results. The method hands itself particularly useful to decrease the errors in the interpretation of the Moiré fringes that can adversely affect the calculations of displacements in pieces containing many concave and convex regions in relatively small areas.