955 resultados para stiffness tomography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Minor brain injury is a frequent condition. Validated clinical decision rules can help in deciding whether a computed tomogram (CT) of the head is required. We hypothesized that institutional guidelines are not frequently used, and that psychological factors are a common reason for ordering an unnecessary CT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare inter-observer agreement of Stratus™ OCT versus Spectralis™ OCT image grading in patients with neovascular age-related macular degeneration (AMD). Thirty eyes with neovascular AMD were examined with Stratus™ OCT and Spectralis™ OCT. Four different scan protocols were used for imaging. Three observers graded the images for the presence of various pathologies. Inter-observer agreement between OCT models was assessed by calculating intra-class correlation coefficients (ICC). In Stratus™ OCT highest interobserver agreement was found for subretinal fluid (ICC: 0.79), and in Spectralis™ OCT for intraretinal cysts (IRC) (ICC: 0.93). Spectralis™ OCT showed superior interobserver agreement for IRC and epiretinal membranes (ERM) (ICC(Stratus™): for IRC 0.61; for ERM 0.56; ICC(Spectralis™): for IRC 0.93; for ERM 0.84). Increased image resolution of Spectralis™ OCT did improve the inter-observer agreement for grading intraretinal cysts and epiretinal membranes but not for other retinal changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertebroplasty restores stiffness and strength of fractured vertebral bodies, but alters their stress transfer. This unwanted effect may be reduced by using more compliant cements. However, systematic experimental comparison of structural properties between standard and low-modulus augmentation needs to be done. This study investigated how standard and low-modulus cement augmentation affects apparent stiffness, strength, and endplate pressure distribution of vertebral body sections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to assess stent strut coverage, malapposition, protrusion, and coronary evaginations as markers of healing 5 years after implantation of sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES), by optical coherence tomography (OCT).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advances in diagnostic imaging and the introduction of damage control strategy in trauma have influenced our approach to treating liver trauma patients. The objective of the present study was to investigate the impact of change in liver trauma management on outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vascular-stromal compartment of lymph nodes is important for lymph node function, and high endothelial venules (HEVs) play a critical role in controlling the entry of recirculating lymphocytes. In autoimmune and autoinflammatory diseases, lymph node swelling is often accompanied by apparent HEV expansion and, potentially, targeting HEV expansion could be used therapeutically to limit autoimmunity. In previous studies using mostly flow cytometry analysis, we defined three differentially regulated phases of lymph node vascular-stromal growth: initiation, expansion, and the re-establishment of vascular quiescence and stabilization. In this study, we use optical projection tomography to better understand the morphologic aspects of HEV growth upon immunization with ovalbumin/CFA (OVA/CFA). We find HEV elongation as well as modest arborization during the initiation phase, increased arborization during the expansion phase, and, finally, vessel narrowing during the re-establishment of vascular quiescence and stabilization. We also examine acutely enlarged autoinflammatory lymph nodes induced by regulatory T cell depletion and show that HEVs are expanded and morphologically similar to the expanded HEVs in OVA/CFA-stimulated lymph nodes. These results reinforce the idea of differentially regulated, distinct phases of vascular-stromal growth after immunization and suggest that insights gained from studying immunization-induced lymph node vascular growth may help to understand how the lymph node vascular-stromal compartment could be therapeutically targeted in autoimmune and autoinflammatory diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whole-body computed tomography (WBCT) plays an important role in the management of severely injured patients. We evaluated the radiation exposure of WBCT scans using different positioning boards and arm positions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To quantify the circumferential healing process at 6 and 12 months following scaffold implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity, and in their backscattering ultrasound signal, identified as "pseudo dense-calcium" (DC) by VH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the ability of low-dose CT to detect and characterize the most common CT patterns of pulmonary disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A main field in biomedical optics research is diffuse optical tomography, where intensity variations of the transmitted light traversing through tissue are detected. Mathematical models and reconstruction algorithms based on finite element methods and Monte Carlo simulations describe the light transport inside the tissue and determine differences in absorption and scattering coefficients. Precise knowledge of the sample's surface shape and orientation is required to provide boundary conditions for these techniques. We propose an integrated method based on structured light three-dimensional (3-D) scanning that provides detailed surface information of the object, which is usable for volume mesh creation and allows the normalization of the intensity dispersion between surface and camera. The experimental setup is complemented by polarization difference imaging to avoid overlaying byproducts caused by inter-reflections and multiple scattering in semitransparent tissue.