853 resultados para single-frequency fiber amplifier


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Impact detection in aeronautical structures allows predicting their future reliability and performance. An impact can produce microscopic fissures that could evolve into fractures or even the total collapse of the structure, so it is important to know the location and severity of each impact. For this purpose, optical fibers with Bragg gratings are used to analyze each impact and the vibrations generated by them. In this paper it is proven that optical fibers with Bragg gratings can be used to detect impacts, and also that a high-frequency interrogator is necessary to collect valuable information about the impacts. The use of two interrogators constitutes the main novelty of this paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ENGLISH: A two-stage sampling design is used to estimate the variances of the numbers of yellowfin in different age groups caught in the eastern Pacific Ocean. For purse seiners, the primary sampling unit (n) is a brine well containing fish from a month-area stratum; the number of fish lengths (m) measured from each well are the secondary units. The fish cannot be selected at random from the wells because of practical limitations. The effects of different sampling methods and other factors on the reliability and precision of statistics derived from the length-frequency data were therefore examined. Modifications are recommended where necessary. Lengths of fish measured during the unloading of six test wells revealed two forms of inherent size stratification: 1) short-term disruptions of existing pattern of sizes, and 2) transition zones between long-term trends in sizes. To some degree, all wells exhibited cyclic changes in mean size and variance during unloading. In half of the wells, it was observed that size selection by the unloaders induced a change in mean size. As a result of stratification, the sequence of sizes removed from all wells was non-random, regardless of whether a well contained fish from a single set or from more than one set. The number of modal sizes in a well was not related to the number of sets. In an additional well composed of fish from several sets, an experiment on vertical mixing indicated that a representative sample of the contents may be restricted to the bottom half of the well. The contents of the test wells were used to generate 25 simulated wells and to compare the results of three sampling methods applied to them. The methods were: (1) random sampling (also used as a standard), (2) protracted sampling, in which the selection process was extended over a large portion of a well, and (3) measuring fish consecutively during removal from the well. Repeated sampling by each method and different combinations indicated that, because the principal source of size variation occurred among primary units, increasing n was the most effective way to reduce the variance estimates of both the age-group sizes and the total number of fish in the landings. Protracted sampling largely circumvented the effects of size stratification, and its performance was essentially comparable to that of random sampling. Sampling by this method is recommended. Consecutive-fish sampling produced more biased estimates with greater variances. Analysis of the 1988 length-frequency samples indicated that, for age groups that appear most frequently in the catch, a minimum sampling frequency of one primary unit in six for each month-area stratum would reduce the coefficients of variation (CV) of their size estimates to approximately 10 percent or less. Additional stratification of samples by set type, rather than month-area alone, further reduced the CV's of scarce age groups, such as the recruits, and potentially improved their accuracy. The CV's of recruitment estimates for completely-fished cohorts during the 198184 period were in the vicinity of 3 to 8 percent. Recruitment estimates and their variances were also relatively insensitive to changes in the individual quarterly catches and variances, respectively, of which they were composed. SPANISH: Se usa un diseño de muestreo de dos etapas para estimar las varianzas de los números de aletas amari11as en distintos grupos de edad capturados en el Océano Pacifico oriental. Para barcos cerqueros, la unidad primaria de muestreo (n) es una bodega de salmuera que contenía peces de un estrato de mes-área; el numero de ta11as de peces (m) medidas de cada bodega es la unidad secundaria. Limitaciones de carácter practico impiden la selección aleatoria de peces de las bodegas. Por 10 tanto, fueron examinados los efectos de distintos métodos de muestreo y otros factores sobre la confiabilidad y precisión de las estadísticas derivadas de los datos de frecuencia de ta11a. Se recomiendan modificaciones donde sean necesarias. Las ta11as de peces medidas durante la descarga de seis bodegas de prueba revelaron dos formas de estratificación inherente por ta11a: 1) perturbaciones a corto plazo en la pauta de ta11as existente, y 2) zonas de transición entre las tendencias a largo plazo en las ta11as. En cierto grado, todas las bodegas mostraron cambios cíclicos en ta11a media y varianza durante la descarga. En la mitad de las bodegas, se observo que selección por ta11a por los descargadores indujo un cambio en la ta11a media. Como resultado de la estratificación, la secuencia de ta11as sacadas de todas las bodegas no fue aleatoria, sin considerar si una bodega contenía peces de un solo lance 0 de mas de uno. El numero de ta11as modales en una bodega no estaba relacionado al numero de lances. En una bodega adicional compuesta de peces de varios lances, un experimento de mezcla vertical indico que una muestra representativa del contenido podría estar limitada a la mitad inferior de la bodega. Se uso el contenido de las bodegas de prueba para generar 25 bodegas simuladas y comparar los resultados de tres métodos de muestreo aplicados a estas. Los métodos fueron: (1) muestreo aleatorio (usado también como norma), (2) muestreo extendido, en el cual el proceso de selección fue extendido sobre una porción grande de una bodega, y (3) medición consecutiva de peces durante la descarga de la bodega. EI muestreo repetido con cada método y distintas combinaciones de n y m indico que, puesto que la fuente principal de variación de ta11a ocurría entre las unidades primarias, aumentar n fue la manera mas eficaz de reducir las estimaciones de la varianza de las ta11as de los grupos de edad y el numero total de peces en los desembarcos. El muestreo extendido evito mayormente los efectos de la estratificación por ta11a, y su desempeño fue esencialmente comparable a aquel del muestreo aleatorio. Se recomienda muestrear con este método. El muestreo de peces consecutivos produjo estimaciones mas sesgadas con mayores varianzas. Un análisis de las muestras de frecuencia de ta11a de 1988 indico que, para los grupos de edad que aparecen con mayor frecuencia en la captura, una frecuencia de muestreo minima de una unidad primaria de cada seis para cada estrato de mes-área reduciría los coeficientes de variación (CV) de las estimaciones de ta11a correspondientes a aproximadamente 10% 0 menos. Una estratificación adicional de las muestras por tipo de lance, y no solamente mes-área, redujo aun mas los CV de los grupos de edad escasos, tales como los reclutas, y mejoró potencialmente su precisión. Los CV de las estimaciones del reclutamiento para las cohortes completamente pescadas durante 1981-1984 fueron alrededor de 3-8%. Las estimaciones del reclutamiento y sus varianzas fueron también relativamente insensibles a cambios en las capturas de trimestres individuales y las varianzas, respectivamente, de las cuales fueron derivadas. (PDF contains 70 pages)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Understanding fluctuations in tropical cyclone activity along United States shores and abroad becomes increasingly important as coastal managers and planners seek to save lives, mitigate damage, and plan for resilience in the face of changing storminess and sea-level rise. Tropical cyclone activity has long been of concern to coastal areas as they bring strong winds, heavy rains, and high seas. Given projections of a warming climate, current estimates suggest that not only will tropical cyclones increase in frequency, but also in intensity (maximum sustained winds and minimum central pressures). An understanding of what has happened historically is an important step in identifying potential future changes in tropical cyclone frequency and intensity. The ability to detect such changes depends on a consistent and reliable global tropical cyclone dataset. Until recently no central repository for historical tropical cyclone data existed. To fill this need, the International Best Track Archive for Climate Stewardship (IBTrACS) dataset was developed to collect all known global historical tropical cyclone data into a single source for dissemination. With this dataset, a global examination of changes in tropical cyclone frequency and intensity can be performed. Caveats apply to any historical tropical cyclone analysis however, as the data contributed to the IBTrACS archive from various tropical cyclone warning centers is still replete with biases that may stem from operational changes, inhomogeneous monitoring programs, and time discontinuities. A detailed discussion of the difficulties in detecting trends using tropical cyclone data can be found in Landsea et al. 2006. The following sections use the IBTrACS dataset to show the global spatial variability of tropical cyclone frequency and intensity. Analyses will show where the strongest storms typically occur, the regions with the highest number of tropical cyclones per decade, and the locations of highest average maximum wind speeds. (PDF contains 3 pages)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Among the branches of astronomy, radio astronomy is unique in that it spans the largest portion of the electromagnetic spectrum, e.g., from about 10 MHz to 300 GHz. On the other hand, due to scientific priorities as well as technological limitations, radio astronomy receivers have traditionally covered only about an octave bandwidth. This approach of "one specialized receiver for one primary science goal" is, however, not only becoming too expensive for next-generation radio telescopes comprising thousands of small antennas, but also is inadequate to answer some of the scientific questions of today which require simultaneous coverage of very large bandwidths.

This thesis presents significant improvements on the state of the art of two key receiver components in pursuit of decade-bandwidth radio astronomy: 1) reflector feed antennas; 2) low-noise amplifiers on compound-semiconductor technologies. The first part of this thesis introduces the quadruple-ridged flared horn, a flexible, dual linear-polarization reflector feed antenna that achieves 5:1-7:1 frequency bandwidths while maintaining near-constant beamwidth. The horn is unique in that it is the only wideband feed antenna suitable for radio astronomy that: 1) can be designed to have nominal 10 dB beamwidth between 30 and 150 degrees; 2) requires one single-ended 50 Ohm low-noise amplifier per polarization. Design, analysis, and measurements of several quad-ridged horns are presented to demonstrate its feasibility and flexibility.

The second part of the thesis focuses on modeling and measurements of discrete high-electron mobility transistors (HEMTs) and their applications in wideband, extremely low-noise amplifiers. The transistors and microwave monolithic integrated circuit low-noise amplifiers described herein have been fabricated on two state-of-the-art HEMT processes: 1) 35 nm indium phosphide; 2) 70 nm gallium arsenide. DC and microwave performance of transistors from both processes at room and cryogenic temperatures are included, as well as first-reported measurements of detailed noise characterization of the sub-micron HEMTs at both temperatures. Design and measurements of two low-noise amplifiers covering 1--20 and 8—50 GHz fabricated on both processes are also provided, which show that the 1--20 GHz amplifier improves the state of the art in cryogenic noise and bandwidth, while the 8--50 GHz amplifier achieves noise performance only slightly worse than the best published results but does so with nearly a decade bandwidth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 120TW/36fs laser system based on Ti:sapphire chirped-pulse amplification (CPA) has been successfully established in our lab. The final four pass Ti:sapphire amplifier pumped by an energetic single-shot Nd:YAG-Nd:glass laser was designed and optimized. With 24J/8ns pump energy at 532 nm, 300 mJ/220 ps chirped pulse was amplified to 5.98 J in this amplifier, and a total saturated gain of similar to 20 was achieved. The focused intensity of compressed beam could reach to 10(20) W/cm(2) with the M-2 of similar to 2.0. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Being able to detect a single molecule without the use of labels has been a long standing goal of bioengineers and physicists. This would simplify applications ranging from single molecular binding studies to those involving public health and security, improved drug screening, medical diagnostics, and genome sequencing. One promising technique that has the potential to detect single molecules is the microtoroid optical resonator. The main obstacle to detecting single molecules, however, is decreasing the noise level of the measurements such that a single molecule can be distinguished from background. We have used laser frequency locking in combination with balanced detection and data processing techniques to reduce the noise level of these devices and report the detection of a wide range of nanoscale objects ranging from nanoparticles with radii from 100 to 2.5 nm, to exosomes, ribosomes, and single protein molecules (mouse immunoglobulin G and human interleukin-2). We further extend the exosome results towards creating a non-invasive tumor biopsy assay. Our results, covering several orders of magnitude of particle radius (100 nm to 2 nm), agree with the `reactive' model prediction for the frequency shift of the resonator upon particle binding. In addition, we demonstrate that molecular weight may be estimated from the frequency shift through a simple formula, thus providing a basis for an ``optical mass spectrometer'' in solution. We anticipate that our results will enable many applications, including more sensitive medical diagnostics and fundamental studies of single receptor-ligand and protein-protein interactions in real time. The thesis summarizes what we have achieved thus far and shows that the goal of detecting a single molecule without the use of labels can now be realized.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With continuing advances in CMOS technology, feature sizes of modern Silicon chip-sets have gone down drastically over the past decade. In addition to desktops and laptop processors, a vast majority of these chips are also being deployed in mobile communication devices like smart-phones and tablets, where multiple radio-frequency integrated circuits (RFICs) must be integrated into one device to cater to a wide variety of applications such as Wi-Fi, Bluetooth, NFC, wireless charging, etc. While a small feature size enables higher integration levels leading to billions of transistors co-existing on a single chip, it also makes these Silicon ICs more susceptible to variations. A part of these variations can be attributed to the manufacturing process itself, particularly due to the stringent dimensional tolerances associated with the lithographic steps in modern processes. Additionally, RF or millimeter-wave communication chip-sets are subject to another type of variation caused by dynamic changes in the operating environment. Another bottleneck in the development of high performance RF/mm-wave Silicon ICs is the lack of accurate analog/high-frequency models in nanometer CMOS processes. This can be primarily attributed to the fact that most cutting edge processes are geared towards digital system implementation and as such there is little model-to-hardware correlation at RF frequencies.

All these issues have significantly degraded yield of high performance mm-wave and RF CMOS systems which often require multiple trial-and-error based Silicon validations, thereby incurring additional production costs. This dissertation proposes a low overhead technique which attempts to counter the detrimental effects of these variations, thereby improving both performance and yield of chips post fabrication in a systematic way. The key idea behind this approach is to dynamically sense the performance of the system, identify when a problem has occurred, and then actuate it back to its desired performance level through an intelligent on-chip optimization algorithm. We term this technique as self-healing drawing inspiration from nature's own way of healing the body against adverse environmental effects. To effectively demonstrate the efficacy of self-healing in CMOS systems, several representative examples are designed, fabricated, and measured against a variety of operating conditions.

We demonstrate a high-power mm-wave segmented power mixer array based transmitter architecture that is capable of generating high-speed and non-constant envelope modulations at higher efficiencies compared to existing conventional designs. We then incorporate several sensors and actuators into the design and demonstrate closed-loop healing against a wide variety of non-ideal operating conditions. We also demonstrate fully-integrated self-healing in the context of another mm-wave power amplifier, where measurements were performed across several chips, showing significant improvements in performance as well as reduced variability in the presence of process variations and load impedance mismatch, as well as catastrophic transistor failure. Finally, on the receiver side, a closed-loop self-healing phase synthesis scheme is demonstrated in conjunction with a wide-band voltage controlled oscillator to generate phase shifter local oscillator (LO) signals for a phased array receiver. The system is shown to heal against non-idealities in the LO signal generation and distribution, significantly reducing phase errors across a wide range of frequencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a simple single-layer magnetic microtrap configuration which can trap an array of magnetically-trapped Bose-Einstein condensate. The configuration consists of two series of parallel wires perpendicular to each other and all of the crossing points are cut off for maintaining the uniformity of the current. We analyse the trapping potential, the position of trapping centres and the uniformity of the array of the traps. The trapping depth and trapping frequency with different parameters are also calculated. Lastly, the effect of the cut-off crossing points, dissipate power, chip production are introduced concisely.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The field of cavity optomechanics, which concerns the coupling of a mechanical object's motion to the electromagnetic field of a high finesse cavity, allows for exquisitely sensitive measurements of mechanical motion, from large-scale gravitational wave detection to microscale accelerometers. Moreover, it provides a potential means to control and engineer the state of a macroscopic mechanical object at the quantum level, provided one can realize sufficiently strong interaction strengths relative to the ambient thermal noise. Recent experiments utilizing the optomechanical interaction to cool mechanical resonators to their motional quantum ground state allow for a variety of quantum engineering applications, including preparation of non-classical mechanical states and coherent optical to microwave conversion. Optomechanical crystals (OMCs), in which bandgaps for both optical and mechanical waves can be introduced through patterning of a material, provide one particularly attractive means for realizing strong interactions between high-frequency mechanical resonators and near-infrared light. Beyond the usual paradigm of cavity optomechanics involving isolated single mechanical elements, OMCs can also be fashioned into planar circuits for photons and phonons, and arrays of optomechanical elements can be interconnected via optical and acoustic waveguides. Such coupled OMC arrays have been proposed as a way to realize quantum optomechanical memories, nanomechanical circuits for continuous variable quantum information processing and phononic quantum networks, and as a platform for engineering and studying quantum many-body physics of optomechanical meta-materials.

However, while ground state occupancies (that is, average phonon occupancies less than one) have been achieved in OMC cavities utilizing laser cooling techniques, parasitic absorption and the concomitant degradation of the mechanical quality factor fundamentally limit this approach. On the other hand, the high mechanical frequency of these systems allows for the possibility of using a dilution refrigerator to simultaneously achieve low thermal occupancy and long mechanical coherence time by passively cooling the device to the millikelvin regime. This thesis describes efforts to realize the measurement of OMC cavities inside a dilution refrigerator, including the development of fridge-compatible optical coupling schemes and the characterization of the heating dynamics of the mechanical resonator at sub-kelvin temperatures.

We will begin by summarizing the theoretical framework used to describe cavity optomechanical systems, as well as a handful of the quantum applications envisioned for such devices. Then, we will present background on the design of the nanobeam OMC cavities used for this work, along with details of the design and characterization of tapered fiber couplers for optical coupling inside the fridge. Finally, we will present measurements of the devices at fridge base temperatures of Tf = 10 mK, using both heterodyne spectroscopy and time-resolved sideband photon counting, as well as detailed analysis of the prospects for future quantum applications based on the observed optically-induced heating.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the advent of the laser in the year 1960, the field of optics experienced a renaissance from what was considered to be a dull, solved subject to an active area of development, with applications and discoveries which are yet to be exhausted 55 years later. Light is now nearly ubiquitous not only in cutting-edge research in physics, chemistry, and biology, but also in modern technology and infrastructure. One quality of light, that of the imparted radiation pressure force upon reflection from an object, has attracted intense interest from researchers seeking to precisely monitor and control the motional degrees of freedom of an object using light. These optomechanical interactions have inspired myriad proposals, ranging from quantum memories and transducers in quantum information networks to precision metrology of classical forces. Alongside advances in micro- and nano-fabrication, the burgeoning field of optomechanics has yielded a class of highly engineered systems designed to produce strong interactions between light and motion.

Optomechanical crystals are one such system in which the patterning of periodic holes in thin dielectric films traps both light and sound waves to a micro-scale volume. These devices feature strong radiation pressure coupling between high-quality optical cavity modes and internal nanomechanical resonances. Whether for applications in the quantum or classical domain, the utility of optomechanical crystals hinges on the degree to which light radiating from the device, having interacted with mechanical motion, can be collected and detected in an experimental apparatus consisting of conventional optical components such as lenses and optical fibers. While several efficient methods of optical coupling exist to meet this task, most are unsuitable for the cryogenic or vacuum integration required for many applications. The first portion of this dissertation will detail the development of robust and efficient methods of optically coupling optomechanical resonators to optical fibers, with an emphasis on fabrication processes and optical characterization.

I will then proceed to describe a few experiments enabled by the fiber couplers. The first studies the performance of an optomechanical resonator as a precise sensor for continuous position measurement. The sensitivity of the measurement, limited by the detection efficiency of intracavity photons, is compared to the standard quantum limit imposed by the quantum properties of the laser probe light. The added noise of the measurement is seen to fall within a factor of 3 of the standard quantum limit, representing an order of magnitude improvement over previous experiments utilizing optomechanical crystals, and matching the performance of similar measurements in the microwave domain.

The next experiment uses single photon counting to detect individual phonon emission and absorption events within the nanomechanical oscillator. The scattering of laser light from mechanical motion produces correlated photon-phonon pairs, and detection of the emitted photon corresponds to an effective phonon counting scheme. In the process of scattering, the coherence properties of the mechanical oscillation are mapped onto the reflected light. Intensity interferometry of the reflected light then allows measurement of the temporal coherence of the acoustic field. These correlations are measured for a range of experimental conditions, including the optomechanical amplification of the mechanics to a self-oscillation regime, and comparisons are drawn to a laser system for phonons. Finally, prospects for using phonon counting and intensity interferometry to produce non-classical mechanical states are detailed following recent proposals in literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computation technology has dramatically changed the world around us; you can hardly find an area where cell phones have not saturated the market, yet there is a significant lack of breakthroughs in the development to integrate the computer with biological environments. This is largely the result of the incompatibility of the materials used in both environments; biological environments and experiments tend to need aqueous environments. To help aid in these development chemists, engineers, physicists and biologists have begun to develop microfluidics to help bridge this divide. Unfortunately, the microfluidic devices required large external support equipment to run the device. This thesis presents a series of several microfluidic methods that can help integrate engineering and biology by exploiting nanotechnology to help push the field of microfluidics back to its intended purpose, small integrated biological and electrical devices. I demonstrate this goal by developing different methods and devices to (1) separate membrane bound proteins with the use of microfluidics, (2) use optical technology to make fiber optic cables into protein sensors, (3) generate new fluidic devices using semiconductor material to manipulate single cells, and (4) develop a new genetic microfluidic based diagnostic assay that works with current PCR methodology to provide faster and cheaper results. All of these methods and systems can be used as components to build a self-contained biomedical device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A highly uniform multiwavelength erbium-doped fiber ring laser with an intracavity sine phase modulator is demonstrated. The flat output spectrum is achieved by optimizing the cavity structure, modulation amplitude, and frequency of the sine phase modulator. Fifteen lasing lines with wavelength spacing of 0.9 nm appear simultaneously and stably with power differences less than 2 dB and side-mode suppression ratio higher than 32 dB. In addition, the proposed cavity can support unidirectional operation without optical isolators. An output power difference of about 20 dB is realized between the counterclockwise and clockwise directions, which is almost independent of the pump power and lasing wavelengths. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The frequency upconversion properties of Er3+/Yb3+-codoped heavy metal oxide lead-germanium-bismuth oxide glasses under 975 mn excitation are investigated. Intense green and red emission bands centered at 536, 556 and 672 run, corresponding to the H-2(1/2) --> I-4(15/2), S-4(3/2) --> I-4(15/2) and F-4(9/2) -->I-4(15/2) transitions of Er3+, respectively, were simultaneously observed at room temperature. The influences of PbO on upconversion intensity for the green (536 and 556 nm) and red (672 nm) emissions were compared and discussed. The optimized rare earth doping ratio of Er3+ and Yb3+, is 1:5 for these glasses, which results in the stronger upconversion fluorescence intensities. The dependence of intensities of upconversion emission on excitation power and possible upconversion mechanisms were evaluated and analyzed. The structure of glass has been investigated by means of infrared (IR) spectral analysis. The results indicate that the Er3+/Yb3+-codoped heavy metal oxide lead-germanium-bismuth oxide glasses may be a potential materials for developing upconversion fiber optic devices. (C) 2006 Published by Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel scheme is proposed to transform a Gaussian pulse to a millimeter-wave frequency modulation pulse by using an apodized Moire fiber Bragg grating in radio-over-fiber system. The relation between the input and output pulses is analyzed theoretically by Fourier transformation method and the requirements for the proposed fiber grating are presented. An apodized Moire fiber Bragg grating is designed and its characteristics are studied. It is shown that the proposed device is feasible, and the new scheme is believed to be an effective solution for the generation of millimeter-wave sub-carrier in future radio-over-fiber systems. (c) 2006 Elsevier B.V. All rights reserved.