1000 resultados para residual magnetic torque


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new technology for the three-dimensional (3-D) stacking of very thin chips on a substrate is currently under development within the ultrathin chip stacking (UTCS) Esprit Project 24910. In this work, we present the first-level UTCS structure and the analysis of the thermomechanical stresses produced by the manufacturing process. Chips are thinned up to 10 or 15 m. We discuss potentially critical points at the edges of the chips, the suppression of delamination problems of the peripheral dielectric matrix and produce a comparative study of several technological choices for the design of metallic interconnect structures. The purpose of these calculations is to give inputs for the definition of design rules for this technology. We have therefore undertaken a programme that analyzes the influence of sundry design parameters and alternative development options. Numerical analyses are based on the finite element method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare multidetector-row computed tomographic (MDCT) enterography with magnetic resonance (MR) enterography performed upon acute exacerbation of Crohn's disease. Subjects and Methods: Fifty-seven patients (mean age 33.5) with proven Crohn's disease and symptoms suggesting acute exacerbation were prospectively included. After oral administration of 1-2 liters of 5% methylcellulose, MDCT and MR enterography were performed on each patient (mean delay <24 h). Three radiologists blindly and independently evaluated each examination for technical quality and in terms of 8 pathological features of Crohn's disease. Observers' agreement, sensitivity and specificity resulted from comparison with the reference standard [surgery (n = 24), endoscopy (n = 17) and long-term follow-up (n = 16)]. Results: MDCT enterography demonstrated fewer artifacts than MR enterography (p < 0.0001). In 48 MDCT/MR enterography examinations, active disease was demonstrated: abscesses (n = 11), fistulas (n = 13), stenoses (n = 23) and/or intestinal inflammation (n = 38). Observers' agreement (range 0.56-0.87) was not significantly different between MDCT and MR enterography, neither in terms of sensitivity (range 58-95%) nor specificity (range 67-100%) for each of the 8 pathological features. Conclusion: Statistically, MR enterography is of similar diagnostic value as MDCT enterography for acute complications of Crohn's disease. Since the typical Crohn's disease patient is young and will very likely undergo life-long imaging, and given concerns about radiation exposure with MDCT, MR enterography should be the preferred modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We find that the use of V(100) buffer layers on MgO(001) substrates for the epitaxy of FePd binary alloys yields to the formation at intermediate and high deposition temperatures of a FePd¿FeV mixed phase due to strong V diffusion accompanied by a loss of layer continuity and strong increase of its mosaic spread. Contrary to what is usually found in this kind of systems, these mixed phase structures exhibit perpendicular magnetic anisotropy (PMA) which is not correlated with the presence of chemical order, almost totally absent in all the fabricated structures, even at deposition temperatures where it is usually obtained with other buffer layers. Thus the observed PMA can be ascribed to the V interdiffusion and the formation of a FeV alloy, being the global sample saturation magnetization also reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report here on the growth of NiFe2O4 epitaxial thin films of different thickness (3 nm ¿ t ¿ 32 nm) on single crystalline substrates having spinel (MgAl2O4) or perovskite (SrTiO3) structure. Ultrathin films, grown on any of those substrates, display a huge enhancement of the saturation magnetization: we will show that partial cationic inversion may account for this enhancement, although we will argue that suppression of antiparallel collinear spin alignment due to size-effects cannot be excluded. Besides, for thicker films, the magnetization of films on MAO is found to be similar to that of bulk ferrite; in contrast, the magnetization of films on STO is substantially lower than bulk. We discuss on the possible mechanisms leading to this remarkable difference of magnetization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report of one case of bilateral cryptorchism with non-palpable testes in a 26-year old patient with progressive muscle dystrophy. Physical examination and ultrasound study to detect the testicular location were inconclusive. An analysis is made of data obtained with the NMR study as well as a review of the advantages and contributions from this new technique in the location and characterization of undescended testes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach to the local measurement of residual stress in microstructures is described in this paper. The presented technique takes advantage of the combined milling-imaging features of a focused ion beam (FIB) equipment to scale down the widely known hole drilling method. This method consists of drilling a small hole in a solid with inherent residual stresses and measuring the strains/displacements caused by the local stress release, that takes place around the hole. In the presented case, the displacements caused by the milling are determined by applying digital image correlation (DIC) techniques to high resolution micrographs taken before and after the milling process. The residual stress value is then obtained by fitting the measured displacements to the analytical solution of the displacement fields. The feasibility of this approach has been demonstrated on a micromachined silicon nitride membrane showing that this method has high potential for applications in the field of mechanical characterization of micro/nanoelectromechanical systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epitaxial Fe/MgO heterostructures have been grown on Si(001) by a combination of sputtering and laser ablation deposition techniques. The growth of MgO on Si(001) is mainly determined by the nature of the interface, with large lattice mismatch and the presence of an amorphous layer of unclear origin. Reflection high energy electron diffraction patterns of this MgO buffer layer are characteristic of an epitaxial, but disordered, structure. The structural quality of subsequent Fe and MgO layers continuously improves due to the better lattice match and the burial of defects. A weak uniaxial in-plane magnetic anisotropy is found superimposed on the expected cubic biaxial anisotropy. This additional anisotropy, of interfacial nature and often found in Fe/MgO and Fe/MgO/GaAs(001) systems, is less intense here due to the poorer MgO/Si interface quality compared with that of other systems. From the evolution of the anisotropy field with film thickness, magnetic anisotropy is also found to depend on the crystal quality. Kerr measurements of a Fe/MgO multilayered structure grown on Si show two different switching fields, suggesting magnetic coupling of two of the three Fe layers. Nevertheless, due to the little sensitivity to the bottom Fe film, independent switching of the three layers cannot be ruled out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-invasive visualization of the coronary arteries represents a major challenge in modern cardiology, but this goal may be achieved in the near future by MR angiography. Possible applications are non-invasive diagnosis of coronary artery disease, and follow-up examinations for therapy control after PTCA, in order to detect restenosis at an early stage. A multiple slice technique (2 mm slice thickness, with a spatial resolution of 1 x 1 mm, Philips Gyroscan ACS-II, 1.5 Tesla) was used. Ten volunteers were imaged and 10 patients with coronary artery disease were examined before and after PTCA. MR measurements were validated by quantitative coronary angiography. The diameters of the proximal coronary arteries as measured by both methods were compared, and a good correlation was found (r = 0.76). Thus, it is concluded that non-invasive visualization of the coronary arteries is possible before and after PTCA and allows to determine potential restenoses. However, patient cooperation is essential for good image quality. Moreover, limited spatial image resolution and breathing artifacts restrict MR coronary angiography today to be used as a routine diagnostic tool for the diagnosis of coronary artery disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A deficiência de P é uma das limitações mais generalizadas ao estabelecimento e à manutenção de pastagens nas regiões tropicais. Essa deficiência é devida, principalmente, ao baixo teor e aos processos de adsorção/precipitação do P nos solos. Com o objetivo de avaliar a influência da calagem e da adubação orgânica sobre o efeito residual do P, aplicado ao feijoeiro, na nutrição fosfatada e no rendimento do braquiarão cultivado em sucessão, foram conduzidos, em casa de vegetação, quatro experimentos inteiramente ao acaso, em esquema fatorial 4 x 5 e três repetições. Cada unidade experimental foi constituída por um vaso contendo 4 dm³ dos solos: Latossolo Vermelho distrófico textura muito argilosa, Latossolo Vermelho-Amarelo distrófico textura argilosa, Latossolo Vermelho-Amarelo distrófico textura média e Neossolo Quartzarênico órtico textura arenosa. Cada solo, representando um experimento, recebeu os tratamentos constituídos de quatro doses de calcário (0,0; 0,5; 1,0; e 2,0 vezes a dose recomendada para elevar a saturação por bases a 60 %) e cinco doses de esterco bovino (0,0; 2,5; 5,0; 7,5; e 10,0 % do volume de solo). Os vasos foram cultivados com feijoeiro e, após a colheita deste, cultivaram-se três plantas de braquiarão, as quais foram submetidas a cortes consecutivos aos 70, 160 e 290 dias após a emergência. As produções totais de matéria seca e o acúmulo de P na parte aérea do braquiarão foram positivamente influenciados pela adubação orgânica e pela calagem. Esses tratamentos também influenciaram positivamente o efeito residual da adubação fosfatada, aplicada ao feijoeiro, na nutrição fosfatada e no rendimento do braquiarão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A aplicação de vinhaça na cana-de-açúcar, complementada com adubação nitrogenada e manutenção da palhada na superfície do solo, melhoram as propriedades físicas, químicas e biológicas do solo, podendo resultar em aumento da produtividade da cultura. O objetivo deste estudo foi avaliar o efeito residual de adubação na cana-planta e a adubação da cana-soca, com e sem aplicação de vinhaça, sob diferentes sistemas de colheita no município de Conceição da Barra - ES. O experimento foi conduzido no período de 2005 a 2007, num Argissolo Amarelo em Tabuleiros Costeiros. Utilizou-se o delineamento de blocos ao acaso com quatro repetições, no esquema fatorial 2 x 7, com parcelas subdivididas, sendo dois tratamentos cana crua e cana queimada e sete subtratamentos com diferentes doses de N associadas a doses de K2O na forma de cloreto de K e vinhaça. Os tratamentos foram: testemunha (T1); vinhaça (T2); vinhaça + 80 kg de N incorporado (T3); vinhaça + 80 kg de N em cobertura (T4); vinhaça + 40 kg de N em cobertura (T5); K2O + 80 kg de N incorporado (T6); e K2O + 80 kg de N em cobertura (T7). Não houve efeito residual de adubação na produtividade de colmos na cana-planta. A cana crua apresentou produtividade superior à da cana queimada na cana-soca. Nesta, a fertilização com vinhaça complementada com N incorporado ou em cobertura e a adubação com 120 kg de K2O na forma de KCl + 80 kg de N incorporados ao solo proporcionaram produtividade superior à dos demais tratamentos. Não foi verificada diferença na produtividade de colmos entre as doses de 40 e 80 kg ha-1 de N, aplicadas em cobertura na cana-soca. A extração e retorno de nutrientes ocorreu de forma similar entre cana-planta e cana-soca.