873 resultados para patient information


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioelectrical impedance analysis, (BIA), is a method of body composition analysis first investigated in 1962 which has recently received much attention by a number of research groups. The reasons for this recent interest are its advantages, (viz: inexpensive, non-invasive and portable) and also the increasing interest in the diagnostic value of body composition analysis. The concept utilised by BIA to predict body water volumes is the proportional relationship for a simple cylindrical conductor, (volume oc length2/resistance), which allows the volume to be predicted from the measured resistance and length. Most of the research to date has measured the body's resistance to the passage of a 50· kHz AC current to predict total body water, (TBW). Several research groups have investigated the application of AC currents at lower frequencies, (eg 5 kHz), to predict extracellular water, (ECW). However all research to date using BIA to predict body water volumes has used the impedance measured at a discrete frequency or frequencies. This thesis investigates the variation of impedance and phase of biological systems over a range of frequencies and describes the development of a swept frequency bioimpedance meter which measures impedance and phase at 496 frequencies ranging from 4 kHz to 1 MHz. The impedance of any biological system varies with the frequency of the applied current. The graph of reactance vs resistance yields a circular arc with the resistance decreasing with increasing frequency and reactance increasing from zero to a maximum then decreasing to zero. Computer programs were written to analyse the measured impedance spectrum and determine the impedance, Zc, at the characteristic frequency, (the frequency at which the reactance is a maximum). The fitted locus of the measured data was extrapolated to determine the resistance, Ro, at zero frequency; a value that cannot be measured directly using surface electrodes. The explanation of the theoretical basis for selecting these impedance values (Zc and Ro), to predict TBW and ECW is presented. Studies were conducted on a group of normal healthy animals, (n=42), in which TBW and ECW were determined by the gold standard of isotope dilution. The prediction quotients L2/Zc and L2/Ro, (L=length), yielded standard errors of 4.2% and 3.2% respectively, and were found to be significantly better than previously reported, empirically determined prediction quotients derived from measurements at a single frequency. The prediction equations established in this group of normal healthy animals were applied to a group of animals with abnormally low fluid levels, (n=20), and also to a group with an abnormal balance of extra-cellular to intracellular fluids, (n=20). In both cases the equations using L2/Zc and L2/Ro accurately and precisely predicted TBW and ECW. This demonstrated that the technique developed using multiple frequency bioelectrical impedance analysis, (MFBIA), can accurately predict both TBW and ECW in both normal and abnormal animals, (with standard errors of the estimate of 6% and 3% for TBW and ECW respectively). Isotope dilution techniques were used to determine TBW and ECW in a group of 60 healthy human subjects, (male. and female, aged between 18 and 45). Whole body impedance measurements were recorded on each subject using the MFBIA technique and the correlations between body water volumes, (TBW and ECW), and heighe/impedance, (for all measured frequencies), were compared. The prediction quotients H2/Zc and H2/Ro, (H=height), again yielded the highest correlation with TBW and ECW respectively with corresponding standard errors of 5.2% and 10%. The values of the correlation coefficients obtained in this study were very similar to those recently reported by others. It was also observed that in healthy human subjects the impedance measured at virtually any frequency yielded correlations not significantly different from those obtained from the MFBIA quotients. This phenomenon has been reported by other research groups and emphasises the need to validate the technique by investigating its application in one or more groups with abnormalities in fluid levels. The clinical application of MFBIA was trialled and its capability of detecting lymphoedema, (an excess of extracellular fluid), was investigated. The MFBIA technique was demonstrated to be significantly more sensitive, (P<.05), in detecting lymphoedema than the current technique of circumferential measurements. MFBIA was also shown to provide valuable information describing the changes in the quantity of muscle mass of the patient during the course of the treatment. The determination of body composition, (viz TBW and ECW), by MFBIA has been shown to be a significant improvement on previous bioelectrical impedance techniques. The merit of the MFBIA technique is evidenced in its accurate, precise and valid application in animal groups with a wide variation in body fluid volumes and balances. The multiple frequency bioelectrical impedance analysis technique developed in this study provides accurate and precise estimates of body composition, (viz TBW and ECW), regardless of the individual's state of health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Automatic spoken Language Identi¯cation (LID) is the process of identifying the language spoken within an utterance. The challenge that this task presents is that no prior information is available indicating the content of the utterance or the identity of the speaker. The trend of globalization and the pervasive popularity of the Internet will amplify the need for the capabilities spoken language identi¯ca- tion systems provide. A prominent application arises in call centers dealing with speakers speaking di®erent languages. Another important application is to index or search huge speech data archives and corpora that contain multiple languages. The aim of this research is to develop techniques targeted at producing a fast and more accurate automatic spoken LID system compared to the previous National Institute of Standards and Technology (NIST) Language Recognition Evaluation. Acoustic and phonetic speech information are targeted as the most suitable fea- tures for representing the characteristics of a language. To model the acoustic speech features a Gaussian Mixture Model based approach is employed. Pho- netic speech information is extracted using existing speech recognition technol- ogy. Various techniques to improve LID accuracy are also studied. One approach examined is the employment of Vocal Tract Length Normalization to reduce the speech variation caused by di®erent speakers. A linear data fusion technique is adopted to combine the various aspects of information extracted from speech. As a result of this research, a LID system was implemented and presented for evaluation in the 2003 Language Recognition Evaluation conducted by the NIST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schizophrenia is a mental disorder affecting 1-2% of the population and it is estimated 12-16% of hospital beds in Australia are occupied by patients with psychosis. The suicide rate for patients with this diagnosis is higher than that of the general population. Any technique which enhances training and treatment of this disorder will have a significant societal and economic impact. A significant research project using Virtual Reality (VR), in which both visual and auditory hallucinations are simulated, is currently being undertaken at the University of Queensland. The virtual environments created by the new software are expected to enhance the experiential learning outcomes of medical students by enabling them to experience the inner world of a patient with psychosis. In addition the Virtual Environment has the potential to provide a technologically advanced therapeutic setting where behavioral, exposure therapies can be conducted with exactly controlled exposure stimuli with an expected reduction in risk of harm. This paper reports on the current work of the project, previous stages of software development and future educational and clinical applications of the Virtual Environments. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

his case study aims to describe how general parenting principles can be used as part of parent-led, family-focused child weight management that is in line with current Australian Clinical Practice Guidelines. A parent-led, family-focused child weight management program was designed for use by dietitians with parents of young children (five- to nine-year-olds). The program utilises the cornerstones of overweight treatment: diet, activity, behaviour modification and family support delivered in an age-appropriate, family-focused manner. Parents participate in 16 sessions (4 parenting-focused, 8 lifestyle-focused and 4 individual telephone support calls) conducted weekly, fortnightly then monthly over six months. This case study illustrates how a family used the program, resulting in reduced degree of overweight and stabilised waist circumference in the child over 12 months. In conclusion, linking parenting skills to healthy family lifestyle education provides an innovative approach to family-focused child weight management. It addresses key Australian Clinical Practice Guidelines, works at the family level, and provides a means for dietitians to easily adopt age-appropriate behaviour modification as part of their practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This paper is a report of a study of variations in the pattern of nurse practitioner work in a range of service fields and geographical locations, across direct patient care, indirect patient care and service-related activities. Background. The nurse practitioner role has been implemented internationally as a service reform model to improve the access and timeliness of health care. There is a substantial body of research into the nurse practitioner role and service outcomes, but scant information on the pattern of nurse practitioner work and how this is influenced by different service models. --------- Methods: We used work sampling methods. Data were collected between July 2008 and January 2009. Observations were recorded from a random sample of 30 nurse practitioners at 10-minute intervals in 2-hour blocks randomly generated to cover two weeks of work time from a sampling frame of six weeks. --------- Results: A total of 12,189 individual observations were conducted with nurse practitioners across Australia. Thirty individual activities were identified as describing nurse practitioner work, and these were distributed across three categories. Direct care accounted for 36.1% of how nurse practitioners spend their time, indirect care accounted for 32.2% and service-related activities made up 31.9%. --------- Conclusion. These findings provide useful baseline data for evaluation of nurse practitioner positions and the service effect of these positions. However, the study also raises questions about the best use of nurse practitioner time and the influences of barriers to and facilitators of this model of service innovation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Internationally, collection of reliable data on new and evolving health-care roles is crucial. We describe a protocol for design and administration of a national census of an emergent health-care role, namely nurse practitioners in Australia using databases held by regulatory authorities. A questionnaire was developed to obtain data on the role and scope of practice of Australian nurse practitioners. Our tool comprised five sections and included a total of 56 questions, using 28 existing items from the National Nursing and Midwifery Labour Force Census and nine items recommended in the Nurse Practitioner Workforce Planning Minimum Data Set. Australian Nurse Registering Authorities (n = 6) distributed the survey on our behalf. This paper outlines our instrument and methods. The survey was administered to 238 authorized Australian nurse practitioners (85% response rate). Rigorous collection of standardized items will ensure health policy is informed by reliable and valid data. We will re-administer the survey 2 years following the first survey to measure change over time.