933 resultados para office equipment
Resumo:
This paper presents an investigation of the natural ventilation cooling potential (NVCP) of office buildings in the five generally recognised climate zones in China using the Thermal Resistance Ventilation (TRV) model, which is a simplified, coupled, thermal and airflow model. The acceptable operative temperature for naturally conditioned space supplied by the ASHARE Standard 55-2004 has been used for the comfort temperature setting. Dynamic simulations for a typical office room in the five representative cities, which are Harbin, Beijing, Shanghai, Kunming and Guangzhou, have been carried out. The study demonstrates that the NVCP depends on the multiple impacts of climate, the building's thermal characteristics, internal gains, ventilation profiles and regimes. The work shows how the simplified method can be used to generate detailed, indoor, operative temperature data based on the various building conditions and control profiles which are used to investigate the NVCP at the strategic design stage. The simulation results presented in this paper can be used as a reference guideline for natural ventilation design in China.
Resumo:
Aims and objectives. To examine the impact of written and verbal education on bed-making practices, in an attempt to reduce the prevalence of pressure ulcers. Background. The Department of Health has set targets for a 5% reduction per annum in the incidence of pressure ulcers. Electric profiling beds with a visco-elastic polymer mattress are a new innovation in pressure ulcer prevention; however, mattress efficacy is reduced by tightly tucking sheets around the mattress. Design. A prospective randomized pre/post-test experimental design. Methods. Ward managers at a teaching hospital were approached to participate in the study. Two researchers independently examined the tightness of the sheets around the mattresses. Wards were randomized to one of two groups. Groups A and B received written education. In addition, group B received verbal education on alternate days for one week. Beds were re-examined one month later. One researcher was blinded to the educational delivery received by the wards. Results. Twelve wards agreed to participate in the study and 245 beds were examined. Before education, 113 beds (46%) had sheets tucked correctly around the mattresses. Following education, this increased to 215 beds (87.8%) (chi(2) = 68.03, P < 0.001). There was no significant difference in the number of correctly made beds between the two different education groups: 100 (87.72%) beds correctly made in group A vs. 115 (87.79%) beds in group B (chi(2) = 0, P 0.987). Conclusions. Clear, concise written instruction improved practice but verbal education was not additionally beneficial. Relevance to clinical practice. Nurses are receptive to clear, concise written evidence regarding pressure ulcer prevention and incorporate this into clinical practice.
Office noise and employee concentration: identifying causes of disruption and potential improvements
Resumo:
A field study assessed subjective reports of distraction from various office sounds among 88 employees at two sites. In addition, the study examined the amount of exposure the workers had to the noise in order to determine any evidence for habituation. Finally, respondents were asked how they would improve their environment ( with respect to noise), and to rate examples of improvements with regards to their job satisfaction and performance. Out of the sample, 99% reported that their concentration was impaired by various components of office noise, especially telephones left ringing at vacant desks and people talking in the background. No evidence for habituation to these sounds was found. These results are interpreted in the light of previous research regarding the effects of noise in offices and the 'irrelevant sound effect'.
Resumo:
This study investigates the price effects of environmental certification on commercial real estate assets. It is argued that there are likely to be three main drivers of price differences between certified and noncertified buildings. These are additional occupier benefits, lower holding costs for investors and a lower risk premium. Drawing upon the CoStar database of U.S. commercial real estate assets, hedonic regression analysis is used to measure the effect of certification on both rent and price. The results suggest that, compared to buildings in the same submarkets, eco-certified buildings have both a rental and sale price premium.
Resumo:
The climatology of a stratosphere-resolving version of the Met Office’s climate model is studied and validated against ECMWF reanalysis data. Ensemble integrations are carried out at two different horizontal resolutions. Along with a realistic climatology and annual cycle in zonal mean zonal wind and temperature, several physical effects are noted in the model. The time of final warming of the winter polar vortex is found to descend monotonically in the Southern Hemisphere, as would be expected for purely radiative forcing. In the Northern Hemisphere, however, the time of final warming is driven largely by dynamical effects in the lower stratosphere and radiative effects in the upper stratosphere, leading to the earliest transition to westward winds being seen in the midstratosphere. A realistic annual cycle in stratospheric water vapor concentrations—the tropical “tape recorder”—is captured. Tropical variability in the zonal mean zonal wind is found to be in better agreement with the reanalysis for the model run at higher horizontal resolution because the simulated quasi-biennial oscillation has a more realistic amplitude. Unexpectedly, variability in the extratropics becomes less realistic under increased resolution because of reduced resolved wave drag and increased orographic gravity wave drag. Overall, the differences in climatology between the simulations at high and moderate horizontal resolution are found to be small.
Resumo:
The simulation and development work that has been undertaken to produce a signal equaliser used to improve the data rates from oil well logging instruments is presented. The instruments are lowered into the drill bore hole suspended by a cable which has poor electrical characteristics. The equaliser described in the paper corrects for the distortions that occur from the cable (dispersion and attenuation) with the result that the instrument can send data at 100 K.bits/second down its own suspension cable of 12 Km in length. The use of simulation techniques and tools were invaluable in generating a model for the distortions and proved to be a useful tool when site testing was not available.
Eco-labeling in commercial office markets: do LEED and Energy Star offices obtain multiple premiums?
Resumo:
Earlier estimates of the City of London office market are extended by considering a longer time series of data, covering two cycles, and by explicitly modeling of asymmetric space market responses to employment and supply shocks. A long run structural model linking real rental levels, office-based employment and the supply of office space is estimated and then rental adjustment processes are modeled using an error correction model framework. Rental adjustment is seen to be asymmetric, depending both on the direction of the supply and demand shocks and on the state of the space market at the time of the shock. Vacancy adjustment does not display asymmetries. There is also a supply adjustment equation. Two three-equation systems, one with symmetric rental adjustment and the other with asymmetric adjustment, are subjected to positive and negative shocks to employment. These illustrate differences in the two systems.