884 resultados para nanocarboni soft-templating carboni mesoporosi N-doping funzionalizzazione superficiale
Resumo:
The purpose of the study was to evaluate observer performance in the detection of pneumothorax with cesium iodide and amorphous silicon flat-panel detector radiography (CsI/a-Si FDR) presented as 1K and 3K soft-copy images. Forty patients with and 40 patients without pneumothorax diagnosed on previous and subsequent digital storage phosphor radiography (SPR, gold standard) had follow-up chest radiographs with CsI/a-Si FDR. Four observers confirmed or excluded the diagnosis of pneumothorax according to a five-point scale first on the 1K soft-copy image and then with help of 3K zoom function (1K monitor). Receiver operating characteristic (ROC) analysis was performed for each modality (1K and 3K). The area under the curve (AUC) values for each observer were 0.7815, 0.7779, 0.7946 and 0.7066 with 1K-matrix soft copies and 0.8123, 0.7997, 0.8078 and 0.7522 with 3K zoom. Overall detection of pneumothorax was better with 3K zoom. Differences between the two display methods were not statistically significant in 3 of 4 observers (p-values between 0.13 and 0.44; observer 4: p = 0.02). The detection of pneumothorax with 3K zoom is better than with 1K soft copy but not at a statistically significant level. Differences between both display methods may be subtle. Still, our results indicate that 3K zoom should be employed in clinical practice.
Resumo:
Doping in sport is often very present in the media. Doping does not only concern top level sports but it also has an impact on sport as a whole. Young athletes may be influenced by its role models. In Switzerland there are no exact data on this influence or on the use of doping by adolescents. In this article, the effects and side-effects especially on adolescents of some current doping substances are discussed. As well, the regulations of the therapeutic use exemptions for doping substances are explained.
Resumo:
PURPOSE: The aim of this study was to assess long-term changes in position of soft tissue landmarks following mandibular advancement and setback surgery. MATERIALS AND METHODS: Twenty-seven patients (14 women, 13 men; mean age, 36 years) who had undergone either mandibular advancement (15 patients) or setback surgery (12 patients), were available for a long-term follow-up an average of 12 years postoperatively. In all of these cases, lateral cephalometric radiographs taken immediately before operation, at 1 week, 14 months, and 12 years postoperatively, were studied. RESULTS: During the 14 months postoperatively, soft tissue chin and mentolabial fold followed its underlying hard tissue in all patients. A continuous skeletal relapse was observable 12 years after mandibular advancement, but soft tissue chin moved more in an anterior direction. After mandibular setback, soft and hard tissue landmarks remained almost unchanged. Over the entire observation period, a thickening of soft tissue at pogonion was generally seen, and particularly a thickening of the whole chin in the setback group. All patients showed a significant lengthening and thinning of the upper lip. In all except 2 males, the patient's body weight increased markedly. CONCLUSION: In contrast to the immediate postoperative stage, soft tissue changes observed an average of 12 years after the primary operation do not directly follow the movements of the underlying skeletal structure. The soft tissue profile changes observed over such a long term seem to be influenced not only by the underlying skeletal structure but also by other factors such as weight gain and aging process.
Resumo:
OBJECTIVE: The aim of this study was to evaluate soft tissue image quality of a mobile cone-beam computed tomography (CBCT) scanner with an integrated flat-panel detector. STUDY DESIGN: Eight fresh human cadavers were used in this study. For evaluation of soft tissue visualization, CBCT data sets and corresponding computed tomography (CT) and magnetic resonance imaging (MRI) data sets were acquired. Evaluation was performed with the help of 10 defined cervical anatomical structures. RESULTS: The statistical analysis of the scoring results of 3 examiners revealed the CBCT images to be of inferior quality regarding the visualization of most of the predefined structures. Visualization without a significant difference was found regarding the demarcation of the vertebral bodies and the pyramidal cartilages, the arteriosclerosis of the carotids (compared with CT), and the laryngeal skeleton (compared with MRI). Regarding arteriosclerosis of the carotids compared with MRI, CBCT proved to be superior. CONCLUSIONS: The integration of a flat-panel detector improves soft tissue visualization using a mobile CBCT scanner.
Resumo:
AIM: To evaluate the healing outcome of soft tissue dehiscence coverage at implant sites. MATERIAL AND METHODS: Ten patients with one mucosal recession defect at an implant site and a contralateral unrestored clinical crown without recession were recruited. The soft tissue recessions were surgically covered using a coronally advanced flap in combination with a free connective tissue graft. Healing was studied at 1, 3 and 6 months post-operatively. RESULTS: Soft tissue dehiscences were covered with a coronal overcompensation of the flap margin up to 1.2 mm after the procedure. After 1 month, the coverage shrank to a mean of 75%, after 3 months to 70% and after 6 months to 66%. CONCLUSIONS: The implant sites revealed a substantial, clinically significant improvement following coronal mucosal displacement in combination with connective tissue grafting, but in none of the sites, a could complete implant soft tissue dehiscence coverage be achieved.
Resumo:
OBJECTIVES: To evaluate the influence of flap tension on the tearing characteristics of mucosal tissue samples in relation to various suture and needle characteristics. MATERIAL AND METHODS: Lining and masticatory mucosal tissue samples obtained from pig jaws were prepared for in vitro testing. Tension tearing diagrams of 60 experiments were traced for 3-0, 5-0 and 7-0 sutures with applied forces up to 20 N. In the second part, the same experiments were repeated with 100 diagrams to test the influence of needle characteristics with 5-0 and 6-0 sutures using only gingival tissue samples. RESULTS: 3-0 sutures mainly lead to tissue breakage at an average of 13.4 N. In contrast, 7-0 sutures only resulted in breakage of the thread at a mean applied force of 3.7 N. With 5-0 sutures, both events occurred at random at a mean force of 14.6 N. Irrespective of the needle characteristics, the mean breaking force for gingival samples with 5-0 and 6-0 sutures was approximately 10 N. CONCLUSIONS: Tissue trauma may be reduced by choosing finer suture diameters, because thinner (6-0, 7-0) sutures lead to thread breakage rather than tissue breakage.
Resumo:
PURPOSE: The aim of the study was to conduct a long-term prospective follow-up on the stability of soft tissues after bilateral sagittal split osteotomy (BSSO) with rigid internal fixation to set back the mandible. PATIENTS AND METHODS: Seventeen consecutive patients (6 females, 11 males) were re-examined 12.7 years (T5) after surgery. The precedent follow-ups included: before surgery (T1), 5 days (T2) after surgery, 6.6 months (T3) after surgery, and 14.4 months after (T4) surgery. Lateral cephalograms were traced by hand, digitized, and evaluated with the Dentofacial Planner program (Dentofacial Software, Toronto, Canada). The x-axis for the system of coordinates ran through Sella (point 0) and the line NSL -7 degrees. RESULTS: The net effect of the soft tissue chin (soft tissue pogonion) was 79% of the setback at pogonion. At the lower lip (labrale inferior) it was 100% of the setback at lower incisor position. Point B' followed point B to 99%. Labrale inferior and menton' also showed a significant backward, as well as a downward, movement (T5 to T2). Gender correlated significantly (P = .004) with the anterior displacement of point B' and pogonion' (P = .012). The soft tissue relapse 12.7 years after BSSO setback surgery at point B' was 3% and 13% at pogonion'. CONCLUSION: Among the reasons for 3-dimensional long-term soft tissue changes of shape, the surgical technique, the normal process of human aging, the initial growth direction, and remodeling processes must be considered. Growth direction positively influenced the long-term outcome of setback surgery in female compared with male patients because further posterior movement of the mandibular soft tissue occurred.
Resumo:
The aim of the study was to conduct a long-term follow-up investigation of the stability of hard and soft tissues after bilateral sagittal split osteotomy (BSSO) with rigid internal (RIF) fixation to advance the mandible. Sixteen consecutive patients (12 females and 4 males, mean age 21.4 years) were available for re-examination 12.7 years (T5) after surgery. The preceding follow-ups were before (T1), and 5 days (T2), 7.3 months (T3), and 13.9 months (T4) after surgery. Lateral cephalograms were traced by hand, digitized, and evaluated with the Dentofacial Planner program. The x-axis for the system of co-ordinates ran through sella (point zero) and the line NSL -7 degrees. Thus, the program determined the x- and y-values of each variable and the usual angles and distances. Statistical analysis was carried out using Wilcoxon's matched-pair signed-ranks test with Bonferroni adjustments. The relationships between the examined variables were analysed by Spearman rank correlation coefficients. The backward relapse at point B (T5) was 2.42 mm, or 50 per cent, and at pogonion 3.21 mm, or 60 per cent of the initial advancement. The mean net effect at T5 on the labial fold (soft tissue point B) was 94 per cent of the advancement at point B. For the soft tissue chin (soft tissue pogonion), it was 119 per cent of the advancement at pogonion. The net effect on the lower lip (labrale inferior) was 55 per cent of the advancement at incision inferior. The amount of the surgical advancement of the mandible was correlated with the long-term relapse in point B. Among possible reasons for this relapse are the initial soft tissue profile, the initial growth direction, and the remodelling processes of the hard tissue.
Resumo:
With the development of micro systems, there is an increasing demand for integrable porous materials. In addition to those conventional applications, such as filtration, wicking, and insulating, many new micro devices, including micro reactors, sensors, actuators, and optical components, can benefit from porous materials. Conventional porous materials, such as ceramics and polymers, however, cannot meet the challenges posed by micro systems, due to their incompatibility with standard micro-fabrication processes. In an effort to produce porous materials that can be used in micro systems, porous silicon (PS) generated by anodization of single crystalline silicon has been investigated. In this work, the PS formation process has been extensively studied and characterized as a function of substrate type, crystal orientation, doping concentration, current density and surfactant concentration and type. Anodization conditions have been optimized for producing very thick porous silicon layers with uniform pore size, and for obtaining ideal pore morphologies. Three different types of porous silicon materials: meso porous silicon, macro porous silicon with straight pores, and macro porous silicon with tortuous pores, have been successfully produced. Regular pore arrays with controllable pore size in the range of 2µm to 6µm have been demonstrated as well. Localized PS formation has been achieved by using oxide/nitride/polysilicon stack as masking materials, which can withstand anodization in hydrofluoric acid up to twenty hours. A special etching cell with electrolytic liquid backside contact along with two process flows has been developed to enable the fabrication of thick macro porous silicon membranes with though wafer pores. For device assembly, Si-Au and In-Au bonding technologies have been developed. Very low bonding temperature (~200 degrees C) and thick/soft bonding layers (~6µm) have been achieved by In-Au bondi ng technology, which is able to compensate the potentially rough surface on the porous silicon sample without introducing significant thermal stress. The application of the porous silicon material in micro systems has been demonstrated in a micro gas chromatograph system by two indispensable components: an integrated vapor source and an inlet filter, wherein porous silicon performs the basic functions of porous media: wicking and filtration. By utilizing a macro porous silicon wick, the calibration vapor source was able to produce a uniform and repeatable vapor generation for n-decane with less than a 0.1% variation in 9 hours, and less than a 0.5% variation in rate over 7 days. With engineered porous silicon membranes the inlet filter was able to show a depth filtration with nearly 100% collection efficiency for particles larger than 0.3µm in diameter, a low pressure-drop of 523Pa at 20sccm flow rate, and a filter capacity of 500µg/cm2.
Resumo:
Multi-input multi-output (MIMO) technology is an emerging solution for high data rate wireless communications. We develop soft-decision based equalization techniques for frequency selective MIMO channels in the quest for low-complexity equalizers with BER performance competitive to that of ML sequence detection. We first propose soft decision equalization (SDE), and demonstrate that decision feedback equalization (DFE) based on soft-decisions, expressed via the posterior probabilities associated with feedback symbols, is able to outperform hard-decision DFE, with a low computational cost that is polynomial in the number of symbols to be recovered, and linear in the signal constellation size. Building upon the probabilistic data association (PDA) multiuser detector, we present two new MIMO equalization solutions to handle the distinctive channel memory. With their low complexity, simple implementations, and impressive near-optimum performance offered by iterative soft-decision processing, the proposed SDE methods are attractive candidates to deliver efficient reception solutions to practical high-capacity MIMO systems. Motivated by the need for low-complexity receiver processing, we further present an alternative low-complexity soft-decision equalization approach for frequency selective MIMO communication systems. With the help of iterative processing, two detection and estimation schemes based on second-order statistics are harmoniously put together to yield a two-part receiver structure: local multiuser detection (MUD) using soft-decision Probabilistic Data Association (PDA) detection, and dynamic noise-interference tracking using Kalman filtering. The proposed Kalman-PDA detector performs local MUD within a sub-block of the received data instead of over the entire data set, to reduce the computational load. At the same time, all the inter-ference affecting the local sub-block, including both multiple access and inter-symbol interference, is properly modeled as the state vector of a linear system, and dynamically tracked by Kalman filtering. Two types of Kalman filters are designed, both of which are able to track an finite impulse response (FIR) MIMO channel of any memory length. The overall algorithms enjoy low complexity that is only polynomial in the number of information-bearing bits to be detected, regardless of the data block size. Furthermore, we introduce two optional performance-enhancing techniques: cross- layer automatic repeat request (ARQ) for uncoded systems and code-aided method for coded systems. We take Kalman-PDA as an example, and show via simulations that both techniques can render error performance that is better than Kalman-PDA alone and competitive to sphere decoding. At last, we consider the case that channel state information (CSI) is not perfectly known to the receiver, and present an iterative channel estimation algorithm. Simulations show that the performance of SDE with channel estimation approaches that of SDE with perfect CSI.
Resumo:
In the literature, some transition metal salts have been used as soft Lewis acids to activate alkynes toward nucleophilic attack. For example, Pt(II), Au(I) and Pd(II) catalysts can catalyze cycloisomerization reactions of alkynyl compounds to give a variety of cyclic products. In order to expand the scope of these reactions, in chapter 2 of this dissertation, several alkynyl epoxides were isomerized to cyclic allyl vinyl ethers using PtCl2 as the catalyst. Three of these allyl vinyl ethers were hydrolyzed to 2-hydroxymorpholine derivatives and two were converted to piperidine derivatives by thermal Claisen rearrangement. In order to find more benign and inexpensive catalysts for these types of reactions, in chapter 3 of this dissertation, BiCl3 was used to catalyze the isomerization of eight enynes to pyrrolidine derivatives. This reaction was normally catalyzed by expensive noble metal catalysts, such as Pd(II), Pt(II) and Au(I). All the cyclic products are valuable intermediates in the synthesis of bioactive molecules, these soft Lewis acid catalyzed cycloisomerization may find applications in the synthesis of bioactive molecules.
Resumo:
It is known that the electrical resistance of annealed metals is usually smaller than that of metals in their cold worked state. The curve showing the relation between electrical resistance and annealing temperature reaches a minimum; continued annealing at higher temperature produces an increase in the electrical resistance. In the case of alloys it has been noted that a second decrease occurs at higher annealing temperature. The following work corroborates the observance of previous investigations. The electrical resistance of cold worked copper, gold, nickel, and iron decreased with annealing and then increased, the minimum being around 300° C. or 400° C. Monel metal showed a minimum resistance followed by an increase which in turn was followed by a second decrease.
Resumo:
Many investigations have shown that the electrical resistance of soft annealed metals is usually smaller than that of metals in their hard, cold worked state. By annealing cold-worked metals, the electrical resistance decreases to a minimum and then increases upon continued annealing at higher temperatures. The work performed in this investigation upon silver, aluminum, copper, nickel, and soft steel corroborates this idea.
Resumo:
Osteotomies of the proximal femur for hip joint conditions are normally done at the intertrochanteric or subtrochanteric level. Intra-articular osteotomies would be more direct and therefore allow a more powerful correction with no or very little undesired side correction. However, concerns about the risk of vascular damage and osteonecrosis of the femoral head have so far basically excluded this technique from practical use. Based on detailed knowledge of the vascular anatomy of the proximal femur, an approach to safely dislocate the femoral head has been described and successfully performed. Experience as well as further studies of femoral head perfusion allowed a substantial extension of this approach, with subperiosteal exposure of the circumference of the femoral neck with constant intraoperative control of the blood supply to the head. Using the extended retinacular soft-tissue flap, four surgical techniques (relative neck lengthening, subcapital realignment in slipped capital femoral epiphysis, true femoral neck osteotomy, and femoral head reduction osteotomy) evolved or became safer with respect to perfusion of the femoral head. The extended retinacular soft-tissue flap offers the technical and biologic possibility for a new class of intra articular procedures. Although meticulous execution of the surgical steps is important, the procedures have a high level of safety for femoral head perfusion.