956 resultados para impedance spectra
Resumo:
INTRODUCTION: Voluntary muscle activity, including swallowing, decreases during the night. The association between nocturnal awakenings and swallowing activity is under-researched with limited information on the frequency of swallows during awake and asleep periods. AIM: The aim of this study was to assess nocturnal swallowing activity and identify a cut-off predicting awake and asleep periods. METHODS: Patients undergoing impedance-pH monitoring as part of GERD work-up were asked to wear a wrist activity detecting device (Actigraph(®)) at night. Swallowing activity was quantified by analysing impedance changes in the proximal esophagus. Awake and asleep periods were determined using a validated scoring system (Sadeh algorithm). Receiver operating characteristics (ROC) analyses were performed to determine sensitivity, specificity and accuracy of swallowing frequency to identify awake and asleep periods. RESULTS: Data from 76 patients (28 male, 48 female; mean age 56 ± 15 years) were included in the analysis. The ROC analysis found that 0.33 sw/min (i.e. one swallow every 3 min) had the optimal sensitivity (78 %) and specificity (76 %) to differentiate awake from asleep periods. A swallowing frequency of 0.25 sw/min (i.e. one swallow every 4 min) was 93 % sensitive and 57 % specific to identify awake periods. A swallowing frequency of 1 sw/min was 20 % sensitive but 96 % specific in identifying awake periods. Impedance-pH monitoring detects differences in swallowing activity during awake and asleep periods. Swallowing frequency noticed during ambulatory impedance-pH monitoring can predict the state of consciousness during nocturnal periods
Resumo:
OBJECTIVE The objective of the study is to investigate the electrocortical and the global cognitive effects of 3 months rivastigmine medication in a group of mild to moderate Alzheimer's disease patients. MATERIALS AND METHODS Multichannel EEG and cognitive performances measured with the Mini Mental State Examination in a group of 16 patients with mild to moderate Alzheimer's Disease were collected before and 3 months after the onset of rivastigmine medication. RESULTS Spectral analysis of the EEG data showed a significant power decrease in the delta and theta frequency bands during rivastigmine medication, i.e., a shift of the power spectrum towards 'normalization'. Three-dimensional low resolution electromagnetic tomography (LORETA) functional imaging localized rivastigmine effects in a network that includes left fronto-parietal regions, posterior cingulate cortex, bilateral parahippocampal regions, and the hippocampus. Moreover, a correlation analysis between differences in the cognitive performances during the two recordings and LORETA-computed intracortical activity showed, in the alpha1 frequency band, better cognitive performance with increased cortical activity in the left insula. CONCLUSION The results point to a 'normalization' of the EEG power spectrum due to medication, and the intracortical localization of these effects showed an increase of cortical activity in frontal, parietal, and temporal regions that are well-known to be affected in Alzheimer's disease. The topographic convergence of the present results with the memory network proposed by Vincent et al. (J. Neurophysiol. 96:3517-3531, 2006) leads to the speculation that in our group of patients, rivastigmine specifically activates brain regions that are involved in memory functions, notably a key symptom in this degenerative disease.
Resumo:
Transition to psychosis in at-risk individuals has markedly declined in recent years. So far it has never been discussed in detail that with the growing awareness and increasing availability of early psychosis services, a much broader diagnostic spectrum is now being seen in these services. Subsequently, subjects present with symptoms that meet psychosis risk on a purely psychometric basis but may be the phenotypical expression of another underlying mental disorder. Here we critically review four groups of symptoms and clinical features that are frequently reported by individuals with suspected psychosis risk states, yet share strong commonalities with other mental disorders and conditions: isolated hallucinations; unusual bodily perceptions, hypochondriatic fears and cenesthetic psychotic symptoms; depersonalization; obsessive–compulsive, overvalued and delusional ideas. Of the 616 individuals so far assessed in the Bruderholz Early Psychosis Outpatient Service for Adolescents and Young Adults, 218 (30.5%) met ultra-high risk (UHR) criteria, 188 (86.2%) of whom suffered from one of the four above-mentioned symptom groups. The appraisal of the diagnostic spectra and their overlapping symptoms constitute a tremendous challenge in the clinical assessment of each referred individual. The final conclusion of a clinical assessment should not end with the mere assignment – or non-assignment – to a presumed psychosis risk group, but needs to take into account the ‘Gestalt’ of these particular symptoms and clinical features and thus be based on many more facets than solely a psychometric or nosological approach. Such an approach may break down the heterogeneous psychosis risk group and enable appropriate treatment regimes.
Resumo:
Background A recent method determines regional gas flow of the lung by electrical impedance tomography (EIT). The aim of this study is to show the applicability of this method in a porcine model of mechanical ventilation in healthy and diseased lungs. Our primary hypothesis is that global gas flow measured by EIT can be correlated with spirometry. Our secondary hypothesis is that regional analysis of respiratory gas flow delivers physiologically meaningful results. Methods In two sets of experiments n = 7 healthy pigs and n = 6 pigs before and after induction of lavage lung injury were investigated. EIT of the lung and spirometry were registered synchronously during ongoing mechanical ventilation. In-vivo aeration of the lung was analysed in four regions-of-interest (ROI) by EIT: 1) global, 2) ventral (non-dependent), 3) middle and 4) dorsal (dependent) ROI. Respiratory gas flow was calculated by the first derivative of the regional aeration curve. Four phases of the respiratory cycle were discriminated. They delivered peak and late inspiratory and expiratory gas flow (PIF, LIF, PEF, LEF) characterizing early or late inspiration or expiration. Results Linear regression analysis of EIT and spirometry in healthy pigs revealed a very good correlation measuring peak flow and a good correlation detecting late flow. PIFEIT = 0.702 · PIFspiro + 117.4, r2 = 0.809; PEFEIT = 0.690 · PEFspiro-124.2, r2 = 0.760; LIFEIT = 0.909 · LIFspiro + 27.32, r2 = 0.572 and LEFEIT = 0.858 · LEFspiro-10.94, r2 = 0.647. EIT derived absolute gas flow was generally smaller than data from spirometry. Regional gas flow was distributed heterogeneously during different phases of the respiratory cycle. But, the regional distribution of gas flow stayed stable during different ventilator settings. Moderate lung injury changed the regional pattern of gas flow. Conclusions We conclude that the presented method is able to determine global respiratory gas flow of the lung in different phases of the respiratory cycle. Additionally, it delivers meaningful insight into regional pulmonary characteristics, i.e. the regional ability of the lung to take up and to release air.
Resumo:
High Resolution Magic Angle Spinning (HR-MAS) NMR allows metabolic characterization of biopsies. HR-MAS spectra from tissues of most organs show strong lipid contributions that are overlapping metabolite regions, which hamper metabolite estimation. Metabolite quantification and analysis would benefit from a separation of lipids and small metabolites. Generally, a relaxation filter is used to reduce lipid contributions. However, the strong relaxation filter required to eliminate most of the lipids also reduces the signals for small metabolites. The aim of our study was therefore to investigate different diffusion editing techniques in order to employ diffusion differences for separating lipid and small metabolite contributions in the spectra from different organs for unbiased metabonomic analysis. Thus, 1D and 2D diffusion measurements were performed, and pure lipid spectra that were obtained at strong diffusion weighting (DW) were subtracted from those obtained at low DW, which include both small metabolites and lipids. This subtraction yielded almost lipid free small metabolite spectra from muscle tissue. Further improved separation was obtained by combining a 1D diffusion sequence with a T2-filter, with the subtraction method eliminating residual lipids from the spectra. Similar results obtained for biopsies of different organs suggest that this method is applicable in various tissue types. The elimination of lipids from HR-MAS spectra and the resulting less biased assessment of small metabolites have potential to remove ambiguities in the interpretation of metabonomic results. This is demonstrated in a reproducibility study on biopsies from human muscle.
Resumo:
We study the spectral properties of the two-dimensional Dirac operator on bounded domains together with the appropriate boundary conditions which provide a (continuous) model for graphene nanoribbons. These are of two types, namely, the so-called armchair and zigzag boundary conditions, depending on the line along which the material was cut. In the former case, we show that the spectrum behaves in what might be called a classical way; while in the latter, we prove the existence of a sequence of finite multiplicity eigenvalues converging to zero and which correspond to edge states.
Resumo:
BACKGROUND & AIMS: Esophageal impedance measurements have been proposed to indicate the status of the esophageal mucosa, and might be used to study the roles of the impaired mucosal integrity and increased acid sensitivity in patients with heartburn. We compared baseline impedance levels among patients with heartburn who did and did not respond to proton pump inhibitor (PPI) therapy, along with the pathophysiological characteristics of functional heartburn (FH). METHODS: In a case-control study, we collected data from January to December 203 on patients with heartburn and normal findings from endoscopy who were not receiving PPI therapy and underwent impedance pH testing at hospitals in Italy. Patients with negative test results were placed on an 8-week course of PPI therapy (84 patients received esomeprazole and 36 patients received pantoprazole). Patients with more than 50% symptom improvement were classified as FH/PPI responders and patients with less than 50% symptom improvement were classified as FH/PPI nonresponders. Patients with hypersensitive esophagus and healthy volunteers served as controls. In all patients and controls, we measured acid exposure time, number of refluxes, baseline impedance, and swallow-induced peristaltic wave indices. RESULTS: FH/PPI responders had higher acid exposure times, numbers of reflux events, and acid refluxes compared with FH/PPI nonresponders (P < .05). Patients with hypersensitive esophagus had mean acid exposure times and numbers of reflux events similar to those of FH/PPI responders. Baseline impedance levels were lower in FH/PPI responders and patients with hypersensitive esophagus, compared with FH/PPI nonresponders and healthy volunteers (P < .001). Swallow-induced peristaltic wave indices were similar between FH/PPI responders and patients with hypersensitive esophagus. CONCLUSIONS: Patients with FH who respond to PPI therapy have impedance pH features similar to those of patients with hypersensitive esophagus. Baseline impedance measurements might allow for identification of patients who respond to PPIs but would be classified as having FH based on conventional impedance-pH measurements.
Resumo:
The function of the esophagus is transporting nutrients from the oropharyngeal cavity to the stomach. This is achieved by coordinated contractions and relaxation of the tubular esophagus and the upper and lower esophageal sphincter. Multichannel intraluminal impedance monitoring offers quantification of esophageal bolus transit and/or retention without the use of ionizing radiation. Combined with conventional or high-resolution manometry, impedance measurements complement the quantification of esophageal body contraction and sphincter relaxation, offering a more comprehensive evaluation of esophageal function. Further studies evaluating the utility of quantifying bolus transit will help clarify the role and position of impedance measurements.