981 resultados para heart left ventricle enddiastolic pressure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reptiles change heart rate and blood flow patterns in response to heating and cooling, thereby decreasing the behavioural cost of thermoregulation. We tested the hypothesis that locally produced vasoactive substances, nitric oxide and prostaglandins, mediate the cardiovascular response of reptiles to heat. Heart rate and blood pressure were measured in eight crocodiles (Crocodylus porosus) during heating and cooling and while sequentially inhibiting nitric-oxide synthase and cyclooxygenase enzymes. Heart rate and blood pressure were significantly higher during heating than during cooling in all treatments. Power spectral density of heart rate and blood pressure increased significantly during heating and cooling compared to the preceding period of thermal equilibrium. Spectral density of heart rate in the high frequency band (0.19-0.70 Hz) was significantly greater during cooling in the saline treatment compared to when nitric-oxide synthase and cyclooxygenase enzymes were inhibited. Cross spectral analysis showed that changes in blood pressure preceded heart rate changes at low frequencies (

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Characteristics obtained from peripheral pulses can be used to assess the status of cardiovascular system of subjects. However, nonintrusive techniques are preferred when prolonged monitoring is required for their comfort. Pulse transit time ( PTT) measurement has showed its potentials to monitor timing changes in peripheral pulse in cardiovascular and respiratory studies. In children, the common peripheries used for these studies are fingers or toes. Presently, there is no known study conducted on children to investigate the possible physiologic parameters that can confound PTT measure at these sites. In this study, PTT values from both peripheral sites were recorded from 55 healthy Caucasian children ( 39 male) with mean age of 8.4 +/- 2.3 years ( range 5 - 12 years). Peripheries' path length, heart rate, systolic blood pressure, diastolic blood pressure ( DBP) and mean arterial pressure ( MAP) were measured to investigate their contributions to PTT measurement. The results reveal that PTT is significantly related to all parameters ( P< 0.05), except for DBP and MAP. Age is observed to be the dominant factor that affects PTT at both peripheries in a child. Regression equations for PTT were derived for measuring from a finger and toe, ( 6.09 age + 189.2) ms and ( 6.70 age + 243.0) ms, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulse transit time (PTT) is a non-invasive measure, defined as time taken for the pulse pressure waves to travel from the R-wave of electrocardiogram to a selected peripheral site. Baseline PTT value is known to be influenced by physiologic variables like heart rate (HR), blood pressure (BP) and arterial compliance (AC). However, few quantitative data are available describing the factors which can influence PTT measurements in a child during breathing. The aim of this study was to investigate the effects of changes in breathing efforts on PTT baseline and fluctuations. Two different inspiratory resistive loading (IRL) devices were used to simulate loaded breathing in order to induce these effects. It is known that HR can influence the normative PTT value however the effect of HR variability (HRV) is not well-studied. Two groups of 3 healthy children ( 0.05) HR changes during all test activities. Results showed that HRV is not the sole contributor to PTT variations and suggest that changes in other physiologic parameters are also equally important. Hence, monitoring PTT measurement can be indicative of these associated changes during tidal or increased breathing efforts in healthy children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Esophageal intubation is a widely utilized technique for a diverse array of physiological studies, activating a complex physiological response mediated, in part, by the autonomic nervous system (ANS). In order to determine the optimal time period after intubation when physiological observations should be recorded, it is important to know the duration of, and factors that influence, this ANS response, in both health and disease. Methods: Fifty healthy subjects (27 males, median age 31.9 years, range 20-53 years) and 20 patients with Rome III defined functional chest pain (nine male, median age of 38.7 years, range 28-59 years) had personality traits and anxiety measured. Subjects had heart rate (HR), blood pressure (BP), sympathetic (cardiac sympathetic index, CSI), and parasympathetic nervous system (cardiac vagal tone, CVT) parameters measured at baseline and in response to per nasum intubation with an esophageal catheter. CSI/CVT recovery was measured following esophageal intubation. Key Results: In all subjects, esophageal intubation caused an elevation in HR, BP, CSI, and skin conductance response (SCR; all p < 0.0001) but concomitant CVT and cardiac sensitivity to the baroreflex (CSB) withdrawal (all p < 0.04). Multiple linear regression analysis demonstrated that longer CVT recovery times were independently associated with higher neuroticism (p < 0.001). Patients had prolonged CSI and CVT recovery times in comparison to healthy subjects (112.5 s vs 46.5 s, p = 0.0001 and 549 s vs 223.5 s, p = 0.0001, respectively). Conclusions & Inferences: Esophageal intubation activates a flight/flight ANS response. Future studies should allow for at least 10 min of recovery time. Consideration should be given to psychological traits and disease status as these can influence recovery. The psychological trait of neuroticism retards autonomic recovery following esophageal intubation in health and functional chest pain. © 2013 John Wiley & Sons Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent decades, the rapid development of optical spectroscopy for tissue diagnosis has been indicative of its high clinical value. The goal of this research is to prove the feasibility of using diffuse reflectance spectroscopy and fluorescence spectroscopy to assess myocardial infarction (MI) in vivo. The proposed optical technique was designed to be an intra-operative guidance tool that can provide useful information about the condition of an infarct for surgeons and researchers. ^ In order to gain insight into the pathophysiological characteristics of an infarct, two novel spectral analysis algorithms were developed to interpret diffuse reflectance spectra. The algorithms were developed based on the unique absorption properties of hemoglobin for the purpose of retrieving regional hemoglobin oxygenation saturation and concentration data in tissue from diffuse reflectance spectra. The algorithms were evaluated and validated using simulated data and actual experimental data. ^ Finally, the hypothesis of the study was validated using a rabbit model of MI. The mechanism by which the MI was induced was the ligation of a major coronary artery of the left ventricle. Three to four weeks after the MI was induced, the extent of myocardial tissue injury and the evolution of the wound healing process were investigated using the proposed spectroscopic methodology as well as histology. The correlations between spectral alterations and histopathological features of the MI were analyzed statistically. ^ The results of this PhD study demonstrate the applicability of the proposed optical methodology for assessing myocardial tissue damage induced by MI in vivo. The results of the spectral analysis suggest that connective tissue proliferation induced by MI significantly alter the characteristics of diffuse reflectance and fluorescence spectra. The magnitudes of the alterations could be quantitatively related to the severity and extensiveness of connective tissue proliferation.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Un bon fonctionnement du coeur humain est primordial pour maintenir une bonne qualité de vie. Cependant, lorsque le coeur est défaillant, certaines interventions chirurgicales s’avèrent nécessaires pour prolonger l’espérance de vie. Dans le cadre d’un projet multidisciplinaire reliant le génie mécanique avec le domaine biomédical, notre équipe travaille sur la fabrication de valves cardiaques conçues entièrement par génie tissulaire. Pour y parvenir, il est important d’obtenir des propriétés mécaniques optimales pour les tissus biologiques. Afin d’obtenir ces propriétés mécaniques, un outil important a été fabriqué lors d’une étude antérieure : le bioréacteur cardiaque. Le bioréacteur cardiaque permet de reproduire l’environnement physiologique du coeur, notamment les conditions de débit et de pression. Il est crucial de bien contrôler ces conditions, car celles-ci jouent un rôle important lors du conditionnement des substituts valvulaires. Toutefois, il est complexe de contrôler simultanément ces deux conditions de manière efficace. C’est pourquoi notre équipe s’est concentrée sur le développement d’une nouvelle stratégie de contrôle afin que le bioréacteur puisse reproduire le plus fidèlement possible l’environnement physiologique. Plusieurs techniques de contrôle ont été essayés jusqu’à maintenant. Par contre, leur précision était généralement limitée. Une nouvelle approche a donc été envisagée et est présentée dans ce mémoire. Cette nouvelle approche pour le contrôle du bioréacteur est basée sur un type d’algorithme bien connu mais encore très peu utilisé en contrôle : les algorithmes génétiques. Cette approche prometteuse nous a permis de produire des résultats dépassant tous ceux obtenus jusqu’à maintenant pour l’une des deux conditions, soit le débit physiologique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La protéine de liaison aux facteurs de croissance analogues à l’insuline (IGFBP)-2 est une protéine circulante fortement associée à la résistance à l’insuline qui module les effets métaboliques d’IGF-I et IGF-II en s’y associant directement, et qui exerce aussi des actions IGF-indépendantes via sa liaison à la matrice extracellulaire et aux intégrines. Chez l’homme, de faibles niveaux d’IGFBP-2 sont associés à un profil lipidique délétère, ainsi qu’à une augmentation de la masse grasse et de la résistance à l’insuline. Les travaux décrits dans cette thèse montrent chez l’humain et la souris que les niveaux d’IGFBP-2 sont associés de manière indépendante aux composantes du risque cardiométabolique. Chez l’homme, de faibles niveaux d’IGFBP-2 sont associés à la dyslipidémie athérogène. Une valeur seuil d’IGFBP-2 de 221.5 ng/mL a permis de discriminer entre les sujets métaboliquement sains et ceux répondant aux critères du syndrome métabolique. En plus de son association avec la résistance à l’insuline et les composantes du profil lipidique, de faibles niveaux d’IGFBP-2 sont associés à une fonction cardiaque diminuée chez les patients atteints de sténose aortique, tel qu’évaluée par le volume d’éjection indexé, un indice de fonction global du ventricule gauche qui intègre la fonction pompe et le remodelage du tissu. Chez l’homme, des niveaux d’IGFBP-2 élevés sont associés à un tissu adipeux brun plus volumineux ainsi qu’à une activité métabolique plus importante de ce dernier. Ces observations, telles qu’évaluées par PET/CT, sont aussi validées chez les souris surexprimant la forme humaine d’IGFBP-2. Nos travaux démontrent que les niveaux d’IGFBP-2 sont fortement associés au métabolisme des lipoprotéines et des lipides, à la fonction cardiaque ainsi qu’à l’activité du tissu adipeux brun. L’influence des niveaux d’IGFBP-2 par différentes altérations métaboliques menant à l’augmentation du risque cardiométabolique pourrait faire de ce dernier un biomarqueur précoce et intégrateur. Les travaux exposés dans la présente thèse soulignent aussi un rôle mécanistique potentiel pour IGFBP-2 dans la protection contre certaines altérations du métabolisme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Tracheal intubation is extremely distressing, painful, and may influence heart rate and blood pressure. Sedatives, analgesics, and muscle relaxants are not commonly used for intubation in neonates. Objectives: This study aimed to evaluate the effects of lidocaine spray as a non-intravenous drug before neonatal intubation on blood pressure, heart rate, oxygen saturation and time of intubation. Patients and Methods: In a randomized, controlled study each neonate was randomly assigned to one of the two study groups by staffs who were not involved in the infant's care. The allocation concealment was kept in an opaque sealed envelope, and the investigators, the patient care team, and the assessors were blinded to the treatment allocation. The selected setting was NICU unit of a teaching hospital in Ilam city, Iran and participants were 60 neonates with indication of tracheal intubation with gestational age >30 weeks. Patients in the treatment group received lidocaine spray and the placebo group received spray of normal saline prior to intubation. Main outcome measurements were the mean rates of blood pressure, heart rate, oxygen saturation, intubation time and lidocaine side effects were measured before and after intubation. Results: Totally 60 newborns including 31 boys and 29 girls were entered into the study (drug group n = 30; placebo group n = 30). Boy/girl ratio in treatment and placebo groups were 1.3 and 0.88, respectively. Mean age ± SD of participants was 34.1 ± 24.8 hours (treatment: 35.3 ± 25.7; placebo: 32.9 ± 24.3; P < 0.0001). Mean weight ± SD of neonates was 2012.5 ± 969 g. Application of lidocaine spray caused a significant reduction of mean intubation time among treatment group compared with placebo group (treatment: 15.03 ± 2.2 seconds; placebo: 18.3 ± 2.3 seconds; P < 0.0001). Mean blood pressure, heart rate and oxygen saturation rate, among neonates in treatment group was reduced after intubation compared with their relevant figures before intubation; however, their differences were not statistically significant except for mean oxygen saturation rate that was reduced significantly in placebo group. No side effects were observed during study. Conclusions: Though the current study revealed some promising results in the application of lidocaine spray during neonatal intubation without any considerable side effects; however, the current investigation could only be considered as a pilot study for further attempts in different locations with higher sample sizes and in different situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Study Rationale Being physically active is a major contributor to both physical and mental health. More specifically, being physically active lowers risk of coronary heart disease, high blood pressure, stroke, metabolic syndrome (MetS), diabetes, certain cancers and depression, and increases cognitive function and wellbeing. The physiological mechanisms that occur in response to physical activity and the impact of total physical activity and sedentary behaviour on cardiometabolic health have been extensively studied. In contrast, limited data evaluating the specific effects of daily and weekly patterns of physical behaviour on cardiometabolic health exist. Additionally, no other study has examined interrelated patterns and minute-by-minute accumulation of physical behaviour throughout the day across week days in middle-aged adults. Study Aims The overarching aims of this thesis are firstly to describe patterns of behaviour throughout the day and week, and secondly to explore associations between these patterns and cardiometabolic health in a middle-aged population. The specific objectives are to: 1 Compare agreement between the International Physical Activity Questionnaire-Short Form (IPAQ-SF) and GENEActiv accelerometer-derived moderate-to-vigorous (MVPA) activity and secondly to compare their associations with a range of cardiometabolic and inflammatory markers in middle-aged adults. 2 Determine a suitable monitoring frame needed to reliably capture weekly, accelerometer-measured, activity in our population. 3 Identify groups of participants who have similar weekly patterns of physical behaviour, and determine if underlying patterns of cardiometabolic profiles exist among these groups. 4 Explore the variation of physical behaviour throughout the day to identify whether daily patterns of physical behaviour vary by cardiometabolic health. Methods All results in this thesis are based on data from a subsample of the Mitchelstown Cohort; 475 (46.1% males; mean aged 59.7±5.5 years) middle-aged Irish adults. Subjective physical activity levels were assessed using the IPAQ-SF. Participants wore the wrist GENEActiv accelerometer for 7 consecutive days. Data was collected at 100Hz and summarised into a signal magnitude vector using 60s epochs. Each time interval was categorised based on validated cut-offs. Data on cardiometabolic and inflammatory markers was collected according to standard protocol. Cardiometabolic outcomes (obesity, diabetes, hypertension and MetS) were defined according to internationally recognised definitions by World Health Organisation (WHO) and Irish Diabetes Federation (IDF). Results The results of the first chapter suggest that the IPAQ-SF lacks the sensitivity to assess patterning of activity and guideline adherence and assessing the relationship with cardiometabolic and inflammatory markers. Furthermore, GENEActiv accelerometer-derived MVPA appears to be better at detecting relationships with cardiometabolic and inflammatory markers. The second chapter examined variations in day-to-day physical behaviour levels between- and within-subjects. The main findings were that Sunday differed from all other days in the week for sedentary behaviour and light activity and that a large within-subject variation across days of the week for vigorous activity exists. Our data indicate that six days of monitoring, four weekdays plus Saturday and Sunday, are required to reliably estimate weekly habitual activity in all activity intensities. In the next chapter, latent profile analysis of weekly, interrelated patterns of physical behaviour identified four distinct physical behaviour patterns; Sedentary Group (15.9%), Sedentary; Lower Activity Group (28%), Sedentary; Higher Activity Group (44.2%) and a Physically Active Group (11.9%). Overall the Sedentary Group had poorer outcomes, characterised by unfavourable cardiometabolic and inflammatory profiles. The remaining classes were characterised by healthier cardiometabolic profiles with lower sedentary behaviour levels. The final chapter, which aimed to compare daily cumulative patterns of minute-by-minute physical behaviour intensities across those with and without MetS, revealed significant differences in weekday and weekend day MVPA. In particular, those with MetS start accumulating MVPA later in the day and for a shorted day period. Conclusion In conclusion, the results of this thesis add to the evidence base regards an optimal monitoring period for physical behaviour measurement to accurately capture weekly physical behaviour patterns. In addition, the results highlight whether weekly and daily distribution of activity is associated with cardiometabolic health and inflammatory profiles. The key findings of this thesis demonstrate the importance of daily and weekly physical behaviour patterning of activity intensity in the context of cardiometabolic health risk. In addition, these findings highlight the importance of using physical behaviour patterns of free-living adults observed in a population-based study to inform and aid health promotion activity programmes and primary care prevention and treatment strategies and development of future tailored physical activity based interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The impact of intravenous (IV) beta-blockers before primary percutaneous coronary intervention (PPCI) on infarct size and clinical outcomes is not well established. This study sought to conduct the first double-blind, placebo-controlled international multicenter study testing the effect of early IV beta-blockers before PPCI in a general ST-segment elevation myocardial infarction (STEMI) population. STEMI patients presenting <12 h from symptom onset in Killip class I to II without atrioventricular block were randomized 1:1 to IV metoprolol (2 × 5-mg bolus) or matched placebo before PPCI. Primary endpoint was myocardial infarct size as assessed by cardiac magnetic resonance imaging (CMR) at 30 days. Secondary endpoints were enzymatic infarct size and incidence of ventricular arrhythmias. Safety endpoints included symptomatic bradycardia, symptomatic hypotension, and cardiogenic shock. A total of 683 patients (mean age 62 ± 12 years; 75% male) were randomized to metoprolol (n = 336) or placebo (n = 346). CMR was performed in 342 patients (54.8%). Infarct size (percent of left ventricle [LV]) by CMR did not differ between the metoprolol (15.3 ± 11.0%) and placebo groups (14.9 ± 11.5%; p = 0.616). Peak and area under the creatine kinase curve did not differ between both groups. LV ejection fraction by CMR was 51.0 ± 10.9% in the metoprolol group and 51.6 ± 10.8% in the placebo group (p = 0.68). The incidence of malignant arrhythmias was 3.6% in the metoprolol group versus 6.9% in placebo (p = 0.050). The incidence of adverse events was not different between groups. In a nonrestricted STEMI population, early intravenous metoprolol before PPCI was not associated with a reduction in infarct size. Metoprolol reduced the incidence of malignant arrhythmias in the acute phase and was not associated with an increase in adverse events.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT Background Cardiac magnetic resonance (CMR) has been shown as promising diagnostic tool in Anderson-Fabry disease (AFD) cardiomyopathy due to its ability to detect fat deposits through lower native T1 values. However no histological validation has been provided to date. Objectives To correlate CMR and histologic findings in different cardiac stages of AFD focusing on T1 mapping. Methods Fifteen AFD patients (49 years [IQR 39-63], 60% females) undergoing CMR (cines, native T1 and T2 mapping, LGE and post-contrast T1 imaging) and endomyocardial biopsy (EMB, n=11) or septal myectomy (n=4), were retrospectively evaluated. Tissue specimens were analyzed with light/electron microscopy and vacuolization amount calculated as percentages of vacuolated myocytes and vacuolated myocyte area (%VMA) through a quantitative histomorphometric color-based analysis. Results In patients without increased indexed left ventricular mass (LVMi) at CMR (67%), T1 fell as %VMA increased (r= -0.883; p<0.001), whereas no clear relationship was evident once increased LVMi occurred (r= -0.501; p=0.389). At least 45% of vacuolized myocytes and 10% of VMA were needed for low T1 to occur. %VMA positively correlate with maximal wall thickness (MWT, r=0.860, p<0.0001) and LVMi (r= 0.762; p<0.001). Increased MWT and LVMi were present with at least 45% and 80% of vacuolated myocytes, respectively, and 18% and 22% of VMA. Conclusions This study demonstrated an inverse correlation between native T1 and the vacuolization amount in patients without increased LVMi at CMR, providing a histological validation of low native T1 in AFD. Importantly, a significant vacuolization burden was needed before low T1 and left ventricle hypertrophy occurred.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cardiovascular responses to central losartan (LOS), a non-peptide angiotensin II (ANG II) receptor antagonist, were investigated by comparing the effects of LOS injection into the 3rd and 4th cerebral ventricles (3rdV, 4thV) on mean arterial pressure (MAP) and heart rate (HR). Adult male Holtzman rats were used (N = 6 animals per group). Average basal MAP and HR were 114 +/- 3 mmHg and 343 +/- 9 bpm (N = 23), respectively. LOS (50, 100 or 200 nmol/2 mu l) injected into the 3rdV induced presser (peak of 25 +/- 3 mmHg) and tachycardic (peak of 60 +/- 25 bpm) responses. LOS injected into the 4thV had no effect on MAP, but it induced bradycardia (peak of -35 +/- 15 bpm). KCl (200 nmol/2 mu l) injected into the 3rdV or into the 4thV had no effect on either MAP or HR compared to 0.9% saline injection. The results indicate that LOS injected into the third ventricle acts on forebrain structures to induce its presser and tachycardic effects and that bradycardia, likely dependent on hindbrain structures, is obtained when LOS is injected into the fourth ventricle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cardiovascular responses to central losartan (LOS), a non-peptide angiotensin II (ANG II) receptor antagonist, were investigated by comparing the effects of LOS injection into the 3rd and 4th cerebral ventricles (3rdV, 4thV) on mean arterial pressure (MAP) and heart rate (HR). Adult male Holtzman rats were used (N=6 animals per group). Average basal MAP and HR were 114±3 mmHg and 343±9 bpm (N=23), respectively. LOS (50, 100 or 200 nmol/2 μl) injected into the 3rdV induced pressor (peak of 25±3 mmHg) and tachycardic (peak of 60±25 bpm) responses. LOS injected into the 4thV had no effect on MAP, but it induced bradycardia (peak of -35±15 bpm). KCl (200 nmol/2 μl) injected into the 3rdV or into the 4thV had no effect on either MAP or HR compared to 0.9% saline injection. The results indicate that LOS injected into the third ventricle acts on forebrain structures to induce its pressor and tachycardic effects and that bradycardia, likely dependent on hindbrain structures, is obtained when LOS is injected into the fourth ventricle.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The `biomimetic` approach to tissue engineering usually involves the use of a bioreactor mimicking physiological parameters whilst supplying nutrients to the developing tissue. Here we present a new heart valve bioreactor, having as its centrepiece a ventricular assist device (VAD), which exposes the cell-scaffold constructs to a wider array of mechanical forces. The pump of the VAD has two chambers: a blood and a pneumatic chamber, separated by an elastic membrane. Pulsatile air-pressure is generated by a piston-type actuator and delivered to the pneumatic chamber, ejecting the fluid in the blood chamber. Subsequently, applied vacuum to the pneumatic chamber causes the blood chamber to fill. A mechanical heart valve was placed in the VAD`s inflow position. The tissue engineered (TE) valve was placed in the outflow position. The VAD was coupled in series with a Windkessel compliance chamber, variable throttle and reservoir, connected by silicone tubings. The reservoir sat on an elevated platform, allowing adjustment of ventricular preload between 0 and 11 mmHg. To allow for sterile gaseous exchange between the circuit interior and exterior, a 0.2 mu m filter was placed at the reservoir. Pressure and flow were registered downstream of the TE valve. The circuit was filled with culture medium and fitted in a standard 5% CO(2) incubator set at 37 degrees C. Pressure and flow waveforms were similar to those obtained under physiological conditions for the pulmonary circulation. The `cardiomimetic` approach presented here represents a new perspective to conventional biomimetic approaches in TE, with potential advantages. Copyright (C) 2010 John Wiley & Sons, Ltd.