941 resultados para harmonic mean
Resumo:
The classical harmonic oscillator and an elementary discussion of the quantum mechanical solutions for the harmonic oscillator are discussed.
Resumo:
The guessing of eigenfunctions is not trivial at higher quantum numbers, no matter what the system being considered. Instead of guessing, one can employ a symbolic calculus progam (Maple in this case) to aid in the reasoning process.
Resumo:
The Frobenius solution to the differential equations associated with the harmonic oscillator (QM) is carried out in detail.
Resumo:
This is a set of P. Chem. problems posed at slightly higher than the normal text book level, for students who are continuing in the study of this subject.
Resumo:
This is the third paper in a four-part series considering the fundamental question, “what does the word “height” really mean?” The first paper reviewed reference ellipsoids and mean sea level datums. The second paper reviewed the physics of heights culminating in a simple development of the geoid and explained why mean sea level stations are not all at the same orthometric height. This third paper develops the principle notions of height, namely measured, differentially deduced changes in elevation, orthometric heights, Helmert orthometric heights, normal orthometric heights, dynamic heights, and geopotential numbers. We conclude with a more in-depth discussion of current thoughts regarding the geoid.
Resumo:
The molecular dynamical simulation of the normal vibrational mode of water which involves H-O-H angle deformation, when driven by an external force, can be used to see how a driven harmonic oscillator, classically, is associated with the infra-red spectrum of water (and the absorption for this particular normal mode).
Resumo:
The HCl molecule is simulated (using Maple) in its dynamics, for both vibrational (and implied) rotational motions. A discussion of the center of mass transformations involved is part of the total presentation.
Resumo:
Mean corpuscular volume, which is an inexpensive and widely available measure to assess, increases in HIV infected individuals receiving zidovudine and stavudine raising the hypothesis that it could be used as a surrogate for adherence.^ The aim of this study was to examine the association between mean corpuscular volume and adherence to antiretroviral therapy among HIV infected children and adolescents aged 0–19 years in Uganda as well as the extent to which changes in mean corpuscular volume predict adherence as determined by virologic suppression.^ The investigator retrospectively reviewed and analyzed secondary data of 158 HIV infected children and adolescents aged 0–19 years who initiated antiretroviral therapy under an observational cohort at the Baylor College of Medicine Children's Foundation - Uganda. Viral suppression was used as the gold standard for monitoring adherence and defined as viral load of < 400 copies/ml at 24 and 48 weeks. ^ Patients were at least 48 weeks on therapy, age 0.2–18.4 years, 54.4% female, 82.3% on zidovudine based regimen, 92% WHO stage III at initiation of therapy, median pre therapy MCV 80.6 fl (70.3–98.3 fl), median CD4% 10.2% (0.3%–28.0%), and mean pre therapy viral load 407,712.9 ± 270,413.9 copies/ml. For both 24 and 48 weeks of antiretroviral therapy, patients with viral suppression had a greater mean percentage change in mean corpuscular volume (15.1% ± 8.4 vs. 11.1% ± 7.8 and 2.3% ± 13.2 vs. -2.7% ± 10.5 respectively). The mean percentage change in mean corpuscular volume was greater in the first 24 weeks of therapy for patients with and without viral suppression (15.1% ± 8.4 vs. 2.3% ± 13.2 and 11.1% ± 7.8 vs. -2.7% ± 10.5 respectively). In the multivariate logistic regression model, percentage change in mean corpuscular volume ≥ 20% was significantly associated with viral suppression (adjusted OR 4.0; CI 1.2–13.3; p value 0.02). The ability of percentage changes in MCV to correctly identify children and adolescents with viral suppression was higher at a cut off of ≥ 20% (90.7%; sensitivity, 31.7%) than at ≥ 9% (82.9%; sensitivity, 78.9%). Negative predictive value was lower at ≥ 20% change (25%; specificity, 84.8%) than at ≥ 9% change (33.3%; specificity, 39.4%).^ Mean corpuscular volume is a useful marker of adherence among children and adolescents with viral suppression. ^
Resumo:
Objective. Loud noises in neonatal intensive care units (NICUs) may impede growth and development for extremely low birthweight (ELBW, < 1000 grams) newborns. The objective of this study was to measure the association between NICU sound levels and ELBW neonates' arterial blood pressure to determine whether these newborns experience noise-induced stress. ^ Methods. Noise and arterial blood pressure recordings were collected for 9 ELBW neonates during the first week of life. Sound levels were measured inside the incubator, and each subject's arterial blood pressures were simultaneously recorded for 15 minutes (at 1 sec intervals). Time series cross-correlation functions were calculated for NICU noise and mean arterial blood pressure (MABP) recordings for each subject. The grand mean noise-MABP cross-correlation was calculated for all subjects and for lower and higher birthweight groups for comparison. ^ Results. The grand mean noise-MABP cross-correlation for all subjects was mostly negative (through 300 sec lag time) and nearly reached significance at the 95% level at 111 sec lag (mean r = -0.062). Lower birthweight newborns (454-709 g) experienced significant decreases in blood pressure with increasing NICU noise after 145 sec lag (peak r = -0.074). Higher birthweight newborns had an immediate negative correlation with NICU sound levels (at 3 sec lag, r = -0.071), but arterial blood pressures increased to a positive correlation with noise levels at 197 sec lag (r = 0.075). ^ Conclusions. ELBW newborns' arterial blood pressure was influenced by NICU noise levels during the first week of life. Lower birthweight newborns may have experienced an orienting reflex to NICU sounds. Higher birthweight newborns experienced an immediate orienting reflex to increasing sound levels, but arterial blood pressure increased approximately 3 minutes after increases in noise levels. Increases in arterial blood pressure following increased NICU sound levels may result from a stress response to noise. ^
Resumo:
A large number of ridge regression estimators have been proposed and used with little knowledge of their true distributions. Because of this lack of knowledge, these estimators cannot be used to test hypotheses or to form confidence intervals.^ This paper presents a basic technique for deriving the exact distribution functions for a class of generalized ridge estimators. The technique is applied to five prominent generalized ridge estimators. Graphs of the resulting distribution functions are presented. The actual behavior of these estimators is found to be considerably different than the behavior which is generally assumed for ridge estimators.^ This paper also uses the derived distributions to examine the mean squared error properties of the estimators. A technique for developing confidence intervals based on the generalized ridge estimators is also presented. ^