966 resultados para flat spot
Resumo:
This work is motivated in providing and evaluating a fusion algorithm of remotely sensed images, i.e. the fusion of a high spatial resolution panchromatic image with a multi-spectral image (also known as pansharpening) using the dual-tree complex wavelet transform (DT-CWT), an effective approach for conducting an analytic and oversampled wavelet transform to reduce aliasing, and in turn reduce shift dependence of the wavelet transform. The proposed scheme includes the definition of a model to establish how information will be extracted from the PAN band and how that information will be injected into the MS bands with low spatial resolution. The approach was applied to Spot 5 images where there are bands falling outside PAN’s spectrum. We propose an optional step in the quality evaluation protocol, which is to study the quality of the merger by regions, where each region represents a specific feature of the image. The results show that DT-CWT based approach offers good spatial quality while retaining the spectral information of original images, case SPOT 5. The additional step facilitates the identification of the most affected regions by the fusion process.
Resumo:
Many of the material models most frequently used for the numerical simulation of the behavior of concrete when subjected to high strain rates have been originally developed for the simulation of ballistic impact. Therefore, they are plasticity-based models in which the compressive behavior is modeled in a complex way, while their tensile failure criterion is of a rather simpler nature. As concrete elements usually fail in tensión when subjected to blast loading, available concrete material models for high strain rates may not represent accurately their real behavior. In this research work an experimental program of reinforced concrete fíat elements subjected to blast load is presented. Altogether four detonation tests are conducted, in which 12 slabs of two different concrete types are subjected to the same blast load. The results of the experimental program are then used for the development and adjustment of numerical tools needed in the modeling of concrete elements subjected to blast.
Resumo:
Acciona Energía dispone en Alemania de 150 MW de potencia instalada. Todos ellos de energía eólica, en un total de doce parques eólicos situados en la sur del país. El proyecto tiene por objeto comparar las distintas modalidades de venta de energía procedente de fuentes renovables que ofrece el estado alemán para la cartera de activos de Acciona Energía, llegando a una conclusión final de cuál de ellas es la más aconsejable. Para ello se ha realizado un estudio del funcionamiento y normas del mercado Epex Spot de la electricidad y de la legislación alemana correspondiente a la materia, así como un seguimiento exhaustivo de producción y otras variables de los parques eólicos para su análisis. Los cálculos y las estimaciones realizados llevaron a la conclusión, que la mejor opción era la venta directa en el mercado Epex Spot, para lo que primero habría que darse de alta como agente en dicho mercado. Aunque esta opción asuma mayores riesgos también ofrecería un aumento considerable de ingresos. ABSTRACT Acciona Energía has 150 MW of power capacity in Germany, all of them wind energy in a total of twelve installations, located in the south of the country. The main goal of the project is to compare the different ways to sell the energy which became from renewable source that German state offers for Acciona’s asset portfolio, finding the most advisable conclusion. To do so a study of standards and rules of Epex Spot electricity market and German law related to this topic has been made. In addition of an exhaustive monitoring of energy production and others wind farms variables has been analyzed. The reckoning and estimations saw the conclusion that the best option was the direct sell in Epex Spot market, in order to do that the first of all is to register as market agent. Despite this options assume bigger risks, it provide a substantial increase in income
Resumo:
This paper investigates the effective width of reinforced concrete flat slab structures subjected to seismic loading on the basis of dynamic shaking table tests. The study is focussed on the behavior of corner slab? column connections with structural steel I- or channel-shaped sections (shearheads) as shear punching reinforcement. To this end, a 1/2 scale test model consisting of a flat slab supported on four box-type steel columns was subjected to several seismic simulations of increasing intensity. It is found from the test results that the effective width tends to increase with the intensity of the seismic simulation, and this increase is limited by the degradation of adherence between reinforcing steel and concrete induced by the strain reversals caused by the earthquake. Also, significant differences are found between the effective width obtained from the tests and the values predicted by formula proposed in the literature. These differences are attributed to the stiffening effect provided by the steel profiles that constitute the punching shear reinforcement.
Resumo:
Use of computational fluid dynamic (CFD) methods to predict the power production from wind entire wind farms in flat and complex terrain is presented in this paper. Two full 3D Navier–Stokes solvers for incompressible flow are employed that incorporate the k–ε and k–ω turbulence models respectively. The wind turbines (W/Ts) are modelled as momentum absorbers by means of their thrust coefficient using the actuator disk approach. The WT thrust is estimated using the wind speed one diameter upstream of the rotor at hub height. An alternative method that employs an induction-factor based concept is also tested. This method features the advantage of not utilizing the wind speed at a specific distance from the rotor disk, which is a doubtful approximation when a W/T is located in the wake of another and/or the terrain is complex. To account for the underestimation of the near wake deficit, a correction is introduced to the turbulence model. The turbulence time scale is bounded using the general “realizability” constraint for the turbulent velocities. Application is made on two wind farms, a five-machine one located in flat terrain and another 43-machine one located in complex terrain. In the flat terrain case, the combination of the induction factor method along with the turbulence correction provides satisfactory results. In the complex terrain case, there are some significant discrepancies with the measurements, which are discussed. In this case, the induction factor method does not provide satisfactory results.