953 resultados para extraction method
Resumo:
Mercury is not an essential element for plant or animal life and it is a potential environmental toxic because of its tendency to form covalent bonds with organic molecules and the high stability of the Hg-C bond. Reports estimate a total mercury concentration in natural waters ranging from 0.2 to 100 ng L-1. Due to this fact, highly sensitive methods are required for direct determination of such extremely low levels. In this work, a rapid and simple method was developed for separation and preconcentration of mercury by flow injection solid phase extraction coupled with on-line chemical vapour generation electrothermal atomic absorption spectrometry. The system is based on chelating retention of the analyte onto the mini column filled with a mesoporous silica functionalized with 1,5 bis (di-2-pyridyl) methylene thiocarbohydrazide. The main aim of this work was to develop a precise and accurate method for the determination of the Hg. Under the optima conditions and 120 s preconcentration time, the detection limit obtained was 0.009 μg L-1, with RSDs 3.7 % for 0.2 μg L-1, 4.8 % for 1 μg L-1 and enrichment factor 4, Furthermore, the method proposed has permitted the determination of Hg with a reduction in the analysis time, the sample throughput was about 18 h-1, low consumption of reagents and sample volume. The method was applied to the determination of Hg in sea water and river water. For the quality control of the analytical performance and the validation of the newly developed method, the analysis of two certified samples, TMDA 54.4 Fortified Lake, and LGC6187 River sediment was addressed. The results showed good agreement with the certified values.
Resumo:
A simple method developed for genomic DNA isolation from fungus was tested on the red alga, Gelidium sesquipedale (Clem.) Born et Thur., which is commercially exploited for its high sulfated polysaccharide (agar) content. This method is faster, cheaper, and less toxic than conventional phenol/chloroform methods. Random amplified polymorphic DNA (RAPD) amplifications were performed successfully without the necessity of purifying the DNA. RAPD markers were used to investigate the genetic similarity among three natural populations of G. sesquipedale from southern Portugal. Bulked-genomic DNA samples of 15 different individuals were made in each population. These can be conceived of as a sample of the population DNA. Of the 62 primers screened, 41 produced bands and 22 revealed polymorphisms. Genetic similarities among populations were high. Populations that are further away from each other have the lowest similarity coefficients, whereas the intermediate Ingrina population, located on the south coast, showed higher genetic similarity with the Odeceixe population located on the southwest coast, than with the Sao Rafael southern population. This suggests a higher genetic flow between Odeceixe and Ingrina or the result may be a founder effect in the sense that the species has propagated from the east coast to the south coast of Portugal. We conclude that the use of this isolation method with RAPD analysis is appropriate to characterize the genetic variability of this commercial species along its geographical distribution. Large sample sizes can be screened at a relatively low cost. Finding genetic markers for commercial populations of C. sesquipedale may be of industrial interest.
Resumo:
Pseudokirchneriella subcapitata is a unicellular green algae widely distributed in freshwater and soils. Due to its cosmopolitan characteristic, its use is recommended by national and international protocols in ecotoxicity studies. The alteration of phosphatase activities by agriculture pollutants like heavy metals has been extensively used as a biomarker in risk assessment and biomonitoring. In this study, we compared the extraction of acid phosphatase from P. subcapitata by different procedures and we studied the stability, substrates specificity, kinetics and the effect of Hg2+ in the crude extract. The freezing and thawing technique associated with probe sonication was the most suitable method of extraction. The enzyme was stable when frozen at -20ºC for at least six months, showed an optimum pH of 5 and a Km value of 0.27 mM for p-nitrophenylphosphate (pNPP) as substrate. Some natural organic substrates were cleaved by a similar extent as the synthetic substrate pNPP. Short term exposure (24 hours) to Hg2+ had little effect but inhibition of the specific activity was observed after 7 days with EC50 (concentration of Hg2+ that promotes 50% decrease of specific activity) value of 12.63 μM Hg2+ .
Resumo:
A better method for determination of shikimate in plant tissues is needed to monitor exposure of plants to the herbicide glyphosate [N-(phosphonomethyl)glycine] and to screen the plant kingdom for high levels of this valuable phytochemical precursor to the pharmaceutical oseltamivir. A simple, rapid, and efficient method using microwave-assisted extraction (MWAE) with water as the extraction solvent was developed for the determination of shikimic acid in plant tissues. High performance liquid chromatography was used for the separation of shikimic acid, and chromatographic data were acquired using photodiode array detection. This MWAE technique was successful in recovering shikimic acid from a series of fortified plant tissues at more than 90% efficiency with an interference-free chromatogram. This allowed the use of lower amounts of reagents and organic solvents, reducing the use of toxic and/or hazardous chemicals, as compared to currently used methodologies. The method was used to determine the level of endogenous shikimic acid in several species of Brachiaria and sugarcane (Saccharum officinarum) and on B. decumbens and soybean (Glycine max) after treatment with glyphosate. The method was sensitive, rapid and reliable in all cases.
Resumo:
A simple method developed for genomic DNA isolation from fungus was tested on the red alga, Gelidium sesquipedale (Clem.) Born et Thur., which is commercially exploited for its high sulfated polysaccharide (agar) content. This method is faster, cheaper, and less toxic than conventional phenol/chloroform methods. Random amplified polymorphic DNA (RAPD) amplifications were performed successfully without the necessity of purifying the DNA. RAPD markers were used to investigate the genetic similarity among three natural populations of G. sesquipedale from southern Portugal. Bulked-genomic DNA samples of 15 different individuals were made in each population. These can be conceived of as a sample of the population DNA. Of the 62 primers screened, 41 produced bands and 22 revealed polymorphisms. Genetic similarities among populations were high. Populations that are further away from each other have the lowest similarity coefficients, whereas the intermediate Ingrina population, located on the south coast, showed higher genetic similarity with the Odeceixe population located on the southwest coast, than with the Sao Rafael southern population. This suggests a higher genetic flow between Odeceixe and Ingrina or the result may be a founder effect in the sense that the species has propagated from the east coast to the south coast of Portugal. We conclude that the use of this isolation method with RAPD analysis is appropriate to characterize the genetic variability of this commercial species along its geographical distribution. Large sample sizes can be screened at a relatively low cost. Finding genetic markers for commercial populations of C. sesquipedale may be of industrial interest.
Resumo:
Extracellular iron reduction has been suggested as a candidate metabolic pathway that may explain a large proportion of carbon respiration in temperate peatlands. However, the o-phenanthroline colorimetric method commonly employed to quantitate iron and partition between redox species is known to be unreliable in the presence of humic and fulvic acids, both of which represent a considerable proportion of peatland dissolved organic matter. We propose ionic liquid extraction as a more accurate iron quantitation and redox speciation method in humic-rich peat porewater. We evaluated both o-phenanthroline and ionic liquid extraction in four distinct peatland systems spanning a gradient of physico-chemical conditions to compare total iron recovery and Fe2+:Fe3+ ratios determined by each method. Ionic liquid extraction was found to provide more accurate iron quantitation and speciation in the presence of dissolved organic matter. A multivariate approach utilizing fluorescence- and UV-Vis spectroscopy was used to identify dissolved organic matter characteristics in peat porewater that lead to poor performance of the o-phenanthroline method. Where these interferences are present, we offer an empirical correction factor for total iron quantitation by o-phenanthroline, as verified by ionic liquid extraction. The written work presented in this thesis is in preparation for submission to Soil Biology and Biochemisrty by T.J. Veverica, E.S. Kane, A.M. Marcarelli, and S.A. Green.
Resumo:
Strawberries are an important source of phytochemicals, namely vitamins and phenolic compounds such as anthocyanins and tannins with antioxidant properties [1]. The yield and phenolic content of natural extracts are dependent on the conditions used for extraction [2]. In the present work three different types of extracting solutions (methanol, ethanol:water and aceton:water), two times of extraction (15 and 60 min) and three ratios of solid/solvent (5/25, 5/50 and 5/100 g/mL) were tested in order to evaluate the efficiency of the extraction of phenolic compounds. Phenolic compounds were determined by Folin-Ciocalteu method [3]. Each assay was performed in triplicate. Regarding the extraction solution, it was possible to observe a slight tendency towards a higher efficiency of acetone:water (AcO:H2O, 60:40), but the differences mioght not be statistically significant. A longer time of contact, 60 min as opposed to 15 min, did not show advantages in the yield of extraction. Considering the factors under study, the results obtained showed that volume of extraction solution was the parameter that most influenced the values obtained. Using a higher volume lead to an increase in the amount of phenolic compounds extracted, in a more pronounced way for 15 min of extraction. For a volume of 25 mL the amount of phenolic compounds quantified ranged from 2.13-2.41 mg GAE/g, and increased 30-68% when it was used 50 mL of solution. Using 100 mL of solution, it was extracted twice as double of phenolic compounds. In case of 60 min, the amount of phenolic compounds quantified in samples obtained with 25 mL of solution ranged from 2.32-2.97 mg GAE/g, and increased for 2.43-4.27 mg GAE/g and 3.98-4.68 mg GAE/g when was used 50 and 100 mL, respectively.
Resumo:
The formation of reactive oxygen species (ROS) within cells causes damage to biomolecules, including membrane lipids, DNA, proteins and sugars. An important type of oxidative damage is DNA base hydroxylation which leads to the formation of 8-oxo-7,8-dihydro-29-deoxyguanosine (8-oxodG) and 5-hydroxymethyluracil (5-HMUra). Measurement of these biomarkers in urine is challenging, due to the low levels of the analytes and the matrix complexity. In order to simultaneously quantify 8-oxodG and 5-HMUra in human urine, a new, reliable and powerful strategy was optimised and validated. It is based on a semi-automatic microextraction by packed sorbent (MEPS) technique, using a new digitally controlled syringe (eVolH), to enhance the extraction efficiency of the target metabolites, followed by a fast and sensitive ultrahigh pressure liquid chromatography (UHPLC). The optimal methodological conditions involve loading of 250 mL urine sample (1:10 dilution) through a C8 sorbent in a MEPS syringe placed in the semi-automatic eVolH syringe followed by elution using 90 mL of 20% methanol in 0.01% formic acid solution. The obtained extract is directly analysed in the UHPLC system using a binary mobile phase composed of aqueous 0.1% formic acid and methanol in the isocratic elution mode (3.5 min total analysis time). The method was validated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), extraction yield, accuracy, precision and matrix effect. Satisfactory results were obtained in terms of linearity (r2 . 0.991) within the established concentration range. The LOD varied from 0.00005 to 0.04 mg mL21 and the LOQ from 0.00023 to 0.13 mg mL21. The extraction yields were between 80.1 and 82.2 %, while inter-day precision (n=3 days) varied between 4.9 and 7.7 % and intra-day precision between 1.0 and 8.3 %. This approach presents as main advantages the ability to easily collect and store urine samples for further processing and the high sensitivity, reproducibility, and robustness of eVolHMEPS combined with UHPLC analysis, thus retrieving a fast and reliable assessment of oxidatively damaged DNA.
Resumo:
The production of olive oil generates several by-products that can be seen as an additional business opportunity. Among them are the olive pits, already used for heat and/or electricity generation in some mills. They contain compounds that are commercially very interesting and, if recovered, contribute to the sustainability of the olive mills. The work presented in this paper is a preliminary evaluation of the economic feasibility of implementing a system based on a batch prototype with 1 m3 for the extraction of high value-added bioactive molecules from olive pits that are separated during the production of virgin olive oil. For the analysis, a small representative olive mill in Portugal was considered and the traditional Discounted Cash Flow Method was applied. Based on the assumptions made, the simple payback for implementation a system for the extraction of value-added molecules from the olive pits is around 7 years.
Resumo:
To detect the presence of male DNA in vaginal samples collected from survivors of sexual violence and stored on filter paper. A pilot study was conducted to evaluate 10 vaginal samples spotted on sterile filter paper: 6 collected at random in April 2009 and 4 in October 2010. Time between sexual assault and sample collection was 4-48hours. After drying at room temperature, the samples were placed in a sterile envelope and stored for 2-3years until processing. DNA extraction was confirmed by polymerase chain reaction for human β-globin, and the presence of prostate-specific antigen (PSA) was quantified. The presence of the Y chromosome was detected using primers for sequences in the TSPY (Y7/Y8 and DYS14) and SRY genes. β-Globin was detected in all 10 samples, while 2 samples were positive for PSA. Half of the samples amplified the Y7/Y8 and DYS14 sequences of the TSPY gene and 30% amplified the SRY gene sequence of the Y chromosome. Four male samples and 1 female sample served as controls. Filter-paper spots stored for periods of up to 3years proved adequate for preserving genetic material from vaginal samples collected following sexual violence.
Resumo:
In the current study, a new approach has been developed for correcting the effect that moisture reduction after virgin olive oil (VOO) filtration exerts on the apparent increase of the secoiridoid content by using an internal standard during extraction. Firstly, two main Spanish varieties (Picual and Hojiblanca) were submitted to industrial filtration of VOOs. Afterwards, the moisture content was determined in unfiltered and filtered VOOs, and liquid-liquid extraction of phenolic compounds was performed using different internal standards. The resulting extracts were analyzed by HPLC-ESI-TOF/MS, in order to gain maximum information concerning the phenolic profiles of the samples under study. The reduction effect of filtration on the moisture content, phenolic alcohols, and flavones was confirmed at the industrial scale. Oleuropein was chosen as internal standard and, for the first time, the apparent increase of secoiridoids in filtered VOO was corrected, using a correction coefficient (Cc) calculated from the variation of internal standard area in filtered and unfiltered VOO during extraction. This approach gave the real concentration of secoiridoids in filtered VOO, and clarified the effect of the filtration step on the phenolic fraction. This finding is of great importance for future studies that seek to quantify phenolic compounds in VOOs.
Resumo:
The present paper describes a novel, simple and reliable differential pulse voltammetric method for determining amitriptyline (AMT) in pharmaceutical formulations. It has been described for many authors that this antidepressant is electrochemically inactive at carbon electrodes. However, the procedure proposed herein consisted in electrochemically oxidizing AMT at an unmodified carbon nanotube paste electrode in the presence of 0.1 mol L(-1) sulfuric acid used as electrolyte. At such concentration, the acid facilitated the AMT electroxidation through one-electron transfer at 1.33 V vs. Ag/AgCl, as observed by the augmentation of peak current. Concerning optimized conditions (modulation time 5 ms, scan rate 90 mV s(-1), and pulse amplitude 120 mV) a linear calibration curve was constructed in the range of 0.0-30.0 μmol L(-1), with a correlation coefficient of 0.9991 and a limit of detection of 1.61 μmol L(-1). The procedure was successfully validated for intra- and inter-day precision and accuracy. Moreover, its feasibility was assessed through analysis of commercial pharmaceutical formulations and it has been compared to the UV-vis spectrophotometric method used as standard analytical technique recommended by the Brazilian Pharmacopoeia.
Resumo:
Originally from Asia, Dovyalis hebecarpa is a dark purple/red exotic berry now also produced in Brazil. However, no reports were found in the literature about phenolic extraction or characterisation of this berry. In this study we evaluate the extraction optimisation of anthocyanins and total phenolics in D. hebecarpa berries aiming at the development of a simple and mild analytical technique. Multivariate analysis was used to optimise the extraction variables (ethanol:water:acetone solvent proportions, times, and acid concentrations) at different levels. Acetone/water (20/80 v/v) gave the highest anthocyanin extraction yield, but pure water and different proportions of acetone/water or acetone/ethanol/water (with >50% of water) were also effective. Neither acid concentration nor time had a significant effect on extraction efficiency allowing to fix the recommended parameters at the lowest values tested (0.35% formic acid v/v, and 17.6 min). Under optimised conditions, extraction efficiencies were increased by 31.5% and 11% for anthocyanin and total phenolics, respectively as compared to traditional methods that use more solvent and time. Thus, the optimised methodology increased yields being less hazardous and time consuming than traditional methods. Finally, freeze-dried D. hebecarpa showed high content of target phytochemicals (319 mg/100g and 1,421 mg/100g of total anthocyanin and total phenolic content, respectively).
Resumo:
Extraction processes are largely used in many chemical, biotechnological and pharmaceutical industries for recovery of bioactive compounds from medicinal plants. To replace the conventional extraction techniques, new techniques as high-pressure extraction processes that use environment friendly solvents have been developed. However, these techniques, sometimes, are associated with low extraction rate. The ultrasound can be effectively used to improve the extraction rate by the increasing the mass transfer and possible rupture of cell wall due the formation of microcavities leading to higher product yields with reduced processing time and solvent consumption. This review presents a brief survey about the mechanism and aspects that affecting the ultrasound assisted extraction focusing on the use of ultrasound irradiation for high-pressure extraction processes intensification.
Resumo:
A rapid, sensitive and specific method for quantifying propylthiouracil in human plasma using methylthiouracil as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethyl acetate). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS) in negative mode (ES-). Chromatography was performed using a Phenomenex Gemini C18 5μm analytical column (4.6mm×150mm i.d.) and a mobile phase consisting of methanol/water/acetonitrile (40/40/20, v/v/v)+0.1% of formic acid. For propylthiouracil and I.S., the optimized parameters of the declustering potential, collision energy and collision exit potential were -60 (V), -26 (eV) and -5 (V), respectively. The method had a chromatographic run time of 2.5min and a linear calibration curve over the range 20-5000ng/mL. The limit of quantification was 20ng/mL. The stability tests indicated no significant degradation. This HPLC-MS/MS procedure was used to assess the bioequivalence of two propylthiouracil 100mg tablet formulations in healthy volunteers of both sexes in fasted and fed state. The geometric mean and 90% confidence interval CI of Test/Reference percent ratios were, without and with food, respectively: 109.28% (103.63-115.25%) and 115.60% (109.03-122.58%) for Cmax, 103.31% (100.74-105.96%) and 103.40% (101.03-105.84) for AUClast. This method offers advantages over those previously reported, in terms of both a simple liquid-liquid extraction without clean-up procedures, as well as a faster run time (2.5min). The LOQ of 20ng/mL is well suited for pharmacokinetic studies. The assay performance results indicate that the method is precise and accurate enough for the routine determination of the propylthiouracil in human plasma. The test formulation with and without food was bioequivalent to reference formulation. Food administration increased the Tmax and decreased the bioavailability (Cmax and AUC).