997 resultados para environmental diagnosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Ciências do Ambiente, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p<0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). 14C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Toxocariasis is caused by infection of man by Toxocara canis and Toxocara cati larvae, the common roundworm of dogs and cats. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. Non specific reactions are observed mainly due to cross-reactivity with Ascaris sp antigens. This investigation aimed at developing and evaluating an indirect antibody competition ELISA (IACE) employing a specific rabbit IgG anti-Toxocara canis excretory-secretory antigens as the competition antibody, in order to improve indirect ELISA specificity performed for toxocariasis diagnosis. For that, the rabbit IgG was previously absorbed by Ascaris suum adult antigens. Sensitivity and specificity of IACE were first evaluated in 28 serum samples of mice experimentally infected with T. canis embryonated eggs. Adopting cut-off value established in this population before infection, sensitivity and specificity were 100% after 20 days post-inoculation. For human population IACE was evaluated using sera from 440 patients with clinical signs of toxocariasis and the cut-off value was established with 60 serum samples from apparently healthy individuals. Using as reference test the indirect ELISA performed by Adolfo Lutz Institute, sensitivity was 60.2%, specificity was 98% and concordance was 77.3%. Repeatability of IACE was evaluated by the inter-reactions variation coefficient (2.4%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three GST fusion recombinant antigen of Treponema pallidum, described as GST-rTp47, GST-rTp17 and GST-rTp15 were analyzed by Western blotting techniques. We have tested 53 serum samples: 25 from patients at different clinical stages of syphilis, all of them presenting anti-treponemal antibody, 25 from healthy blood donors and three from patients with sexually transmitted disease (STD) other than syphilis. Almost all samples from patients with syphilis presented a strong reactivity with GST-rTp17 antigen. Some samples were non-reactive or showed a weak reaction with GST-rTp47 and/or GST-rTp15, and apparently there was no correlation with the stage of disease. There was no seropositivity among blood donors. No sample reacted with purified GST. We concluded that due to their specificity these recombinant antigens can be used as GST fusion protein for development of syphilis diagnostic assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um dos principais objetivos da ciência é perceber a natureza, i.e., descobrir e explicar o funcionamento do mundo que nos rodeia. Para tal, os cientistas precisam de coligir dados e monitorar o meio ambiente. Em particular, considerando que cerca de 70% da Terra é coberta por água, a coleta de parâmetros de caracterização da água de grandes superfícies é uma prioridade. A monitorização das condições da água é feita principalmente através de bóias. No entanto, as bóias disponíveis no mercado não satisfazem as necessidades existentes. Esta é uma das principais razões que levaram o Laboratório de Sistemas Autónomos (LSA) do Instituto Superior de Engenharia do Porto a lançarem um projeto para o desenvolvimento de uma bóia reconfigurável e com dois modos de funcionamento: monitorização ambiental e baliza ativa de regata. O segundo modo é destinado a regatas de veleiros autónomos. O projeto começou há um ano com um projeto do European Project Project [1] (EPS), realizado por quatro estudantes internacionais, destinado à construção da estrutura da bóia e à selecção dos componentes mais adequados para o sistema de medição e controlo. A arquitetura que foi definida para este sistema é do tipo mestre-escravo e é composta por uma unidade de controlo mestre para a telemetria e configuração e uma unidade de controlo escrava para a medição e armazenamento de dados. O desenvolvimento do projeto continuou com dois estudantes belgas que trabalharam na comunicação e no armazenamento de dados. Este projeto, que prossegue com o desenvolvimento da medição e do armazenamento de dados do lado da unidade de controlo escrava, tem os seguintes objetivos: (i ) implementar o protocolo de comunicação na unidade de controlo escrava; (ii ) coligir e armazenar os dados dos sensores no cartão SD em tempo real; (iii ) fornecer dados em tempo útil; e (iv) recuperar dados do cartão SD em tempo diferido. As contribuições anteriores foram estudadas e foi feito um levantamento dos projetos congéneres existentes. O desenvolvimento do projeto atual começou com o protocolo de comunicação. Este protocolo, que foi projetado pelos alunos anteriores, foi um bom ponto de partida. No entanto, o protocolo foi atualizado e melhorado com novas funcionalidades. Esta última componente foi um trabalho conjunto com Laurens Allart, que esteve a trabalhar no subsistema de telemetria e de configuração durante este semestre. O protocolo foi implementado do lado da unidade de controlo escrava através de uma estrutura de múltiplas actividades paralelas (multithreaded). Esta estrutura recebe as mensagens da unidade mestre, executa as ações solicitadas e envia de volta o resultado. A bóia é um dispositivo reconfigurável multimodo que pode ser expandido com novos modos de operação no futuro. Infelizmente, sofre de algumas limitações: suporta uma carga máxima de 40 kg e tem uma área de implantação limitada pela distância máxima à estacão base.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the indirect immunofluorescence assay (IFA) with Western blot (Wb) as a confirmatory method to detect antibodies anti retrovirus (HIV-1 and HTLV-I/II). Positive and negative HIV-1 and HTLV-I/II serum samples from different risk populations were studied. Sensitivity, specificity, positive, negative predictive and kappa index values were assayed, to assess the IFA efficiency versus Wb. The following cell lines were used as a source of viral antigens: H9 ( HTLV-III b); MT-2 and MT-4 (persistently infected with HTLV-I) and MO-T (persistently infected with HTLV-II). Sensitivity and specificity rates for HIV-1 were 96.80% and 98.60% respectively, while predictive positive and negative values were 99.50% and 92.00% respectively. No differences were found in HIV IFA performance between the various populations studied. As for IFA HTLV system, the sensitivity and specificity values were 97.91% and 100% respectively with positive and negative predictive values of 100% and 97.92%. Moreover, the sensitivity of the IFA for HTLV-I/II proved to be higher when the samples were tested simultaneously against both antigens (HTLV-I-MT-2 and HTLV-II-MO-T). The overall IFA efficiency for HIV-1 and HTLV-I/II-MT-2 antibody detection probed to be very satisfactory with an excellent correlation with Wb (Kappa indexes 0.93 and 0.98 respectively). These results confirmed that the IFA is a sensitive and specific alternative method for the confirmatory diagnosis of HIV-1 and HTLV-I/II infection in populations at different levels of risk to acquire the infection and suggest that IFA could be included in the serologic diagnostic algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a procedure for the rapid diagnosis of plague that also allows the identification of prominent virulence markers of Y. pestis strains. This procedure is based upon the use of a single polymerase chain reaction with multiple pairs of primers directed at genes present in the three virulence plasmids as well as in the chromosomal pathogenicity island of the bacterium. The technique allowed the discrimination of strains which lacked one or more of the known pathogenic loci, using as template total DNA obtained from bacterial cultures and from simulated blood cultures containing diluted concentration of bacteria. It also proved effective in confirming the disease in a blood culture from a plague suspected patient. As the results are obtained in a few hours this technique will be useful in the methodology of the Plague Control Program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hantavirus pulmonary syndrome (HPS) has been recognized recently in Brazil, where 28 cases have been reported as of September 1999. We report here the clinical and laboratory findings of three cases whose diagnoses were confirmed serologically. All the patients were adults who presented a febrile illness with respiratory symptoms that progressed to respiratory failure that required artificial ventilation in two of them. Laboratory findings were most of the time consistent with those reported in the United States in patients infected with the Sin Nombre virus, and included elevated hematocrit and thrombocytopenia; presence of atypical lymphocytes was observed in one patient. The chest radiological findings observed in all the patients were bilateral, diffuse, reticulonodular infiltrates. Two patients died. Histopathological examination of the lungs of these patients revealed interstitial and alveolar edema, alveolar hemorrhage, and mild interstitial pneumonia characterized by infiltrate of immunoblasts and mononuclear cells. In the epidemiologic investigation of one of the cases, serologic (ELISA) tests were positive in 3 (25%) out of 12 individuals who shared the same environmental exposure. HPS should be included in the differential diagnosis of interstitial pneumonia progressing to acute respiratory failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study ELISA was standardized for the diagnosis of swine cysticercosis based on necropsy parameters and confirmed positive and negative control sera. Serum samples from pigs with other infections were also assayed to determine possible cross-reactions. Four antigens were assayed: from Taenia crassiceps vesicular fluid (VF-Tcra) and crude larvae extract (T-Tcra), and from Taenia solium extracts of scolex (S-Ts) and of larvae (T-Ts). A checkerboard evaluation of antigen, serum and conjugate dilutions, as well as the use of Tween-20 and skim cow milk in wash and blocking solution had a marked effect on improving ELISA performance. All the antigens showed a good performance, but VF-Tcra was the best, with 96.0% and 80.0% sensitivities for cut-offs respectively at 2sd and 3sd, and corresponding specificities of 97.5% and 100.0%. Cross-reactivity was observed only with hydatidosis and ascaridiosis. In view of the high performance observed, the ELISA test should be recommended for the diagnosis of cysticercosis in suspected swine in slaughterhouses and for the screening of cysticercosis in swine production. These results will support integrated measures of cysticercosis control throughout the chain of swine production, effectively contributing to public health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crescente expansão urbana e o incremento das exigências ambientais e financeiras promovem a implementação de abordagens sustentáveis para a gestão das infraestruturas sanitárias. Assim, o recurso a instrumentos de monitorização e à modelação matemática surge como o caminho para a racionalização do investimento e a otimização dos sistemas existentes. Neste contexto, a modelação dinâmica de sistemas de drenagem urbana assume relevância para o controlo e redução dos caudais em excesso e das descargas de poluentes nos meios recetores, resultantes de um incremento significativo de afluências pluviais indevidas, de problemas de sub-dimensionamento ou falta de operação e manutenção. O objetivo da presente dissertação consiste na modelação, calibração e diagnóstico do sistema intercetor de Lordelo utilizando o software Storm Water Management Model, através dos dados recolhidos a partir do projeto de Reabilitação dos intercetores de Lordelo, elaborado pela Noraqua. A modelação considera a avaliação das afluências de tempo seco e as afluências pluviais pelo software Sanitary Sewer Overflow Analysis and Planning Toolbox. Com efeito, a simulação dinâmica, permitiu um conhecimento mais detalhado do sistema, avaliando a capacidade hidráulica e localizando os pontos propícios a inundações. Assim, foi possível testar soluções de beneficiação do sistema, englobando a problemática das afluências pluviais indevidas calibradas. Apesar das dificuldades sentidas face à qualidade dos dados existentes, verificou-se que o SSOAP e o SWMM são ferramentas úteis na deteção, diagnóstico e redução dos caudais em excesso e que o procedimento utilizado pode ser aplicado a sistemas semelhantes, como forma de definir a melhor solução técnica e económica ao nível do planeamento, operação e reabilitação do sistema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening blood donations for anti-HCV antibodies and alanine aminotransferase (ALT) serum levels generally prevents the transmission of hepatitis C virus (HCV) by transfusion. The aim of the present study was to evaluate the efficiency of the enzyme immunoassay (EIA) screening policy in identifying potentially infectious blood donors capable to transmit hepatitis C through blood transfusion. We have used a reverse transcriptase (RT)-nested polymerase chain reaction (PCR) to investigate the presence of HCV-RNA in blood donors. The prevalence of HCV-RNA positive individuals was compared with the recombinant immunoblot assay (RIBA-2) results in order to assess the usefulness of both tests as confirmatory assays. Both tests results were also compared with the EIA-2 OD/C ratio (optical densities of the samples divided by the cut off value). ALT results were expressed as the ALT quotient (qALT), calculated dividing the ALT value of the samples by the maximum normal value (53UI/l) for the method. Donors (n=178) were divided into five groups according to their EIA anti-HCV status and qALT: group A (EIA > or = 3, ALT<1), group B (EIA > or = 3, ALT>1), group C (1<=EIA<3, ALT<1), group D (1<=EIA<3, ALT>1) and group E (EIA<=0.7). HCV sequences were detected by RT-nested PCR, using primers for the most conserved region of viral genome. RIBA-2 was applied to the same samples. In group A (n=6), all samples were positive by RT-nested PCR and RIBA-2. Among 124 samples in group B, 120 (96.8%) were RIBA-2 positive and 4 (3.2%) were RIBA-2 indeterminate but were seropositive for antigen c22.3. In group B, 109 (87.9%) of the RIBA-2 positive samples were also RT-nested PCR positive, as well as were all RIBA-2 indeterminate samples. In group C, all samples (n=9) were RT-nested PCR negative: 4 (44.4%) were also RIBA-2 negative, 4 (44.4%) were RIBA-2 positive and 1 (11.1%) was RIBA-2 indeterminate. HCV-RNA was detected by RT-nested PCR in 3 (37.5%) out of 8 samples in group D. Only one of them was also RIBA-2 positive, all the others were RIBA-2 indeterminate. All of the group E samples (controls) were RT- nested PCR and RIBA-2 negative. Our study suggests a strong relation between anti-HCV EIA-2 ratio > or = 3 and detectable HCV-RNA by RT-nested PCR. We have also noted that blood donors with RIBA-2 indeterminate presented a high degree of detectable HCV-RNA using RT-nested PCR (75%), especially when the c22.3 band was detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human cryptosporidiosis is an infection caused by Cryptosporidium spp, a coccidial protozoan of emergencial pathogenicity and responsible for severe and prostrating watery diarrhea, mainly in immunocompromised patients. Smears of stools submitted to concentration and staining by carbol fuchsin technique has been used in our laboratory as a diagnostic procedure for cryptosporidiosis. The long time observing the smears in the microscope due to the small size of the forms and the low contrast of the staining led us to introduce some modifications in the original protocol for the acid-fast staining. The smears were treated with the carbol fuchsin solution for 3 minutes as recommended by LENNETTE et al., 1985 and the solution of the ethyl alcohol 70%-chloride acid 0.5% was used instead of the ethyl alcohol-sulfuric acid 5% recommended by HENRIKSEN & POHLENZ, 1981. Smears were treated with the discoloration solution for 2 minutes. These modifications promoted a better washing out of the excess of carbol fuchsin therefore increasing the dye efficiency. In such conditions, the visualization of protozoan oocysts on the slides examined became easier. They were observed by the contrast of their intense pink-reddish pigmentation against the blue background. It's worthwhile to emphasize that these modifications offer advantages when time and accuracy are concerned.