933 resultados para corrosion protection
Resumo:
Increasingly growing share of distributed generation in the whole electrical power system’s generating system is currently a worldwide tendency, driven by several factors, encircling mainly difficulties in refinement of megalopolises’ distribution networks and its maintenance; widening environmental concerns adding to both energy efficiency approaches and installation of renewable sources based generation, inherently distributed; increased power quality and reliability needs; progress in IT field, making implementable harmonization of needs and interests of different-energy-type generators and consumers. At this stage, the volume, formed by system-interconnected distributed generation facilities, have reached the level of causing broad impact toward system operation under emergency and post-emergency conditions in several EU countries, thus previously implementable approach of their preliminary tripping in case of a fault, preventing generating equipment damage and disoperation of relay protection and automation, is not applicable any more. Adding to the preceding, withstand capability and transient electromechanical stability of generating technologies, interconnecting in proximity of load nodes, enhanced significantly since the moment Low Voltage Ride-Through regulations, followed by techniques, were introduced in Grid Codes. Both aspects leads to relay protection and auto-reclosing operation in presence of distributed generation generally connected after grid planning and construction phases. This paper proposes solutions to the emerging need to ensure correct operation of the equipment in question with least possible grid refinements, distinctively for every type of distributed generation technology achieved its technical maturity to date and network’s protection. New generating technologies are equivalented from the perspective of representation in calculation of initial steady-state short-circuit current used to dimension current-sensing relay protection, and widely adopted short-circuit calculation practices, as IEC 60909 and VDE 0102. The phenomenon of unintentional islanding, influencing auto-reclosing, is addressed, and protection schemes used to eliminate an sustained island are listed and characterized by reliability and implementation related factors, whereas also forming a crucial aspect of realization of the proposed protection operation relieving measures.
Resumo:
Korkean IP-luokituksen ohutlevykotelointi on haastava kokonaisuus. Koteloinnin tiivistys ruiskutettavalla polyureapinnoitteella edellyttää usean osa-alueen samanaikaista hallintaa. Kotelo on alusta alkaen suunniteltava pinnoitettavaksi, sillä pinnoitus asettaa lukuisia vaatimuksia ja rajoituksia esimerkiksi käytettäville muodoille, rakenteille ja liittämismenetelmille. Polyurea on elastomeeri, josta valmistettua pinnoitetta voidaan levittää erityisellä ruiskutuslaitteistolla. Polyureapinnoite sallii kotelon asentamisen vaikeisiin olosuhteisiin, sillä se kestää kemikaaleja, kulutusta ja iskuja sekä tarjoaa tiiveyden lisäksi korroosiosuojan koteloinnille. Pinnoitteen ominaisuuksia, kuten kovuutta, elastisuutta ja kemikaalien sekä UV-säteilyn kestoa voidaan räätälöidä käyttökohteen mukaan. Polyurepinnoitteeella pinnoitettavat pinnat on pyrittävä pitämään mahdollisimman yksinkertaisina, mikä tarkoittaa käytännössä kaikenlaisten kohoumien, ulkonevien osien, reikien ja muiden epäjatkuvuuskohtien välttämistä. Kaikki epäjatkuvuuskohdat vaativat erityishuomiota pinnoituksen aikana, sillä epäjatkuvuuskohtien onnistunut pinnoitus vaatii ruiskutusta useasta suunnasta, mikä lisää virhemahdollisuuksia ja siten vaarantaa koteloinnin tiiveyden. Liittämismenetelmät ovat yksinkertaisten muotojen ohella avainasemassa pinnoituksen onnistumisen kannalta. Menetelmistä tulee suosia sellaisia, joiden pinnoitettavaan pintaan aiheuttama epäjatkuvuuskohta on mahdollisimman vähäinen. Tällaisia menetelmiä ovat esimerkiksi vastuspistehitsaus ja puristeruuvi.
Resumo:
1894 (A28).
Resumo:
1891 (A25).
Resumo:
1871 (A5).
Resumo:
1910 (A44).
Resumo:
1886 (A20).
Resumo:
1883 (A17).
Resumo:
1890 (A24).
Resumo:
1887 (A21).
Resumo:
1903 (A37).