1000 resultados para condicionamento térmico
Resumo:
With the emergence of new technologies, has grown the need to use new materials, and this has intensified research on the collection and use of materials from renewable sources, is to reduce production costs and / or environmental impact. In this context, it was found that the sheath coconut straw, can be utilized as raw material for the production of a eco-composite that can be used as a thermal and acoustic insulator. After selected from the coconut sheaths were subjected to treatment with aqueous 2 % sodium hydroxide (NaOH). The composite study was produced with the sheath and coconut natural latex, with coconut sheath percentage in the proportions 15%, 25% and 35% of the total compound volume. Physical, thermal and acoustic properties of the composites were analyzed in order to obtain data on the use of viability as thermoacoustic insulation. The CP15 composites, CP25 and CP35 showed thermal conductivity 0.188 W/m.K, 0.155 W/m.K and 0.150 W/m.K, respectively. It can be applied as thermal insulation in hot systems to 200 ° C. The CP35 composite was more efficient as a thermal and acoustic insulation, providing 20% noise reduction, 31% and 34% for frequencies of 1 kHz, 2 kHz and 4 kHz, respectively. The analyzes were based on ABNT, ASTM, UL. Based on these results, it can be concluded that the eco-composite produced the hem of coconut can be used as thermal and acoustic insulation. Thus, it gives a more noble end to this material, which most often is burned or disposed of improperly in the environment.
Resumo:
Squamous cell carcinoma of oral tongue shows high rates of morbidity and mortality in the population, therefore, great efforts are being made to classify morphological changes and identify biomarkers that have prognostic value and that are able to group patients in individualized therapeutic options. From this perspective, there is the heat shock factor 1 (HSF1), which is a heat shock factor transcription protein (HSPs) that allows the cancer to deal with stressors associated with malignancy, acting differently in tumor progression. This research aimed to perform a clinico-pathological analysis of 70 cases of oral tongue squamous cell carcinoma (OTSCC) and immunohistochemical study of the expression of HSF1 protein in OTSCC, comparing it with 30 specimens of normal oral mucosa (NOM), and correlating this immunostaining with clinico-pathological aspects of OTSCC. To analyze the association between immunoexpression of HSF1 and clinicophatoloical aspects, the cases were categorized in minor and major overexpression, based in the median immunostaining score. Regarding the cases of OTSCC, 57.1% showed clinical stage III or IV, 82.9% were graded as high grade according to Bryne (1998) and 47.1% as high risk of malignancy according to Brandwein-Gensler et al., (2005). A disease free survival rate of 47.84% and overall survival rate of 68.20% was observed in the analyzed cases, and the high degree of malignancy according to Bryne’s system (1998) (p=0.05), tumor size T3 or T4 (p=0.04), local recurrence (p=0.02), and perineural invasion (p=0.02) determined negative impacts in survival time. We observed also a statistically significant result (p<0.01) when comparing the immunoreactivity of HSF1 between NOM and OTSCC. This significantly increased expression of HSF1 in cases of OTSCC suggests that this protein acts, indeed, in the pathogenesis of this disease. However, there were no statistically significant associations between this overexpression and the clinico-pathological parameters analyzed. This finding may reflect the influence of epigenetic events on HSF1 gene or a possible stability of this protein expression throughout disease progression.
Resumo:
Squamous cell carcinoma of oral tongue shows high rates of morbidity and mortality in the population, therefore, great efforts are being made to classify morphological changes and identify biomarkers that have prognostic value and that are able to group patients in individualized therapeutic options. From this perspective, there is the heat shock factor 1 (HSF1), which is a heat shock factor transcription protein (HSPs) that allows the cancer to deal with stressors associated with malignancy, acting differently in tumor progression. This research aimed to perform a clinico-pathological analysis of 70 cases of oral tongue squamous cell carcinoma (OTSCC) and immunohistochemical study of the expression of HSF1 protein in OTSCC, comparing it with 30 specimens of normal oral mucosa (NOM), and correlating this immunostaining with clinico-pathological aspects of OTSCC. To analyze the association between immunoexpression of HSF1 and clinicophatoloical aspects, the cases were categorized in minor and major overexpression, based in the median immunostaining score. Regarding the cases of OTSCC, 57.1% showed clinical stage III or IV, 82.9% were graded as high grade according to Bryne (1998) and 47.1% as high risk of malignancy according to Brandwein-Gensler et al., (2005). A disease free survival rate of 47.84% and overall survival rate of 68.20% was observed in the analyzed cases, and the high degree of malignancy according to Bryne’s system (1998) (p=0.05), tumor size T3 or T4 (p=0.04), local recurrence (p=0.02), and perineural invasion (p=0.02) determined negative impacts in survival time. We observed also a statistically significant result (p<0.01) when comparing the immunoreactivity of HSF1 between NOM and OTSCC. This significantly increased expression of HSF1 in cases of OTSCC suggests that this protein acts, indeed, in the pathogenesis of this disease. However, there were no statistically significant associations between this overexpression and the clinico-pathological parameters analyzed. This finding may reflect the influence of epigenetic events on HSF1 gene or a possible stability of this protein expression throughout disease progression.
Resumo:
Compete aos agentes que concebem os edifícios, bem como aos legisladores e aos promotores, dotá-los com o máximo possível de tecnologias passivas que permitam ao utilizador economizar, sem no entanto perder conforto nem salubridade. O presente estudo consiste num trabalho de revisão bibliográfica e de investigação experimental com vista à avaliação do comportamento dinâmico de paredes de alvenaria de tijolo térmico. Aferiu-se o desempenho térmico deste tipo de paredes e a viabilidade da sua utilização essencialmente numa perspetiva da redução dos consumos energéticos e de garantia do conforto térmico e salubridade nos edifícios. Os tijolos térmicos estão cada vez mais a ser introduzidos na construção devido ainda à simplicidade na construção e a possível eliminação/redução do material isolante. Neste trabalho construiu-se uma célula de teste com paredes constituídas por este tipo de tijolo, o Bloco ThermoPrélis, cedido pela empresa PRELIS Lda. Assim, mediu-se o desempenho térmico do mesmo em condições reais, em períodos nas estações de primavera e do verão. Os resultados experimentais mostram claramente as vantagens da construção com este tipo de tijolo, que apresenta um atraso térmico de 7 a 8 horas e um amortecimento da amplitude térmica no ambiente interior bastante significativo, tirando partido do mecanismo físico associado à inércia térmica. Em termos de custos, a construção com tijolo térmico apresenta vantagens, quando comparado com a construção típica em parede dupla com isolamento térmico na caixa-de-ar.
Resumo:
El Ecosistema de Afloramiento Peruano (EAP) es una de las zonas marinas con mayor productividad pesquera en el mundo y por su ubicación geográfica, es afectada por procesos físicos remotos, principalmente por la variabilidad climática interanual proveniente del océano Pacifico Ecuatorial, cuya señal dominante es El Niño y la Oscilación Sur (ENOS). Con el fin de evaluar los efectos de ENOS frente al Perú, se desarrolló el Índice Térmico Costero Peruano (ITCP) que representa el 87,7% de la variación total de las anomalías de la temperatura superficial del mar del EAP. Se analizó el periodo 1982-2014, detectándose 12 periodos con condiciones cálidas y 16 con condiciones frías. El ITCP tuvo una tendencia lineal, un componente de bajas frecuencias y un componente de ruido, con 1,5%, 94,5 % y 4 % de contribución a la varianza total, respectivamente. El ITCP presenta ventajas respecto a otros índices climáticos de la costa peruana, porque comprende el área representativa del Ecosistema de Afloramiento Peruano y porque captura la señal del afloramiento costero así como de los efectos térmicos de El Niño y La Niña.
Resumo:
Para avaliar os efeitos de diferentes tempos de pré-condicionamento isquêmico (IPC) em translocação bacteriana intestinal (BT). MÉTODOS: Trinta ratos Wistar pesando 280 ± 27g foram divididos em cinco grupos. No grupo IV (n = 6), a laparotomia foi realizada e a artéria mesentérica superior foi obstruído por um microclampe atraumática durante 30 minutos. Nos quatro grupos de pré-condicionamento (n = 6 cada) antes dos 30 minutos de isquemia-reperfusão (I / R), os ratos foram submetidos a IPC para duas, cinco, dez e 15 minutos, seguido pelo mesmo momento da reperfusão. A fim de avaliar se o tempo de pré-condicionamento influenciaram o surgimento de translocação bacteriana, as amostras de nódulos linfáticos mesentéricos, fígado e baço foram colhidas em condições estéreis, 24 horas após os procedimentos para a quantificação de unidades formadoras de colónias de bactérias por grama de tecido (CFU / g). O sangue foi recolhido para a medição de citoquinas. RESULTADOS: No grupo I / R, o total de CFU / g em gânglios linfáticos mesentéricos, baço, fígado, bem como o soro de TNF-a, IL-1A e IL-6 foram significativamente mais elevados do que nos outros grupos (p <0,05). Pré-condicionamento por 15 minutos significativamente atenuada BT e citocinas séricas quando comparado a outros períodos de pré-condicionamento (p <0,05). CONCLUSÃO: Nossos dados sugerem que o pré-condicionamento como um fator chave para reduzir a translocação bacteriana intestinal em I / R. Numa escala de dois a 15 minutos, o melhor tempo de pré-condicionamento isquémico pela atenuação da translocação bacteriana foi de 15 minutos
Resumo:
[ES] Se presenta una aplicación que utiliza información de varios sensores satelitales a diferentes escalas para hacer el seguimiento de la evolución espacio-temporal de 8 ejemplares juveniles de tortuga boba (Caretta caretta) que fueron equipados con trasmisores ARGOS en las Islas Canarias entre 1999 y 2000. Consiste en una base de datos multisensor y multiescala que se fusiona con los datos de posicionamiento y buceos para producir conjuntos multiparamétricos que pueden analizarse desde el punto de vista ecofisiológico. Del uso de la aplicación se infiere información interesante sobre el comportamiento migratorio de estos reptiles en la región macaronésica.
Resumo:
The present research concerns about outdoor s thermal comfort conditions in hot-humid climate cities, understanding that life quality is a result of the urban object s type built for the human being in an environment with specific climate and morphological characteristics. It is presented as object of study the correlation between the neighborhood Renascença II s microclimate in São Luis /MA-Brazil, hot-humid climate city, and its urban morphological changes. As well as the thermal comfort s satisfaction level of its outdoor users. The research has as general goal to diagnosis the way these transformations caused by the urbanization influence the Renascença II s microclimate, identifying critical spots of the studied area, in order to contribute with land use recommendations based on bioclimatic architecture concepts and supply bases to urban design decisions adequate to the São Luis climate. It is presented as theoretical bases the urban climate, its concepts and elements. After that, the thermal comfort conditioners and its prediction models of thermal comfort sensation in outdoor are presented. The predictive models are presented along with bioclimatic assessment methods. Finally the use of bioclimatic assessment as an effective tool to identify places that need changes or preservation in order to seek environment quality. The applied methodology was based on the studies of Katzschner (1997), complemented by Oliveira s (1988) and Bustos Romero s (2001) studies that suggest an analysis and evaluation of maps of topography, buildings floors, land use, green areas and land covering, in order to overlap their characteristics and identify climate variable s measurements points; then a quantitative analysis of the climate variables (air temperature and humidity, wind speed and direction) of the chosen points takes place. It was perceived that Renaissance II has no permanence areas as squares or parks, its outdoor has little vegetation and presets high land impermeability and built density levels. The majority of the people interviewed said that was comfortable in a range of air temperature between 27,28ºC and 30,71ºC. The elaboration of a neighborhood master plan is important, which defines strategies for improvement of the life quality of its inhabitants
Resumo:
No panorama energético atual, medidas de desenvolvimento sustentável têm uma preponderância cada vez mais significativa e, sendo os edifícios responsáveis por 40% da energia consumida na EU, enquadra-se o desafio de integrar medidas de eficiência energética nos novos edifícios desde a fase de conceção. Sendo que este setor se encontra em contínua expansão, a redução dos consumos passará largamente pela otimização do comportamento térmico dos edifícios e dos sistemas energéticos que os equipam. No presente trabalho estudou-se o papel da inércia térmica na redução das necessidades de energia para climatização de edifícios com o objetivo de identificar estratégias destinadas ao melhoramento do comportamento térmico e desempenho energético de edifícios construídos com recurso à técnica construtiva LSF, caracterizados por uma fraca inércia térmica quando comparados com edifícios em tudo semelhantes mas construídos recorrendo a tecnologias convencionais sem esquecer as questões relacionadas com a respetiva viabilidade económica. Com resultado geral destaca-se desde logo a importância do local onde é mais benéfico adicionar massa térmica (paredes exteriores, cobertura, paredes interiores), assim como a necessidade de utilização de um material com elevada densidade energética e baixo custo. A análise comparativa dos diferentes modelos de edifício simulados com recurso ao software DesignBuilder/EnergyPlus, foi realizada recorrendo a uma metodologia em que cada modelo construtivo é avaliado considerando quatro níveis de isolamento térmico e duas condições de cargas térmicas internas. A análise energética e económica foi realizada tendo como referência um período de 20 anos. O custo das soluções construtivas foi maioritariamente obtido através da ferramenta computacional Gerador de Preços, da Cype, SA©, tendo-se considerado um consumo energético anual constante e igual às necessidades de climatização anuais, assim como taxas de atualização de capital e de inflação do custo da energia constantes. De uma forma geral conclui-se que edifícios do tipo LSF melhorados através da adição criteriosa de massa térmica em determinados elementos construtivos, apresentam necessidades de climatização anuais na maioria dos casos estudados, inferiores àquelas verificadas em edifícios convencionais com inércia térmica média/forte. Conclui-se, também, que o método construtivo LSF se apresenta mais eficaz em termos energéticos e económicos quando comparado com soluções semelhantes construídas com recurso a um método convencional. Na secção seguinte são identificadas as principais conclusões deste trabalho.
Resumo:
Natural ventilation is an efficient bioclimatic strategy, one that provides thermal comfort, healthful and cooling to the edification. However, the disregard for quality environment, the uncertainties involved in the phenomenon and the popularization of artificial climate systems are held as an excuse for those who neglect the benefits of passive cooling. The unfamiliarity with the concept may be lessened if ventilation is observed in every step of the project, especially in the initial phase in which decisions bear a great impact in the construction process. The tools available in order to quantify the impact of projected decisions consist basically of the renovation rate calculations or computer simulations of fluids, commonly dubbed CFD, which stands for Computational Fluid Dynamics , both somewhat apart from the project s execution and unable to adapt for use in parametric studies. Thus, we chose to verify, through computer simulation, the representativeness of the results with a method of simplified air reconditioning rate calculation, as well as making it more compatible with the questions relevant to the first phases of the project s process. The case object consists of a model resulting from the recommendations of the Código de Obras de Natal/ RN, customized according to the NBR 15220. The study has shown the complexity in aggregating a CFD tool to the process and the need for a method capable of generating data at the compatible rate to the flow of ideas and are discarded during the project s development. At the end of our study, we discuss the necessary concessions for the realization of simulations, the applicability and the limitations of both the tools used and the method adopted, as well as the representativeness of the results obtained
Resumo:
This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity
Resumo:
The building envelope is the principal mean of interaction between indoors and environment, with direct influence on thermal and energy performance of the building. By intervening in the envelope, with the proposal of specific architectural elements, it is possible to promote the use of passive strategies of conditioning, such as natural ventilation. The cross ventilation is recommended by the NBR 15220-3 as the bioclimatic main strategy for the hot and humid climate of Natal/RN, offering among other benefits, the thermal comfort of occupants. The analysis tools of natural ventilation, on the other hand, cover a variety of techniques, from the simplified calculation methods to computer fluid dynamics, whose limitations are discussed in several papers, but without detailing the problems encountered. In this sense, the present study aims to evaluate the potential of wind catchers, envelope elements used to increase natural ventilation in the building, through CFD simplified simulation. Moreover, it seeks to quantify the limitations encountered during the analysis. For this, the procedure adopted to evaluate the elements implementation and efficiency was the CFD simulation, abbreviation for Computer Fluid Dynamics, with the software DesignBuilder CFD. It was defined a base case, where wind catchers were added with various settings, to compare them with each other and appreciate the differences in flows and air speeds encountered. Initially there has been done sensitivity tests for familiarization with the software and observe simulation patterns, mapping the settings used and simulation time for each case simulated. The results show the limitations encountered during the simulation process, as well as an overview of the efficiency and potential of wind catchers, with the increase of ventilation with the use of catchers, differences in air flow patterns and significant increase in air speeds indoors, besides changes found due to different element geometries. It is considered that the software used can help designers during preliminary analysis in the early stages of design