1000 resultados para comparação de métodos
Resumo:
Two kinds of roasting cocoa system: conventional batch method in electrical oven, and by microwaves, in a continuous microwave rotary applicator (2450MHz), were compared with respect to viscosity. Cocoa was roasted in whole beans and in nibs. The variable used in the microwave treatment was the power density applied to the whole beans (254,45 to 290,80 Wh/kg) and to the nibs (227,27 to 262,23 Wh/kg), with a constant holding time of 10 minutes. The variable used in the conventional roasting process was the roasting time of the beans (40 to 44 min) and the nibs (34 to 38 min), with constant temperature in the jacket of electric oven (150°C). Viscosity was measured in a Brookfield rheometer (mod RV-DVIII) at 40°C. In general, the plastic viscosity of the microwaved samples was lower than that of the conventional roasted samples. Also the nibs showed lower viscosities than the whole beans when roasted in the electric oven. The viscosity of the samples roasted in the microwave oven was lower in the whole beans than in the nibs. The product was sensorially evaluated by three experts in cocoa flavour, and it was shown that the flavour of the microwave roasted products was similar to that of the conventionally roasted products, with the advantage of a reduction in process time.
Resumo:
Twenty-two Triceps brachii muscle obtained from 11 cows aged 3 and 4 years , killed in an experimental slaughter plant, were submitted to mechanical tenderization, injection with acetic acid 0,1M and lactic acid 0,2M, ageing for 9 and 14 days and electrical stimulation (250v - 60Hz - 90s), some of them were reserved as a control group, without treatment. The 14 days ageing time presented 21% of increase in subjective tenderness and 12% of reduction in shear force, these values were similar to the electrical stimulated meat. However the injection with acids and the ageing time 9 days did not present significant effect in the texture. Although the shear force values of mechanical tenderized meat was the shortest among all treatments, suspect of superestimation because of the fractures plan created by this process. Another analyses were carried out: pH reduction curve, R value; colour analysis; weight losses by cooking and by treatment; and microbiological analysis.
Resumo:
The aim of this research was to optimize osmotic dehydration of pineapple, according to two criteria: maximize water loss and minimize solid gain. The process was made as an application to Combined Methods Technology, in which three preservation factors were combined: water activity, pH and chemical preservatives, all being applied at low levels, in order to get a product resembling non-processed fruit. The experiment was divided into three treatments, being: non-coated pineapple pieces (A), pieces coated with alginate (B) and coated with low-methoxyl pectin (C). Process involved the following main steps: enzymatic inactivation of fruit pieces; in treatments B and C, incorporation of their respective coatings; and osmotic dehydration, in sucrose syrup containing potassium sorbate and citric acid. Optimum conditions, determined from Response Surface Methodology, were the following: dehydration of fruit pieces coated by alginate, at 42-47° C, in sucrose syrup at 66-69° Brix, for 220 to 270 minutes. Results indicated that both coatings significantly affected the mass transfers of the process, reducing solid incorporation and increasing water loss; therefore, increasing weight loss and performance ratio (water loss: solid incorporation) took place. Water activity was not significantly affected by the coatings. The product obtained under optimum conditions was submitted to sensorial evaluation, and presented a good general acceptance. Moulds and yeasts countings indicated good microbiological stability of the product for at least 60 days at 30ºC.
Resumo:
Evolving interfaces were initially focused on solutions to scientific problems in Fluid Dynamics. With the advent of the more robust modeling provided by Level Set method, their original boundaries of applicability were extended. Specifically to the Geometric Modeling area, works published until then, relating Level Set to tridimensional surface reconstruction, centered themselves on reconstruction from a data cloud dispersed in space; the approach based on parallel planar slices transversal to the object to be reconstructed is still incipient. Based on this fact, the present work proposes to analyse the feasibility of Level Set to tridimensional reconstruction, offering a methodology that simultaneously integrates the proved efficient ideas already published about such approximation and the proposals to process the inherent limitations of the method not satisfactorily treated yet, in particular the excessive smoothing of fine characteristics of contours evolving under Level Set. In relation to this, the application of the variant Particle Level Set is suggested as a solution, for its intrinsic proved capability to preserve mass of dynamic fronts. At the end, synthetic and real data sets are used to evaluate the presented tridimensional surface reconstruction methodology qualitatively.
Resumo:
PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1% and 2%, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1% and 2%). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1% with 2% ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2% ibopamine (area under the ROC curve: 0.864, Se: 84.6%; Sp:73.3%). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2% ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1% ibopamine may be used to treat ocular hypotony.
Resumo:
OBJECTIVE: To evaluate the learning effect, short-term fluctuation and long-term fluctuation in healthy subjects undergoing frequency doubling perimetry (FDP). METHODS: Twenty healthy young subjects underwent FDT (program N30, full threshold) in one eye (right). Each subject was tested once in the first three sessions and three times in the fourth session. Both short- and long-term fluctuations were studied as the average fluctuation of all the tested points or as a point-to-point fluctuation. To study the learning effect, the MDs values of the first session were compared to the second, third and fourth sessions. RESULTS: In the short-term analysis (3 examination done in the last session), the total mean sensitivity was 31.91 ± 1.20 dB and the mean MD and PSD were 0.84 ± 1.85 and 3.73 ± 1.55 dB, respectively. The average short-term fluctuation was 1.72 ± 0.38 dB. When the four examination, performed at different visits, were compared, the average mean sensitivity of all sessions and the average long-term fluctuation were 31.75 ± 1.11 and 2.16 ± 0.26 dB, respectively. The MD averages of the first, second, third and fourth tests were 0.11 ± 2.14 dB, 0.47 ± 1.64 dB, 1.16 ± 1.62 dB and 0.98 ± 1.92 dB respectively. The MD difference between the first and the third and between the first and the fourth examinations were statistically significant (p<0.05). CONCLUSION: The threshold sensitivity detected by FDP is influenced by both short- and long-term fluctuations. We observed a mild learning effect that shoud be taken into account whenever a patient undergoes this test for the first time.
Resumo:
OBJECTIVE: To characterize the behavior of premature newborns in the first year of chronological age. METHODS: This is a cross-sectional descriptive study, bound to a longitudinal study titled: Comparison of visual behavior on the first quarter of year of life of premature nursling born at two maternities of Recife/PE. The sample was composed by 52 premature newborns selected from June, 2007 to June, 2008 from the Maternity of the Federal University of Pernambuco (UFPE). Biological, socioeconomic and demographic data was collected through medical records and interviews with progeny. Newborns were evaluated by the Assessment Guide of Visual Ability in Infants. RESULTS: Most of the newborns were male at a gestational period between 33 weeks and 36 weeks and 6 days, showed a good visual behavior development for the age researched, and most of the families showed good socioeconomical and demographic profile. Besides, it was possible to detect ocular signs in 19% of sample, that were referred to an Ophthalmology Service. CONCLUSION: This study results point out the method like an important key in the early detection and visual screening for premature nursling since the first month of life and it led us to believe that clinical view for occupational therapy intervention must be focused not only on biological risks but also at the influence environment in newborn performance.
Resumo:
PURPOSE: To compare clinical trials published in Brazilian journals of ophthalmology and in foreign journals of ophthalmology with respect to the number of citations and the quality of reporting [by applying the Consolidated Standards for Reporting Trials (CONSORT) statement writing standards]. METHODS: The sample of this systematic review comprised the two Brazilian journals of ophthalmology indexed at Science Citation Index Expanded and six of the foreign journals of ophthalmology with highest Impact Factor® according ISI. All clinical trials (CTs) published from January 2009 to December 2010 at the Brazilians journals and a 1:1 randomized sample of the foreign journals were included. The primary outcome was the number of citations through the end of 2011. Subgroup analysis included language. The secondary outcome included likelihood of citation (cited at least once versus no citation), and presence or absence of CONSORT statement indicators. RESULTS: The citation counts were statistically significantly higher (P<0.001) in the Foreign Group (10.50) compared with the Brazilian Group (0.45). The likelihood citation was statistically significantly higher (P<0.001) in the Foreign Group (20/20 - 100%) compared with the Brazilian Group (8/20 - 40%). The subgroup analysis of the language influence in Brazilian articles showed that the citation counts were statistically significantly higher in the papers published in English (P<0.04). Of 37 possible CONSORT items, the mean for the Foreign Group was 20.55 and for the Brazilian Group was 13.65 (P<0.003). CONCLUSION: The number of citations and the quality of reporting of clinical trials in Brazilian journals of ophthalmology still are low when compared with the foreign journals of ophthalmology with highest Impact Factor®.
Resumo:
PURPOSE: To determine the association between language and number of citations of ophthalmology articles published in Brazilian journals. METHODS: This study was a systematic review. Original articles were identified by review of documents published at the two Brazilian ophthalmology journals indexed at Science Citation Index Expanded - SCIE [Arquivos Brasileiros de Oftalmologia (ABO) and Revista Brasileira de Oftalmologia (RBO)]. All document types (articles and reviews) listed at SCIE in English (English Group) or in Portuguese (Portuguese Group) from January 1, 2008 to December 31, 2009 were included, except: editorial materials; corrections; letters; and biographical items. The primary outcome was the number of citations through the end of second year after publication date. Subgroup analysis included likelihood of citation (cited at least once versus no citation), journal, and year of publication. RESULTS: The search at the web of science revealed 382 articles [107 (28%) in the English Group and 275 (72%) in the Portuguese Group]. Of those, 297 (77.7%) were published at the ABO and 85 (23.3%) at the RBO. The citation counts were statistically significantly higher (P<0.001) in the English Group (1.51 - SD 1.98 - range 0 to 11) compared with the Portuguese Group (0.57 - SD 1.06 - range 0 to 7). The likelihood citation was statistically significant higher (P<0.001) in the English Group (70/107 - 65.4%) compared with the Portuguese Group (89/275 - 32.7%). There were more articles published in English at the ABO (98/297 - 32.9%) than at the RBO (9/85 - 10.6%) [P<0.001]. There were no significant difference (P=0.967) at the proportion of articles published in English at the years 2008 (48/172 - 27.9%) and 2009 (59/210 - 28.1%). CONCLUSION: The number of citations of articles published in Portuguese at Brazilian ophthalmology journals is lower than the published in English. The results of this study suggest that the editorial boards should strongly encourage the authors to adopt English as the main language in their future articles.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física