970 resultados para chirped pulse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of the duration of X-ray lasing pumped with picosecond pulses from the VULCAN optical laser are obtained using a streak camera with 700 fs temporal resolution. Combined with a temporal smearing due to the spectrometer employed, we have measured X-ray laser pulse durations for Ni-like silver at 13.9 nm with a total time resolution of 1.1 ps. For Ni-like silver, the X-ray laser output has a steep rise followed by an approximately exponential temporal decay with measured full-width at half-maximum (FWHM) of 3.7 (+/-0.5) ps. For Ne-like nickel lasing at 23.1 nm, the measured duration of lasing is approximate to10.7 (+/-1) ps (FWHM). An estimate of the duration of the X-ray laser gain has been obtained by temporally resolving spectrally integrated continuum and resonance line emission. For Ni-like silver, this time of emission is approximate to22 (+/-2) ps (FWHM), while for Ne-like nickel we measure approximate to35 (+/-2) ps (FWHM). Assuming that these times of emission correspond to the gain duration, we show that a simple model consistently relates the gain durations to the measured durations of X-ray lasing. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper summarises die main results obtained during the two experimental campaigns on TCE X-ray lasers that we have carried out since the last Kyoto X-ray laser Conference in 1998. A two-color (2 omega /1 omega) pumping configuration was tested and led to the observation of a strong lasing line at 16 nm, identified to a 4f-4d transition in Ni-like Ag. A strong x 300-400 enhancement of the 13.9 nm Ni-like 4d-4p lasing emission was obtained when a traveling wave short pulse pumping was applied. Finally the temporal history of the 13.9 nm laser pulse was measured with a high-resolution Streak camera, A very short 2 ps X-ray laser pulse was directly demonstrated for the first time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Double laser pulses of duration similar to 75 ps and short laser pulses similar to 1 ps superimposed on longer duration background pulses have been shown to efficiently pump lasing in Ne-like and Ni-like ions. For the 75 ps pumping, X-ray laser output without travelling wave pumping is shown to be well-described by a model of ASE output. With I ps pumping, the X-ray laser output with different velocity travelling wave pumping is well-fitted with an extension to the ASE model allowing for travelling wave excitation of the gain along the plasma line. The model is used to investigate the production of short (<1 ps) x-ray laser pulses and the effects of non-ideal travelling wave velocities on the X-ray laser output. Resonance line spectra of emission perpendicular to the plasma line are measured and simulated. It is shown that an accurate opacity model for the more intense Ne-like ions is needed to correctly simulate the spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electrostatic trapping scheme for use in the study of light-induced dissociation of molecular ions is outlined. We present a detailed description of the electrostatic reflection storage device and specifically demonstrate its use in the preparation of a vibrationally cold ensemble of deuterium hydride (HD+) ions. By interacting an intense femtosecond laser with this target and detecting neutral fragmentation products, we are able to elucidate previously inaccessible dissociation dynamics for fundamental diatomics in intense laser fields. In this context, we present new results of intense field dissociation of HD+ which are interpreted in terms of recent theoretical calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A scheme to obtain brilliant x-ray sources by coherent reflection of a counter-propagating pulse from laser-driven dense electron sheets is theoretically and numerically investigated in a self-consistent manner. A radiation pressure acceleration model for the dynamics of the electron sheets blown out from laser-irradiated ultrathin foils is developed and verified by PIC simulations. The first multidimensional and integral demonstration of the scheme by 2D PIC simulations is presented. It is found that the reflected pulse undergoes Doppler-upshift by a factor 4?z2, where ?z = (1- vz2/c2)-1/2 is the effective Lorentz factor of the electron sheet al ong its normal direction. Meanwhile the pulse electric field is intensified by a factor depending on the electron density of the sheet in its moving frame ne/?, where ? is the full Lorentz factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel scheme for enhancing electron localization in intense-field dissociation is outlined. Through manipulation of a bound vibrational wavepacket in the exemplar deuterium molecular ion, simulations demonstrate that the application of multiple phase-locked, few-cycle IR pulses can provide a powerful scheme for directing the molecular dissociation pathway. By tuning the time delay and carrier–envelope–phase for a sequence of pulse interactions, the probability of the electron being localized to a chosen nucleus can be enhanced to above 80%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple theoretical model is proposed for the interaction between two counter-propagating laser pulses (a pump and a seed pulse) in unmagnetized plasma. Pulse compression and amplification are observed via numerical simulation. A one dimensional fluid model for stimulated Raman backscattering is proposed to investigate the pulse compression and pulse amplification mechanisms. To accomplish this, energy is transferred from the long pump pulse to a seed pulse, with a Langmuir plasma wave mediating the transfer. The study focuses on the intensity profile of the pump laser pulse. A Gaussian and a ring intensity profile are, separately, considered for the pump laser pulse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Attenuation processes controlling virus fate and transport in the vadose zone of karstified systems can strongly influence groundwater quality. This research compares the breakthrough of two bacteriophage tracers (H40/1 and T7), with contrasting properties, at subsurface monitoring points following application onto an overlying composite sequence of thin organic soil and weathered limestone (epikarst). Short pulse multi-tracer test results revealed that T7 (Source concentration, Co=1.8x106pfu/mL) and H40/1(Co=5.9x106pfu/mL) could reach sampling points 10m below ground less than 30 minutes after tracer application. Contrasting deposition rates, determined from simulated tracer responses, reflected the potential of the ground to differentially attenuate viruses. Prolonged application of both T7 (Co=2.3x104pfu/mL) and H40/1 (Co=1.3x105pfu/mL) over a five hour period during a subsequent test, in which ionic strength levels observed at monitoring points rose consistently, corresponded to a rapid rise in T7 levels, followed by a gradual decline before the end of tracer injection; this reflected reaction-limited deposition in the system. T7’s response contrasted with that of H40/1, whose concentration remained constant over a three hour period before declining dramatically prior to the end of tracer injection. Subsequent application of lower ionic strength tracer-free flush water generated a rapid rise in H40/1 levels and a more gradual release of T7. Results highlight the benefits of employing prolonged injection multi-tracer tests for identifying processes not apparent from conventional short pulse tests. Study findings demonstrate that despite rapid transport rates, the epikarst is capable of physicochemical filtration of viruses and their remobilization, depending on virus type and hydrochemical conditions.