840 resultados para atrophic mandible


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this prospective study was to verify the changes in the preoperative and postoperative complete blood counts of patients with surgically treated facial fractures. Fifty consecutive patients with a mean age of 34 years who presented facial fractures and underwent surgical treatment were included. A complete blood count was performed, comprising the red and white blood cell count (cells/mu L), hemoglobin (g/dL), and hematocrit (%) levels. These data were obtained preoperatively and postoperatively during a 6-week period. Statistical analyses were performed using the Kruskal-Wallis and Mann-Whitney tests to identify the possible differences among the groups and among the periods of observation using the Friedman and Wilcoxon matched-pairs signed-ranks tests. The most common location of the fractures was the mandible (42.3%), followed by the zygomatic-orbital (36.5%) and associated locations (21.2%). Leukocytosis was associated with neutrophilia in the immediate postoperative period in all of the groups. There were no values below the reference limits of the values of hemoglobin, hematocrit, and erythrocytes, and no values above the reference limits for the remaining white blood cells, although significant differences among periods were observed in most cells, depending on the type of fracture. The primary findings were leukocytosis associated with neutrophilia, verified in the immediate postoperative period in all of the groups, and the influence of the type of fracture on the significant alterations observed among studied periods on the values of hemoglobin, hematocrit, erythrocytes, leukocytes, neutrophils, and lymphocytes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To investigate the facial symmetry of high and low dose methotrexate (MTX) treated rats submitted to experimentally displaced mandibular condyle fracture through the recording of cephalometric measurements. METHODS: One hundred male Wistar rats underwent surgery using an experimental model of right condylar fracture. Animals were divided into four groups: A - saline solution (1mL/week); B - dexamethasone (DEX) (0,15mg/Kg); C - MTX low dose (3 mg/Kg/week); D - MTX high dose (30 mg/Kg). Animals were sacrificed at 1, 7, 15, 30 and 90 days postoperatively (n=5). Body weight was recorded. Specimens were submitted to axial radiographic incidence, and cephalometric mensurations were made using a computer system. Linear measurements of skull and mandible, as well as angular measurements of mandibular deviation were taken. Data were subjected to statistical analyses among the groups, periods of sacrifice and between the sides in each group (alpha=0.05). RESULTS: Animals regained body weight over time, except in group D. There was reduction in the mandibular length and also changes in the maxilla as well as progressive deviation in the mandible in relation to the skull basis in group D. CONCLUSION: Treatment with high dose methotrexate had deleterious effect on facial symmetry of rats submitted to experimentally displaced condylar process fracture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study analyzed the effects of unilateral detachment of the temporal muscle and coronoidotomy on facial growth in young rats. Thirty one-month-old Wistar rats were distributed into three groups: detachment, coronoidotomy and sham-operated. Under general anesthesia, unilateral detachment of the temporal muscle was performed for the detachment group, unilateral coronoidotomy was performed for the coronoidotomy group, and only surgical access was performed for the sham-operated group. The animals were sacrificed at three months of age. Their soft tissues were removed, and the mandible was disarticulated. Radiographic projections-axial views of the skulls and lateral views of hemimandibles-were taken. Cephalometric evaluations were performed, and the values obtained were submitted to statistical analyses. There was a significant homolateral difference in the length of the premaxilla, height of the mandibular ramus and body, and the length of the mandible in all three groups. However, comparisons among the groups revealed no significant differences between the detachment and coronoidotomy groups for most measurements. It was concluded that both experimental detachment of the temporal muscle and coronoidotomy during the growth period in rats induced asymmetry of the mandible and affected the premaxilla.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The immatures of males of two species of Camponotus ants (Hymenoptera: Formicidae) are described and compared by light and electron microscopy. The numbers of larval instars were determined: Camponotus rufipes Fabricius (Hymenoptera: Formicidae) have four instars; and Camponotus vittatus Forel have three. Male larvae of the two species are similar to previously described Camponotus larvae, sharing the following traits: basic shape of body and mandible, presence of 'chiloscleres', 'praesaepium' (some specimens), labial pseudopalps, and ten pairs of spiracles. However, larvae of the two species can be separated by bodily dimensions and based on their hair number and types. Worker larvae of C. vittatus previously described are extensively similar to male larvae, with only a few inconspicuous differences that may result from intraspecific variation or sexual differences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the presence of both adjacent teeth on the level of alveolar bony crest at sites where implants were installed into the socket immediately after tooth extraction. Material and methods: Six Labrador dogs were used. Extractions of all teeth from the second premolar to the first molar were performed in the right side of the mandible, after full-thickness flap elevation. In the left side of the mandible, an endodontic treatment of the mesial root of the third and fourth premolars was performed. Full-thickness flaps were elevated, the teeth hemisected, and the distal roots removed. Immediately after, implants were bilaterally installed with the margin flush to the buccal bony crest. The implants were placed in the center of the alveolus at the third premolars and toward the lingual bony plate of the alveolus at the fourth premolars. After 3 months of healing, the animals were euthanized. Results: All implants were integrated in mature bone. More bone resorption was observed at the test compared to the control sites. At the buccal aspect, a resorption of 2.8 +/- 0.5 and 1.6 +/- 0.4 mm at the third premolars and of 2.4 +/- 0.6 and 0.8 +/- 0.7 mm at the fourth premolars were found, at the test and control sites, respectively. At the lingual aspect, the bony crest was apically located in relation to the implant shoulder 1.5 +/- 0.3 and 0.5 +/- 0.5 mm at the third premolars and 1.6 +/- 0.6 and 0.3 +/- 1.1 mm at the fourth premolars, at the test and control sites, respectively. A lower buccal bone resorption was found at the control implants placed lingually. Conclusion: Multiple extractions of teeth adjacent to a socket into which implants were installed immediately after, tooth extraction induced more alveolar bone recession compared to sites where the adjacent teeth were preserved. Moreover, an implant placed more lingually yielded less recession of the buccal aspect of the implant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to test the reproducibility, sensitivity, and specificity of cone-beam computed tomography (CBCT) in detecting incipient furcation involvement. Fifteen macerated pig mandibles, with intact second molar teeth and preserved adjacent cortical areas, were used. Simulated lesions were created in the furcation region of these teeth by applying 70% perchloric acid in up to four possible buccal/lingual sites in the right/left sides of each mandible. The mandibles were then submitted to a CBCT scan. Two blinded and calibrated experienced oral and maxillofacial radiologists interpreted the exams. Furcation involvement was also assessed in the regions without simulated lesions. CBCT showed high levels of accuracy, ranging from 78% to 88%. The variations in Kappa values for intra- and inter-observer agreement (0.41-0.59) were considered moderate. CBCT can be considered a reliable and accurate method for detecting incipient furcation involvement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Lucia jig is a technique that promotes neuromuscular reprogramming of the masticatory system and allows the stabilization of the mandible without the interference of dental contacts, maintaining the mandible position in harmonic condition with the musculature in normal subjects or in patients with temporomandibular dysfunction (TMD). This study aimed to electromyographically analyze the activity (RMS) of the masseter and temporal muscles in normal subjects (control group) during the use of an anterior programming device, the Lucia jig, in place for 0, 5, 10, 20 and 30 minutes to demonstrate its effect on the stomatognathic system. Forty-two healthy dentate individuals (aged 21 to 40 years) with normal occlusion and without parafunctional habits or ternporomandibular dysfunction (RDC/TMD) were evaluated on the basis of the electromyographic activity of the masseter and temporal muscles before placement of a neuromuscular re-programming device, the Lucia jig, on the upper central incisors. There were no statistically significant differences (p < 0.05) in the electromyographic activity of the masticatory muscles in the different time periods. The Lucia jig changed the electromyographic activity by promoting a neuromuscular reprogramming. In most of the time periods, it decreased the activation of the masticatory muscles, showing that this device has wide applicability in dentistry. The use of a Lucia jig over 0, 5, 10, 15, 20 and 30 minutes did not promote any statistically significant increase in muscle activity despite differences in the data, thus showing that this intra-oral device can be used in dentistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating the need of maxillomandibular block in the postoperative period. Objectives: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. Material and methods: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group). In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group). In group III, fixation was performed with two-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group). All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. Results: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. Conclusion: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The objective of this research was to study the influence of the use of helmet in facial trauma victims of motorcycle accidents with moderate traumatic brain injury. Methods: We retrospectively reviewed the incidence of facial injuries in helmeted and nonhelmeted victims with moderate traumatic brain injury at a referral trauma hospital. Results: The sample consisted of 272 patients predominantly men (94.5%) and between 21 and 40 years old (62.9%). The majority of patients were using helmet (80.1%). The occurrence of facial fractures was most frequent for zygomatic bone (51.8%), followed by mandible (18.8%) and nasal bones (9.2%). Conclusions: Individuals in the most productive age group are most affected, which causes a great loss to financial and labor systems. It is important to take measures to alert the public regarding the severity of injuries likely to occur in motorcycle-related accidents and ways to prevent them.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bars and steel wires are the most commonly used methods to achieve maxillomandibular fixation, although there are numerous alternatives described for this same purpose. In cases of edentulous candidates for the conservative treatment of facial fractures, none of the conventional methods can be instituted for maxillomandibular fixation. Fixation in such cases is achieved with the aid of the total dentures of the patient or the confection of splints, but these methods lead to eating and oral hygiene problems. This article reports the case of an edentulous patient with a comminuted mandible fracture treated with a rarely described technique in which intermaxillary fixation was achieved with titanium miniplates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate 16 patients of both sexes with lower overdenture and upper complete dentures, by analysing the resonance frequency of the initial and late stability of implants used to retain the overdenture under immediate loading. Background: Oral rehabilitation treatment with complete dentures using implants has been increasingly more common among the specialists in the oral rehabilitation area. This is an alternative for obtaining retention and stability in treatments involving conventional complete dentures, where two implants are enough to retain the overdenture satisfactorily. Materials and methods: The Osstell (TM) Mentor device was used for the analysis in the initial period (primary stability), 3 and 15 months after the installation of the lower overdenture (secondary stability). The statistical analysis was performed with the repeated measures model (p < 0.01). Results: The implant stability quotients were observed to increase after 15 months of the rehabilitating treatment. Conclusion: The use of overdentures over two lower implants should become the treatment of choice for individuals who have a fully edentulous mandible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent studies in animals have shown pronounced resorption of the buccal bone plate after immediate implantation. The use of flapless surgical procedures prior to the installation of immediate implants, as well as the use of synthetic bone graft in the gaps represent viable alternatives to minimize buccal bone resorption and to favor osseointegration. The aim of this study was to evaluate the healing of the buccal bone plate following immediate implantation using the flapless approach, and to compare this process with sites in which a synthetic bone graft was or was not inserted into the gap between the implant and the buccal bone plate. Lower bicuspids from 8 dogs were bilaterally extracted without the use of flaps, and 4 implants were installed in the alveoli in each side of the mandible and were positioned 2.0 mm from the buccal bone plate (gap). Four groups were devised: 2.0-mm subcrestal implants (3.3 x 8 mm) using bone grafts (SCTG), 2.0-mm subcrestal implants without bone grafts (SCCG), equicrestal implants (3.3 x 10 mm) with bone grafts (EGG), and equicrestal implants without bone grafts (ECCG). One week following the surgical procedures, metallic prostheses were installed, and within 12 weeks the dogs were sacrificed. The blocks containing the individual implants were turned sideways, and radiographic imaging was obtained to analyze the remodeling of the buccal bone plate. In the analysis of the resulting distance between the implant shoulder and the bone crest, statistically significant differences were found in the SCTG when compared to the ECTG (P = .02) and ECCG (P = .03). For mean value comparison of the resulting linear distance between the implant surface and the buccal plate, no statistically significant difference was found among all groups (P > .05). The same result was observed in the parameter for presence or absence of tissue formation between the implant surface and buccal plate. Equicrestally placed implants, in this methodology, presented little or no loss of the buccal bone. The subcrestally positioned implants presented loss of buccal bone, even though synthetic bone graft was used. The buccal bone, however, was always coronal to the implant shoulder.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To describe the healing of marginal defects below or above 1 mm of dimension around submerged implants in a dog model. Material and methods: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Two recipient sites were prepared and the marginal 5mm were widened to such an extent to obtain, after implant installation, a marginal gap of 0.5mm at the mesial site (small defect) and of 1.25mm at the distal site (large defect). Titanium healing caps were affixed to the implants and the flaps were sutured allowing a fully submerged healing. The experimental procedures were subsequently performed in the left side of the mandible. The timing of the experiments and sacrifices were planned in such a way to obtain biopsies representing the healing after 5, 10, 20 and 30 days. Ground sections were prepared and histomorphometrically analyzed. Results: The filling of the defect with newly formed bone was incomplete after 1 month of healing in all specimens. Bone formation occurred from the base and the lateral walls of the defects. A larger volume of new bone was formed in the large compared with the small defects. Most of the new bone at the large defect was formed between the 10- and the 20-day period of healing. After 1 month of healing, the outline of the newly formed bone was, however, located at a similar distance from the implant surface (about 0.4mm) at both defect types. Only minor newly formed bone in contact with the implant, starting from the base of the defects, was seen at the large defects (about 0.8mm) while a larger amount was detected at the small defects (about 2.2 mm). Conclusion: Marginal defects around titanium implants appeared to regenerate in 20-30 days by means of a distance osteogenesis. The bone fill of the defects was, however, incomplete after 1 month.