985 resultados para aortic valve
Resumo:
Osteoporosis and atherosclerosis seem to be epidemiologically correlated. Several medical conditions are risk factors for both osteoporosis and atheromatosis (i.e. age, diabetes, end stage renal disease, sedentarity, smoking), but a common pathogenic link may be present beyond this. The burden of cardiovascular events and of osteoporotic fracture is considerable for the health care system in term of costs and resources. However, both diseases are rarely managed together. This article is a review of the recent studies in this new field.
Resumo:
Lactococcus garvieae is a Gram-positive, catalase negative coccus arranged in pairs or short chains, well-known as a fish pathogen. We report a case of Infective Endocarditis (IE) by L. garvieae in a native valve from a 68-year-old male with unknown history of contact with raw fish and an extensive history of heart disease. This case highlights the reliability of MALDI-TOF MS compared to conventional methods in the identification of rare microorganisms like this.
Resumo:
Electrical and mechanical coupling of myocytes in heart and of smooth muscle cells in the aortic wall is thought to be mediated by intercellular channels aggregated at gap junctions. Connexin43 (Cx43) is one of the predominant membrane proteins forming junctional channels in the cardiovascular system. This study was undertaken to assess its expression during experimental hypertension. Rats were made hypertensive by clipping one renal artery (two-kidney, one-clip renal hypertension) or by administering deoxycorticosterone and salt (DOCA-salt hypertension). After four weeks, rats from both models showed a similar increase in intra-arterial mean blood pressure, as well as in the thickness of both aorta and heart walls. Northern blot analysis showed that, compared to controls, hypertensive rats expressed twice more Cx43 in aorta, but not in heart. These results suggest that localized mechanical forces induced by hypertension are major tissue-specific regulators of Cx43 expression.
Resumo:
Background: Chronic venous insufficiency (CVI) represents a major global health problem with increasing prevalence and morbidity. CVI is due to an incompetence of the venous valves, which causes venous reflux and distal venous hypertension. Several studies have focused on the replacement of diseased venous valves using xeno- and allogenic transplants, so far with moderate success due to immunologic and thromboembolic complications. Autologous cell-derived tissue-engineered venous valves (TEVVs) based on fully biodegradable scaffolds could overcome these limitations by providing non-immunogenic, non-thrombogenic constructs with remodeling and growth potential. Methods: Tri- and bicuspid venous valves (n=27) based on polyglycolic acid-poly-4-hydroxybutyrate composite scaffolds, integrated into self-expandable nitinol stents, were engineered from autologous ovine bone-marrow-derived mesenchymal stem cells (BM-MSCs) and endothelialized. After in vitro conditioning in a (flow) pulse duplicator system, the TEVVs were crimped (n=18) and experimentally delivered (n=7). The effects of crimping on the tissue-engineered constructs were investigated using histology, immunohistochemistry, scanning electron microscopy, grating interferometry (GI), and planar fluorescence reflectance imaging. Results: The generated TEVVs showed layered tissue formation with increasing collagen and glycosaminoglycan levels dependent on the duration of in vitro conditioning. After crimping no effects were found on the MSC level in scanning electron microscopy analysis, GI, histology, and extracellular matrix analysis. However, substantial endothelial cell loss was detected after the crimping procedure, which could be reduced by increasing the static conditioning phase. Conclusions: Autologous living small-diameter TEVVs can be successfully fabricated from ovine BM-MSCs using a (flow) pulse duplicator conditioning approach. These constructs hold the potential to overcome the limitations of currently used non-autologous replacement materials and may open new therapeutic concepts for the treatment of CVI in the future.
Resumo:
BACKGROUND: Control of hemorrhage in patients with active bleeding from rupture of the aortic arch is difficult, because of the location of the bleeding and the impossibility of cross-clamping the aorta without interfering with cerebral perfusion. A precise and swift plan of management helped us salvage some patients and prompted us to review our experience. METHODS: Six patients with active bleeding of the aortic arch in the mediastinum and pericardial cavity (5 patients) or left pleural cavity (1 patient), treated between 1992 and 1996, were reviewed. Bleeding was reduced by keeping the mediastinum under local tension (3 patients) or by applying compression on the bleeding site (2 patients), or both (1 patient) while circulatory support, retransfusion of aspirated blood, and hypothermia were established. The diseased aortic arch was replaced during deep hypothermic circulatory arrest, which ranged from 25 to 40 minutes. In 3 patients, the brain was further protected by retrograde (2 patients) or antegrade (1 patient) cerebral perfusion. RESULTS: Hemorrhage from the aortic arch was controlled in all patients. Two patients died postoperatively, one of respiratory failure and the other of abdominal sepsis. Recovery of neurologic function was assessed and complete in all patients. The 4 survivors are well 8 to 49 months after operation. CONCLUSIONS: An approach relying on local tamponade to reduce bleeding, rapid establishment of circulatory support and hypothermia, retransfusion of aspirated blood, and swift repair of the aortic arch under circulatory arrest allows salvage of patients with active bleeding from an aortic arch rupture.
Resumo:
BACKGROUND: The usual treatment of blunt aortic injury (BAI) is prompt surgery. Frequently severe injuries to the brain or lungs exclude further surgical treatment. The purpose of this study is to assess the feasibility of placing endovascular stent-grafts. METHODS: From 1992 through 1999, in our primary and referral trauma center, 26 acute BAI, 21 males and 5 females, mean age 40.2+/-16.3 yrs were diagnosed. The last 4 patients underwent prospectively endovascular repair with Talent endograft. Endoprosthesis parameters were measured on three-dimensional spiral CT reconstruction. While waiting for devices, blood pressure was aggressively lowered and aortic lesions were monitored by transesophageal echography. RESULTS: Stent-graft deployment was successful in all 4 patients. There were no complications of endoleak, stent migration, paraplegia or death. Angiographic exclusion was complete in all 4 patients. CT scans at a mean follow-up of 11+/-5 months showed complete healing of the aortic wall in all patients. CONCLUSIONS: For stable acute BAI, endovascular stent-graft repair is feasible and safe, and is an effective therapeutic alternative to open surgery. Because of the normal proximal and distal wall in aortic injuries, endoluminal treatment might be the therapy of choice in the near future.
Resumo:
OBJECTIVES: Prevalence of abdominal aortic aneurysms (AAA) is not exactly known among patients with coronary artery disease (CAD) who are considered for surgical revascularisation. We evaluated the value of screening AAA among coronary patients admitted in our cardiovascular surgery unit. METHODS: Over a 24-month period, an abdominal echography was proposed to male patients aged 60 or more while hospitalised for surgical coronary revascularisation. Patients with previous investigation of the aorta were excluded. The aorta was considered aneurysmal when the anterior-posterior diameter was of 30 mm or more. RESULTS: Three hundred and ninety-five consecutive patients all accepted a proposed abdominal echographic screening for AAA. Forty unsuspected AAA were detected (10.1%). The mean diameter was 38.9 +/- 1.3 mm. Four AAA were larger than 50 mm and considered for surgery after the CABG procedure. Surveillance was proposed to the other 36, especially the 10 patients with an AAA larger than 40 mm. Patients with AAA were significantly older than those without AAA (71.3 +/- 0.8 vs. 69.4 +/- 0.3 years, P<0.05). Smoking history (P<0.05) and hypertension (P<0.05) were also associated more frequently with AAA. More than 16% of the patients being smokers and suffering hypertension presented with unsuspected AAA. CONCLUSIONS: In-hospital screening of AAA is very efficient among patients with coronary artery disease. Therefore, patients with CAD may be considered for routine AAA screening.
Resumo:
BACKGROUND: In chronic kidney disease (CKD) patients, the intake of calcium-based phosphate binders is associated with a marked progression of coronary artery and aortic calcification, in contrast to patients receiving calcium-free phosphate binders. The aim of this study was to reexamine the role of calcium carbonate in vascular calcification and to analyse its effect on aortic calcification-related gene expression in chronic renal failure (CRF). METHODS: Mice deficient in apolipoprotein E underwent either sham operation or subtotal nephrectomy to create CRF. They were then randomly assigned to one of the three following groups: a control non-CRF group and a CRF group fed on standard diet, and a CRF group fed on calcium carbonate enriched diet, for a period of 8 weeks. Aortic atherosclerotic plaque and calcification were evaluated using quantitative morphologic image processing. Aortic gene and protein expression was examined using immunohistochemistry and Q-PCR methods. RESULTS: Calcium carbonate supplementation was effective in decreasing serum phosphorus but was associated with a higher serum calcium concentration. Compared with standard diet, calcium carbonate enriched diet unexpectedly induced a significant decrease of both plaque (p<0.05) and non-plaque-associated calcification surface (p<0.05) in CRF mice. It also increased osteopontin (OPN) protein expression in atherosclerotic lesion areas of aortic root. There was also a numerical increase in OPN and osteoprotegerin gene expression in total thoracic aorta but the difference did not reach the level of significance. Finally, calcium carbonate did not change the severity of atherosclerotic lesions. CONCLUSION: In this experimental model of CRF, calcium carbonate supplementation did not accelerate but instead decreased vascular calcification. If our observation can be extrapolated to humans, it appears to question the contention that calcium carbonate supplementation, at least when given in moderate amounts, necessarily enhances vascular calcification. It is also compatible with the hypothesis of a preponderant role of phosphorus over that of calcium in promoting vascular calcification in CRF.
Resumo:
BACKGROUND: Knowledge in the aetiopathogeny of aortic disease helps to characterise aortic lesions better and determine the risk of evolution and therapeutic strategies as well. This article focusses on aneurysms and dissections, and excludes causes related to infection, systemic inflammatory diseases and trauma. METHODS AND RESULTS: The biomedical literature of the past 10 years has been reviewed here. Aortic diseases are heterogeneous along the aorta as far as their genetic determinants, contribution of smooth muscle cells, inflammation and thrombus formation are concerned. Degradation of extracellular matrix by proteases causing aortic disease is a 'terminal' event, modulated by genetic background, haemodynamic strain, cellular events and thrombus formation. New genetic determinants of aortic disease have been identified. Proteases degrading the aortic wall are derived from a variety of cell types in addition to macrophages, including neutrophils on the luminal thrombus, mesenchymal and endothelial cells in the wall. Smooth muscle cells contribute to aortic wall homeostasis against inflammation and proteolysis. The degradation of the wall is followed by, or paralleled with, a failure of aortic reconstruction. CONCLUSIONS: Aortic diseases are diverse, and involve a multiplicity of biological systems in the vascular wall and at the interface with blood. Future research needs to unravel distinct cellular and molecular mechanisms causing the clinical events, in particular, dissection, expansion of already formed aneurysms and rupture.
Resumo:
BACKGROUND: The clinical profile and outcome of nosocomial and non-nosocomial health care-associated native valve endocarditis are not well defined. OBJECTIVE: To compare the characteristics and outcomes of community-associated and nosocomial and non-nosocomial health care-associated native valve endocarditis. DESIGN: Prospective cohort study. SETTING: 61 hospitals in 28 countries. PATIENTS: Patients with definite native valve endocarditis and no history of injection drug use who were enrolled in the ICE-PCS (International Collaboration on Endocarditis Prospective Cohort Study) from June 2000 to August 2005. MEASUREMENTS: Clinical and echocardiographic findings, microbiology, complications, and mortality. RESULTS: Health care-associated native valve endocarditis was present in 557 (34%) of 1622 patients (303 with nosocomial infection [54%] and 254 with non-nosocomial infection [46%]). Staphylococcus aureus was the most common cause of health care-associated infection (nosocomial, 47%; non-nosocomial, 42%; P = 0.30); a high proportion of patients had methicillin-resistant S. aureus (nosocomial, 57%; non-nosocomial, 41%; P = 0.014). Fewer patients with health care-associated native valve endocarditis had cardiac surgery (41% vs. 51% of community-associated cases; P < 0.001), but more of the former patients died (25% vs. 13%; P < 0.001). Multivariable analysis confirmed greater mortality associated with health care-associated native valve endocarditis (incidence risk ratio, 1.28 [95% CI, 1.02 to 1.59]). LIMITATIONS: Patients were treated at hospitals with cardiac surgery programs. The results may not be generalizable to patients receiving care in other types of facilities or to those with prosthetic valves or past injection drug use. CONCLUSION: More than one third of cases of native valve endocarditis in non-injection drug users involve contact with health care, and non-nosocomial infection is common, especially in the United States. Clinicians should recognize that outpatients with extensive out-of-hospital health care contacts who develop endocarditis have clinical characteristics and outcomes similar to those of patients with nosocomial infection. PRIMARY FUNDING SOURCE: None.
Resumo:
Postmortem imaging, including postmortem computed tomography angiography, has become an integral tool in forensic investigation in recent years. A relatively new technique, multiphase postmortem computed tomography angiography, allows detailed visualization of the vascular system and makes it possible to evaluate the dynamic perfusion of aortic branches, including the coronary arteries. Here, we report a case of aortic dissection involving the ascending aorta (type A) with coronary and carotid malperfusion. This case illustrates the complementary use of many of the diagnostic tools that are now available in forensic practice, from imaging to conventional autopsy to pathologic techniques such as immunohistochemistry.
Resumo:
Messages à retenir: Les séquences de ciné MR sont utiles pour rechercher une bicuspidie. Les séquences en contraste de phase permettent de mesurer les vitesses et flux transvalvulaires. La fraction de régurgitation est corrélée à la sévérité de l'insuffisance aortique. Une planimétrie peut être effectuée sur les séquences de ciné MR ou de flux. Résumé: L'étude de la valve aortique en IRM nécessite un placement rigoureux des plans de coupes à partir de 2 incidences orthogonales passant par la chambre de chasse. Les séquences de ciné IRM permettent une analyse dynamique de l'ouverture de la valve et sont utiles pour rechercher une bicuspidie et une dilatation de l'aorte. Leur sensibilité au flux turbulents est relativement faible vu leur TE court, à l'inverse des séquences en écho de gradient à TE long. Les séquences de ciné MR permettent également de calculer les volumes ventriculaires gauches et la fraction d'éjection, paramètres importants dans le traitement. Les séquences en contraste permettent de mesurer la vitesse trans-valvulaire et de calculer le volume éjecté dans l'aorte et le volume régurgité dans le ventricule gauche. Elles peuvent être réalisées dans le plan du flux ou au travers du plan. Il est important de régler correctement la vitesse de codage maximale afin d'éviter des erreurs de codage de vitesse (phénomène d'"aliasing"). Dans le cadre d'une insuffisance aortique, le ratio volume régurgité / volume éjecté, appelé fraction de régurgitation, est relié à la sévérité de la valvulopathie. L'IRM peut également permettre de réaliser une planimétrie de l'orifice valvulaire aortique.