996 resultados para Variable frequency oscillators


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geographic differences in frequency and azole resistance among Candida glabrata may impact empiric antifungal therapy choice. We examined geographic variation in isolation and azole susceptibility of C. glabrata. We examined 23 305 clinical isolates of C. glabrata during ARTEMIS DISK global surveillance. Susceptibility testing to fluconazole and voriconazole was assessed by disk diffusion, and the results were grouped by geographic location: North America (NA) (2470 isolates), Latin America (LA) (2039), Europe (EU) (12 439), Africa and the Middle East (AME) (728), and Asia-Pacific (AP) (5629). Overall, C. glabrata accounted for 11.6% of 201 653 isolates of Candida and varied as a proportion of all Candida isolated from 7.4% in LA to 21.1% in NA. Decreased susceptibility (S) to fluconazole was observed in all geographic regions and ranged from 62.8% in AME to 76.7% in LA. Variation in fluconazole susceptibility was observed within each region: AP (range, 50-100% S), AME (48-86.9%), EU (44.8-88%), LA (43-92%), and NA (74.5-91.6%). Voriconazole was more active than fluconazole (range, 82.3-84.2% S) with similar regional variation. Among 22 sentinel sites participating in ARTEMIS from 2001 through 2007 (84 140 total isolates, 8163 C. glabrata), the frequency of C. glabrata isolation increased in 14 sites and the frequency of fluconazole resistance (R) increased in 11 sites over the 7-year period of study. The sites with the highest cumulative rates of fluconazole R were in Poland (22% R), the Czech Republic (27% R), Venezuela (27% R), and Greece (33% R). C. glabrata was most often isolated from blood, normally sterile body fluids and urine. There is substantial geographic and institutional variation in both frequency of isolation and azole resistance among C. glabrata. Prompt species identification and fluconazole susceptibility testing are necessary to optimize therapy for invasive candidiasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using data from the Spanish household budget survey, we investigate life- cycle effects on several product expenditures. A latent-variable model approach is adopted to evaluate the impact of income on expenditures, controlling for the number of members in the family. Two latent factors underlying repeated measures of monetary and non-monetary income are used as explanatory variables in the expenditure regression equations, thus avoiding possible bias associated to the measurement error in income. The proposed methodology also takes care of the case in which product expenditures exhibit a pattern of infrequent purchases. Multiple-group analysis is used to assess the variation of key parameters of the model across various household life-cycle typologies. The analysis discloses significant life-cycle effects on the mean levels of expenditures; it also detects significant life-cycle effects on the way expenditures are affected by income and family size. Asymptotic robust methods are used to account for possible non-normality of the data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Les glissements de terrain représentent un des principaux risques naturels dans les régions montagneuses. En Suisse, chaque année les glissements de terrains causent des dégâts qui affectent les infrastructures et ont des coûts financiers importants. Une bonne compréhension des mécanismes des glissements peut permettre d'atténuer leur impact. Celle-ci passe notamment par la connaissance de la structure interne du glissement, la détermination de son volume et de son ou ses plans de glissement. Dans un glissement de terrain, la désorganisation et la présence de fractures dans le matériel déplacé engendre un changement des paramètres physiques et en particulier une diminution des vitesses de propagation des ondes sismiques ainsi que de la densité du matériel. Les méthodes sismiques sont de ce fait bien adaptées à l'étude des glissements de terrain. Parmi les méthodes sismiques, l'analyse de la dispersion des ondes de surface est une méthode simple à mettre en oeuvre. Elle présente l'avantage d'estimer les variations des vitesses de cisaillement avec la profondeur sans avoir spécifiquement recours à l'utilisation d'une source d'onde S et de géophones horizontaux. Sa mise en oeuvre en trois étapes implique la mesure de la dispersion des ondes de surface sur des réseaux étendus, la détermination des courbes de dispersion pour finir par l'inversion de ces courbes. Les modèles de vitesse obtenus à partir de cette procédure ne sont valides que lorsque les milieux explorés ne présentent pas de variations latérales. En pratique cette hypothèse est rarement vérifiée, notamment pour un glissement de terrain dans lequel les couches remaniées sont susceptibles de présenter de fortes hétérogénéités latérales. Pour évaluer la possibilité de déterminer des courbes de dispersion à partir de réseaux de faible extension des mesures testes ont été effectuées sur un site (Arnex, VD) équipé d'un forage. Un profil sismique de 190 m de long a été implanté dans une vallée creusée dans du calcaire et remplie par des dépôts glacio-lacustres d'une trentaine de mètres d'épaisseur. Les données acquises le long de ce profil ont confirmé que la présence de variations latérales sous le réseau de géophones affecte l'allure des courbes de dispersion jusqu'à parfois empêcher leur détermination. Pour utiliser l'analyse de la dispersion des ondes de surface sur des sites présentant des variations latérales, notre approche consiste à déterminer les courbes de dispersions pour une série de réseaux de faible extension, à inverser chacune des courbes et à interpoler les différents modèles de vitesse obtenus. Le choix de la position ainsi que de l'extension des différents réseaux de géophones est important. Il tient compte de la localisation des hétérogénéités détectées à partir de l'analyse de sismique réfraction, mais également d'anomalies d'amplitudes observées sur des cartes qui représentent dans le domaine position de tir - position du récepteur, l'amplitude mesurée pour différentes fréquences. La procédure proposée par Lin et Lin (2007) s'est avérée être une méthode efficace permettant de déterminer des courbes de dispersion à partir de réseaux de faible extension. Elle consiste à construire à partir d'un réseau de géophones et de plusieurs positions de tir un enregistrement temps-déports qui tient compte d'une large gamme de distances source-récepteur. Au moment d'assembler les différentes données une correction de phase est appliquée pour tenir compte des hétérogénéités situées entre les différents points de tir. Pour évaluer cette correction nous suggérons de calculer pour deux tir successif la densité spectrale croisée des traces de même offset: Sur le site d'Arnex, 22 courbes de dispersions ont été déterminées pour de réseaux de géophones de 10 m d'extension. Nous avons également profité du forage pour acquérir un profil de sismique verticale en ondes S. Le modèle de vitesse S déduit de l'interprétation du profil de sismique verticale est utilisé comme information à priori lors l'inversion des différentes courbes de dispersion. Finalement, le modèle en deux dimension qui a été établi grâce à l'analyse de la dispersion des ondes de surface met en évidence une structure tabulaire à trois couches dont les limites coïncident bien avec les limites lithologiques observées dans le forage. Dans celui-ci des argiles limoneuses associées à une vitesse de propagation des ondes S de l'ordre de 175 m/s surmontent vers 9 m de profondeur des dépôts de moraine argilo-sableuse caractérisés par des vitesses de propagation des ondes S de l'ordre de 300 m/s jusqu'à 14 m de profondeur et supérieur ou égal à 400 m/s entre 14 et 20 m de profondeur. Le glissement de la Grande Combe (Ballaigues, VD) se produit à l'intérieur du remplissage quaternaire d'une combe creusée dans des calcaires Portlandien. Comme dans le cas du site d'Arnex les dépôts quaternaires correspondent à des dépôts glacio-lacustres. Dans la partie supérieure la surface de glissement a été localisée à une vingtaine de mètres de profondeur au niveau de l'interface qui sépare des dépôts de moraine jurassienne et des dépôts glacio-lacustres. Au pied du glissement 14 courbes de dispersions ont été déterminées sur des réseaux de 10 m d'extension le long d'un profil de 144 m. Les courbes obtenues sont discontinues et définies pour un domaine de fréquence de 7 à 35 Hz. Grâce à l'utilisation de distances source-récepteur entre 8 et 72 m, 2 à 4 modes de propagation ont été identifiés pour chacune des courbes. Lors de l'inversion des courbes de dispersion la prise en compte des différents modes de propagation a permis d'étendre la profondeur d'investigation jusqu'à une vingtaine de mètres de profondeur. Le modèle en deux dimensions permet de distinguer 4 couches (Vs1 < 175 m/s, 175 m/s < Vs2 < 225 m/s, 225 m/s < Vs3 < 400 m/s et Vs4 >.400 m/s) qui présentent des variations d'épaisseur. Des profils de sismiques réflexion en ondes S acquis avec une source construite dans le cadre de ce travail, complètent et corroborent le modèle établi à partir de l'analyse de la dispersion des ondes de surface. Un réflecteur localisé entre 5 et 10 m de profondeur et associé à une vitesse de sommation de 180 m/s souligne notamment la géométrie de l'interface qui sépare la deuxième de la troisième couche du modèle établi à partir de l'analyse de la dispersion des ondes de surface. Abstract Landslides are one of the main natural hazards in mountainous regions. In Switzerland, landslides cause damages every year that impact infrastructures and have important financial costs. In depth understanding of sliding mechanisms may help limiting their impact. In particular, this can be achieved through a better knowledge of the internal structure of the landslide, the determination of its volume and its sliding surface or surfaces In a landslide, the disorganization and the presence of fractures in the displaced material generate a change of the physical parameters and in particular a decrease of the seismic velocities and of the material density. Therefoe, seismic methods are well adapted to the study of landslides. Among seismic methods, surface-wave dispersion analysis is a easy to implement. Through it, shearwave velocity variations with depth can be estimated without having to resort to an S-wave source and to horizontal geophones. Its 3-step implementation implies measurement of surface-wave dispersion with long arrays, determination of the dispersion curves and finally inversion of these curves. Velocity models obtained through this approach are only valid when the investigated medium does not include lateral variations. In practice, this assumption is seldom correct, in particular for landslides in which reshaped layers likely include strong lateral heterogeneities. To assess the possibility of determining dispersion curves from short array lengths we carried out tests measurements on a site (Arnex, VD) that includes a borehole. A 190 m long seismic profile was acquired in a valley carved into limestone and filled with 30 m of glacio-lacustrine sediments. The data acquired along this profile confirmed that the presence of lateral variations under the geophone array influences the dispersion-curve shape so much that it sometimes preventes the dispersion curves determination. Our approach to use the analysis of surface-wave dispersion on sites that include lateral variations consists in obtaining dispersion curves for a series of short length arrays; inverting each so obtained curve and interpolating the different obtained velocity model. The choice of the location as well as the geophone array length is important. It takes into account the location of the heterogeneities that are revealed by the seismic refraction interpretation of the data but also, the location of signal amplitude anomalies observed on maps that represent, for a given frequency, the measured amplitude in the shot position - receiver position domain. The procedure proposed by Lin and Lin (2007) turned out to be an efficient one to determine dispersion curves using short extension arrays. It consists in building a time-offset from an array of geophones with a wide offset range by gathering seismograms acquired with different source-to-receiver offsets. When assembling the different data, a phase correction is applied in order to reduce static phase error induced by lateral variation. To evaluate this correction, we suggest to calculate, for two successive shots, the cross power spectral density of common offset traces. On the Arnex site, 22 curves were determined with 10m in length geophone-arrays. We also took advantage of the borehole to acquire a S-wave vertical seismic profile. The S-wave velocity depth model derived from the vertical seismic profile interpretation is used as prior information in the inversion of the dispersion-curves. Finally a 2D velocity model was established from the analysis of the different dispersion curves. It reveals a 3-layer structure in good agreement with the observed lithologies in the borehole. In it a clay layer with a shear-wave of 175 m/s shear-wave velocity overlies a clayey-sandy till layer at 9 m depth that is characterized down to 14 m by a 300 m/s S-wave velocity; these deposits have a S-wave velocity of 400 m/s between depths of 14 to 20 m. The La Grand Combe landslide (Ballaigues, VD) occurs inside the Quaternary filling of a valley carved into Portlandien limestone. As at the Arnex site, the Quaternary deposits correspond to glaciolacustrine sediments. In the upper part of the landslide, the sliding surface is located at a depth of about 20 m that coincides with the discontinuity between Jurassian till and glacio-lacustrine deposits. At the toe of the landslide, we defined 14 dispersion curves along a 144 m long profile using 10 m long geophone arrays. The obtained curves are discontinuous and defined within a frequency range of 7 to 35 Hz. The use of a wide range of offsets (from 8 to 72 m) enabled us to determine 2 to 4 mode of propagation for each dispersion curve. Taking these higher modes into consideration for dispersion curve inversion allowed us to reach an investigation depth of about 20 m. A four layer 2D model was derived (Vs1< 175 m/s, 175 m/s <Vs2< 225 m/s, 225 m/s < Vs3 < 400 m/s, Vs4> 400 m/s) with variable layer thicknesses. S-wave seismic reflection profiles acquired with a source built as part of this work complete and the velocity model revealed by surface-wave analysis. In particular, reflector at a depth of 5 to 10 m associated with a 180 m/s stacking velocity image the geometry of the discontinuity between the second and third layer of the model derived from the surface-wave dispersion analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reliable and long-term expression of transgenes remain significant challenges for gene therapy and biotechnology applications, especially when antibiotic selection procedures are not applicable. In this context, transposons represent attractive gene transfer vectors because of their ability to promote efficient genomic integration in a variety of mammalian cell types. However, expression from genome-integrating vectors may be inhibited by variable gene transcription and/or silencing events. In this study, we assessed whether inclusion of two epigenetic control elements, the human Matrix Attachment Region (MAR) 1-68 and X-29, in a piggyBac transposon vector, may lead to more reliable and efficient expression in CHO cells. We found that addition of the MAR 1-68 at the center of the transposon did not interfere with transposition frequency, and transgene expressing cells could be readily detected from the total cell population without antibiotic selection. Inclusion of the MAR led to higher transgene expression per integrated copy, and reliable expression could be obtained from as few as 2-4 genomic copies of the MAR-containing transposon vector. The MAR X-29-containing transposons was found to mediate elevated expression of therapeutic proteins in polyclonal or monoclonal CHO cell populations using a transposable vector devoid of selection gene. Overall, we conclude that MAR and transposable vectors can be used to improve transgene expression from few genomic transposition events, which may be useful when expression from a low number of integrated transgene copies must be obtained and/or when antibiotic selection cannot be applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Common variable immunodeficiency (CVID) is the most frequent primary immune deficiency. Recurrent infections are classical consequences of CVID, but their impact has been largely reduced by immunoglobulin replacement. CVID is also associated with various inflammatory and autoimmune manifestations resulting from abnormal cellular immunity. The lungs are especially affected by a recently described entity called granulomatous lymphocytic interstitial lung disease (GLILD). GLILD currently constitutes an important cause of morbidity and mortality in these patients. It is distinct from bronchiectasis secondary to recurrent infections, and presents similarities but also striking differences with sarcoidosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Congenital gonadotropin-releasing hormone (GnRH) deficiency manifests as absent or incomplete sexual maturation and infertility. Although the disease exhibits marked locus and allelic heterogeneity, with the causal mutations being both rare and private, one causal mutation in the prokineticin receptor, PROKR2 L173R, appears unusually prevalent among GnRH-deficient patients of diverse geographic and ethnic origins. To track the genetic ancestry of PROKR2 L173R, haplotype mapping was performed in 22 unrelated patients with GnRH deficiency carrying L173R and their 30 first-degree relatives. The mutation's age was estimated using a haplotype-decay model. Thirteen subjects were informative and in all of them the mutation was present on the same ~123 kb haplotype whose population frequency is ≤10%. Thus, PROKR2 L173R represents a founder mutation whose age is estimated at approximately 9000 years. Inheritance of PROKR2 L173R-associated GnRH deficiency was complex with highly variable penetrance among carriers, influenced by additional mutations in the other PROKR2 allele (recessive inheritance) or another gene (digenicity). The paradoxical identification of an ancient founder mutation that impairs reproduction has intriguing implications for the inheritance mechanisms of PROKR2 L173R-associated GnRH deficiency and for the relevant processes of evolutionary selection, including potential selective advantages of mutation carriers in genes affecting reproduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the extent and origin of muscle fatigue induced by short-pulse-low-frequency [conventional (CONV)] and wide-pulse-high-frequency (WPHF) neuromuscular electrical stimulation. We expected CONV contractions to mainly originate from depolarization of axonal terminal branches (spatially determined muscle fiber recruitment) and WPHF contractions to be partly produced via a central pathway (motor unit recruitment according to size principle). Greater neuromuscular fatigue was, therefore, expected following CONV compared with WPHF. Fourteen healthy subjects underwent 20 WPHF (1 ms-100 Hz) and CONV (50 μs-25 Hz) evoked isometric triceps surae contractions (work/rest periods 20:40 s) at an initial target of 10% of maximal voluntary contraction (MVC) force. Force-time integral of the 20 evoked contractions (FTI) was used as main index of muscle fatigue; MVC force loss was also quantified. Central and peripheral fatigue were assessed by voluntary activation level and paired stimulation amplitudes, respectively. FTI in WPHF was significantly lower than in CONV (21,717 ± 11,541 vs. 37,958 ± 9,898 N·s P<0,001). The reductions in MVC force (WPHF: -7.0 ± 2.7%; CONV: -6.2 ± 2.5%; P < 0.01) and paired stimulation amplitude (WPHF: -8.0 ± 4.0%; CONV: -7.4 ± 6.1%; P < 0.001) were similar between conditions, whereas no change was observed for voluntary activation level (P > 0.05). Overall, our results showed a different motor unit recruitment pattern between the two neuromuscular electrical stimulation modalities with a lower FTI indicating greater muscle fatigue for WPHF, possibly limiting the presumed benefits for rehabilitation programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: We previously reported increased benefit and reduced mortality after ultra-early stroke thrombolysis in a single center. We now explored in a large multicenter cohort whether extra benefit of treatment within 90 minutes from symptom onset is uniform across predefined stroke severity subgroups, as compared with later thrombolysis. METHODS: Prospectively collected data of consecutive ischemic stroke patients who received IV thrombolysis in 10 European stroke centers were merged. Logistic regression tested association between treatment delays, as well as excellent 3-month outcome (modified Rankin scale, 0-1), and mortality. The association was tested separately in tertiles of baseline National Institutes of Health Stroke Scale. RESULTS: In the whole cohort (n=6856), shorter onset-to-treatment time as a continuous variable was significantly associated with excellent outcome (P<0.001). Every fifth patient had onset-to-treatment time≤90 minutes, and these patients had lower frequency of intracranial hemorrhage. After adjusting for age, sex, admission glucose level, and year of treatment, onset-to-treatment time≤90 minutes was associated with excellent outcome in patients with National Institutes of Health Stroke Scale 7 to 12 (odds ratio, 1.37; 95% confidence interval, 1.11-1.70; P=0.004), but not in patients with baseline National Institutes of Health Stroke Scale>12 (odds ratio, 1.00; 95% confidence interval, 0.76-1.32; P=0.99) and baseline National Institutes of Health Stroke Scale 0 to 6 (odds ratio, 1.04; 95% confidence interval, 0.78-1.39; P=0.80). In the latter, however, an independent association (odds ratio, 1.51; 95% confidence interval, 1.14-2.01; P<0.01) was found when considering modified Rankin scale 0 as outcome (to overcome the possible ceiling effect from spontaneous better prognosis of patients with mild symptoms). Ultra-early treatment was not associated with mortality. CONCLUSIONS: IV thrombolysis within 90 minutes is, compared with later thrombolysis, strongly and independently associated with excellent outcome in patients with moderate and mild stroke severity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using data from the Spanish household budget survey, we investigate life-cycle effects on several product expenditures. A latent-variable model approach is adopted to evaluate the impact of income on expenditures, controlling for the number of members in the family. Two latent factors underlying repeated measures of monetary and non-monetary income are used as explanatory variables in the expenditure regression equations, thus avoiding possible bias associated to the measurement error in income. The proposed methodology also takes care of the case in which product expenditures exhibit a pattern of infrequent purchases. Multiple-group analysis is used to assess the variation of key parameters of the model across various household life-cycle typologies. The analysis discloses significant life-cycle effects on the mean levels of expenditures; it also detects significant life-cycle effects on the way expenditures are affected by income and family size. Asymptotic robust methods are used to account for possible non-normality of the data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although CD4 cell count monitoring is used to decide when to start antiretroviral therapy in patients with HIV-1 infection, there are no evidence-based recommendations regarding its optimal frequency. It is common practice to monitor every 3 to 6 months, often coupled with viral load monitoring. We developed rules to guide frequency of CD4 cell count monitoring in HIV infection before starting antiretroviral therapy, which we validated retrospectively in patients from the Swiss HIV Cohort Study.Methodology/Principal Findings: We built up two prediction rules ("Snap-shot rule" for a single sample and "Track-shot rule" for multiple determinations) based on a systematic review of published longitudinal analyses of CD4 cell count trajectories. We applied the rules in 2608 untreated patients to classify their 18 061 CD4 counts as either justifiable or superfluous, according to their prior >= 5% or < 5% chance of meeting predetermined thresholds for starting treatment. The percentage of measurements that both rules falsely deemed superfluous never exceeded 5%. Superfluous CD4 determinations represented 4%, 11%, and 39% of all actual determinations for treatment thresholds of 500, 350, and 200x10(6)/L, respectively. The Track-shot rule was only marginally superior to the Snap-shot rule. Both rules lose usefulness for CD4 counts coming near to treatment threshold.Conclusions/Significance: Frequent CD4 count monitoring of patients with CD4 counts well above the threshold for initiating therapy is unlikely to identify patients who require therapy. It appears sufficient to measure CD4 cell count 1 year after a count > 650 for a threshold of 200, > 900 for 350, or > 1150 for 500x10(6)/L, respectively. When CD4 counts fall below these limits, increased monitoring frequency becomes advisable. These rules offer guidance for efficient CD4 monitoring, particularly in resource-limited settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rockfall hazard zoning is usually achieved using a qualitative estimate of hazard, and not an absolute scale. In Switzerland, danger maps, which correspond to a hazard zoning depending on the intensity of the considered phenomenon (e.g. kinetic energy for rockfalls), are replacing hazard maps. Basically, the danger grows with the mean frequency and with the intensity of the rockfall. This principle based on intensity thresholds may also be applied to other intensity threshold values than those used in Switzerland for rockfall hazard zoning method, i.e. danger mapping. In this paper, we explore the effect of slope geometry and rockfall frequency on the rockfall hazard zoning. First, the transition from 2D zoning to 3D zoning based on rockfall trajectory simulation is examined; then, its dependency on slope geometry is emphasized. The spatial extent of hazard zones is examined, showing that limits may vary widely depending on the rockfall frequency. This approach is especially dedicated to highly populated regions, because the hazard zoning has to be very fine in order to delineate the greatest possible territory containing acceptable risks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the standard kernel density estimate, it is known that one can tune the bandwidth such that the expected L1 error is within a constant factor of the optimal L1 error (obtained when one is allowed to choose the bandwidth with knowledge of the density). In this paper, we pose the same problem for variable bandwidth kernel estimates where the bandwidths are allowed to depend upon the location. We show in particular that for positive kernels on the real line, for any data-based bandwidth, there exists a densityfor which the ratio of expected L1 error over optimal L1 error tends to infinity. Thus, the problem of tuning the variable bandwidth in an optimal manner is ``too hard''. Moreover, from the class of counterexamples exhibited in the paper, it appears thatplacing conditions on the densities (monotonicity, convexity, smoothness) does not help.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 357 house mice (Mus domesticus) from 83 localities uniformly distributed throughout Switzerland were screened for the presence of a homogenously staining region (HSR) on chromosome 1. Altogether 47 mice from 11 localities were HSR/+ or HSR/HSR. One sample of 11 individuals all had an HSR/HSR karyotype. Almost all mice with the variant were collected from the Rhone valley (HSR frequency: 61%) and Val Bregaglia (HSR frequency: 81%). For samples from most of the area of Switzerland, the HSR was absent. There was no strong association between the geographic distribution of the HSR and the areas of occurrence of metacentrics. However, at Chiggiogna the HSR was found on Rb (1.3). Possible explanations for the HSR polymorphism are discussed.