643 resultados para Valves cardiaques


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In industrial plants, oil and oil compounds are usually transported by closed pipelines with circular cross-section. The use of radiotracers in oil transport and processing industrial facilities allows calibrating flowmeters, measuring mean residence time in cracking columns, locate points of obstruction or leak in underground ducts, as well as investigating flow behavior or industrial processes such as in distillation towers. Inspection techniques using radiotracers are non-destructive, simple, economic and highly accurate. Among them, Total Count, which uses a small amount of radiotracer with known activity, is acknowledged as an absolute technique for flow rate measurement. A viscous fluid transport system, composed by four PVC pipelines with 13m length (12m horizontal and 1m vertical) and ½, ¾, 1 and 2-inch gauges, respectively, interconnected by maneuvering valves was designed and assembled in order to conduct the research. This system was used to simulate different flow conditions of petroleum compounds and for experimental studies of flow profile in the horizontal and upward directions. As 198Au presents a single photopeak (411,8 keV), it was the radioisotope chosen for oil labeling, in small amounts (6 ml) or around 200 kBq activity, and it was injected in the oil transport lines. A NaI scintillation detector 2”x 2”, with well-defined geometry, was used to measure total activity, determine the calibration factor F and, positioned after a homogenization distance and interconnected to a standardized electronic set of nuclear instrumentation modules (NIM), to detect the radioactive cloud.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ce projet illustre cinq études, mettant l'emphase sur le développement d'une nouvelle approche diagnostique cardiovasculaire afin d'évaluer le niveau d’oxygène contenu dans le myocarde ainsi que sa fonction microvasculaire. En combinant une séquence de résonance magnétique cardiovasculaire (RMC) pouvant détecter le niveau d’oxygène (OS), des manœuvres respiratoires ainsi que des analyses de gaz artériels peuvent être utilisés comme procédure non invasive destinée à induire une réponse vasoactive afin d’évaluer la réserve d'oxygénation, une mesure clé de la fonction vasculaire. Le nombre de tests diagnostiques cardiaques prescrits ainsi que les interventions, sont en pleine expansion. L'imagerie et tests non invasifs sont souvent effectués avant l’utilisation de procédures invasives. L'imagerie cardiaque permet d’évaluer la présence ou absence de sténoses coronaires, un important facteur économique dans notre système de soins de santé. Les techniques d'imagerie non invasives fournissent de l’information précise afin d’identifier la présence et l’emplacement du déficit de perfusion chez les patients présentant des symptômes d'ischémie myocardique. Néanmoins, plusieurs techniques actuelles requièrent la nécessité de radiation, d’agents de contraste ou traceurs, sans oublier des protocoles de stress pharmacologiques ou physiques. L’imagerie RMC peut identifier une sténose coronaire significative sans radiation. De nouvelles tendances d’utilisation de RMC visent à développer des techniques diagnostiques qui ne requièrent aucun facteur de stress pharmacologiques ou d’agents de contraste. L'objectif principal de ce projet était de développer et tester une nouvelle technique diagnostique afin d’évaluer la fonction vasculaire coronarienne en utilisant l' OS-RMC, en combinaison avec des manœuvres respiratoires comme stimulus vasoactif. Ensuite, les objectifs, secondaires étaient d’utilisés l’OS-RMC pour évaluer l'oxygénation du myocarde et la réponse coronaire en présence de gaz artériels altérés. Suite aux manœuvres respiratoires la réponse vasculaire a été validée chez un modèle animal pour ensuite être utilisé chez deux volontaires sains et finalement dans une population de patients atteints de maladies cardiovasculaires. Chez le modèle animal, les manœuvres respiratoires ont pu induire un changement significatif, mesuré intrusivement par débit sanguin coronaire. Il a été démontré qu’en présence d'une sténose coronarienne hémodynamiquement significative, l’OS-RMC pouvait détecter un déficit en oxygène du myocarde. Chez l’homme sain, l'application de cette technique en comparaison avec l'adénosine (l’agent standard) pour induire une vasodilatation coronarienne et les manœuvres respiratoires ont pu induire une réponse plus significative en oxygénation dans un myocarde sain. Finalement, nous avons utilisé les manœuvres respiratoires parmi un groupe de patients atteint de maladies coronariennes. Leurs myocardes étant altérées par une sténose coronaire, en conséquence modifiant ainsi leur réponse en oxygénation. Par la suite nous avons évalué les effets des gaz artériels sanguins sur l'oxygénation du myocarde. Ils démontrent que la réponse coronarienne est atténuée au cours de l’hyperoxie, suite à un stimuli d’apnée. Ce phénomène provoque une réduction globale du débit sanguin coronaire et un déficit d'oxygénation dans le modèle animal ayant une sténose lorsqu’un supplément en oxygène est donné. En conclusion, ce travail a permis d'améliorer notre compréhension des nouvelles techniques diagnostiques en imagerie cardiovasculaire. Par ailleurs, nous avons démontré que la combinaison de manœuvres respiratoires et l’imagerie OS-RMC peut fournir une méthode non-invasive et rentable pour évaluer la fonction vasculaire coronarienne régionale et globale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nos dias de hoje a sociedade exige níveis qualitativos de vida cada vez mais elevados, o que torna prioritária a conceção de sistemas eficientes, não poluidores, económicos e diversificados que permitam uma gestão integrada e racionalizada de recursos tão escasso como é o da água e da energia. Em sistemas de abastecimento de água, o uso de válvulas redutoras de pressão (VRP) visa a uniformização e controlo de pressões, promovendo uma perda de carga localizada que dissipa a energia hidráulica presente através da redução dos valores de pressão a jusante. Estas são fundamentais no controlo e redução de pressão. A utilização de microturbinas é uma alternativa sustentável para o controle de pressão e, simultaneamente, para a produção de energia elétrica. Trata-se de um método de mitigação para controlar as perdas referidas convergindo no âmbito da eficiência energética. Na perspetiva de promover um aproveitamento de energia nas redes de abastecimento de água, o presente trabalho sugere a substituição de válvulas redutoras de pressão (VRP) por microturbinas. Desse modo, apresenta-se um método automático de seleção de (i) local para implementação e (ii) projeto de microturbinas para sistemas de abastecimento de água. Para a modelação do funcionamento dos sistemas hidráulicos recorre-se ao simulador hidráulico EPANET. Esta ferramenta possibilita avaliação de caudais e pressões em todos os pontos da rede durante um determinado intervalo de tempo. A metodologia desenvolvida permite selecionar o local ideal no sistema hidráulico através de uma análise de cada secção conduta-nó escolhendo-se a melhor opção baseada na produção de energia. Depois da localização procede-se à seleção do tipo de turbina (Kaplan, Francis, Pelton e Cross-flow) que vai depender das características do sistema hidráulico. Na etapa seguinte apresenta-se os resultados obtidos pela turbina nomeadamente a produção de energia elétrica anual, o investimento necessário, o tempo de retorno e a rentabilização ao final de um período de 25 anos. Na última etapa da metodologia, de forma avaliar o comportamento do sistema final, realiza-se uma nova simulação da rede mas tendo em conta a introdução da microturbina no local. Apresentam-se alguns casos de estudo que validam a ferramenta desenvolvida. A metodologia desenvolvida é comparada com um caso de estudo real. Em ambos os exemplos simulados a metodologia aplicada permite obter soluções com ganhos energéticos significativos associados ao sistema. Apenas num dos exemplos se observaram que a implementação da microturbina no sistema hidráulico não seria economicamente rentável.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’insuffisance mitrale (IM) fonctionnelle est une complication fréquente des cardiopathies, causée par la dilatation du ventricule gauche (VG) qui empêche la valve de se fermer. L’insuffisance aortique (IA) est une condition associée à des valves mitrales (VM) inhabituellement grandes, et relativement peu d’IM malgré des VG très dilatés. Cet élargissement de la VM a le potentiel de prévenir l’IM dans les VG dilatés. Les mécanismes sont cependant peu compris : il n’est pas clair s’il s’agit d’une croissance active ou d’un étirement passif des feuillets. Également, le timing de l’adaptation valvulaire n’est pas connu. Notre hypothèse est que l’agrandissement de la valve mitrale en IA est un phénomène actif avec réactivation des mécanismes de croissance embryonnaire. Cent-onze rats ont été divisés en deux groupes : IA (perforation aortique) et contrôle. Les animaux ont été sacrifiés à 48 h, 1 semaine et 3 mois après la création du modèle. Des échocardiographies ont évalué la sévérité de l’IA, la présence d’IM et les dimensions du VG. Les valves ont été prélevées pour analyses microscopiques et moléculaires. La création de l’insuffisance aortique a entrainé une dilatation et une hypertrophie du VG. Malgré cette dilatation rapide du VG, aucun animal n’a développé de l’IM fonctionnelle. À l’échographie, le feuillet antérieur mitral était significativement plus long dans les groupes IA. Par microscopie, les feuillets étaient plus épais dés la première semaine. L’IA était associée à une surexpression de collagène α-SMA (un marqueur de myofibroblastes), TGF-β1 et MMP-2 dans le tissu valvulaire dès la première semaine. Les valves exposées à l’IA étaient également positives pour ces différents facteurs dés les premiers jours. L’agrandissement de la VM est un phénomène actif qui survient rapidement après la création de l’IA, en parallèle de la dilatation du VG. La stimulation de cette croissance dans d’autres pathologies pourrait contribuer à prévenir l’IM fonctionnelle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last years the need to develop more environmentally friendly and efficient cars as led to the development of several technologies to improve the performance of internal combustion engines, a large part of the innovations are focused in the auxiliary systems of the engine, including, the oil pump, this is an element of great importance in the dynamics of the engine as well a considerable energy consumer. Most solutions for oil pumps to this day are fixed displacement, for medium and high speeds, the pump flow rate is higher than the needs of the engine, this excess flow leads to the need for recirculation of the fluid which represents a waste of energy. Recently, technological advances in this area have led to the creation of variable displacement oil pumps, these have become a 'must have' due to the numerous advantages they bring, although the working principle of vane or piston pumps is relatively well known, the application of this technology for the automotive industry is new and brings new challenges. The focus of this dissertation is to develop a new concept of variable displacement system for automotive oil pumps. The main objective is to obtain a concept that is totally adaptable to existing solutions on the market (engines), both dimensionally as in performance specifications, having at the same time an innovative mechanical system for obtaining variable displacement. The developed design is a vane pump with variable displacement going in line with existing commercial solutions, however, the variation of the eccentricity commonly used to provide an variable displacement delivery is not used, the variable displacement is achieved without varying the eccentricity of the system but with a variation of the length of the pumping chamber. The principle of operation of the pump is different to existing solutions while maintaining the ability to integrate standard parts such as control valves and mechanical safety valves, the pump is compatible with commercial solutions in terms of interfaces for connection between engine systems and pump. A concept prototype of the product was obtained in order to better evaluate the validity of the concept. The developed concept represents an innovation in oil pumps design, being unique in its mechanical system for variable displacement delivery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

LINS, Filipe C. A. et al. Modelagem dinâmica e simulação computacional de poços de petróleo verticais e direcionais com elevação por bombeio mecânico. In: CONGRESSO BRASILEIRO DE PESQUISA E DESENVOLVIMENTO EM PETRÓLEO E GÁS, 5. 2009, Fortaleza, CE. Anais... Fortaleza: CBPDPetro, 2009.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[es] A lo largo de la historia, los villanos, ya sean reales o imaginarios, han tenido funciones útiles para la sociedad y a menudo han actuado como «válvulas de seguridad» para aliviar las presiones sociales. Esta es probablemente la razón por la que muchos «villanos» han sido definidos como «bandidos sociales», término utilizado originalmente por Eric Hobsbawm para referirse a un forajido quizás mejor ejemplificado por el personaje de Robin Hood en la tradición inglesa. Este bandido social, admirado por todos y en todas partes, que roba a los ricos y reparte el botín entre los pobres, actúa al margen de la ley y personifica asimismo la resistencia a la opresión social y una serie de virtudes más personales. En este artículo, vamos a analizar la forma en que el bandido inglés se ha convertido en un héroe mítico más que legendario. De hecho, el personaje de Robin Hood ha trascendido el tiempo y la cultura, y se ha convertido en el arquetipo del proscrito benevolente, un héroe popular nacido de las frustraciones de una clase inferior que considera que no hay leyes ni reglas en una sociedad injusta, sino la voluntad y el capricho de quien detenta el poder. [en] Throughout history, villains -whether real or imaginary- have served useful functions, especially those of “safety valves” for society. This is probably why many “villains” have been defined as “social bandits”, a term originally used by Eric Hobsbawm to refer to a type best exemplified in the Anglo-Saxon tradition by Robin Hood. This true and widely admired social bandit who steals from the rich and gives to the poor operates outside the law but at the same time personifies both group resistance to oppression and a number of more personal virtues. In this paper, we shall analyse the way in which the English bandit has become a mythical rather than a legendary hero. Indeed, the Robin Hood figure has transcended time and culture, and has become the archetype of the benevolent outlaw, a folk hero born of the frustrations of an underclass that sees the law as the will and whim of the privileged classes above them.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The off-cycle refrigerant mass migration has a direct influence on the on-cycle performance since compressor energy is necessary to redistribute the refrigerant mass. No studies, as of today, are available in the open literature which experimentally measured the lubricant migration within a refrigeration system during cycling or stop/start transients. Therefore, experimental procedures measuring the refrigerant and lubricant migration through the major components of a refrigeration system during stop/start transients were developed and implemented. Results identifying the underlying physics are presented. The refrigerant and lubricant migration of an R134a automotive A/C system-utilizing a fixed orifice tube, minichannel condenser, plate and fin evaporator, U-tube type accumulator and fixed displacement compressor-was measured across five sections divided by ball valves. Using the Quick-Closing Valve Technique (QCVT) combined with the Remove and Weigh Technique (RWT) using liquid nitrogen as the condensing agent resulted in a measurement uncertainty of 0.4 percent regarding the total refrigerant mass in the system. The determination of the lubricant mass distribution was achieved by employing three different techniques-Remove and Weigh, Mix and Sample, and Flushing. To employ the Mix and Sample Technique a device-called the Mix and Sample Device-was built. A method to separate the refrigerant and lubricant was developed with an accuracy-after separation-of 0.04 grams of refrigerant left in the lubricant. When applying the three techniques, the total amount of lubricant mass in the system was determined to within two percent. The combination of measurement results-infrared photography and high speed and real time videography-provide unprecedented insight into the mechanisms of refrigerant and lubricant migration during stop-start operation. During the compressor stop period, the primary refrigerant mass migration is caused by, and follows, the diminishing pressure difference across the expansion device. The secondary refrigerant migration is caused by a pressure gradient as a result of thermal nonequilibrium within the system and causes only vapor phase refrigerant migration. Lubricant migration is proportional to the refrigerant mass during the primary refrigerant mass migration. During the secondary refrigerant mass migration lubricant is not migrating. The start-up refrigerant mass migration is caused by an imbalance of the refrigerant mass flow rates across the compressor and expansion device. The higher compressor refrigerant mass flow rate was a result of the entrainment of foam into the U-tube of the accumulator. The lubricant mass migration during the start-up was not proportional to the refrigerant mass migration. The presence of water condensate on the evaporator affected the refrigerant mass migration during the compressor stop period. Caused by an evaporative cooling effect the evaporator held 56 percent of the total refrigerant mass in the system after three minutes of compressor stop time-compared to 25 percent when no water condensate was present on the evaporator coil. Foam entrainment led to a faster lubricant and refrigerant mass migration out of the accumulator than liquid entrainment through the hole at the bottom of the U-tube. The latter was observed for when water condensate was present on the evaporator coil because-as a result of the higher amount of refrigerant mass in the evaporator before start-up-the entrainment of foam into the U-tube of the accumulator ceased before the steady state refrigerant mass distribution was reached.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For this project I prepared a series of recitals featuring music for horn and percussion, in which the horn part featured extended horn techniques. For this project, I considered anything beyond the open or muted horn an extended technique. These techniques range from the common hand-stopped note passages to complex new techniques involving half-valves, multi-phonics, and more, for new sounds desired by the composer. There are several pieces written for solo horn and percussion, with ensembles ranging from simple duets to solo horn with a full percussion ensemble. However, few include extended techniques for the horn. All of these select pieces are lesser known because of their difficulty, primarily because of the challenge of the extended techniques requested by the composer. In the introduction to this paper I give a brief background to the project, where the current repertoire stands, and my experiences with commissioning works for this genre. I then give a brief history and how-to on the more common extended techniques, which were found in almost every piece. I separated these techniques so that they could be referenced in the performance notes without being extremely repetitive in their description. Then follows the main performance notes of the repertoire chosen, which includes a brief description of the piece itself and a longer discussion for performers and composers who wish to learn more about these techniques. In this section my primary focus is the extended techniques used and I provide score samples with permission to further the education of the next musicians to tackle this genre. All works performed for this project were recorded and accompany this paper in the Digital Repository at the University of Maryland (DRUM). The following works were included in this project: o Howard J. Buss, Dreams from the Shadows (2015) o Howard J. Buss, Night Tide (1995) o George Crumb, An Idyll for the Misbegotten, trans. Robert Patterson (1986/1997) o Charles Fernandez, Metamorphosis: A Horn’s Life, “Prenatal and Toddler” (2016, unfinished) o Helen Gifford, Of Old Angkor (1995) o Douglas Hill, Thoughtful Wanderings… (1990) o Pierre-Yves Level, Duetto pour Cor en Fa et Percussion (1999) o David Macbride, Elegy for Horn and Timpani (2009) o Brian Prechtl, A Song of David (1995) o Verne Reynolds, HornVibes (1986) o Pablo Salazar, Cincontar (2016) o Mark Schultz, Dragons in the Sky (1989) o Faye-Ellen Silverman, Protected Sleep (2007) o Charles Taylor, Sonata for Horn and Marimba (1991) o Robert Wolk, Tessellations (2016) With this project, I intend to promote these pieces and the techniques used to encourage more works written in this style, and reveal to fellow horn players that the techniques should not prevent these great works from being performed. Due to the lack of repertoire, I successfully commissioned new pieces featuring extended techniques, which were featured in the final recital.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La circulation extracorporelle (CEC) est une technique utilisée en chirurgie cardiaque effectuée des milliers de fois chaque jour à travers le monde. L’instabilité hémodynamique associée au sevrage de la CEC difficile constitue la principale cause de mortalité en chirurgie cardiaque et l’hypertension pulmonaire (HP) a été identifiée comme un des facteurs de risque les plus importants. Récemment, une hypothèse a été émise suggérant que l'administration prophylactique (avant la CEC) de la milrinone par inhalation puisse avoir un effet préventif et faciliter le sevrage de la CEC chez les patients atteints d’HP. Toutefois, cette indication et voie d'administration pour la milrinone n'ont pas encore été approuvées par les organismes réglementaires. Jusqu'à présent, la recherche clinique sur la milrinone inhalée s’est principalement concentrée sur l’efficacité hémodynamique et l'innocuité chez les patients cardiaques, bien qu’aucun biomarqueur n’ait encore été établi. La dose la plus appropriée pour l’administration par nébulisation n'a pas été déterminée, de même que la caractérisation des profils pharmacocinétiques (PK) et pharmacodynamiques (PD) suite à l'inhalation. L'objectif de notre recherche consistait à caractériser la relation exposition-réponse de la milrinone inhalée administrée chez les patients subissant une chirurgie cardiaque sous CEC. Une méthode analytique par chromatographie liquide à haute performance couplée à un détecteur ultraviolet (HPLC-UV) a été optimisée et validée pour le dosage de la milrinone plasmatique suite à l’inhalation et s’est avérée sensible et précise. La limite de quantification (LLOQ) était de 1.25 ng/ml avec des valeurs de précision intra- et inter-dosage moyennes (CV%) <8%. Des patients souffrant d’HP pour lesquels une chirurgie cardiaque sous CEC était prévue ont d’abord été recrutés pour une étude pilote (n=12) et, par la suite, pour une étude à plus grande échelle (n=28) où la milrinone (5 mg) était administrée par inhalation pré-CEC. Dans l'étude pilote, nous avons comparé l'exposition systémique de la milrinone peu après son administration avec un nébuliseur pneumatique ou un nébuliseur à tamis vibrant. L’efficacité des nébuliseurs en termes de dose émise et dose inhalée a également été déterminée in vitro. Dans l'étude à plus grande échelle conduite en utilisant exclusivement le nébuliseur à tamis vibrant, la dose inhalée in vivo a été estimée et le profil pharmacocinétique de la milrinone inhalée a été pleinement caractérisé aux niveaux plasmatique et urinaire. Le ratio de la pression artérielle moyenne sur la pression artérielle pulmonaire moyenne (PAm/PAPm) a été choisi comme biomarqueur PD. La relation exposition-réponse de la milrinone a été caractérisée pendant la période d'inhalation en étudiant la relation entre l'aire sous la courbe de l’effet (ASCE) et l’aire sous la courbe des concentrations plasmatiques (ASC) de chacun des patients. Enfin, le ratio PAm/PAPm a été exploré comme un prédicteur potentiel de sortie de CEC difficile dans un modèle de régression logistique. Les expériences in vitro ont démontré que les doses émises étaient similaires pour les nébuliseurs pneumatique (64%) et à tamis vibrant (68%). Cependant, la dose inhalée était 2-3 fois supérieure (46% vs 17%) avec le nébuliseur à tamis vibrant, et ce, en accord avec les concentrations plasmatiques. Chez les patients, en raison des variations au niveau des facteurs liés au circuit et au ventilateur causant une plus grande dose expirée, la dose inhalée a été estimée inférieure (30%) et cela a été confirmé après récupération de la dose de milrinone dans l'urine 24 h (26%). Les concentrations plasmatiques maximales (Cmax: 41-189 ng/ml) et l'ampleur de la réponse maximale ΔRmax-R0 (0-65%) ont été observées à la fin de l'inhalation (10-30 min). Les données obtenues suite aux analyses PK sont en accord avec les données publiées pour la milrinone intraveineuse. Après la période d'inhalation, les ASCE individuelles étaient directement reliées aux ASC (P=0.045). Enfin, notre biomarqueur PD ainsi que la durée de CEC ont été identifiés comme des prédicteurs significatifs de la sortie de CEC difficile. La comparaison des ASC et ASCE correspondantes a fourni des données préliminaires supportant une preuve de concept pour l'utilisation du ratio PAm/PAPm comme biomarqueur PD prometteur et justifie de futures études PK/PD. Nous avons pu démontrer que la variation du ratio PAm/PAPm en réponse à la milrinone inhalée contribue à la prévention de la sortie de CEC difficile.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Re-creating and understanding the origin of life represents one of the major challenges facing the scientific community. We will never know exactly how life started on planet Earth, however, we can reconstruct the most likely chemical pathways that could have contributed to the formation of the first living systems. Traditionally, prebiotic chemistry has investigated the formation of modern life’s precursors and their self-organisation under very specific conditions thought to be ‘plausible’. So far, this approach has failed to produce a living system from the bottom-up. In the work presented herein, two different approaches are employed to explore the transition from inanimate to living matter. The development of microfluidic technology during the last decades has changed the way traditional chemical and biological experiments are performed. Microfluidics allows the handling of low volumes of reagents with very precise control. The use of micro-droplets generated within microfluidic devices is of particular interest to the field of Origins of Life and Artificial Life. Whilst many efforts have been made aiming to construct cell-like compartments from modern biological constituents, these are usually very difficult to handle. However, microdroplets can be easily generated and manipulated at kHz rates, making it suitable for high-throughput experimentation and analysis of compartmentalised chemical reactions. Therefore, we decided to develop a microfluidic device capable of manipulating microdroplets in such a way that they could be efficiently mixed, split and sorted within iterative cycles. Since no microfluidic technology had been developed before in the Cronin Group, the first chapter of this thesis describes the soft lithographic methods and techniques developed to fabricate microfluidic devices. Also, special attention is placed on the generation of water-in-oil microdroplets, and the subsequent modules required for the manipulation of the droplets such as: droplet fusers, splitters, sorters and single/multi-layer micromechanical valves. Whilst the first part of this thesis describes the development of a microfluidic platform to assist chemical evolution, finding a compatible set of chemical building blocks capable of reacting to form complex molecules with endowed replicating or catalytic activity was challenging. Abstract 10 Hence, the second part of this thesis focuses on potential chemistry that will ultimately possess the properties mentioned above. A special focus is placed on the formation of peptide bonds from unactivated amino acids, despite being one of the greatest challenges in prebiotic chemistry. As opposed to classic prebiotic experiments, in which a specific set of conditions is studied to fit a particular hypothesis, we took a different approach: we explored the effects of several parameters at once on a model polymerisation reaction, without constraints on hypotheses on the nature of optimum conditions or plausibility. This was facilitated by development of a new high-throughput automated platform, allowing the exploration of a much larger number of parameters. This led us to discover that peptide bond formation is less challenging than previously imagined. Having established the right set of conditions under which peptide bond formation was enhanced, we then explored the co-oligomerisation between different amino acids, aiming for the formation of heteropeptides with different structure or function. Finally, we studied the effect of various environmental conditions (rate of evaporation, presence of salts or minerals) in the final product distribution of our oligomeric products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os solenóides para eletroválvulas, em conjunto com outros produtos e equipamentos, permitem a automação dos sistemas de distribuição de águas não potáveis, como, por exemplo, em sistemas de rega. Deste modo é possível controlar diversos parâmetros, como o caudal e a pressão da água que passa na válvula, podendo estes ser fiscalizados à distância. Neste trabalho, foram desenvolvidos solenóides para acoplar a válvulas que se destinam à rega agrícola, comercializadas pela empresa JPrior, Fábrica de Plásticos, Lda. Para o efeito, foram definidos vários processos necessários para a criação de uma linha piloto de pré industrialização destes dispositivos. Etapas como a conceção do dispositivo, prototipagem, testes de temperatura, consumo de corrente, estabilidade eletromecânica e testes de desempenho associados a diferentes valores de pressão e de caudal de funcionamento, foram essenciais para este desenvolvimento, assim como, análises estruturais e morfológicas do material que constitui o núcleo dos solenóides. Além disso, procurou-se responder às necessidades do mercado numa perspetiva mais completa do que a existente. Para isso, foram produzidos dois tipos de solenóides de 24 V AC, com pressões máximas de funcionamento de 4 bar e de 12 bar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hoje em dia a preocupação ambiental e a economia são fatores de sustentabilidade que são tidos em conta em países desenvolvidos, especialmente no seio da União Europeia. Reduzir os consumos de energia é, portanto, um ponto-chave para a redução das emissões de gases com efeito de estufa e aumentar a dependência das energias renováveis. Consequentemente surge então a necessidade de aumentar a eficiência dos equipamentos, em particular no presente caso, equipamentos de refrigeração. Para isso foi adotado pela Comissão Europeia uma rotulagem nos produtos consumidores de energia, em particular na refrigeração, os frigoríficos e congeladores domésticos permitindo informar o consumidor para os equipamentos mais eficientes. Mais recentemente, frigoríficos comerciais e profissionais também terão obrigatoriedade de incluir um rótulo energético na parte externa dos mesmos. Nesses rótulos estão incluídas várias informações técnicas do aparelho representadas de uma forma compreensível e lúdica aos olhos do consumidor mais leigo, entre as quais as classes de eficiência energética. As classes de eficiência energética caracterizam-se pela componente tecnológica dos frigoríficos. Perceber quais os componentes e materiais em particular que promovem uma melhor eficiência, quantificar a sua influência e avaliar os seus custos de integração torna-se assim essencial para toda a cadeia envolvida na produção destes equipamentos. Os fluídos frigorigénios e compressores aparentam ser os que mais exercem influência na eficiência de frigoríficos de baixa potência. Tubos capilares com trocador de calor são uma escolha mais eficiente comparado com o tubo capilar padrão que é utilizado nestes frigoríficos. Por forma a obter informação adicional e relevante do ponto de vista da análise energética realizaram-se simulações para determinação do consumo elétrico anual com recurso ao software Pack Calculation Pro. Entre os fluídos frigorigénios R-134a, R-22 e R-410a, os compressores scroll apresentaram consumos mais reduzidos (no máximo de 16%) do que os compressores alternativos. No caso do amoníaco (R-717) os compressores alternativos consumiram em média 14% menos do que os compressores parafuso. O recurso a velocidade variável em compressores permite reduzir o consumo na ordem dos 25%. Válvulas de expansão eletrónicas trazem reduções no consumo de 1,5% quando comparadas com válvulas de expansão termostáticas em compressores de velocidade variável. O propano (R-290) é um gás que mostra ter um melhor desempenho do que o R-134a e R404a em vários compressores, consumindo 16% menos do que o R-404a. Em função da temperatura exterior, o R-290 também apresentou um bom desempenho consumindo em climas quentes (Belém, Brasil) 24% menos do que o R-404a.