970 resultados para Tissue Analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10,12.5, 15 mm crown-to-implant ratio 1:1, 1.25:1, 1.5:1, respectively). It was designed using three 3-Dmodels. Each model was developed with a mandibular segment of bone block including an internal hexagon implant supporting a screw-retained, single metalceramic crown. The crown height was set at 10, 12.5, and 15 mm with crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. The applied forces were 200 N (axial) and 100 N (oblique). The increase of crown height showed differences with the oblique load in some situations. By von Mises'criterion, a high stress area was concentrated at the implant/fixation screw and abutment/implant interfaces at crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. Using the maxiinum principal criteria, the buccal regions showed higher traction stress intensity, whereas the distal regions showed the largest compressive stress in all models. The increase of C/I ratio must be carefully evaluated by the dentist since the increase of this C/I ratio is proportional to the increase of average stress for both screw fixation (C/I 1:1 to 1:1.25 ratio = 30.1% and C/I 1:1 to 1 :1.5 ratio = 46.3%) and bone tissue (C/I 1:1 to 1:1.25 ratio = 30% and C/I 1:1 to 1:1.5 ratio = 51.5%). (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bacterial cellulose (BC) has become established as a remarkably versatile biomaterial and can be used in a wide variety of scientific applications, especially for medical devices. In this work, the bacterial cellulose fermentation process is modified by the addition of chondroitin sulfate and hyaluronic acid (1% w/w) to the culture medium before the bacteria is inoculated. Besides, biomimetic precipitation of calcium phosphate of biological interest from simulated body fluid on bacterial cellulose was studied. Chondroitin sulfate and hyaluronic acid influences in bacterial cellulose were analyzed using transmission infrared spectroscopy (FTIR), XRD (X-ray diffraction) and scanning electron microscopy (SEM). FTIR analysis showed interaction between bacterial cellulose nanobiocomposites and calcium phosphate and XRD demonstrated amorphous calcium phosphate and calcium chloride on bacterial cellulose nanobiocomposites. SEM images confirmed incorporation of calcium phosphate in bacterial cellulose nanobiocomposites surface with different calcium phosphate particles morphology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synaptonemal complex (SC) was analyzed in four F1 hybrids of Bos taurus taurus and B. taurus indicus including Gyr-Simmental (G-S), Nelore Simmental (N-S), Gyr-Holstein-Friesian (G-H) and Nelore-Piemontese (N-P). We analysed the frequency of various types of SC abnormalities and the frequency of cells with SC abnormalities. The results were compared with similar observations made on purebred animals. All the animals studied possessed 29 autosomal and one sex bivalent. The frequency of cells with abnormalities in the hybrids were 28.0% in the N-P, 29.1% in the G-S, 33.3% in the N-S and 40.0% in the G-H. The frequency of cells with abnormalities in the four hybrids was 31.5%; 57.9% of these abnormalities occurred in zygotene and 42.0% occurred in pachytene. The comparisons among the hybrids and among the hybrids and their parental breeds showed that the only significant difference was between Gyr and Gyr-Holstein-Friesian animals. Some aspects of the relationship between the frequency of cells with anomalies and the fertility of hybrids are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means (%) of bone neoformation obtained in the histomorphometric analysis were compared by Student's t-test for paired samples at 5% significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 ± 1.00% and 65.05 ± 1.23% for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. Metallic abutments can provide grayish color when in contact with thin soft tissues which may lead the implant prosthetic treatment to failure. In this context, the abutments of zirconia stand out because there is an excellent linking between esthetics and the health of peri-implant soft tissues. A consult of the published researches was made on the PubMed database from 2000 to September 2012. The including criteria were: literature reviews, clinical studies and case reports in English that focused on the response of the soft tissue in contact with zirconia implant abutments. The studies that were not in English and did not match the tackled issue were excluded. A total of 32 articles were found. According to the search strategy, just 16 articles were selected for this review. Three studies affirmed that zirconia abutments have an excellent soft tissue response; one study showed increased gingival recession with zirconia abutments and nine studies do not stand out any difference on biological behavior between titanium and zirconia abutments. Three studies affirmed that zirconia abutments provide natural gingival appearance, anatomic contour and greater esthetics. The use of zirconia abutments is recommended for anterior regions because of their greater optical properties and esthetic results and more studies should be performed and analyzed longitudinally regarding their biological response. The zirconia abutments have been established to be essential in order to achieve great esthetic results in cases of thin peri-implant soft tissues and in regions where the three-dimensional placement of implants is more superficial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Maintaining the volume of the alveolar process after extraction can be achieved by immediate implant placement and guided bone regeneration, with or without the use of biomaterials. The authors present a case report with a 10 years follow-up, rehabilitation using osseointegrated implants in the extraction area and maintenance of the volume of the alveolar process with autogenous cortical bone shavings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although there is no documented evidence that tattoo pigments can cause neurological complications, the implications of performing neuraxial anesthesia through tattooed skin are unknown. In this study, we aimed to assess whether spinal puncture performed through tattooed skin of rabbits determines changes over the spinal cord and meninges. In addition, we sought to evaluate the presence of ink fragments entrapped in spinal needles. Thirty-six young male adult rabbits, each weighing between 3400 and 3900 g and having a spine length between 38.5 and 39 cm, were divided by lot into 3 groups as follows: GI, spinal puncture through tattooed skin; GII, spinal puncture through tattooed skin and saline injection; and GIII, spinal puncture through skin free of tattoo and saline injection. After intravenous anesthesia with ketamine and xylazine, the subarachnoid space was punctured at S1-S2 under ultrasound guidance with a 22-gauge 2½ Quincke needle. Animals in GII and GIII received 5 μL/cm of spinal length (0.2 mL) of saline intrathecally. In GI, the needle tip was placed into the yellow ligament, and no solution was injected into the intrathecal space; after tattooed skin puncture, 1 mL of saline was injected through the needle over a histological slide to prepare a smear that was dyed by the Giemsa method to enable tissue identification if present. All animals remained in captivity for 21 days under medical observation and were killed by decapitation. The lumbosacral spinal cord portion was removed for histological analysis using hematoxylin-eosin stain. None of the animals had impaired motor function or decreased nociception during the period of clinical observation. None of the animals from the control group (GIII) showed signs of injuries to meninges. In GII, however, 4 animals presented with signs of meningeal injury. The main histological changes observed were focal areas of perivascular lymphoplasmacyte infiltration in the pia mater and arachnoid. There was no signal of injury in neural tissue in any animal of both groups. Tissue coring containing ink pigments was noted in all GI smears from the spinal needles used to puncture the tattooed skin. On the basis of the present results, intrathecal injection of saline through a needle inserted through tattooed skin is capable of producing histological changes over the meninges of rabbits. Ink fragments were entrapped inside the spinal needles, despite the presence of a stylet.