991 resultados para Structural engineering.


Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a modification to the ACI 318-02 equivalent frame method of analysis of reinforced concrete flat plate exterior panels. Two existing code methods were examined: ACI 318 and BS 8110. The derivation of the torsional stiffness of the edge strip as proposed by ACI 318 is examined and a more accurate estimate of this value is proposed, based on both theoretical analysis and experimental results. A series of 1/3-scale models of flat plate exterior panels have been tested. Unique experimental results were obtained by measuring strains in reinforcing bars at approximately 200 selected locations in the plate panel throughout the entire loading history. The measured strains were used to calculate curvature and, hence, bending moments; these were used along with moments in the columns to assess the accuracy of the equivalent frame methods. The proposed method leads to a more accurate prediction of the moments in the plate at the column front face, at the panel midspan, and in the edge column. Registered Subscribers: View the full article. This document is available as a free download to qualified members. An electronic (PDF) version is available for purchase and download. Click on the Order Now button to continue with the download.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The corrosion of reinforcement in bridge deck slabs has been the cause of major deterioration and high costs in repair and maintenance.This problem could be overcome by reducing the amount of reinforcement and/or altering the location.This is possible because, in addition to the strength provided by the reinforcement, bridge deck slabs have an inherent strength due to the in-plane arching forces set up as a result of restraint provided by the slab boundary conditions. This is known as arching action or Compressive Membrane Action (CMA). It has been recognised for some time that laterally restrained slabs exhibit strengths far in excess of those predicted by most design codes but the phenomenon has not been recognised by the majority of bridge design engineers. This paper presents the results of laboratory tests on fifteen reinforced concrete slab strips typical of a bridge deck slab and compares them to predicted strengths using the current codes and CMA theory. The tests showed that the strength of laterally restrained slabs is sensitive to both the degree of external lateral restraint and the concrete compressive strength.The tests particularly highlighted the benefits in strength obtained from very high strength concrete slabs. The theory extends the existing knowledge of CMA in slabs with concrete compressive strengths up to 100 N/mm[2] and promotes more economical and durable bridge deck construction by utilising the benefits of high strength concrete.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports a study carried out to develop a self-compacting fibre reinforced concrete containing a high fibre content with slurry infiltrated fibre concrete (SIFCON). The SIFCON was developed with 10% of steel fibres which are infiltrated by self-compacting cement slurry without any vibration. Traditionally, the infiltration of the slurry into the layer of fibres is carried out under intensive vibration. A two-level fractional factorial design was used to optimise the properties of cement-based slurries with four independent variables, such as dosage of silica fume, dosage of superplasticiser, sand content, and water/cement ratio (W/C). Rheometer, mini-slump test, Lombardi plate cohesion meter, J-fibre penetration test, and induced bleeding were used to assess the behaviour of fresh cement slurries. The compressive strengths at 7 and 28 days were also measured. The statistical models are valid for slurries made with W/C of 0.40 to 0.50, 50 to 100% of sand by mass of cement, 5 to 10% of silica fume by mass of cement, and SP dosage of 0.6 to 1.2% by mass of cement. This model makes it possible to evaluate the effect of individual variables on measured parameters of fresh cement slurries. The proposed models offered useful information to understand trade-offs between mix variables and compare the responses obtained from various test methods in order to optimise self-compacting SIFCON.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The deterioration of infrastructure, such as bridges, has been one of the major challenges facing both the designers and the owners of such utilities. Sustainable development and a climate of increasing commercialism has led to a requirement for more accurate means of structural analysis. Bridge assessment is one area where this is particularly relevant. It has been known for some time that bridge deck slabs have inherent enhanced strength due to the presence of arching or compressive membrane action (CMA) but only in recent years has there been some acceptance of a rational treatment of this phenomenon for design and assessment purposes. To use the benefits of arching action, this paper presents the results of tests carried out on a reinforced-concrete beam and slab bridge in Northern Ireland that incorporated novel reinforcement type and position. The research was aimed at extending previous laboratory tests on 1/3scale bridge deck edge panels. The measured crack widths and deflections have been compared with the current code requirements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We consider the problem of train planning or scheduling for large, busy, complex train stations, which are common in Europe and elsewhere, though not in North America. We develop the constraints and objectives for this problem, but these are too computationally complex to solve by standard combinatorial search or integer programming methods. Also, the problem is somewhat political in nature, that is, it does not have a clear objective function because it involves multiple train operators with conflicting interests. We therefore develop scheduling heuristics analogous to those successfully adopted by train planners using ''manual'' methods. We tested the model and algorithms by applying to a typical large station that exhibits most of the complexities found in practice. The results compare well with those found by traditional methods, and take account of cost and preference trade-offs not handled by those methods. With successive refinements, the algorithm eventually took only a few seconds to run, the time depending on the version of the algorithm and the scheduling problem. The scheduling models and algorithms developed and tested here can be used on their own, or as key components for a more general system for train scheduling for a rail line or network.Train scheduling for a busy station includes ensuring that there are no conflicts between several hundred trains per day going in and out of the station on intersecting paths from multiple in-lines and out-lines to multiple platforms, while ensuring that each train is allowed at least its minimum required headways, dwell time, turnaround time and trip time. This has to be done while minimizing (costs of) deviations from desired times, platforms or lines, allowing for conflicts due to through-platforms, dead-end platforms, multiple sub-platforms, and possible constraints due to infrastructure, safety or business policy.